• Title/Summary/Keyword: 염소제거

Search Result 244, Processing Time 0.026 seconds

Effects of Adsorption and Decomposition on the Removal of Total Organic Carbon (TOC) in Oil Wastewater by Cellulose-based Pseudo Graphene and Persulfate (셀룰로오스 기반 유사-그래핀과 과황산염에 의한 압연류 폐수내 총유기탄소(TOC) 흡착 및 분해효과 연구)

  • Song-I Kim;Ji-Young Shin;Kyung-Chul Park;Jae-Kyu Yang;Dong-Su Kim
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.32 no.3
    • /
    • pp.5-18
    • /
    • 2024
  • Chemical oxygen demand (COD), an organic material measurement index, has a limit to the management of the total amount of all organic materials including non-degradable organic materials due to low oxidation rate. So total organic carbon (TOC) that can measure organic materials more accurately is introduced and used as a measurement index. Several environmental companies including company A in Gyeonggi-do dilute raw wastewater first and then treats it with chemicals. And an activated carbon is used at the rear stage to treat total organic carbon even though various treatment processes can be applied to reduce TOC in wastewater. There are some problems such as use of a lot of diluting water and generation of an excessive amount of sludge, so it is urgent to come up with an alternative plan. Therefore, in this study, an application experiment was conducted on two different methods for improving the TOC reduction efficiency of waste water from Company A. The first method is the evaluation of the substitution potential of powered activated carbon(PAC), an adsorbent currently used, by manufacturing cellulose-based graphene like carbon (CGLC). This first study showed that CGLC had about 10% higher TOC adsorption efficiency than commercial PAC, showing the possibility of being applied as an alternative adsorbent for PAC in water treatment sites. The second method relates to the removal of TOC by sulfate radials produced by persulfate (PS) activation. Two activation methods were applied: using CGLC and PAC as carbon-based catalyst and using the high temperature of wastewater for PS activation. As a result of using PAC and CGLC as PS activation materials, the TOC removal rate was lower than the adsorption amount of TOC by CGLC and PAC due to excessive chlorine ions present in the real wastewater. However, as a result of using the high water temperature (55~60℃) of the field wastewater for PS activation, it showed a much greater TOC removal efficiency than PAC alone, CGLC alone, and using a carbon-based catalyst for PS activation. When PS was injected more than 0.5%, it showed a TOC removal efficiency of 95% or more within 24 hr. In addition, when PS was injected more than 0.3%, the TOC concentration could be lowered to less than 75 ppm, which is the wastewater discharge standard applied to company A. When these results were summarized, raw wastewater of high temperature can be treated with a simple process of only adding of PS and discharged by treating TOC below the wastewater discharge standard applied to company A.

Durability Extension of Fe(0) Column with Shewanella Algae BrY on TCE Treatment (Shewanella algae BrY를 이용한 영가철 칼럼의 TCE 처리 수명연장)

  • Chae, Heehun;Bae, Yeunook;Park, Jae-Woo
    • Journal of the Korean GEO-environmental Society
    • /
    • v.8 no.2
    • /
    • pp.41-48
    • /
    • 2007
  • Zevo-valent iron (ZVI) has been widely used in permeable reactive barriers for reducing organic contaminants, such as trichloroethylene (TCE). The rapid reaction time, however, leads to decrease in reactivity and availability of ZVI. Shewanella algae BrY, a strain of dissimilatory iron reducing bacteria, can reduce the oxidized Fe (III) to Fe (II) and reduced Fe (II) can be reused to reduce the contaminant. The effect of Shewanella algae BrY on the reduction of the oxidized ZVI column and further TCE removal in the contaminated groundwater were studied at different flow rates and TCE input concentrations in this study. High input concentration of TCE and flow rate increase the amount of input contaminant and make to lower the effect of reduction by Shewanella algae BrY. Specially, the fast flow rate inhibits the direct contact and implantation on the surface of iron. The reduction of oxidized iron reactive barrier by Shewanella algae BrY can decrease the decreation of duration of PRBs by the precipitation of oxidized iron produced by dechlorination of TCE.

  • PDF

Distribution and Risk Assessment of Bisphenol-A in Tap Water from Rehabilitated Indoor Water Service Pipe (갱생 옥내급수관 수돗물에서 비스페놀-A 분포 및 위해성 평가)

  • Jeong, Gwanjo;Son, Boyoung;Lee, Inja;Ahn, Chihwa;Kim, Junil;Moon, Boram;Lee, Suwon;Ahn, Jaechan;Kim, Bogsoon;Chung, Deukmo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.38 no.7
    • /
    • pp.371-376
    • /
    • 2016
  • In this study, the survey of bisphenol-A in indoor water service pipes rehabilitated with epoxy resin was conducted and the risk assessment was done to investigate the effect on the human health to drink tap water. Bisphenol-A in raw water was detected in a range of 50~118 ng/L in all samples, where the limit of quantification was 10 ng/L. This is caused by inflow of the sewage effluent or the tributaries of the surrounding area containing bisphenol-A. Bisphenol-A was not detected in finished water after the advanced water treatment process. It was achieved by its removal from the processes of flocculation-precipitation and oxidation of ozone and chlorine and by being changed to other by-product materials. For the indoor water service pipe, bisphenol-A was not detected in all cases which was not coated with epoxy resin. However, when epoxy resin is lined within the indoor water service pipe, bisphenol-A was identified at maximum level of 521 ng/L and was detected above the limit of quantitation at 68 percentages of all samples. The Hazard Quotient (HQ) at the maximum level (521 ng/L) of the detected bisphenol-A is 0.004, which is less than the reference value of 0.1 for the tap water intake. Therefore, it is considered that the detected levels of bisphenol-A in this study would be safe to drink tap water.

Neutral Electrolyzed Water for Prevention of Dental Caries (기존 구강청결제를 대체할 수 있는 치아우식 예방을 위한 전기분해수)

  • Lee, Kyam
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.43 no.3
    • /
    • pp.306-312
    • /
    • 2016
  • Gargle solution has typically been used for the prevention of oral infectious disease such as dental caries and periodontitis. However, the use of most gargle solutions is controversial in application for children because some gargle solutions have harmful side effects. Electrolyzed water is generated by passed an electric current and has antimicrobial activity. The purpose of this study was to investigate and compare the efficacy of electrolyzed water in various conditions for eliminating cariogenic bacteria. Electrolyzed water was generated by a platinum electrode in the presence of sodium chloride at various concentrations. Streptococcus mutans and Streptococcus sobrinus were cultivated into a brain heart infusion broth. After harvesting planktonic bacteria, the pellets were treated with the electrolyzed water and commercial gargle solutions and plated on a mitis-salivarius agar plate. Also, the anti-biofilm activity of the electrolyzed water and commercial gargle solutions was investigated after biofilm formation of S. mutans and S. sobrinus. The bacteria in the biofilm were plated onto a mitis-salivarius agar plate. The plates were incubated, and the colony forming unit was measured. The electrolyzed water containing sodium chloride showed significant antibacterial activity against S. mutans and S. sobrinus as well as some gargle solutions. Furthermore, the electrolyzed water had more disruptive effect on the biofilm of S. mutans and S. sobrinus and killed more bacteria in the biofilm than commercial gargle solutions. The results demonstrate that electrolyzed water may be a useful gargle solution for prevention of dental caries.

Improvement of Rectangle Sedimentation basin using the Moving Baffle (이동식 정류장치를 이용한 횡류식 침전지 침전효율 개선 연구)

  • Cho, Young-Man
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.7
    • /
    • pp.726-731
    • /
    • 2005
  • Sedimentation is treated as the most important unit process in waterworks, and plays great role on turbidity removal efficiency. Rectangle sedimentation basin is the most widely accepted sedimentation process. But it has some problems with short-circuit flow and density flow caused by temperature and influent turbidity variation. To solve these problems, installation of rectification wall was suggested, but not generally fully accepted in field. Because hole of rectification wall cause jet flow. In this research, use of moving baffle was investigated. Moving baffle was designed to induce uniform velocity at every section of water flow. The baffle walls was made from soft fiber materials. The baffle walls with flow of sedimentation basin moves at same speed. It is like that it controls density flow and short-circuit flow and induce uniform velocity at every section of water flow in sedimentation basin. When moving baffle was operated retention time of sedimentation basin was extended to 1 hours. When it talked again and the effluent time of highest concentration of the chlorine ion from 100 minutes was extended to 160 minutes. Turbidity removal efficiency was tested with different operation modes(continuous and batch) with influent turbidity and retention time. It was revealed that turbidity removal efficiency carl be improved up to 36%(continuous mode) and 58%(batch mode) respectively. Consequently if moving baffle introduces in Rectangle sedimentation basin, it forecasts that the turbidity improvement above 30% will be possible.

Molecular Cloning and Expression in Escherichia coli of a Rabbit Globin Gene (유전공학적 방법에 의한 토끼 글로빈 유전자의 재조합과 대장균에서의 발현)

  • Jang, Sung-Key;Park, Hyune-Mo
    • The Korean Journal of Zoology
    • /
    • v.27 no.2
    • /
    • pp.103-116
    • /
    • 1984
  • The structural gene of rabbit hemoglobin was cloned into Pst I site of pBR322 in E. coli. The complementary DNA (cDNA) was synthesized from rabbit globin mRNA with avian myeloblastosis viral reverse transcriptase, and then RNA was destroyed at pH 11. The double stranded cDNA was synthesized with both Klenow fragment of E. coli DNA polymerase I and reverse transcriptase and then the hairpin loop was opened with Sl nuclease. Double stranded cDNA was subsequently tailed with dCTP and annealed to dGMP-tailed vector DNA. After transformation and initial screening of appropriate clones by plasmid size, the cloned colonies were identified by in situ colony hybridization using by plasmid size, the cloned colonies were identified by in situ colony hybridization using $[^32P]$-labeled cDNA probes and characterized the inserts with restriction endonucleases. The expression of cloned globin gene was investigated by standard radioimmunoassay using rat anti-rabbit Hb serum as primary antibody and goat antirat IgG serum as secondary antibody. The result suggested that the chimeric proteins (the part of $\\beta$-lactamase from the vector pBR322 and globin from rabbit) were supposedly produced in E. coli and the product had the antigenic determinant of rabbit hemoglobin.

  • PDF

Disinfection Methods of Pruning Scissor for Preventing Transmission of Fire Blight (과수 화상병 전염 차단을 위한 전정 가위 소독 방법)

  • Yeon-Jeong Lim;Hyeonheui Ham;Mi-Hyun Lee;Woohyung Lee;Yong Hwan Lee
    • Research in Plant Disease
    • /
    • v.30 no.2
    • /
    • pp.194-198
    • /
    • 2024
  • Pathogens of fire blight can survive for a long time on pruning tools, etc., and fire blight can be spread through agricultural implements. In particular, in Korea, pruning is frequently performed to remove flowers, immature fruits, and succulent shoots, and this farm work is known to be a major factor of the spread of fire blight. Therefore, in this study, in order to completely sterilize pathogens on pruning shears, we verified the disinfection effect of disinfectants distributed domestically and used them to identify an effective disinfection method. When disinfecting by immersion after inoculating Erwinia amylovora TS3128 on the scissor blade, 70% ethanol and 1% and 0.2% sodium hypochlorite sterilized immediately 10 sec after immersion, while 30% chlorine dioxide showed little disinfection effect. When disinfecting by spraying, 70% ethanol sterilized bacteria 1 sec after spraying, but 1% and 0.2% sodium hypochlorite disinfected bacteria after 10 and 60 sec, respectively. After cutting the naturally disease occurring branches five and 100 times, the bacteria were not hardly sterilized in immersion treatment in 70% ethanol for 30 sec but perfectly disinfected over 60 sec. Considering these results, pruning shears should be disinfected by frequently immersing them in 70% ethanol for at least 60 sec during pruning work in the field.

Evaluation of Cryptosporidiurn Disinfection by Ozone and Ultraviolet Irradiation Using Viability and Infectivity Assays (크립토스포리디움의 활성/감염성 판별법을 이용한 오존 및 자외선 소독능 평가)

  • Park Sang-Jung;Cho Min;Yoon Je-Yong;Jun Yong-Sung;Rim Yeon-Taek;Jin Ing-Nyol;Chung Hyen-Mi
    • Journal of Life Science
    • /
    • v.16 no.3 s.76
    • /
    • pp.534-539
    • /
    • 2006
  • In the ozone disinfection unit process of a piston type batch reactor with continuous ozone analysis using a flow injection analysis (FIA) system, the CT values for 1 log inactivation of Cryptosporidium parvum by viability assays of DAPI/PI and excystation were $1.8{\sim}2.2\;mg/L{\cdot}min$ at $25^{\circ}C$ and $9.1mg/L{\cdot}min$ at $5^{\circ}C$, respectively. At the low temperature, ozone requirement rises $4{\sim}5$ times higher in order to achieve the same level of disinfection at room temperature. In a 40 L scale pilot plant with continuous flow and constant 5 minutes retention time, disinfection effects were evaluated using excystation, DAPI/PI, and cell infection method at the same time. About 0.2 log inactivation of Cryptosporidium by DAPI/PI and excystation assay, and 1.2 log inactivation by cell infectivity assay were estimated, respectively, at the CT value of about $8mg/L{\cdot}min$. The difference between DAPI/PI and excystation assay was not significant in evaluating CT values of Cryptosporidium by ozone in both experiment of the piston and the pilot reactors. However, there was significant difference between viability assay based on the intact cell wall structure and function and infectivity assay based on the developing oocysts to sporozoites and merozoites in the pilot study. The stage of development should be more sensitive to ozone oxidation than cell wall intactness of oocysts. The difference of CT values estimated by viability assay between two studies may partly come from underestimation of the residual ozone concentration due to the manual monitoring in the pilot study, or the difference of the reactor scale (50 mL vs 40 L) and types (batch vs continuous). Adequate If value to disinfect 1 and 2 log scale of Cryptosporidium in UV irradiation process was 25 $mWs/cm^2$ and 50 $mWs/cm^2$, respectively, at $25^{\circ}C$ by DAPI/PI. At $5^{\circ}C$, 40 $mWs/cm^2$ was required for disinfecting 1 log Cryptosporidium, and 80 $mWs/cm^2$ for disinfecting 2 log Cryptosporidium. It was thought that about 60% increase of If value requirement to compensate for the $20^{\circ}C$ decrease in temperature was due to the low voltage low output lamp letting weaker UV rays occur at lower temperatures.

A History of Termite Control and Improvements to Prevent Termites in Wooden Architectural Heritage (국내외 흰개미 방제 기술의 발달 과정과 목조건축문화재의 흰개미 피해 저감을 위한 방안)

  • LEE, Sangbin;IM, Ikgyun;KIM, Sihyun
    • Korean Journal of Heritage: History & Science
    • /
    • v.54 no.2
    • /
    • pp.194-215
    • /
    • 2021
  • Termites are important decomposers in the ecosystem. They are also economically significant structural pests. In this study, we reviewed the developments of termite control and recent research on termite management to provide information on the prevention and control of termites. In Korea, most of the damage to wooden historical buildings is caused by subterranean termites. Reticulitermes speratus kyushuensis is the main species, which is widely found throughout the country. In the early 1900s, inorganic insecticides, such as arsenic dust, were used for termite control. After the synthesis of chlorinated hydrocarbon pesticide in the 1940s, it was widely utilized and demonstrated high termite control efficacy. However, chlorinated hydrocarbon insecticides were later banned, disappearing from markets after reports emerged concerning environmental contamination and toxicity to humans. Therefore, the termite control industry sought a new termiticide; hence many pesticides were utilized for termite control. Organophosphate (1960s), carbamate (1970s), pyrethroid, and insect growth inhibitor (1980s) were newly synthesized and adopted. In the 1990s, the first commercial baits using chitin synthesis inhibitors (CSI) were developed, providing a means to eliminate an entire colony of subterranean termites around a structure. Many studies have been carried out on soil termiticides (liquid termiticides) and CSI baits to increase their efficacy, and different baits such as aboveground bait stations, fluid bait, and high-durability bait were also developed in the 2000s. In addition, the paradigm of termite control has shifted from localized treatments using soil termiticides to area-wide pest management using CSI baits to create termite-free zones and protect buildings over time. Termite infestations in wooden historical buildings in Korea have been reported since 1980, and considerable attention was drawn in the 1990s when several UNESCO world heritages such as the Jongmyo Shrine and the Janggyeong Panjeon Depositories of Haeinsa Temple were infested by subterranean termites. Since then, a survey of termite infestation in wooden architectural heritage has been conducted, and the National Research Institute of Cultural Heritage and Heritage Care Program regularly monitors those properties. Finally, we suggest termite management using primarily CSI baits, selective application of various soil treatments applied to the object, foundation soil treatment, research and development of durable termite baits, application of area-wide programs for wooden-building complexes, application of integrated termite management (ITM), and regular education for owners and managers to prevent and reduce termite damage.

Evaluation of Cleaning ability and Environmental Evaluation of Commercial Aqueous/Semi-aqueous Cleaning Agents (시판 수계/준수계 세정제의 세정성 및 환경성 평가 연구)

  • Cha, A.J.;Park, J.N.;Kim, H.S.;Bae, J.H.
    • Clean Technology
    • /
    • v.10 no.2
    • /
    • pp.73-87
    • /
    • 2004
  • In most of industrial fields, cleaning is employed for removing soils on their products or parts. Halogenated cleaning agents such as CFC-113, 1,1,1-TCE(1,1,1-trichloroethane), MC(methylene chloride) and TCE (trichloroethylene) have been used as cleaning ones in most of companies in the world since their excellent performance of cleaning ability and good material compatibility. However, CFC-113 and 1,1,1-TCE which are ozone destruction substances are not used any more in the advanced countries because of the which are ozone destruction substances are not used any more in the advanced countries because of the Montreal protocol. MC and TCE are now used restrictively at small part of industrial fields in most of countries since they are known to be hazardous or carcinogenic materials. Thus, it is indispensible that the alternative cleaning agents which are environmental-friendly and safe, and show good cleaning ability should be developed or utilized for replacement of the halogenated cleaning agents. Aqueous/semi-aqueous cleaning agents are evaluated to be promising alternative ones among various alternatives in environmental and economical view point. In this study, commercially available 12 aqueous and 6 semi-aqueous cleaning agents were selected and their physical properties, cleaning abilities, rinsing abilities and recycling of contaminated rinse water were measured and analyzed. Aqueous cleaning agents with higher wetting index showed better cleaning ability compared with those with lower wetting index. However wetting index did not have any correlation with cleaning ability in semi-aqueous cleaning agents. It was observed that soil concentration in aqueous and semi-aqueous cleaning agents should be maintained below the certain concentrations which depend on types of clearing agents. More than 70% soils in contaminated rinse water by some of aqueous and semi-aqueous clearing agents could be separated by simple settling method. This means that some cleaning agents with high oil-water separation efficiency will be effiective for recycling oil-contaminated rinse water. It was found that contaminated rinse water with aqueous agents was purified easiy by ultrafiltration method with PAN membrane of 30 kDa.

  • PDF