• Title/Summary/Keyword: 염소처리

Search Result 448, Processing Time 0.028 seconds

Interaction of Fibroblast Cells onto Chloric Acid-treated Poly($\alpha$-hydroxy acid) Polymer Surfaces (염소산 처리된 Poly($\alpha$-hydroxy acid)계 고분자 표면과 섬유아세포의 상호작용)

  • 이상진;강길선;이진호;이영무;이해방
    • Polymer(Korea)
    • /
    • v.24 no.6
    • /
    • pp.877-885
    • /
    • 2000
  • PLA, PGA and PLGA films were treated with chloric acid mixture solution [70% perchloric acid (HClO$_4$)/potassium chlorate (KClO$_3$) aq. saturated solution, 3 : 2] to increase surface wettability and thus cell compatibility. The surface-treated PLA, PGA, and PLGA films were characterized by the measurement of water contact angle, electron spectroscopy for chemical analysis, and scanning electron microscopy. Surface wettability of chloric acid-treated PLA, PGA, and PLGA film surfaces was gradually increased with increase of treatment time. Unlike EtOH pre-treatment, chloric acid-treated polymer films maintain hydrophilic surface after drying. In cell adhesion test, fibroblasts were cultured on the chloric acid-treated film surfaces for 1 and 2 days. As the surface wettability increased, the cell adhesion on the surface were increased. In conclusion, this study demonstrated that the surface wettability of polymer plays an important role for cell adhesion and proliferation behavior.

  • PDF

Removal of Algogenic Organic Matter in Drinking Water Treatment Process (정수처리공정에서 조류유래 유기물질의 제거)

  • Park, Se-Jin;Cha, Il-Kwon;Yoon, Tai-Il
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.4
    • /
    • pp.377-384
    • /
    • 2005
  • Algae causes not only the eutrophication of lake, but also the deterioration of drinking water process. Especially, algogenic organic matters(AOM) are assumed as disinfection by-products(DBPs) precursors like humic and fulvic acids. In this study, it was investigated the characteristics changes of algogenic organic matter(AOM) by prechlorination and coagulation treatment. Evaluation of enhanced coagulation and applicability of UV oxidation process were also evaluated as the drinking water treatment system for the eutrophicated water source. prechlorination was effective process for algae removal but caused releasing of dissolved organic matter(DOC) into water due to the destruction of algae's cell. In coagulation treatment with Fe(III) coagulant, reaction pH is an important factor for the removal of AOM and triholomathanes(THMs). At pH 5, removal efficiency of DOC and THMs were dramatically improved by 50% and 28%, respectively, in comparison with the conventional coagulation treatment at about pH 7. Photo-Fenton($UV/H_2O_2/Fe^{3+}$) process among the UV oxidations is the most effective system to remove AOM, but its removal efficiency was lower than that of enhanced coagulation treatment at pH 5.

Effects of Chlorine Water and Plasma Gas Treatments on the Quality and Microbial Control of Latuca indica L. Baby Leaf Vegetable during MA Storage (염소수와 플라즈마 가스 처리가 왕고들빼기 어린잎채소의 MA저장 중 품질과 미생물 제어에 미치는 영향)

  • Kim, Ju Young;Han, Su Jeong;Whang, Lixia;Lee, Joo Hwan;Choi, In-Lee;Kang, Ho-Min
    • Journal of Bio-Environment Control
    • /
    • v.28 no.3
    • /
    • pp.197-203
    • /
    • 2019
  • This study was carried out to investigate the effect of chlorine water and plasma gas treatment on the quality and microbial control of Latuca indica L. baby Leaf during storage. Latuca indica L. baby leaves were harvested from a plant height of 10cm. They were sterilized with $100{\mu}L{\cdot}L^{-1}$ chlorine water and plasma-gas (1, 3, and 6hours), and packaged with $1,300cc{\cdot}m^{-2}{\cdot}day^{-1}{\cdot}atm^{-1}$ films and then stored at $8{\pm}1^{\circ}C$ and RH $85{\pm}5%$ for 25days. During storage, the fresh weight loss of all treatments were less than 1.0%, and the carbon dioxide and oxygen concentrations in packages were 6-8% and 16-17%, respectively for all treatments in the final storage day. The concentration of ethylene in the packages fluctuated between $1-3{\mu}L{\cdot}L^{-1}$ during the storage and the highest concentration of ethylene was observed at 6 hours plasma treatment in the final storage day. The off-odor of all treatments were almost odorless, the treatments of chlorine water and 1 hour plasma maintained the marketable visual quality until the end of storage. Chlorophyll content and Hue angle value measured at the final storage day were similar to those measured before storage in chlorine water and 1 hour of plasma treatments. E. coli was not detected immediately after sterilization in all sterilization treatments. After 6 hours of plasma treatment, the total bacteria fungus counts were lower than the domestic microbial standard for agricultural product in all sterilization treatments. The total aerobic counts in the end storage day increased compared to before storage, whereas E. coli was not detected in all sterilization treatments. The sterilization effect against bacteria and fungi was the best in chlorine water treatment. Plasma treatment showed sterilization effects, but within a prolonged period of time. In addition, the sterilization effect decreased gradually. These results suggest that chlorine water and plasma treatment were effective in maintaining Latuca indica L. baby Leaf commerciality and controlling microorganisms during postharvest storage.

Study on water quality prediction in water treatment plants using AI techniques (AI 기법을 활용한 정수장 수질예측에 관한 연구)

  • Lee, Seungmin;Kang, Yujin;Song, Jinwoo;Kim, Juhwan;Kim, Hung Soo;Kim, Soojun
    • Journal of Korea Water Resources Association
    • /
    • v.57 no.3
    • /
    • pp.151-164
    • /
    • 2024
  • In water treatment plants supplying potable water, the management of chlorine concentration in water treatment processes involving pre-chlorination or intermediate chlorination requires process control. To address this, research has been conducted on water quality prediction techniques utilizing AI technology. This study developed an AI-based predictive model for automating the process control of chlorine disinfection, targeting the prediction of residual chlorine concentration downstream of sedimentation basins in water treatment processes. The AI-based model, which learns from past water quality observation data to predict future water quality, offers a simpler and more efficient approach compared to complex physicochemical and biological water quality models. The model was tested by predicting the residual chlorine concentration downstream of the sedimentation basins at Plant, using multiple regression models and AI-based models like Random Forest and LSTM, and the results were compared. For optimal prediction of residual chlorine concentration, the input-output structure of the AI model included the residual chlorine concentration upstream of the sedimentation basin, turbidity, pH, water temperature, electrical conductivity, inflow of raw water, alkalinity, NH3, etc. as independent variables, and the desired residual chlorine concentration of the effluent from the sedimentation basin as the dependent variable. The independent variables were selected from observable data at the water treatment plant, which are influential on the residual chlorine concentration downstream of the sedimentation basin. The analysis showed that, for Plant, the model based on Random Forest had the lowest error compared to multiple regression models, neural network models, model trees, and other Random Forest models. The optimal predicted residual chlorine concentration downstream of the sedimentation basin presented in this study is expected to enable real-time control of chlorine dosing in previous treatment stages, thereby enhancing water treatment efficiency and reducing chemical costs.

Chlorine Disinfection in Water Treatment Plants and its Effects on Polyamide Membrane (수처리장에서의 염소살균처리가 폴리아마이드 분리막에 미치는 영향)

  • Jun, Byung-Moon;Yun, Eun-Tae;Han, Sang-Woo;Nguyen, Thi Phuong Nga;Park, Hyung-Gyu;Kwon, Young-Nam
    • Membrane Journal
    • /
    • v.24 no.2
    • /
    • pp.88-99
    • /
    • 2014
  • Demand for water is increasing due to rapid population growth and increased industrial activities. Membrane technologies have attracted most attention as a promising advanced technology for the supply of sustainable water resources. Chemical and structural properties of polyamide membranes, one of the most widely used membranes in water treatment plant, has been reported to be affected by residual chlorine dissolved in water after chlorine disinfection. This paper focuses on the chlorine speciation at various solution pHs and change of surface properties/performance of polyamide membranes due to the chlorine exposure.

Changes of Satsuma Mandarin Sacs during Storage (온주(溫州)밀감 sac의 저장중(貯藏中) 변화(變化))

  • Choi, Young-Bae;Kang, Dong-Sub;Kang, Yeung-Joo
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.16 no.3
    • /
    • pp.21-25
    • /
    • 1987
  • In order to obtain a basic understanding of the storage of Satsuma mandarin sacs, the canned sacs were stored at room temperature from Feb. 20 to June 20(4 months), after dipping in chlorine solution and pasteurization as a pretreatment before canning. In general, the brix, acidity and pH of the sacs were almost not affected by the chlorine treatment ana a variety of pasteurization temperatures during storage. The broken rate was apperently increased by chlorine treatment, especially in the early stage of storage. However, the broken sacs were partially recovered in the end of storage. The contents of total carotenoid were almost not decreased by the conditions of the pretreatments during storage. The contents of vitamin C were sharply decreased between 3rd and 4th month of storage time on all sample. As a result, the decrement of vitamin C in canned sacs was caused by storage temperature rather than the condition of the pretreament.

  • PDF

Microbiological Characterization and Chlorine Treatment of Buckwheat Sprouts (메밀 새싹채소의 주요 내재미생물 분석 및 염소처리에 따른 품질변화)

  • Lee, Hyun-Hee;Hong, Seok-In;Kim, Dong-Man
    • Korean Journal of Food Science and Technology
    • /
    • v.41 no.4
    • /
    • pp.452-457
    • /
    • 2009
  • In order to secure microbiological safety and quality of commercial vegetable sprouts, buckwheat seeds and sprouts were investigated for their microbiological flora and for the effect of chlorine treatment on quality. Microbiological analyses showed that major inherent bacteria including Enterobacter, Sphingomonas, and Klebsiella were found in commercial buckwheat sprouts with a population size ranging from $10^5$ to $10^7$ CFU/g. In addition, buckwheat seeds had a similar microbial flora to sprouts. Foodborne pathogenic bacteria such as Escherichia coli O157:H7, Staphylococcus aureus, Salmonella Typhimurium, and Listeria monocytogenes were not detected in the sprout or in the seed samples. Chlorine treatment with 50-150 ppm sodium hypochlorite noticeably reduced viable bacteria cell counts of the sprouts by about 1 log. However, no significant difference was observed among the different chlorine concentrations. After storage for 7 days at $5^{\circ}C$, the sprouts treated with 100-150 ppm chlorine showed higher sensory scores in visual quality than the others (p<0.05). The results indicated that proper pretreatment, such as dipping in chlorinated water, could confer a beneficial effect on the microbiological safety and visual quality of buckwheat sprouts.

Microbiological changes and quality characteristics of dried persimmon by chlorine dioxide gas fumigation treatment (이산화염소 가스 훈증 처리에 따른 곶감의 미생물학적 변화 및 품질특성)

  • Moon, Hey-Kyung;Lee, Su-Won;Lee, Wha Jin;Hossein, Abul;Lee, Seul;Kim, Jong-Kuk
    • Food Science and Preservation
    • /
    • v.24 no.5
    • /
    • pp.608-614
    • /
    • 2017
  • This study was conducted to investigate the effect of chlorine dioxide fumigation as a substitute for sulfur fumigation which has been used as a method to prevent the quality change of persimmon during storage and distribution process. Dried persimmons were treated with chlorine dioxide gas concentration (0, 15 30, and 45 ppm) and time (0, 15, 30, and 45 min) and microbiological changes, texture properties and color of the treated samples were investigated during storage at room temperature. Total aerobic bacteria, yeast and mold numbers after chlorine dioxide gas fumigation were decreased when compared with the control group. The inhibitory effects of total aerobic bacteria, yeast, and mold were observed during storage. The texture properties and color value of dried persimmons were not affected by chlorine dioxide gas fumigation concentration and time. There was no difference in quality between chlorine dioxide gas fumigation treatment group and control group. These results suggested that chlorine dioxide gas fumigation treatment can be utilized as a processing technique to secure microbiological storage stability of dried persimmons.

Removal of Odor and THM from the Raw Water of Daecheong Dam (대청호 원수내 냄새 및 THM 제거방안 연구)

  • Jeon, Hang-Bae;Yun, Gi-Sik
    • Journal of Korea Water Resources Association
    • /
    • v.30 no.3
    • /
    • pp.235-245
    • /
    • 1997
  • A pilot scale study for removing odor and trihalomethane formation potential (THMFP) was investigated in the standard water treatment plant equipped with ozone oxidation and granular activated carbon (GAC) adsorption processes. The removal efficiency of dissolved organic carbon (DOC) in the pilot scale standard water treatment process (PSWTP) was about 25%, however, no more removal in the ozone oxidation process. On a GAC after 30 days operation, DOC removal efficiency was about 75%. Odor removal efficiency was about 30% in PSWTP, 60% in ozone oxidation, and almost complete in well as DOC. Mid-1 and 2 that showed breakthrough in odor inducing material as well as DOC. Mid-1 and 2 chlorination was able to reduce trihalomethanes (THM) by 25% compared to prechloringation, while postchlorination alone could reduce them by 30%.

  • PDF

The Electrochemical Chlorination for Marine Plankton Community Disinfection (해양 플랑크톤 군집의 전기분해 염소소독 효과)

  • Kang, Jung-Hoon;Shin, Kyoung-Soon;Hyun, Bong-Gil;Jang, Min-Chul;Kim, Eun-Chan;Chang, Man
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.10 no.3
    • /
    • pp.127-137
    • /
    • 2007
  • To confirm whether or not the Electrochemical Disinfection System (EDS) meet with the D-2 regulation established by IMO (International Maritime Organization), the biological treatment efficacy of the EDS was assessed using three groups of natural marine plankton (bacteria, $10-50\;{\mu}m$ and $>50\;{\mu}m$ sized organisms). Influent water was passed through the EDS under the flow velocity ($23.8\;m^3/hr$) and test design was consisted of control (no treatment) and experimental (10 ppm and 30 ppm) condition for total residual chlorine (TRC). And the biological condition of the influent water followed the standards established by the guidelines for the approval of ballast water management systems. The disinfection efficacy of the $10-50\;{\mu}m$ sized organisms (phytoplankton) was assessed by three kinds of measurements using photomicroscope, epifluorescence microscope and fluorometer (fumer Designs 10-AU). After being passed through the EDS, all motile phytoplankton lost their motility under photomicroscope, the colour of chlorophyll fluorescence fumed from red into green under epifluorescence, and the high chlorophyll fluorescence (Expt. 1: 6.95, Expt. 2: 7.11) detected by fluorometer decreased into value not detected. These results indicated phytoplankton community was totally killed after electrochemical disinfection treatment. Survivorship of the larger organisms than $50\;{\mu}m$ was determined based on the appendage's movement under a stereomicroscope. Natural assemblage collected from ambient seawater was killed shortly after being passed through the EDS, whereas some Artemia remained alive. However, no live Artemia was found after 24 hour further exposure to each TRC concentration (10 and 30 ppm) under darkness. After electrochemical treatment, the target bacteria such as aerobes, coliform and Escherichia coli were completely killed on the basis of CFU (colony forming unit) on Petrifilm plate ($3\;M^{TM}$) after 48 hr incubation. Moreover, no regrowth was found in the three groups of plankton during five days under additional exposure to the treated water. These results indicated that the disinfection efficiency of the EDS on the three groups of plankton satisfy D-2 regulation.

  • PDF