• Title/Summary/Keyword: 영상평가 프로그램

Search Result 388, Processing Time 0.029 seconds

Gamma-Variate Function을 이용한 관류강조영상(Perfusion MRI) 프로그램 개발 및 평가

  • 백현만;김대원;정성택;박민석;류완석;최환준;최보영
    • Proceedings of the KSMRM Conference
    • /
    • 2002.11a
    • /
    • pp.128-128
    • /
    • 2002
  • 목적: Gamma-Variate Function을 이용하여 뇌 관류에 관련하는 새로운 재구성 영상 (CBV, CBF, MTT, TTP, BAT)을 산출할 수 있는 프로그램을 개발 및 평가 대상 및 방법: 뇌 관류와 관련한 정량적인 재구성 영상(CBV, CBF, MTT, TTP, BAT)을 얻기 위하여 Gamma-Variate Function을 이용한 Post-processing 프로그램을 개발하였다. 자기공명영상은 1.5T & 3.0T Magnum (Medinus Co., Ltd.)을 사용하였으면, 개발된 프로그램 평가를 위해 스핀에코 -EPI 펄스시퀀스(TR 2000 ms, TE 80 ms, FOV 260 mm, matrix 92$\times$128)를 사용하여 관류강조영상을 획득하였다.

  • PDF

When Evaluated Using CT Imaging Phantoms AAPM Phantom Studies on the Quantitative Analysis Method (AAPM Phantom을 이용한 CT 팬텀 영상 평가 시 정량적 분석 방법에 관한 연구)

  • Kim, Young-Su;Ye, Soo-Young;Kim, Dong-Hyun
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.8
    • /
    • pp.592-600
    • /
    • 2016
  • AAPM CT performance for special medical equipment quality control checks using a standard phantom for evaluation, using the evaluator's subjective assessment as to minimize errors due computerized assessment program to evaluate their usefulness. Phantom for evaluation AAPM CT Performance Phantom: was used, the default shooting conditions are the same as quality control checks. And, we use IMAGE J to evaluate the program. Quantitative evaluation with CT attenuation coefficient and the noise measurement, the uniformity measurement, the slice thickness measurement, contrast resolution of the measurement, a phantom image of the spatial resolution determined by the evaluation program is evaluated as self-extracting the result after processing the image, CT uniformity measurement for the evaluation that was smaller and the standard deviation of a video image processing more uniform slice thickness measurements it is difficult to evaluate due to the difference of the ratio of the measured value of the phantom image. Contrast resolution was measured cylindrical diameter 6th evaluate the shape of a circle obtained a mean value and a standard deviation of diameters, the spatial resolution of the group of source, including acceptance criteria automatically extracted result as a result of both the number of the extracted circularIt appeared. Evaluate the source image and video processing, and video to qualitative evaluation by gross were processed video image is shown excellent results. If the evaluators in order to minimize the errors of subjective judgment based on the results of the above should be done with a quantitative evaluation and qualitative evaluation utilizes a computerized assessment program is considered that further evaluation be made more efficient.

A Study on Characterize Program of Contents Editing of Motion Picture UCC (동영상 UCC 제작 콘텐츠 프로그램 특성에 관한 연구)

  • Joo, Heon-Sik
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2009.01a
    • /
    • pp.423-427
    • /
    • 2009
  • 웹 2.0시대를 맞이하여 사용자가 콘텐츠 및 동영상을 직접 만들어 참여하고 공유하는 방향으로 바뀌었고 각종 포털사이트에서도 동영상 사이트를 제공함으로써 동영상 UCC가 대중화될 수 있는 계기가 되었다. 본 논문에서는 동영상 UCC를 만들기 위해 제작, 편집, 등 프로그램 특성에 따라 효율적인 효과를 거둘 수 있을지 몇 가지 프로그램에 관해 편집 편리성, 제작 파일의 크기, 렌더링 소요 시간, 등을 사진 콘텐츠를 이용하여 비디오 전환 효과, 비디오 효과, 사운드 등을 이용하여 프로그램에 따른 장단점을 비교하였다. 프로그램 별로 실험 성능 평가 및 분석한 결과 무비메이커와 베가스 프로그램들이 비 전문가로서 전문가 못지않은 손쉽게 동영상 콘텐츠제작 및 동영상 UCC를 만들 수 있는 좋은 프로그램으로 여러 장점들을 갖고 있음을 나타내었다.

  • PDF

Phantom of the AAPM CT imaging evaluation Studies on the quantitative analysis method (CT 정도관리 영상의 정량적 분석방법에 관한 연구)

  • Kim, Young-su;Ko, Seong-Jin;Kang, Se-Sik;Ye, Soo-young
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.05a
    • /
    • pp.271-274
    • /
    • 2016
  • CT quality assurance imaging evaluation and enforcement as quantitative assessment by phantom image evaluation, assessment items include There are also contrasting the water attenuation coefficient, uniformity, noise, resolution, spatial resolution, 10mm slice thickness evaluation, contrast resolution, space for the resolution, the slice thickness evaluation, it is possible to estimate the error due to the evaluation by the subjective judgment of the tester, using a subjective error image processing program to be computed to minimize the objective evaluation. Basic recording conditions of the CT image quality control assessment is the same as special medical equipment quality control checks, the images were evaluated quantitatively using IMAGE J. For a CT attenuation coefficient, the uniformity, noise evaluation, were evaluated as CT quality control image the standard deviation of the measured value of the digital processing of image smaller and less noise uniform images than the, contrast and resolution assessment is the size of the diameter of a circle having a large the 1 inch, 0.75 inch, 0.5 inch quality if the diameter of the circle, was evaluated in the small circle in the near circle ellipse. Spatial resolution is evaluated by using a self-extracting features of an image processing program, all of the groups of members comprising the acceptance criteria to automatically extract, was evaluated to be very useful for the quantitative assessment. When CT image quality control assessment on the basis of the results such as the above, if using an image processing program to minimize the subjective judgment of the error evaluator and is determined more efficient than would be made quantitative evaluation.

  • PDF

Comparison of DICOM images and various types of images (DICOM 영상과 다양한 형식의 영상 비교)

  • Kim, Ji-yul;Ko, Seong-Jin
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.18 no.2
    • /
    • pp.76-83
    • /
    • 2017
  • In this study, the original medical image, DICOM file, was converted into TIFF, BITMAP, GIF, JPEG image file, and then the conversion loss ratio according to the image compression and conversion process was quantitatively evaluated using Origin pro and ICY image analysis program. As the evaluation method, 50% MTF, structural similarity index, MSE, RMSE, maximum signal - to - noise ratio and so on were evaluated. The TIFF image file showed the same result as DICOM image in all experimental groups, Image file format. In this study, we propose a new method for evaluating the quality of digital images by applying original evaluation program such as Origin pro or ICY medical image analysis program. Is expected to be used as research data in the field of medical image processing, and TIFF image file showing the same result as DICOM image in the basic research field using digital medical image and evaluation program that does not support DICOM file Therefore, it is believed that it will help to secure reliability in digital medical image processing research using image file.

  • PDF

Development of Image Quality Evaluation Program for Digital Diagnostic Radiography (디지털진단의료영상 화질평가 프로그램 개발)

  • Kang, Bo-Sun
    • Journal of the Korean Society of Radiology
    • /
    • v.2 no.2
    • /
    • pp.5-10
    • /
    • 2008
  • Most of the diagnostic medical radiography are rapidly replaced by digital imaging systems recently. Although with the current transition of analog to digital most of the exposure conditions and parameters are still on the basis of film-screen analog system. Moreover the evaluation of acquired digital radiographic image is not fulfilled normally because of the difficulties in handling the digital raw data. The user friendly windows program for the evaluations of digital radiographic image was developed on the MatLab platform. The program has functions for the calculation of the contrast profile, NPS(noise power spectrum), MTF(modulation transfer function), and NEQ(noise equivalent quanta).

  • PDF

Implementation of Fast Motion Estimation Program Based on Successive Elimination Algorithm (연속제거알고리즘 기반의 고속 움직임 추정 프로그램 성능평가)

  • Kim Kyung-Hyun;Sonh Seung-Il
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2006.05a
    • /
    • pp.561-564
    • /
    • 2006
  • 오늘날 컴퓨터와 데이터 통신의 급속한 발달로 인해 멀티미디어 정보통신 기술이 비약적으로 발전하고 있다. 이러한 멀티미디어 데이터 중에서 동영상은 다른 데이터 형태에 비해 정보량이 매우 방대하다. 따라서 동영상을 처리하는 시스템에서는 압축 기법이 매우 중요한 역할을 차지한다. 이에 본 논문은 연속제거 알고리즘을 기반으로 이전블록 초기 움직임 벡터 사용 및 strip단위 블록 합을 통하여 고속의 움직임 추정을 통해 영상을 복호화 하였고, 기존의 완전탐색 블록 정합방식과 영상 복원 능력 및 연산량을 비교 평가하였다. 뿐만 아니라 이후 이를 바탕으로 고속 움직임 추정 모듈을 VHDL로 구현하여 본 논문의 프로그램을 성능평가의 기준으로 이용할 것이다.

  • PDF

A Study on Respiratory-Reflected Music Play Using Skin Image (피부영상을 이용한 호흡 반영 음원 조율방법에 관한 연구)

  • KIM, Sung-Hyuck;Hong, Kwang_Seok
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2018.10a
    • /
    • pp.863-865
    • /
    • 2018
  • 본 논문에서는 피부영상을 이용한 호흡 반영 음원 조율 방법을 제안한다. 얼굴 영상으로부터 호흡 신호를 추정하기 위해 ROI(Region of Interest)를 지정하고 지정된 영역의 색상 체계를 RGB에서 YCgCo로 변환한다. 피부 관심 영역으로부터 계산된 Cg색상 데이터 평균값에 필터링을 적용하여 호흡 신호를 검출한다. 검출된 호흡 신호를 통하여 사용자의 호흡 상태를 반영한 음원 조율방법을 제안하고, 이를 구현한 응용 프로그램을 소개한다. 구현한 응용프로그램의 성능평가를 위해 피험자 15명을 대상으로 블라인드 테스트와 MOS 평가방법을 사용하였으며, 실험 결과 9명의 피실험자가 호흡을 반영한 음원과 반영하지 않은 음원에 대한 차이를 느꼈다. 또한, MOS 평가방법으로 두 음원의 선호도를 조사한 결과 총 5점 만점 중 호흡을 반영한 음원이 4점, 원음이 3.6점을 얻었으며 이를 통해 피실험자들이 호흡이 반영된 음원을 선호한다는 결과를 확인하였다.

Development of a Multi-view Image Generation Simulation Program Using Kinect (키넥트를 이용한 다시점 영상 생성 시뮬레이션 프로그램 개발)

  • Lee, Deok Jae;Kim, Minyoung;Cho, Yongjoo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2014.10a
    • /
    • pp.818-819
    • /
    • 2014
  • Recently there are many works conducted on utilizing the DIBR (Depth-Image-Based Rendering) based intermediate images for the three-dimensional displays that do not require the use of stereoscopic glasses. However the prior works have used expensive depth cameras to obtain high-resolution depth images since DIBR-based intermediate image generation method requires the accuracy for depth information. In this study, we have developed the simulation to generate multi-view intermediate images based on the depth and color images using Microsoft Kinect. This simulation aims to support the acquisition of multi-view intermediate images utilizing the low-resolution depth and color image from Kinect, and provides the integrated service for the quality evaluation of the intermediate images. This paper describes the architecture and the system implementation of this simulation program.

  • PDF

GEOMETRIC CORRECTION OF RADIOGRAPHIC IMAGES USING GENERAL PURPOSE IMAGE PROCESSING PROGRAM (일반 영상처리 프로그램을 이용한 방사선사진의 기하학적 보정에 관한 연구)

  • Cheong Ji-Seong;Kim Eun-Kyung;Lee Sang-Hoon
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.24 no.2
    • /
    • pp.371-379
    • /
    • 1994
  • 본 연구는 비규격화시켜 촬영한 두장의 방사선 사진을 일반 영상처리 프로그램으로 기하학적 보정을 하여 디지탈 공제 촬영술을 시행한 결과를 개인별로 제작된 필름유지장치를 이용하여 규격화 시켜 촬영한 두장의 방사선사진을 디지탈 공제 촬영술을 시행한 결과와 비교하여 일반 영상처리 프로그램의 임상적 유용성을 평가해보고자 시행하였다. 19명의 자원자를 대상으로 하여, 각 환자에서 4매의 하악구치부 치근단 사진을 촬영하였다. 그중 2매는 XCP 필름 유지장치만으로 평행촬영법으로 촬영하였고, 나머지 2매는 교합제에 인상재를 부가하여 개인별로 제작된 XCP필름 유지장치를 이용하여 표준화시켜 역시 평행촬영법으로 촬영하였다. 기하학적 보정은 "Adobe Photoshop"과 "NIH Image" 프로그램으로 시행하였다. 특히 "Adobe Photoshop"의 임의영상회전 기능과 "IH Image"의 공제시술시 중첩된 사진을 투명하게 보여주는 기능, 병진기능을 활용하였다. 두 사진의 유사성을 측정하기 위해 공제된 사진의 계조도의 표준편차를 구하였다. 표준화군의 평균 표준편차가 기하학적 보정군의 평균 표준편차보다 약간 낮았으나, 통계적으로 유의성이 있는 차이를 보이지는 않았다. 위의 결과로 미루어보아, 하악구치부 에서 XCP필름 유지장치로 평행촬영한 비표준화방사선사진을 "Adobe Photoshop"과 "NIH Image" 프로그램을 이용하여 기하학적 보정을 할 수 있으리라 사료된다.

  • PDF