• Title/Summary/Keyword: 영상검출기

Search Result 846, Processing Time 0.039 seconds

Characterization of Deep Learning-Based and Hybrid Iterative Reconstruction for Image Quality Optimization at Computer Tomography Angiography (전산화단층촬영조영술에서 화질 최적화를 위한 딥러닝 기반 및 하이브리드 반복 재구성의 특성분석)

  • Pil-Hyun, Jeon;Chang-Lae, Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.1
    • /
    • pp.1-9
    • /
    • 2023
  • For optimal image quality of computer tomography angiography (CTA), different iodine concentrations and scan parameters were applied to quantitatively evaluate the image quality characteristics of filtered back projection (FBP), hybrid-iterative reconstruction (hybrid-IR), and deep learning reconstruction (DLR). A 320-row-detector CT scanner scanned a phantom with various iodine concentrations (1.2, 2.9, 4.9, 6.9, 10.4, 14.3, 18.4, and 25.9 mg/mL) located at the edge of a cylindrical water phantom with a diameter of 19 cm. Data obtained using each reconstruction technique was analyzed through noise, coefficient of variation (COV), and root mean square error (RMSE). As the iodine concentration increased, the CT number value increased, but the noise change did not show any special characteristics. COV decreased with increasing iodine concentration for FBP, adaptive iterative dose reduction (AIDR) 3D, and advanced intelligent clear-IQ engine (AiCE) at various tube voltages and tube currents. In addition, when the iodine concentration was low, there was a slight difference in COV between the reconstitution techniques, but there was little difference as the iodine concentration increased. AiCE showed the characteristic that RMSE decreased as the iodine concentration increased but rather increased after a specific concentration (4.9 mg/mL). Therefore, the user will have to consider the characteristics of scan parameters such as tube current and tube voltage as well as iodine concentration according to the reconstruction technique for optimal CTA image acquisition.

East Asia VLBI Network: Current Observation Status and Future Prospects

  • Wajima, Kiyoaki;Roh, Duk-Gyoo;Oh, Se-Jin;Jung, Taehyun;Hagiwara, Yoshiaki;Kobayashi, Hideyuki;Fujisawa, Kenta;An, Tao;Jiang, Wu;Xia, Bo;Kawaguchi, Noriyuki;Baan, Willem A.;Zhang, Ming;Hao, Longfei;Wang, Min
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.40 no.1
    • /
    • pp.75.4-76
    • /
    • 2015
  • 우리는 동아시아 각국(대한민국, 중국, 일본)의 VLBI관측망을 통합하고 구성될 동아시아 VLBI 관측망(East Asia VLBI Network; EAVN)의 초기 검증 작업을 진행하고 있다. EAVN은 2 ~ 129 GHz로 관측이 가능하는데, 주로 6.7, 8, 22, 43 GHz로의 관측을 상정하고 있다. 또한 최대 기선장은 약 5,000 km으로 공간분해능은 약 0.3 mas(43 GHz로의 관측의 경우)가 된다. 높은 공간분해능과 고감도의 특징을 활용하고 저광도 활동성은하핵이나 우리 은하의 메이저 천체 등의 연구에 대해서 위력을 나타낼 수가 있다. 우리는 EAVN 시험관측, 상관처리, 자료처리의 실행, 및 그것들을 통한 EAVN 운영의 검증을 하는 EAVN Tiger Team을 2013년에 조직하고 현재까지에 8 GHz 및 22 GHz로 8회의 VLBI 시험관측을 실행하였다. 상관처리는 주로 한국천문연구원에서 운영하고 있는 한일 공동상관기(KJJVC)와 상하이천문대의 소프트웨어 상관기(DiFX)로 실행되어 있다. 현재까지에 8 GHz 및 22 GHz 쌍방에서 프린지검출에 성공하고 있고, 올해는 영상합성을 포함한 과학적인 관측을 진행할 예정이다. 이 발표에서는 EAVN의 개요와 과학목표, 시험관측 현황과 결과, 및 앞으로의 운영 계획 등을 소개하겠다.

  • PDF

A Study on the Effect Analysis Influenced on the Advanced System of Moving Object (이동물체가 정밀 시스템에 미치는 영항분석에 관한 연구)

  • Shin, Hyeon-Jae;Kim, Soo-In;Choi, In-Ho;Shon, Young-Woo;An, Young-Hwan;Kim, Dae-Wook;Lee, Jae-Soo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.8
    • /
    • pp.87-95
    • /
    • 2007
  • In this paper, we analyzed the mr detection and the stability of the object tracking system by an adaptive stereo object hacking using region-based MAD(Mean Absolute Difference) algorithm and the modified PID(Proportional Integral Derivative)-based pan/tilt controller. That is, in the proposed system, the location coordinates of the target object in the right and left images are extracted from the sequential stereo input image by applying a region-based MAD algorithm and the configuration parameter of the stereo camera, and then these values could effectively control to pan/tilt of the stereo camera under the noisy circumstances through the modified PID controller. Accordingly, an adaptive control effect of a moving object can be analyzed through the advanced system with the proposed 3D robot vision, in which the possibility of real-time implementation of the robot vision system is also confirmed.

마이크로볼로미터 센서용 진공패키지 조립공정 특성평가

  • Park, Chang-Mo;Han, Myeong-Su;Sin, Gwang-Su;Go, Hang-Ju;Kim, Seon-Hun;Gi, Hyeon-Cheol;Kim, Hyo-Jin
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.252-252
    • /
    • 2010
  • 적외선 센서는 빛의 유무에 관계없이 주 야간 전방의 물체에서 발산하는 미약한 적외선(열선)을 감지하여 영상으로 재현하는 열상시스템은 자동차 야간 운전자 보조용 나이트 비젼, 핵심 시설의 감시 관리, 군수 등의 분야에 적용되어지고 있는 최첨단, 고부가가치를 지니고 있는 기술이다. 양자형은 센서 특성은 좋으나 냉각기(작동온도: $-196^{\circ}C$) 및 고진공 패키지인 dewar를 사용하는 반면에, 열형은 대부분 상온에서 동작되는 온도안정화를 위한 전자냉각모듈만을 구비하면 되므로 저가형으로 제작이 가능한 비냉각형 적외선 센서이다. 본 연구에서는 적외선 센서용 진공패키지 조립공정 및 패키지된 센서의 측정기술을 개발하였다. 금속 메탈패키지를 제작하였으며, 금속 진공패키지는 소자냉각용 TE Cooler와 장수명 진공유지를 위한 getter, 그리고 센서칩, 온도센서를. 장착하여 칩을 조립하였다. Cap ass'y와 base envelop의 솔더링 공정을 수행하였으며, 진공패키지의 진공유지를 위해 TMP를 이용하여 진공을 유지하고, 약 5일동안 패키지 bake-out을 수행하였다. 진공압력은 $10^{-7}\;torr$ 이하를 유지하였으며, getter를 활성화시키고, pinch-off 공정으로 조립 ass'y를 완성하였다. 진공 패키지의 기밀성은 He leak tester를 이용하여 측정하였으며, ${\sim}10^{-9}\;std.cm^3/sec$로 기밀성을 유지하였다. TE cooler를 작동한 온도안정성은 0.05 K 이하였다. 볼로미터 센서의 반응도는 $10^2\;V/W$ 이상을 나타내었으며, 탐지도는 $2{\times}10^8cm-Hz^{1/2}/W$를 나타내었다. 본 연구를 통하여 얻어진 결과는 향후 2차원 열영상용 어레이 검출기 및 웨이퍼수준의 패키징 공정에 유용하게 응용될 것으로 판단된다.

  • PDF

Acoustic Signal-Based Tunnel Incident Detection System (음향신호 기반 터널 돌발상황 검지시스템)

  • Jang, Jinhwan
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.18 no.5
    • /
    • pp.112-125
    • /
    • 2019
  • An acoustic signal-based, tunnel-incident detection system was developed and evaluated. The system was comprised of three components: algorithm, acoustic signal collector, and server system. The algorithm, which was based on nonnegative tensor factorization and a hidden Markov model, processes the acoustic signals to attenuate noise and detect incident-related signals. The acoustic signal collector gathers the tunnel sounds, digitalizes them, and transmits the digitalized acoustic signals to the center server. The server system issues an alert once the algorithm identifies an incident. The performance of the system was evaluated thoroughly in two steps: first, in a controlled tunnel environment using the recorded incident sounds, and second, in an uncontrolled tunnel environment using real-world incident sounds. As a result, the detection rates ranged from 80 to 95% at distances from 50 to 10 m in the controlled environment, and 94 % in the uncontrolled environment. The superiority of the developed system to the existing video image and loop detector-based systems lies in its instantaneous detection capability with less than 2 s.

Color Change Information Collection Using Python in The Event of Color Temperature Change (색온도 변화 시 파이썬을 이용한 색상 변화 정보의 수집)

  • Jeon, Byungil;Kim, Semin;Lee, Gyujeong;Lee, Jeongwon;Lee, Choong Ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2019.05a
    • /
    • pp.618-620
    • /
    • 2019
  • Smart Farm, which combines agriculture and ICT convergence technology, is at a lower stage than other industries in Korea, but it is also one of the most active research and development fields. Smart Farm aims to improve the efficiency of each step by collecting, processing and analyzing various information of agriculture sector through convergence between agriculture and ICT technology. In this study, we studied the image processing method that can distinguish strawberry which can be harvested at harvest time by color for smart farm composition of strawberry which is a horticultural crop. Strawberry harvesting requires a lot of labor in the process of growing strawberries. In this study, we aim to collect information necessary for labor saving in strawberry harvester. As a precedent study, we plan to implement a form in which the color temperature changes according to the light direction and brightness value through OpenCV color detection using Python. In the future, it is planned to study strawberry color value suitable for harvest by applying compensation value to color temperature change.

  • PDF

Development of a Small Gamma Camera Using NaI(T1)-Position Sensitive Photomultiplier Tube for Breast Imaging (NaI (T1) 섬광결정과 위치민감형 광전자증배관을 이용한 유방암 진단용 소형 감마카메라 개발)

  • Kim, Jong-Ho;Choi, Yong;Kwon, Hong-Seong;Kim, Hee-Joung;Kim, Sang-Eun;Choe, Yearn-Seong;Lee, Kyung-Han;Kim, Moon-Hae;Joo, Koan-Sik;Kim, Byuug-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.4
    • /
    • pp.365-373
    • /
    • 1998
  • Purpose: The conventional gamma camera is not ideal for scintimammography because of its large detector size (${\sim}500mm$ in width) causing high cost and low image quality. We are developing a small gamma camera dedicated for breast imaging. Materials and Methods: The small gamma camera system consists of a NaI (T1) crystal ($60 mm{\times}60 mm{\times}6 mm$) coupled with a Hamamatsu R3941 Position Sensitive Photomultiplier Tube (PSPMT), a resister chain circuit, preamplifiers, nuclear instrument modules, an analog to digital converter and a personal computer for control and display. The PSPMT was read out using a standard resistive charge division which multiplexes the 34 cross wire anode channels into 4 signals ($X^+,\;X^-,\;Y^+,\;Y^-$). Those signals were individually amplified by four preamplifiers and then, shaped and amplified by amplifiers. The signals were discriminated ana digitized via triggering signal and used to localize the position of an event by applying the Anger logic. Results: The intrinsic sensitivity of the system was approximately 8,000 counts/sec/${\mu}Ci$. High quality flood and hole mask images were obtained. Breast phantom containing $2{\sim}7 mm$ diameter spheres was successfully imaged with a parallel hole collimator The image displayed accurate size and activity distribution over the imaging field of view Conclusion: We have succesfully developed a small gamma camera using NaI(T1)-PSPMT and nuclear Instrument modules. The small gamma camera developed in this study might improve the diagnostic accuracy of scintimammography by optimally imaging the breast.

  • PDF

Assembly and Testing of a Visible and Near-infrared Spectrometer with a Shack-Hartmann Wavefront Sensor (샤크-하트만 센서를 이용한 가시광 및 근적외선 분광기 조립 및 평가)

  • Hwang, Sung Lyoung;Lee, Jun Ho;Jeong, Do Hwan;Hong, Jin Suk;Kim, Young Soo;Kim, Yeon Soo;Kim, Hyun Sook
    • Korean Journal of Optics and Photonics
    • /
    • v.28 no.3
    • /
    • pp.108-115
    • /
    • 2017
  • We report the assembly procedure and performance evaluation of a visible and near-infrared spectrometer in the wavelength region of 400-900 nm, which is later to be combined with fore-optics (a telescope) to form a f/2.5 imaging spectrometer with a field of view of ${\pm}7.68^{\circ}$. The detector at the final image plane is a $640{\times}480$ charge-coupled device with a $24{\mu}m$ pixel size. The spectrometer is in an Offner relay configuration consisting of two concentric, spherical mirrors, the secondary of which is replaced by a convex grating mirror. A double-pass test method with an interferometer is often applied in the assembly process of precision optics, but was excluded from our study due to a large residual wavefront error (WFE) in optical design of 210 nm ($0.35{\lambda}$ at 600 nm) root-mean-square (RMS). This results in a single-path test method with a Shack-Hartmann sensor. The final assembly was tested to have a RMS WFE increase of less than 90 nm over the entire field of view, a keystone of 0.08 pixels, a smile of 1.13 pixels and a spectral resolution of 4.32 nm. During the procedure, we confirmed the validity of using a Shack-Hartmann wavefront sensor to monitor alignment in the assembly of an Offner-like spectrometer.

A Study of Quality Control of Nuclear Medicine Counting System and Gamma Camera (핵의학 계측기기 및 감마카메라의 정도관리 연구)

  • 손혜경;김희중;정해조;정하규;이종두;유형식
    • Progress in Medical Physics
    • /
    • v.12 no.2
    • /
    • pp.103-112
    • /
    • 2001
  • Purpose: The purpose of this study was to investigate the current status of performing nuclear medicine quality control in korea and to test selected protocols of quality control of nuclear medicine counting system and gamma camera. Materials and Methods: Fifty three hospitals were included to investigate the current status of nuclear medicine quality control in korea. The precision of dose calibrator and thyroid uptake system was measured with Tc-99m 35.52 MBq for 2 minuets and Tc-99m 5.14 MBq for 10 sec every one minute, respectively. The sensitivity of CeraSPECT$^{TM}$ with low energy high resolution parallel hole collimator was measured using two cylindrical phantoms with 15 cm in diameter and 12 cm and 30 cm in heights containing Tc-99m. The correction factor for sensitivity of CeraSPECT$^{TM}$ was calculated using phantom data. The system planar sensitivity, uniformity, count rate and spatial resolution were measured for Varicam gamma camera with low energy high resolution parallel hole collimator using 140 keV centered 20% energy window, 256$\times$256 or 512$\times$512 matrix sizes. Results: The quality control of dose calibrator and well counter were showed poor performance status. On the other hand, The quality control of gamma camera and other systems were showed relatively good performance status. The results of precision of dose calibrator and thyroid uptake system was $\pm$1.4%(<$\pm$5%) and chi^2=29.7(>16.92), respectively. It showed that the sensitivity of CeraSPECT$^{TM}$ was higher in center slices compared with the edge slices. After correction of nonuniform sensitivities for patient data, it showed better results compare with prior to correction. System planar sensitivity of Varicam gamma camera was 4.39 CPM/MBq. The observed count rate at 20% loss was 102,407 counts/sec (head 1), 113,427 counts/sec (head 2), when input count rate was 81,926 counts/sec (head 1), 90,741 counts/sec (head 2). The spatial resolution without scatter medium were 8.16 mm of FWHM and 14.85 mm of FWTM. The spatial resolution with scatter medium were 8.87 mm of FWHM and 18.87 mm of FWTM. Conclusion: It is necessary to understand the importance of quality control and to perform quality control of nuclear medicine devices.vices.

  • PDF

The Solution to the Limitation of the Conventional Digital X-ray System and Its Feasibility Test (디지털 X선 촬영장치의 한계 검사 개선 및 유용성 평가)

  • Gil, Jong-Won;Park, Jeong-Ho;Bae, Seok-Hwan;Hwang, Hye-Jeong;Kim, Yong-Gwon
    • Journal of Digital Convergence
    • /
    • v.12 no.12
    • /
    • pp.371-379
    • /
    • 2014
  • In this study, we conducted a survey on the limited examinations of the DR system to the 30 radiologic technologists engaging in the clinical sites and university hospitals in Daejeon metropolitan city from Oct. 15, 2012 to Nov. 15, 2012. Based on the survey results, we propose the conceptual design of a supplementary table for the conventional DR system to extend the examination capability and overcome the limitation of DR system. And, we evaluated the convenience and usefulness of the proposed table by applying it to five subjects. Ten experts were involved to evaluate the clinical usefulness of the obtained images. In this study, the experimental results show the feasibility to overcome the limited examination of the conventional DR system, and the proposed supplementary table may be beneficial to patients and hospitals.