• Title/Summary/Keyword: 염제거

Search Result 800, Processing Time 0.023 seconds

Eosinophilic Polypoid Cystitis in a Cocker Spaniel Dog (코커스파니엘종 개에서 발생한 호산구성 폴립성 방광염)

  • Yoon, Won-Kyoung;Hyun, Chang-Baig
    • Journal of Veterinary Clinics
    • /
    • v.29 no.3
    • /
    • pp.247-249
    • /
    • 2012
  • An 8-year-old castrated male Cocker Spaniel (weighing 12.0 kg) was referred to the Kangwon National University Veterinary Teaching Hospital, with primary complaints of persistent hematuria. Diagnostic studies revealed neutrophilia, hematuria, proteinuria, abnormal irregular shaped hyperechoic lesion in urinary bladder. The lesion was demarcated from the intact region of bladder and consisted of eosinophils, macrophages, lymphocyte and fibrocytes. Based on the histopathological exam, the case was diagnosed as eosinophilic polypoid cystitis and treated by surgical removal and short-term medical therapy (meloxicam and amitriptyline). The therapy was successful and recurrence has not been occurred.

Left Ventricular Pseudoaneurysm after Surgery for Infective Endocarditis with Annular Abscess - A case report - (판막륜 농양을 동반한 감염성 심내막염 수술 후 발생한 좌심실 가성류 - 치험 1예 -)

  • 황호영;김기봉
    • Journal of Chest Surgery
    • /
    • v.36 no.4
    • /
    • pp.273-276
    • /
    • 2003
  • We report a surgical case of 39-year-old male with a pseudoaneurysm of the left ventricle. Four years ago, the patient underwent aortic and mitral valve replacements with mechanical valves and abscess removal for infective endocarditis with annular abscess. Recent echocardiography demonstrated a communication between left ventricle and abscess pocket, and the size of pocket increased further at the follow-up echocardiography. The patient underwent patch closure of the defect between left ventricle and pseudoaneurysm located at the aortomitral fibrous continuity, under the cardiopulmonary bypass and cardioplegia. The postoperative course was uneventful and the patient was discharged on the 9th postoperative day.

A study on Improvement of Groupwise IC using the power based sorting method (그룹형 간섭제거기의 정렬기법 개선을 통한 성능 향상에 관한 연구)

  • 박재원;염순진;박용완
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.27 no.7B
    • /
    • pp.686-694
    • /
    • 2002
  • In this paper, we introduce an improved sorting method of the IGIC(Improved initial stage Grouping Interference Canceller) system for advanced BER(Bit Error Rate) performance in DS-CDMA. Among non liner Interference Cancellers, the PIC(Parallel IC) with advanced initial stage by sorting method has the name of the IGIC(Improved initial stage Grouping Interference Canceller) system. In this system, All group are shared with the same number of users. But, if each group are divided the same users, so that difference of the signals strength appeared greatly in the same group. Up to this time, the weak signals have more effect of the MAI (Multiple Access Interference) from the strong signals in the same group. The proposed IC (Interference Canceller) to solve those problems has a better performance by using improved sorting method from IGIC system. A new sorting method is the technique that the strength of signals would be liked in the same group. So, the MAI is reduced as difference of signal strength minimize. Analysis of performance assayed to make comparison with other non liner interference canceller when power controlled and not one.

Analysis on Characteristics of Acidic Air Pollutants and PM-2.5 during a Winter Season in Ulsan using an Annular Denuder System (Annular Denuder System을 이용한 울산지역에서의 겨울동안의 산성오염물질 및 PM-2.5 농도 특성분석)

  • 이병규;전나영
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2003.05b
    • /
    • pp.273-274
    • /
    • 2003
  • 산업의 발전과 인구의 과밀, 자동차의 증가는 오염물질의 배출을 크게 증가시켰지만, 최근 관련 규제의 강화로 각 도시의 대기질은 많이 개선되어 왔다. 그러나 중국으로부터 유입되고 있는 많은 대기오염물도 국내 산성비의 8∼42% 정도나 영향을 미친다고 하며, 국내 산업체에서 배출되는 오염물질의 양도도 같은 규모의 여전히 선진국에 높아서 환경 기준치를 넘는 경우도 자주 나타내고 있다. 질산염, 황산염 등의 산성오염물질은 대기중에 에어로졸과 산성가스 형태로 존재하고 있다. 이러한 산성물질들은 건성강하라는 형태로 지표면에 자연 침강되거나, 눈이나 비 또는 안개와 같은 습성강하 형태로 지표면으로 침적되어 대기중에서 제거되기도 한다. (중략)

  • PDF

Phosphate Removal from Wastewater by Surface-Modified Pinus rigida Powder (표면개질된 Pinus rigida 분말에 의한 하수의 인산염 제거)

  • Jeong, Myoung-Sun;Kim, Yeong-Kwan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.2
    • /
    • pp.241-248
    • /
    • 2011
  • This research was performed to evaluate the efficacy of phosphate removal from wastewater by surface-modified wood powder and to clarify the removal mechanisms. In this work, Pinus rigida which is abundant in Korea and has little economic value was used in preparation of the wood powder as a sorbent material. The experiments were carried out in 2 phases, isothermal adsorption test and column test. The results of adsorption test fitted well both the Langmuir and Freundlich isothermal equations. Adsorption capacity was highest with the bark powder followed by the mixed powder(50% bark powder and 50% woody powder) and woody powder. Phosphate removal efficiency was as high as 98% at initial phosphate concentration of 50mg/L. Specific surface area of the powder increased following the experiment and phosphate removal was speculated to occur through adsorption mechanism. Energy dispersive X-ray analysis(EDXA) revealed that the phosphate adsorbed onto the surface of the powder was in the form of strengite($FePO_{4}$).

Solvent Effect in Nucleophilic Reactions of Substituted Benzoyl Chlorides with p-Nitroaniline (치환염 벤조일과 파라니트로아닐린과의 친핵반응에 미치는 용매효과에 관한 연구)

  • Kim, Wang Gi
    • Journal of the Korean Chemical Society
    • /
    • v.18 no.4
    • /
    • pp.251-258
    • /
    • 1974
  • The rate constants for the nucleophilic substitution reactions of substituted benzoyl chlorides with p-nitroaniline in such solvents as acetone, acetonitrile, methanol, ethanol, etc. were conductometrically determined, and the activation thermodynamic parameters were also evaluated. In result, the reaction rates were faster in protic solvents than in aprotic solvent; in the solvents of similar property, the reaction rate in the solvent of the large dielectric constant was faster than that in the solvent of the small dielectric constant. Hammett plots in individual solvents showed the straight lines with positive slope; and we concluded that the reaction occurred via the addition-elimination mechanism.

  • PDF

The first human case of Clinostomum complanatum (Trematoda: Clinostomidae) infection in Korea (새인두흡충(Clinostomum complanatum)에 의한 인두염 제1례)

  • 정동일;문주환
    • Parasites, Hosts and Diseases
    • /
    • v.33 no.3
    • /
    • pp.219-224
    • /
    • 1995
  • The authors present the first human case of Clinostomum pharyngitis in Taegu, Korea. The patient was a 56-year old male who visited an otolarlngology clinic due to foreign body sensation and pain of the pharyngeal region for 3-4 days. He used to eat raw fresh-water fish. Otolaryngological examinations revealed a living worm adhered to the right posterior pharyngeal wall. The worm removed was identified as C. complonotum after morphological observations. It is likely that more attention should be paid to eating raw fresh-water fish in Korea siC regards to Clinostomunl pharyngitis.

  • PDF

The Study on the Odor Removal of Digested sludge using BIO-CLOD (BIO-CLOD를 이용한 소화슬러지의 악취저감에 대한 연구)

  • Sung, Il-Wha
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.12
    • /
    • pp.8665-8672
    • /
    • 2015
  • In this study, to investigate the feasibility of malodorous substance and organic matter removal by digest sludge in sewage treatment plants, ammonia, methyl mercaptan(MMC), and hydrogen sulfide($H_2S$) in a reactor submerged with BIO-CLOD(BIO-CLOD) and a reactor not submerged with BIO-CLOD(Non BIO-CLOD) were measured at 24 hours, 48 hours, and 72 hours after the submergence of BIO-CLOD. Whereas the reactor in which BIO-CLOD was submerged showed an ammonia removal rate of 48% and high $H_2S$ and MMC removal rates exceeding 98% in 24 hours, the reactor in which BIO-CLOD was not submerged showed an ammonia removal rate of 45%, an $H_2S$ removal rate of 71%, and an MMC removal rate of 84% in 24 hours indicating the possibility of removal of malodor using BIO-CLOD. A nitrification was shown in which ammonia concentrations decreased over time while nitrate nitrogen concentrations increased and sulfur based malodor components were oxidation decomposed indicating that BIO-CLOD had effects to increase sulfate concentrations in the solution and that sulfate concentration increases and atmospheric $H_2S$ removal rates were correlated with each other. With regard to decreases in organic matter in reactor effluents, BIO-CLOD did not affect in a short period of time and when reactors were operated with HRT 12 hours and HRT 24 hours, HRT 12 hours was considered desirable in terms of economy.

A Study on the Removal of Dissolved Matter in Groundwater and Characteristics of Fouling using NF and RO (NF와 RO를 이용한 지하수중 용존성 물질의 제거와 막 오염의 특성에 관한 연구)

  • Gwon, Eun-Mi;Yu, Myong-Jin
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.12
    • /
    • pp.2205-2213
    • /
    • 2000
  • To investigate removal efficiency of dissolved matter by NF and RO, a pilot plant was operated for six months using groundwater treated by UF membrane. After the pilot plant operation, we performed autopsy test to identify characteristics of foulant attached on the membrane surface applying the used NF and RO in the pilot plant test. In autopsy test, we measured permeate flux and recovery rate of flux by chemical cleaning in each membrane. We also analyzed chemical cleaning disposal to examine component of foulant. Permeate flux of NF and RO1 showed rapid decline after 100 days of operation. Especially, reduction of specific flux in RO1 was more serious than in NF. Specific flux of RO2 with a low recovery rate resulted in gradual flux decline. Removal efficiencies of dissolved inorganic matters as a conductivity were 76.3%, 88.2% and 95.3% respectively for NF, RO1 and RO2, and RO2 presented the highest removal efficiency. And those of dissolved organic matters as TOC were about 80% for both NF and RO. The specific flux of membranes declined gradually from the feed water inlet to outlet of the membrane module and it showed that membrane fouling increased along the feed flow direction. Namely, concentration of pollutants became higher and volume of feed water was less as the feed flow approached to the outlet. It seemed that major foul ants were Ca consolidated into inorganic material and Si consolidated into organic material on the membrane surface. Fe was a great contribution to irreversible fouling. The SEM results indicated that the organic matter was attached to the first layer, closer to the membrane, and then inorganic matter with tetragonal shape layered over them. We could not observe biofouling because microorganism, which was cause of biofouling, was almost pretreated in UF membrane.

  • PDF

Evaluation of Cu Removal from Mine Water in Passive Treatment Methods : Field Pilot Experiments (자연정화 기반의 현장 파일럿 실험을 통한 광산배수 구리 정화효율 평가)

  • Oh, Youn Soo;Park, Hyun Sung;Kim, Dong Kwan;Lee, Jin Soo;Ji, Won Hyun
    • Economic and Environmental Geology
    • /
    • v.53 no.3
    • /
    • pp.235-244
    • /
    • 2020
  • Copper (Cu), one of the main contaminants in the mine drainage from the closed mine area, needs to be removed before exposed to environment because of its toxicity even in the low concentration. In this study, passive treatment based field pilot experiments using limestone and compost media were conducted during 9 months for enhancing Cu removal efficiency of the mine water treatment facility of S mine located in Goseong, Gyeongsangnam-do in South Korea. The pH increase and Cu removal efficiency showed high value at Successive Alkalinity Producing System ( SAPS) > Reducing and Alkalinity Producing System (RAPS) > limestone reactor in a sequence. The compost media using in SAPS and RAPS contributed to raise pH by organic material decomposition with generating alkalinity, thus, Cu removal efficiency increased. Also, experimental results showed that Cu removal efficiency was proportional to pH increase, meaning that pH increase is the main mechanism for Cu removal. Moreover, Sulfate Reduction Bacteria (SRB) was identified to be most activated in SAPS. It is inferred that the sulfate reduction reaction also contributed to Cu removal. This study has the site significance in that the experiments were conducted at the place where the mine water generates. In the future, the results will be useful to select the more effective reactive media used in the treatment facility, which is most appropriate to remediate mine water from the S mine.