• Title/Summary/Keyword: 염소가스

Search Result 147, Processing Time 0.024 seconds

Synthesis of Low Concentration of NaOH Solution using $Na^+$ ion in the Concentrated Water from Membrane Separation Process (분리막 농축수에 포함된 Na를 이용한 저농도 NaOH 용액의 합성)

  • Lee, Yoon-Ji;Park, Youn-Jin;Choi, Jeong-Hak;Shin, Won-Sik;Choi, Sang-June;Chon, Uong
    • Korean Chemical Engineering Research
    • /
    • v.49 no.6
    • /
    • pp.810-815
    • /
    • 2011
  • Concentrated water discharged from seawater desalination process contains a high concentration of $Na^+$ ion. Electrolysis was applied to synthesize NaOH solution from the highly concentrated NaCl solution. The effect of various operating parameters of composited laboratory-scale chlor-alkali (CA) membrane cell was investigated. The operating parameters such as membrane types (CIMS and Nafion membranes), pretreatment of the membrane, flow rate (73 mL/min~200 mL/min), initial $Na^+$ ion concentration (1.5 M, 3M and 5 M) and current (1.5A and 2A) were evaluated. It was observed that synthesis efficiency of NaOH solution with CIMS membrane was higher than that with Nafion membrane, but the durability of CIMS membrane on $Cl_2$ gas was poor. The synthesis efficiency of NaOH solution increased with increasing initial $Na^+$ ion concentration and current, while the efficiency decreased with increasing flow rate using Nafion membrane.

Characteristics of RDF Char Combustion in a Bubbling Fluidized Bed (기포 유동층 내에서 RDF 촤의 연소 특성)

  • Kang, Seong-Wan;Kwak, Yeon-Ho;Cheon, Kyoung-Ho;Park, Sung Hoon;Jeon, Jong-Ki;Park, Young-Kwon
    • Applied Chemistry for Engineering
    • /
    • v.22 no.4
    • /
    • pp.429-432
    • /
    • 2011
  • The feasibility of applications of the char obtained from a gasification process of municipal-waste refuse derived fuel (RDF) as an auxiliary fuel was evaluated by combustion experiments. The higher heating value of the RDF char was 3000~4000 kcal/kg and its chlorine content was below the standard requirement demonstrating its potential as an auxiliary fuel. In the combustion exhaust gas, the maximum $NO_x$ and $SO_2$ concentrations were 240 ppm and 223 ppm, respectively. If an aftertreatment is applied, it is possible to control their concentrations low enough to meet the air pollutant emission standard. The HCl concentration was relatively high indicating that a care should be taken for HCl emission from the combustion of RDF. Based on the temperature distribution within the reactor, the concentration change of $O_2$ and $CO_2$, and the amount and the loss on ignition of solid residue, it was inferred that the combustion reaction was the most reliable when the excess air ratio of 1.3 was used.

Analysis of Dioxins and Furans from Bottom Ash Produced in an Municipal Solid Waste Incinerator (도시 소각로 시설의 고형 쓰레기 연소 후 생성된 바닥재 시료에 대한 다이옥신과 퓨란류의 분석)

  • Chang, Yoon-Seok;Hong, JongKi;Kim, Jin-Young
    • Journal of the Korean Chemical Society
    • /
    • v.39 no.7
    • /
    • pp.513-523
    • /
    • 1995
  • Polychlorinated dibenzo-p-dioxins (PCDDs) and dibenzofurans (PCDFs) are the most concerned toxic organic pollutants to human. Because of their extremely high toxicity and uncertain genotoxic potential, their determination in environmental and biological samples is of great interest. Municipal solid waste incinerator facilities have been reported as the major contributors of dioxins and furans to the environment, and their formation from combustion is a universal phenomenon, everywhere. In this study dioxins and furans were analyzed from the bottom ash produced during combustion in an municipal waste incinerator located in Seoul. The EPA method was modified for sample pretreatment: the soxhlet method was used for extraction and clean-up procedures were performed by using silica and basic alumina, excluding active-carbon. The extract was then analyzed by HRGC/HRMS. A general trend of increase in the amounts of 6∼7 chlorine-substituted dioxins and furans was observed. Total dioxins, furans and 2,3,7,8-TCDD were determined as 8.05 ng/g, 4.75 ng/g, and 6.93 pg/g, respectively.

  • PDF

Removal and Decomposition of Organochlorine Compounds in Water Using UV Irradiation (자외선에너지를 이용하여 물속에 함유된 유기염소계 화합물의 분해 및 제거)

  • Kim, Jong Hyang
    • Applied Chemistry for Engineering
    • /
    • v.10 no.1
    • /
    • pp.30-34
    • /
    • 1999
  • Photolysis behavoirs of pesticides(Chlorothalonil and Endosulfan) over UV irradiation UV irradiation with pH 3.0 and irradiation with 3.5% salt were studied. The analyses of pesticides were carried out using gas chromatograph with an electron-capture detector, total organic carbon, and Ion chromatograph, respectively. The reactions were conducted in a alumium annular reactor equipped with a low pressure mercury multilamp ($8W{\times}6$) and initial concentration was 10 ppm. Chlorothalonil was almost photodegraded by UV irradiation, UV irradiation with pH 3.0 and 3.5% salt within 30 min of reaction time. Endosulfan-${\alpha}$,${\beta}$(100%) were photodegraded to 38% of Endosulfan-${\alpha}$ and 25% of Endisulfan-${\beta}$ by UV irradiation. Endosulfan-${\alpha}$(83%) was photodegraded to 66% by UV irradiation, 70% by UV irradiation and pH 3.0 and 75% by UV irradiation and 3.5% salt. Endosulfan-${\beta}$(16%) was photodegraded to 80% by UV irradiation, 98% by UV irradiation and pH 3.0 and 90% by UV irradiation and 3.5% salt.

  • PDF

The study of catalytic combustion of VOCs (휘발성 유기염소화합물의 촉매연소 연구)

  • Lee, Keon-Joo
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.14 no.1
    • /
    • pp.169-177
    • /
    • 2006
  • In this study, it was studied that the removal rate of VOC by the catalytic combustion. The combustion temperature was changed by the contact type of VOC(space velocity and catalyst depth) and the space velocity(SV) was defined by the rate of gas volume flow rate(Q, $m^3/hr$) over volume(V, $m^3$) of catalyst (SV=Q/V). The space velocity of catalytic combustor is maintained $10,000{\sim}50,000hr^{-1}$. it was studied that the conversion rate of VOC by the catalytic combustion. The combustion temperature was changed by the contact type of VOC and catalyst and the space velocity was defined by the rate of gas volume flow rate over volume of catalyst. The VOC which pass thru the heat exchanger was measured by the hydro ionic detector and measured the VOC removal rate by the activated catalyst in the reaction temperature range of 373K-423K. The removal rate was measured over 100 times. In the automobile painting booth The VOC concentration was 63.37ppm and the removal rate was 70 % at 373K and 78.92% at 423K. The removal rate was increased as increased the temperature.

  • PDF

Etch Rate Dependence of Differently Doped Poly-Si Films on the Plasma Parameters (플라즈마 변수에 의한 불순물주입 다결정실리콘 박막의 식각율 변화)

  • Park, Sung-Ho;Kim, Youn-Tae;Kim, Jin-Sup;Kim, Bo-Woo;Ma, Dong-Sung
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.25 no.11
    • /
    • pp.1342-1349
    • /
    • 1988
  • The dependence of the etch rates of differently doped poly-Si films on the gas composition, the chamber pressure and the RF power was investigated in detail. The highest anisotropy and the lowest CD loss were achieved at the $SF_6$-rich compositions, i.e., $Cl_2:SF_6$=17:33 (SCCM), in the $POCl_3$-doped poly-Si. The etch rates increased for n-type dopant (phosphorus), while decreased for p-type (boron) with increasing the doping levels irrespective of plasma parameters. And from the results of the activation of doped poly-Si films the active carrier concentrations as well as the doping concentrations were found to be responsible for the increase of the etch rate of the phosphorus-doped poly-Si.

  • PDF

Kinetics of the Low-temperature Pyrolysis of Mixed Plastics in the Batch Reactor (회분식반응기에서의 혼합 플라스틱의 저온열분해 kinetics)

  • Cha, Wang Seog;Oh, Myung Seog;Jang, Hyun Tae;Tae, Beomseok
    • Korean Chemical Engineering Research
    • /
    • v.46 no.3
    • /
    • pp.540-544
    • /
    • 2008
  • Pyrolytic characteristics of mixed plastics containing 22 wt.% HDPE, 17 wt.% LDPE, 27 wt.% PP, 12 wt.% PS, 16 wt.% ABS, 6 wt.% PVC have been studied in the batch-type microreactor of stainless steel. Thermal degradation experiments were performed at temperature of $410{\sim}450^{\circ}C$. The yield of each pyrolytic products were obtained by the weight measurement and molecular weight distribution of pyrolytic liquid products determined by the GC-SIMDIS method. It was shown that the yield and molecular weight of pyrolytic liquid product were decreased with the increase of reaction temperature and time. It was know that 20wt% of PVC composing of the mixed plastics was converted to the gas products of chloride during the pyrolysis process. The chain-end scission rate parameter was determined to be 50.2 kcal/mole of mixed plastics by the Arrhenius plot.

Research on the phenomenon of sick house syndrome and how to remove harmful gases (새집증후군 현상 및 유해가스 제거방안 연구)

  • Choe, Yoowha
    • The Journal of the Convergence on Culture Technology
    • /
    • v.6 no.3
    • /
    • pp.449-456
    • /
    • 2020
  • When you move to a new home, or when you change the wallpaper or flooring of your home, office, etc., you can enjoy the joy of opening your new home with the sick house syndrome, such as the stinging smell and stinging eyes that may appear after the interior work. It is only a moment. Volatile organic compounds from building materials, adhesives, wallpaper, and paints used in new buildings or new furniture cause residents' health and discomfort in indoor life. These volatile organic compounds include benzene, toluene, acetone, and styrene, as well as the representative formaldehyde, and these substances are slowly released over a long period of time, causing acute or chronic diseases to residents. As a method for removing organic volatile substances, physical methods using adsorption, chemical methods for converting volatile substances to other substances, or a mixture of the two are mainly used. In this paper, a sustained release chlorine dioxide gel pack obtained by a method for controlling the reaction rate of a reactant and the release of a product is mixed with a zeolite adsorbent having an optimized hole diameter to adsorb and decompose and remove formaldehyde suspended in the air. I would suggest an effective method.

A Study on a Process for Conversion of Carbon Dioxide through Saline Water Electrolysis (염수 전기분해와 연계한 이산화탄소의 전환 공정 연구)

  • Lee, Dong Woog;Lee, Ji Hyun;Lee, Junghyun;Kwak, No-Sang;Lee, Sujin;Shim, Jae-Goo
    • Korean Chemical Engineering Research
    • /
    • v.55 no.1
    • /
    • pp.86-92
    • /
    • 2017
  • A process, which converts carbon dioxide contained in the flue gas of coal-fired power plants to sodium bicarbonate, was studied experimentally and numerically. In this process, the carbon dioxide reacts with sodium hydroxide which is produced through saline water electrolysis. A bench scale reactor system was prepared for experiments of this process and numerical process modeling was performed for the bench scale reactor system. Comparing the process modeling results with the experimental data, responsibility of the process modeling was confirmed. Using this model, commercial scale process was simulated. Mass and energy balance of this process were calculated. Temperature profile in the reactor and carbon dioxide removal rate were obtained.

Nutrient Digestibility and Greenhouse Gas Emission in Castrated Goats (Capra hircus) Fed Various Roughage Sources (조사료원 종류가 거세 염소(Capra hircus)의 영양소 소화율 및 온실가스 발생량에 미치는 영향)

  • Na, Youngjun;Hwang, Seokjin;Choi, Yongjun;Park, Geetae;Lee, Sangrak
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.38 no.1
    • /
    • pp.39-43
    • /
    • 2018
  • The objective of this study was to determine the effect of various roughage sources on nutrient digestibility and enteric methane ($CH_4$), and carbon dioxide ($CO_2$) production in goats. Four castrated black goats ($48.5{\pm}0.6kg$) were individually housed in environmentally controlled respiration-metabolism chambers. The experiment design was a $4{\times}4$ balanced Latin square design with 4 roughage types and 4 periods. Alfalfa, tall fescue, rice straw, and corn silage was used as representative of legume, grass, straw, and silage, respectively. Dry matter digestibility was higher (p < 0.001) in corn silage than in alfalfa hay. Dry matter digestibility of alfalfa hay was higher than those of tall fescue or rice straw (p < 0.001). Neutral detergent fiber digestibility of tall fescue was lower (p < 0.001) than those of alfalfa, rice straw, or corn silage. Daily enteric $CH_4$ production and the daily enteric $CH_4$ production per kilogram of $BW^{0.75}$, dry matter intake (DMI), organic matter intake (OMI), digested DMI, and digested OMI of rice straw did not differ from those of tall fescue but were higher (p < 0.001) than those of alfalfa or corn silage. Roughage type had no effect on enteric $CO_2$ emission in goats. Straw appeared to generate more enteric $CH_4$ production than legume or silage, but similar to grass.