• Title/Summary/Keyword: 염제거

Search Result 798, Processing Time 0.032 seconds

Phosphate removal efficiency and the removal rate constant by particle sizes of converter slag and conditions of the wastewater (전로슬래그의 입도 크기 및 폐수의 조건 변화에 따른 인산염 제거효율과 제거 속도상수에 관한 연구)

  • Lee, Sang Ho;Hwang, Jeong Jae
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.6
    • /
    • pp.841-849
    • /
    • 2012
  • The effluent quality of phosphorus is strengthened by the national standard to conserve water resources to lessen the eutrophication threat. The soluble phosphate in the wastewater effluent can be removed using the converter slag as solid waste produced through the steel making process. The experiments for removal efficiencies and removal constants were performed for this research with the artificial wastewater following several different conditions, particle size, phosphate concentration and initial pH. The correlation coefficients of Freundlich adsorption isothem were 0.9505 for $PS_A$, 0.9183 for $PS_B$, respectively. The removal efficiency was 87-94 % for $PS_A$ and 90-96 % for $PS_B$ respectively. The pH of the wastewater was elevated to pH 11.8 for the initial pH 8.5, phosphate removal efficiency was the highest as 84 % ~ 98 %. In case of 10 mg/L of the intial phosphate, the removal efficiency was 96 ~ 98 %. The more initial pH increases, the higher the reaction rate constant is.

Efficiency Estimation for Desalination System of Seawater Using Reverse Osmosis Membrane (역삼투압막 해수담수화 장치의 미네럴 분리 성능평가)

  • Moon, Deok-Soo;Jung, Dong-Ho;Kim, Hyeon-Ju;Shin, Phil-Kwon
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.8 no.2
    • /
    • pp.60-66
    • /
    • 2005
  • When external pressure higher than osmosis pressure is reversely derived into solution, its solvent is moved into the solution having lower concentration, which is called 'reverse osmosis'. We investigated the desalination application of deep ocean water using reverse osmosis pressure of $40-70\;kgf/cm^2$ We observed how to operational factor j like flow rate, water temperature and pressure have effect on efficiency of reverse osmosis membrane and salts rejection. Fluxes of reverse osmosis membrane are directly proportional to water temperature and pressure. However, salts rejection rates are positively correlated with pressure and inversely proportional to water temperature. Separation efficiencies of osmosis membrane for major elements such as $Mg^{2+},\;Ca^{+2},\;Na^+\;and\;K^+$ are as follows in a strong electrolysis solution like seawater; $Ca^{2+},\;Mg^{2+}>K^+>Na^+$. Rejection rates of $Mg^{2+}\;and\;Ca^{2+}$ that have high electric charges are over 99% and show positively correlation with water temperature. Rejection rates of $Na^+$ having low electric charge is observed to be 98%-99%, which rates is much lower than those of $2^+$ charged ions like $Ca^{2+}\;and\;Mg^{2+}$. Ion rejection rates of boron, B, are much low because boron is present il free state or gas phase in seawater. Boron concentration in desalination water is over criteria of Korean drinking water, 0.3 mg/L. However, we could satisfied with the criteria of drinking water under the operation condition like temperature $5^{\circ}C$ and pressure $70kgf/cm^2$, using the relationship that rejection rates of boron is proportional to pressure and is inversely proportional to water temperature

  • PDF

Effect of Sulfate and Heavy Metals on Methanogenic Activation of in the Anaerobic Digestion of Tannery Wastes (피혁폐수의 혐기성 소화시 황산염과 중금속이 메탄균 활성에 미치는 영향)

  • Shin, Hang Sik;Oh, Sae Eun
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.4 no.1
    • /
    • pp.13-21
    • /
    • 1996
  • For treating tannery wastewater containing high sulfate and heavy metals, test was performed to assess their performance, competition between SRB (sulfate reducing bacteria) and MPB (methane producing bacteria), and the activity of MPB according to change of chromium concentrations. COD removal efficiency was above 70% at VLR (volumetric loading rate) of 2.0 gCOD/I.day and HRT (hydraulic retention time) of 18hrs at $35^{\circ}C$. In the competition between SRB and MPB, about 15% of the removed COD was utilized by SRB in the begining, but it became 43% at the end. It indicated that MPB was strongly suppressed by the occurrence of significant sulfate reduction since a large electron flow was uptaken by SRB. For the entire experiment, removal efficiencies of chromium concentration were more than 90%. Despite high removal efficiencies of chromium concentration, performance of reactor did not change significantly during the experimental periods. Expecially, chromium (III) is tannery wastewater is less toxic than chromium (VI).

  • PDF

Endocarditis with Intracardiac Migration of Transvenous Permanent Pacing Lead - 1 Case Report - (영구 경정맥 심박조율도관의 심장내 이동과 동반된 심내막염 - 1례 보고 -)

  • Ku, Gwan-Woo;Kang, Shin-Kwang;Won, Tae-Hee;Kim, Si-Wook;Yu, Jae-Hyun;Na, Myung-Hoon;Lim, Seung-Pyung;Lee, Young
    • Journal of Chest Surgery
    • /
    • v.35 no.11
    • /
    • pp.831-834
    • /
    • 2002
  • When any part of the pacemaker system is infected, all pacemaker hardware should be removed, because reinfection rates of 51% to 77% have been noted in patients whose infected pacemaker system has been only partially explanted. The removal of infected leads during cardiopulmonary bypass prevents mechanical injury as well as the spread of infection and vegetation. We report one case of endocarditis by staphylococcus aureus with infected transvenous pacing lead which was migrated into the heart from the left subclavian vein. We removed the migrated pacing lead and vegetation under cardiopulmonary bypass.

Biological Perchlorate Reduction in Municipal Sewage (도시하수에서 생물학적 퍼클로레이트의 환원)

  • Choi, Hyeoksun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.9
    • /
    • pp.675-680
    • /
    • 2013
  • This research was done to evaluate the potential for destruction of perchlorate in municipal sewage. Laboratory experiments were conducted in flasks containing 3 liters of raw sewage. Sewage was mixed with defined amount of perchlorate and various additives. Perchlorate reduction in sewage did occur, but was quite variable, ranging from 0 to 72% over 72 hour. Addition of even a small amount of perchlorate acclimated biomass (167 mg/L SS) significantly reduced the lag and resulted in complete perchlorate removal. Perchlorate reduction in sewage-brine mixtures was inhibited when the dissolved oxygen level was greater than 2 mg/L, and when the mixture salinity was relatively high (conductivity = 14 mS with equivalent TDS = 8 g/L). When nitrate ($NO_3{^-}$) was present with perchlorate in the laboratory flask tests of sewage-brine mixtures, nitrate reduction proceeded first. A significant amount of nitrite ($NO_2{^-}$) accumulated in the sewage-brine mixtures, accounting for about 66% of initial nitrate nitrogen ($NO_3$-N).

Phosphate Concentration Dependent Degradation of Biofilm in S. aureus Triggered by Physical Properties (인산염 농도에 따른 물성 변화로 발생하는 황색포도상구균 바이오필름 제거 현상)

  • Song, Sang-Hun;Hwang, Byung Woo;Son, Seong Kil;Kang, Nae-Gyu
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.47 no.4
    • /
    • pp.361-368
    • /
    • 2021
  • The objective of this study was to establish technology for removing bacteria with human- and eco-friendly material. Staphylococcus aureus as an important component for balanced equilibrium among microbiomes, was cultured under various concentrations of phosphate. Experimental observation relating to physical properties was performed in an addition of phosphate buffer. Statistically minimum value of size and hardness using atomic force microscope was observed on the matured biofilm at 5 mM concentration of phosphate. As a result of absorbance for the biofilm tagged with dye, concentration of biofilm was reduced with phophate, too. To identify whether this reduction by phosphate at the 5 mM is caused by counter ion or not, sodium chloride was treated to the biofilm under the same condition. To elucidate components of the biofilm counting analysis of the biofilm using time-of-flight secondary ion mass spectrometry was employed. The secondary ions from the biofilm revealed that alteration of physical properties is consistent to the change of extracellular polymeric substrate (EPS) for the biofilm. Viscoelastic characterization of the biofilm using a controlled shear stress rheometer, where internal change of physical properties could be detected, exhibited a static viscosity and a reduction of elastic modulus at the 5 mM concentration of phosphate. Accordingly, bacteria at the 5 mM concentration of phosphate are attributed to removing the EPS through a reduction of elastic modulus for bacteria. We suggest that the reduction of concentration of biofilm induces dispersion which assists to easily spread its dormitory. In conclusion, it is elucidated that an addition of phosphate causes removal of EPS, and that causes a function of antibiotic.