• Title/Summary/Keyword: 영상분말

Search Result 30, Processing Time 0.027 seconds

Evaluation of Metal Composite Filaments for 3D Printing (3D 프린팅용 금속 입자 필라멘트의 물성 및 차폐 능력 평가)

  • Park, Ki-Seok;Choi, Woo-Jeon;Kim, Dong-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.5
    • /
    • pp.697-704
    • /
    • 2021
  • It is hard to get Filaments which are materials of the 3D printing Fused Deposition Modeling(FDM) method as radiation shielding in Korea. and also related research is insufficient. This study aims to provide basic data for the development of radiation shields using 3D printing by evaluating the physical properties and radiation shielding capabilities of filaments containing metal particles. after selecting five metal filaments containing metal particle reinforcement materials, the radiation shielding rate was calculated according to the Korean Industrial Standard's protective equipment test method to evaluate physical properties such as tensile strength, density, X-ray Diffraction(XRD), and weight measurement using ASTM's evaluation method. In the tensile strength evaluation, PLA + SS was the highest, ABS + W was the lowest, and ABS + W is 3.13 g/cm3 which value was the highest among the composite filaments in the density evaluation. As a result of the XRD, it may be confirmed that the XRD peak pattern of the particles on the surface of the specimen coincides with the pattern of each particle reinforcing material powder metal, and thus it was confirmed that the printed specimen contained powder metal. The shielding effect for each 3D printed composite filament was found to have a high shielding rate in proportion to the effective atomic number and density in the order of ABS + W, ABS + Bi, PLA+SS, PLA + Cu, and PLA + Al. In this study, it was confirmed that the metal particle composite filament containing metal powder as a reinforcing material has radiation shielding ability, and the possibility of using a radiation shielding filament in the future.

Developing of latent fingerprint on human skin (생체피부에서의 잠재지문 현출)

  • Lee, Hee-Il;Choi, Mi-Jung;Kim, Jai-Hoon;Park, Sung-Woo
    • Analytical Science and Technology
    • /
    • v.21 no.3
    • /
    • pp.222-228
    • /
    • 2008
  • On living skin the chances of a successfully developing latent fingerprint are very limited. This is due to the fact that continual perspiration and rapid absorption diffuse into the lipophillic layer on skin. A study was conducted to investigate effectively developing method of latent fingerprints on human skin surfaces and pig skin likely corpse's skin. We used commercial fingerprint powder, black powders, black magnetic powder, fluorescence magnetic powder, Cyanoacrylate fuming (CA) and direct lifting methods (lifting paper, glasses and photo glossy paper). Developing of fresh fingerprints on living skin was achieved with S-powderblack, CA fuming and CA fuming following S-powder, fluorescence powder. The other powder tends to overwhelm the latent print and the background. But, latent fingerprint residue was disappeared with time after deposit on a living surface. In case of pig skin likely corpse's skin, latent fingerprint detection was achieved with CA fuming following S-powder and deposited print during 6 hr at $25^{\circ}C$, 40% relative moisture yielded excellent fingerprints with clear ridge details using 1 min CA fuming. And enhancement of fingerprint detection image using forensic light source was achieved.

The Effect of Mean Brightness and Contrast of Digital Image on Detection of Watermark Noise (워터 마크 잡음 탐지에 미치는 디지털 영상의 밝기와 대비의 효과)

  • Kham Keetaek;Moon Ho-Seok;Yoo Hun-Woo;Chung Chan-Sup
    • Korean Journal of Cognitive Science
    • /
    • v.16 no.4
    • /
    • pp.305-322
    • /
    • 2005
  • Watermarking is a widely employed method tn protecting copyright of a digital image, the owner's unique image is embedded into the original image. Strengthened level of watermark insertion would help enhance its resilience in the process of extraction even from various distortions of transformation on the image size or resolution. However, its level, at the same time, should be moderated enough not to reach human visibility. Finding a balance between these two is crucial in watermarking. For the algorithm for watermarking, the predefined strength of a watermark, computed from the physical difference between the original and embedded images, is applied to all images uniformal. The mean brightness or contrast of the surrounding images, other than the absolute brightness of an object, could affect human sensitivity for object detection. In the present study, we examined whether the detectability for watermark noise might be attired by image statistics: mean brightness and contrast of the image. As the first step to examine their effect, we made rune fundamental images with varied brightness and control of the original image. For each fundamental image, detectability for watermark noise was measured. The results showed that the strength ot watermark node for detection increased as tile brightness and contrast of the fundamental image were increased. We have fitted the data to a regression line which can be used to estimate the strength of watermark of a given image with a certain brightness and contrast. Although we need to take other required factors into consideration in directly applying this formula to actual watermarking algorithm, an adaptive watermarking algorithm could be built on this formula with image statistics, such as brightness and contrast.

  • PDF

The study for the preparations and analyses of fragrance oil encapsulation using $\beta$-cyclodextrin and arabic gum ($\beta$-cyclodextrin과 arabic gum를 이용한 향료의 encapsulation제법과 분석에 관한 연구)

  • 류영상;윤영수
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.21 no.1
    • /
    • pp.84-94
    • /
    • 1995
  • Fragrance oil was encapsulated with B-Capsulation and Arabic gum for double Encapsulation to improve the demerits-cause the skin irritation, allergy and lack of odor fixative-. Powder fragrance was obtained from the paste phase using the method of spray dry. From the analyses (GC, IR, UV) and sensory teste, it was identified that frogrance was encapsulated in our reservoir.

  • PDF

Magnetic Resonance Imaging uses 3D Printed Material of Headset (Noise Reduction Effect) (자기공명영상 검사 시 3D 프린팅 재료를 이용한 헤드셋 연구 (소음저감 효과))

  • Choi, Woo Jeon;Kim, Dong Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.3
    • /
    • pp.335-341
    • /
    • 2018
  • With the improvement of medical state, patients' expectations for the most advanced medical equipment are increasing. Particularly, Magnetic Resonance Image (MRI) is used as one of the core image diagnosis methods in all clinical area. However, it has been reported that many of patients who go through the examination suffer from anxiety to the severe noise level during the examination. In this study, both the noise reduction evaluation of headsets with sound-blocking materials added to existing sound-absorbing materials and the existence of sound blocking materials as artifacts on the examination image are tested. An MRI test noise is recorded as a speaker by cross-ordination the sound material (sponge) and the sound material (acrylic plate, copper plate, and 3D copper plate) inside the headset made from 3D pring. A quantitative assessment of headsets showed that the average headset value was 81.8 dB. The average dB value of the most soundproof material combination(Copper, acrylic plate, sponge, sponge) headsets on headsets with added charactering material was measured at 70.4 dB, and MRI showed that the copper was diamagnetic substance and excluded. The second most soundproof headset(Sponge, acrylic plate, 3D copper plate, sponge) was measured at 70.6 dB and MRI showed no artifacts. The same simulation of the material printed with a 3D copper PLA containing approximately 40 % copper powder resulted in no artifacts, therefore, the material output as a 3D printing was better suited for use. For MRI related research, the mutual development of 3D printing is highly anticipated.

X-Ray Fluorescence Analysis of $Ta_2O_5, Nb_2O_5, TiO_2, SnO_2$ and $Zr_O2$ in Tin-Slags (주석-슬랙 중 $Ta_2O_5, Nb_2O_5, TiO_2, SnO_2$, 및 $ZrO_2$의 X-선 형광분석)

  • Young-Sang Kim;Chong Wook Lee
    • Journal of the Korean Chemical Society
    • /
    • v.27 no.4
    • /
    • pp.273-278
    • /
    • 1983
  • With the synthetic standards, valuable metals $(Ta_2O_5, Nb_2O_5, TiO_2, SnO_2$, and $ZrO_2$) in the tin slags have been determined by the x-ray fluorescence spectrometry. The powder sample and the standards are homogeneously mixed with anhydrous $Li_2B_4O_7$ and La_2O_3$ in weight ratio of 15 : 42 : 3 respectively. The mixed material is fused at $1,150^{\circ}C$ for 30 minutes to be changed into the glass bead. The bead is ground to (-) 325 mesh size and pelletized. The analytical results obtained in this work are consistent with the data obtained by other common methods within allowable error range. The standard deviation for $Ta_2O_5$ in PTS-H sample is 0.12 % at level of 3.40 % content.

  • PDF

Optical characteristics of $Gd_2O_3$:Eu phosphor film for x-ray imaging detector (X선 영상 검출기 적용을 위한 $Gd_2O_3$:Eu 필름의 X선 발광 특성에 관한 연구)

  • Kim, So-Yeong;Kang, Sang-Sik;Cha, Byung-Youl;Son, Dae-Woong;Kim, Jae-Hyung;Nam, Sang-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.344-344
    • /
    • 2007
  • 본 연구에서는 X선 영상 검출기로의 적용을 위하여 $Gd_2O_3$:Eu 형광체 필름을 제작하여 X선에 대한 발광 특성을 분석하였다. $Gd_2O_3$:Eu는 저온 액상법을 이용하여 분말 형태로 제조한 후 Particle-in-binder (PIB)으로 필름 형태로 제작한 후, 도핑된 Europium(Eu)의 농도와 소결 온도에 따른 X선에 대한 발광 특성을 분석하였다. Photolumimescence (PL) spectrum에서 611nm에서 가장 높은 발광 효율을 나타내었으며, 입자의 크기가 줄어듦에 따라 610nm에서 새로운 peak가 형성 되었다. 또한 Eu의 농도에 따라서 발광 강도의 차이가 관찰되었는데, 5wt%의 도핑 농도에서 가장 높은 발광 효율을 나타냈으며, 도핑 농도에 매우 의존적인 결과를 나타냈다. 소결 온도에 따른 발광 특성 분석에서, $500^{\circ}C$에서 소결하였을 때는 623nm에서 강한 peak를 나타내는 단사정계상의 발광 peak는 거의 관찰되지 않았으나 소결 온도가 $700^{\circ}C$$900^{\circ}C$에서는 peak가 확인되었다. 이를 통해 $Gd_2O_3$ 모체가 대부분 입방 대칭 구조를 가지는 $Gd_2O_3$:Eu가 합성되었음을 확인할 수 있었다. 또한 소결 온도에 따른 발광 강도를 분석한 결과 $900^{\circ}C$에서 소결하였을 때 가장 높은 발광 강도를 나타냈다. Luminescent decay time 측정 결과에서 도핑된 Eu의 농도가 커질수록 Luminescent decay time이 짧아짐을 확인할 수 있었다.

  • PDF

Fabrication and hydrogen storage property of eutectic Mg-Ni based alloy powder (공정 Mg-Ni계 합금 분말의 제조 및 수소저장 특성)

  • Hong, Seong-Hyeon;Bae, Jong-Soo;Yim, Chang-Dong;Na, Young-Sang;Song, Myoung-Youp
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.17 no.2
    • /
    • pp.174-180
    • /
    • 2006
  • The eutectic Mg-23.5%Ni alloy was casted by melting and solidification. The powders of Mg-23.5%Ni and (Mg-23.5%Ni)-10% iron oxide were prepared by mechanical grinding of casted Mg-Ni alloy and casted Mg-Ni alloy+oxide, respectively. As milling time increases, hydriding and dehydriding rates of Mg-Ni and Mg-Ni-oxide alloy powders increase. The additions of iron oxide to Mg-Ni alloy and Mg-Ni-oxide increase hydriding rates and slightly decrease dehydriding rates.

Determination of selenium in milk powder by octopole reaction cell ICP-MS (Octopole Reaction Cell이 장착된 ICP-MS에 의한 분유 중 셀레늄의 정량)

  • Cho, Sung-Eel;Kim, Mi-Ju;Kim, Yong-Ha;Min, Young-Keun;Kim, Young-Sang
    • Analytical Science and Technology
    • /
    • v.19 no.3
    • /
    • pp.203-210
    • /
    • 2006
  • The determination of trace selenium in milk powder has been studied by octopole reaction cell(ORC)-ICP-MS. The interferences by polyatomic ions and other concomitant molecular species could be removed remarkably by using $H_2$ as reaction gas in ORC. Compared to the normal mode (no cell gas), the $H_2$ cell gas mode improved the accuracy and precision. The quantitative result was average 102.7% and it was slightly higher than certified standard value of milk powder and the RSD was 7.6%.

Analysis of Photon Spectrum for the use of Added Filters using 3D Printing Materials (3D 프린팅 재료를 이용한 X-선 부가 여과 시 광자 스펙트럼에 대한 분석)

  • Cho, Yong-In;Lee, Sang-Ho
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.1
    • /
    • pp.15-23
    • /
    • 2022
  • 3D printing technology is being used in various fields such as medicine and biotechnology, and materials containing metal powder are being commercialized through recent material development. Therefore, this study intends to analyze the photon spectrum during added filtration using 3D printing material during diagnostic X-ray examination through simulation. Among the Monte Carlo techniques, MCNPX (ver. 2.5.0) was used. First, the appropriateness of the photon spectrum generated in the simulation was evaluated through SRS-78 and SpekCalc, which are X-ray spectrum generation programs in the diagnostic field. Second, photon spectrum the same thickness of Al and Cu filters were obtained for characterization of 3D printing materials containing metal powder. In addition, the total photon fluence and average energy according to changes in tube voltage were compared and analyzed. As a result, it was analyzed that PLA-Al required about 1.2 ~ 1.4 times the thickness of the existing Al filter, and PLA-Cu required about 1.4 ~ 1.7 times the thickness of the Cu filter to show the same degree of filtration. Based on this study in the future, it is judged that it can be utilized as basic data for manufacturing 3D printing additional filters in medical fields.