• Title/Summary/Keyword: 염소가스

Search Result 147, Processing Time 0.048 seconds

Simultaneous Removal of Mercury and NO by Metal Chloride-loaded V2O5-WO3/TiO2-based SCR catalysts (금속염화물이 담지된 V2O5-WO3/TiO2 계 SCR 촉매에 의한 수은 및 NO 동시 제거)

  • Ham, Sung-Won
    • Clean Technology
    • /
    • v.23 no.2
    • /
    • pp.172-180
    • /
    • 2017
  • Thermodynamic evaluation indicates that nearly 100% conversion of elemental mercury to oxidized mercury can be attained by HCl of several tens of ppm level at the temperature window of SCR reaction. Cu-, Fe-, Mn-chloride loaded $V_2O_5-WO_3/TiO_2$ catalysts revealed good NO removal activity at the operating temperature window of SCR process. The catalysts with high desorption temperature indicating adsorption strength of $NH_3$ revealed higher NO removal activity. The HCl fed to the reaction gases promoted the oxidation of mercury. However, the activity for the oxidation of elemental mercury to oxidized mercury by HCl was suppressed by $NH_3$ inhibiting the adsorption of HCl to catalyst surface under SCR reaction condition containing $NH_3$ for NO removal. Metal chloride loaded $V_2O_5-WO_3/TiO_2$ catalysts showed much higher activity for mercury oxidation than $V_2O_5-WO_3/TiO_2$ catalyst without metal chloride under SCR reaction condition. This is primarily attributed to the participation of chloride in metal chloride on the catalyst surface promoting the oxidation of elemental mercury.

A Study on the Activated Carbon Injection and Filtration Process for Removal of Chlorinated Organic Compound in the Incinerator Flue Gas (활성탄의 분무 여과에 의한 소각로 배가스 중의 유기 염소계 화합물의 제거 공정 연구)

  • Choo, Changupp;Whang, Jaedong;Lee, Joyoung;Cho, Chulhoon;Shin, Byungchul
    • Clean Technology
    • /
    • v.6 no.2
    • /
    • pp.113-119
    • /
    • 2000
  • Due to the toxicity of dioxin in the incinerator flue gas, it becomes a severe social problem. Activated carbon adsorption process is one of the methods for removing dioxin in the flue gas and was investigated its performance for removing hazardous organic compounds. Since dioxin is very hazardous material, 1,2-dichlorobenzene(o-DCB), one of the precursor material of dioxin, was used as adsorbate. The effects of air flow rate, pressure drop in the bag filter, operation temperature of bag filter, and kinds of adsorbents on the removal of o-DCB were measured and analysed. Experimental results showed that the operating temperature was recommended within the range of $140{\sim}170^{\circ}C$ considering the operating condition of incinerator. Also it was necessary to maintain the pressure drop of bag filter $120mmH_2O$ for enhancing the adsorption at the surface layer of activated carbon formed on the bag filter. The use of mixture of same amount of activated carbon and diatomite showed more than 90% removal of o-DCB and also reduced the consumption of activated carbon.

  • PDF

Recovery of Metallic Pd with High Purity from Pd/Al2O3 Catalyst by Hydrometallurgy in HCl (염산 침출용액을 이용한 Pd/Al2O3 촉매에서 고순도 팔라듐 회수)

  • Kim, Ye Eun;Byun, Mi Yeon;Baek, Jae Ho;Lee, Kwan-Young;Lee, Man Sig
    • Clean Technology
    • /
    • v.26 no.4
    • /
    • pp.270-278
    • /
    • 2020
  • Palladium (Pd) has been widely used in various industrial applications such as jewelry, catalyst, and dental materials despite its limited resources. It has been gaining attention to recover Pd with high purity from the spent materials. This study investigated the optimum conditions for the leaching and recovery of metallic Pd. The leaching parameters are HCl concentration, temperature, time, concentration of oxidants, and pulp density. 97.2% of Pd leaching efficiency was obtained in 3 M HCl with 3 vol% oxidants at 80℃ for 60 min. The ratio of hydrogen peroxide to sodium hypochlorite played a critical role in the leaching efficiency due to the supply of Cl- ions in the leachate. Moreover, the complete recovery of Pd in the leachate was achieved at 80℃ with 0.3 formic acid/leachate after adjusting the pH value of 7. This situation was ascribed to the decomposition of formic acid into hydrogen gas and carbon dioxide at 80℃. ICP-AES and XRD characterized the recovered Pd powder, and the purity of the recovered powder was found to be 99.6%. Consequently, the recovered Pd powder with high purity could be used in circuits, catalyst precursors, and surgical instruments.

Evaluation of human exposure to polychlorinated biphenyls using human serum by congener-specific analysis (혈액 중 PCBs 이성질체별 분석에 의한 인체 노출 평가)

  • Park, Hyo-Keun;Lee, Se-Jin;Jin, Guang-Zhu;Kang, Jung-Ho;Baek, Song-E;Chang, Yoon-Seok
    • Analytical Science and Technology
    • /
    • v.19 no.1
    • /
    • pp.73-85
    • /
    • 2006
  • Blood serum concentrations of polychlorinated biphenyls (PCBs) were measured in employees who worked at a municipal solid waste incinerator (MSWI), members of residential community who lived near the MSWI (<0.3km) and members of residential community lived far from the MSWI (>10 km). Human blood serum samples were analyzed for all PCB congeners using high-resolution gas chromatography/high-resolution mass spectrometry (HRGC/HRMS). The mean levels of total PCBs and dioxin-like PCBs in 87 serum samples were 242.77 ng/g lipid and 8.83 TEQ pg/g lipid, respectively. The PCB homologue profiles showed that penta-, hexa-, hepta-chlorinated biphenyls contributed more than 80% of the total PCBs concentration. The most abundant congeners were PCB153, PCB138, PCB180, PCB187, PCB118. A statistical analysis was performed to determine whether there were significant correlations between PCB concentrations and specific variables such as age, gender, smoking habits, occupation, BMI (Body Mass Index) and time of residence. As a result, the age was found to be strongly correlated with serum PCB concentrations. In addition, there were strong correlations between total PCBs and PCB153 (r=0.93, p<.0001), dioxin-like PCBs and PCB118 (r=0.98, p<.0001). So these two congeners are satisfactory indicators for total PCB concentrations and dioxin-like PCBs in human blood respectively.

Microbe and Quality Changes of Ready-to-Eat Lettuce during Storage at Different Temperatures (신선편이 양상추의 온도별 저장 중 미생물과 품질변화)

  • Cho, Sun-Kyung;Kwon, Hye-Soon;Park, Jong-Hyun
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.39 no.12
    • /
    • pp.1867-1872
    • /
    • 2010
  • Microbe and quality changes of vacuum-packaged ready-to-eat lettuce were analyzed. While the vacuumpackaged lettuce after chlorine sanitizer were stored at $5^{\circ}C$, $15^{\circ}C$, and $25^{\circ}C$ for 7 days, viable numbers of total aerobic bacteria (TAB), coliform, E. coli, food-borne pathogens and lactic acids bacteria (LAB) were counted with gas production and sensory evaluation. Before the storage, only TAB of 2 log CFU/g and coliform of 1 log CFU/g were detected and LAB was not detected. TAB, coliform and LAB increased by 1 log CFU/g at $5^{\circ}C$ for 7 days without any detection of the pathogens. Sensory evaluations for off-flavour and crispness dropped to half the best value at 5 day storage. TAB and coliform increased by 3 log CFU/g and 2 log CFU/g, respectively, but LAB grew very actively by 4 log CFU/g under anaerobic environment and only B. cereus were detected after enrichment of the lettuce at $15^{\circ}C$ for 3 days. The evaluations for off-flavour and crispness were half the best value for 3 days. However, TAB and coliform increased by 3 log CFU/g, 1 log CFU/g, and 4 log CFU/g, respectively only at 1 day storage under $25^{\circ}C$. Also B. cereus were detected after enrichment and the sensory evaluation were half the best value within 1 day storage. Therefore, preservation at the lowest temperature possible is required for growth inhibition of the bacteria contaminated in the lettuce. Interestingly, LAB among them grew most actively under the anaerobic condition and the adulteration of lettuce might be closely related with the growth of LAB.

Effects of Chlorine dioxide ($ClO_{2}$) Gas Treatment on Postharvest Quality of Grapes (포도의 Chlorine Dioxide Gas 훈증처리 및 저장방법에 관한 연구)

  • Chang, Eun-Ha;Chung, Dau-Sung;Choi, Jong-Uck
    • Food Science and Preservation
    • /
    • v.14 no.1
    • /
    • pp.1-7
    • /
    • 2007
  • This study was conducted to determine if chlorine dioxide ($ClO_{2}$) gas might minimize microbial contamination of fresh produce. After exposing grapes to 20 ppm or 40 ppm of chlorine dioxide gas in a closed container, grapes treated with 20 ppm $ClO_{2}$ were packaged in Ny/PE/L-LDPE pouches, stapes treated with 40 ppm $ClO_{2}$ were placed in an empty corrugated box, and untreated control grapes were placed in a box with a sachet containing $ClO_{2}$ gas adsorbed to silica gel (a silica gel pad). The free volume of the sachet material allowed the release of $ClO_{2}$ gas into the headspace of packages containing fresh grapes. Control fruit not exposed to $ClO_{2}$, was placed in a box and stored at either $25^{\circ}C$ or $0^{\circ}C$. Fruit in Ny/PE/L-LDPE film treated with 20 ppm $ClO_{2}$ lost almost no weight during storage at either $25^{\circ}C$ or $0^{\circ}C$. Such fruit had a lower soluble solid content than did other fruit samples. Titratable acidity tended to fall rapidly during storage at either $25^{\circ}C$ or $0^{\circ}C$. Anthocyanin content of grapes decreased over 21 days at $25^{\circ}C$ but increased over 10 weeks at $0^{\circ}C$. The total microbial count of grapes treated with $ClO_{2}$ gas and silica gel pads were lower than controls at $25^{\circ}C$. Fruit treated with 20 ppm $ClO_{2}$ and packaged in Ny/PE/L-LDPE pouches had lower microbial counts than other fruit samples when stored at $0^{\circ}C$. The silica gel pad did not significantly improve total microbial count (compared to untreated control samples) at $0^{\circ}C$. This result may be attributed to a higher rate of diffusion of $ClO_{2}$ gas at room temperature.

Disinfection State and Effective Factors of Utensils & Equipments Used to Foodservice of Elementry Schools in Busan (부산지역 초등학교 급식기구 재질별 소독실태 및 영향 요인)

  • 김이선;전영수;한지숙
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.30 no.5
    • /
    • pp.969-977
    • /
    • 2001
  • The purpose of this study was to investigate disinfection state and effective factors of utensils and equipments used to foodservice of elementary schools in Busan area, The questionnaire which was administered to 160 dietitians was used in this study as a survey method. The results were as follows. The disinfection method of tray was mainly used by electric gas. Table and other products of stainless steel sanitized by sodium hypochlorite and hot water, but above 51% of slicer. grinder and peeler were not sanitized after used. The products of wood and plastic also used mainly sodium hypochlorite and hot water as sanitizers. In disinfection time, knife, wood spoon and plastic products should be sanitized on demand, but 30.9~53.5% of this utensils except rice scoop were sanitized on demand that showed deficiency of cognition for sanitation. The disinfection of most of utensils and equipments was conducted every day, but food case, slicer, peeler, grinder and wood spoon showed lower disinfection frequency than other products, The method of disinfection was related to dietitians age and career number of total serving, duration of foodservice and serving place, The disinfection time was also affected by dietitians age and educational level, and serving place. The disinfection frequency was affected by number of employee, number of total serving and duration of foodservice. Therefore based on the results of this study, it should be given to the microbiological study on disinfection method of utensils such as slicer, grinder, peeler, large spoon, plastic prouducts and the dietitians sanitation training also should be conducted continuously.

  • PDF