• Title/Summary/Keyword: 열 유속 특성

Search Result 282, Processing Time 0.026 seconds

A Combustion Characteristic Analysis of Sandwich Panel Core Using Radiation Heat Flux (복사열을 이용한 샌드위치 패널 심재의 연소특성 분석)

  • Park, Hyung-Ju
    • Fire Science and Engineering
    • /
    • v.21 no.4
    • /
    • pp.25-31
    • /
    • 2007
  • The combustion characteristics and combustion heat of sandwich panel cores were analysed using variable external irradiation level. The characteristics such as ignition time, critical heat flux, ignition temperature and surface temperature profile were measured. Fuel samples were exposed to incident heat fluxes from 15 to $50\;kW/m^2$. For the measurement of various combustion characteristics, the size of specimen was $100\;mm\;{\times}\;100\;mm\;{\times}\;50\;mm$ and the samples were 3 different kinds. As results, Type B showed the best characteristics in measurement of combustion heat and ignition temperature and Type C showd the best characteristics in critical heat flux and surface temperature profile than that of the other two. In conclusion, we knew that Type C had the best performance in fire safety from all data of this study.

Parametric Study on Heat Flux Characteristics of a Sub-scale Calorimeter (막냉각량 및 작동점 변화가 액체로켓 칼로리미터의 열유속에 미치는 영향)

  • Kim Jong-Gyu;Lee Kwang-Jin;Seo Seong-Hyeon;Han Yeoung-Min;Choi Hwan-Seok;Cho Won-Kook
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.346-350
    • /
    • 2005
  • Effects of the changes of a film cooling mass flow rate and operating conditions on the heat flux characteristics of the subscale calorimeter were studied. A film cooling ring with twelve orifices is inserted between the injector head and the calorimeter. The calorimeter is composed of nineteen cooling channels. When a mass flow rate of film cooling is 10.5 % of a main fuel mass flow rate, maximum heat flux at the nozzle throat is decreased by 30% compared to that without film cooling. In the OD3(of-design point) test result, maximum heat flux at the nozzle throat is increased by 31% compared to that of the DP(design point) test when a film cooling flow rate is zero.

  • PDF

Measurement of Aerodynamic Heating over a Protuberance in Hypersonic Flow of Mach 7 (Mach 7 극초음속 유동 내의 돌출물 공력가열 계측)

  • Lee, Hyoung-Jin;Lee, Bok-Jik;Jeung, In-Seuck;Kim, Seong-Lyong;Kim, In-Sun
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.37 no.6
    • /
    • pp.562-570
    • /
    • 2009
  • An Experimental study was conducted on the flow characteristics and interference heating caused by a two-dimensional object protruding from a flat plate using a blow-down type of hypersonic wind tunnel. Inflow condition was a free-stream Mach number of 7.0 and a unit Reynolds number of $2.0{\times}10^6/m$. Experimental conditions were varied with three heights of protuberance for two flat plate models which have different lengths. Experimental data were obtained from Schlieren visualization images and heat flux measurements. Also, this paper suggests hypersonic experimental techniques such as boundary-layer detection method in detail. A Large separation region was observed in front of the protuberance and that region was very sensitive to the height of protuberance and the length of the flat plate. For only the highest protuberance, a severe jump of heat flux was observed at the top station among the measuring points. Measured heat flux is large when the height of protuberance is large and the length of flat plate is long.

An Experimental Study on Heat Transfer Characteristics of Synthetic Gas($H_2/CO$)Air Premixed Flames in an Impinging Jet Burner - Part 1 : Stretched Lift-off Flames (충돌제트 버너에서 합성가스($H_2/CO$) 공기 예혼합 화염의 열전달 특성에 관한 실험적 연구 - Part 1 : 스트레치된 부상 화염)

  • Kang, Ki-Joong;Jo, Joon-Ik;Lee, Kee-Man
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.04a
    • /
    • pp.453-456
    • /
    • 2011
  • An experimental investigation of the heat transfer characteristics of stretched premixed flames using Synthetic gas has been performed. Hydrogen and carbon mon-oxide which could be extracted from coal gasification process are the main fuel of synthetic-gas. Heat flux at the stagnation point was increased as global strainrate was increased, then the heat flux was decreased when a global strainrate reached a sudden point. Heat flux at the stagnation point is also affected by nozzle to impingement distance. Heat flux was increased as nozzle to impingement place distance was increased. This study is a foundation study of practical use of secondary gases from coals.

  • PDF

열전특성 측정 장비 내 수냉식 열배출기의 층수에 따른 열전달거동의 변화

  • Kim, Yeong-Seok;Ha, Su-Hyeon;Gang, Sang-U;Kim, Tae-Seong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2015.08a
    • /
    • pp.92.1-92.1
    • /
    • 2015
  • 열전소재의 열전성능을 평가하기 위해서는 샘플 내 상하부 온도구배가 필요하다. 하지만 진공챔버 내에서는 대류효과가 제한되어, 1 mm 이하 두께의 얇은 샘플은 상하부 방향으로 온도 구배를 조성하기 어렵다. 온도 구배를 조성하기 위해서는 샘플의 두께 방향을 관통하는 열유속이 필요하며, 진공 분위기에서 열유속을 조성하기 위해서는 히터뿐만 아니라 별도의 열배출기가 요구된다. 본 연구에서는 열전특성 측정 장비 내 수냉식 열배출기의 설계를 위해, 열배출기의 층수를 달리하며 열전달거동을 수치해석적인 방법으로 연구하였다. 열배출기의 층수에 따른 영향을 평가하기 위해서 동일한 채널길이를 유지시키면서 층수를 달리하는 기하학적인 구조들을 설계하였다. 수치해석을 용이하게 진행하기 위해, 열배출기의 형태는 단순한 bar 형태를 가진 1-5층의 다층 구조 로 설계하였다. 열배출기들 각각의 열전달 효율을 평가하기 위해, 수냉식 열배출기의 열배출량에 가장 큰 영향을 미치는 질량유량을 0.1-1 g/s로 변화 시키면서 열전달 거동을 확인하였다. 또한 냉각수의 기화 현상을 방지하기 위해 발열체의 온도를 290-370 K로 바꿔 가며 열전달 거동을 확인하였다. 수치 해석결과, 5층의 열배출기가 최대 120 W/cm2 로 높은 단위면적당 열배출량을 가지는 것을 확인하였으나, 열배출기 전체의 열배출량을 기준으로하는 열배출효율은 0.6 정도로 낮은 효율을 가짐을 확인하였다. 반면에 3층의 열배출기의 경우, 열배출 효율이 0.8에 달하며, 2층의 열배출기 보다 열배출 효율이 좋다는 것을 확인할 수 있었다.

  • PDF

Heat Flow of Round Jet Impinging Aluminum Foam Mounted on the Heated Plate with Constant Heat Flux (균일한 열유속을 갖는 가열된 평판에 부착된 발포알루미늄에 대한 원형 충돌제트의 열유동 특성)

  • Han, Young-Hee;Lee, Kye-Bock;Lee, Chung-Gu
    • Journal of Energy Engineering
    • /
    • v.18 no.2
    • /
    • pp.108-113
    • /
    • 2009
  • An experimental study of jet impingement on aluminum foam mounted on the surface with constant heat flux is conducted with the presentation of the heat transfer rate measured when jet impinges normally to a flat plate. Effects of pore density, foam thickness and Reynolds number on the heat transfer are analyzed. Experimental results show that the significant enhancement in Nu is obtained when the aluminum foam is mounted on the heated plate and that the increase in the heat transfer due to the porous material insertion is dominated by both the increase in the heat transfer area and the decrease in the momentum flux resulted from the pressure drop.

The Combustion Characteristice of the Self Preheating Type Catalyic Heat Exchanger (자체 예열식 촉매 열 교환식 연소특성)

  • 유상필;송광섭;서용석;조성준;류인수
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 2001.05a
    • /
    • pp.45-52
    • /
    • 2001
  • The study on the heat exchanger with catalytic combustion was performed as the development of the catalytic combustion applications. This study tried to achieve the both goals-the mixture preheating and the heat transfer to working fluid simultaneously by using the steady state catalytic combustion. The combustion characteristics were investigated with the quantitative, qualitative experimental variants of the mixture. In addition, the temperature distribution of catalytic layer was investigated to investigate the correlation between the combustion characteristics and the heat balance of the catalytic layer. As a result, the steady state reaction within the appropriate range of temperature is the critical factor in catalytic applications. To get this, the sensible control of both the mixture flow and the heat balance of catalytic layer were required.

  • PDF

Boiling Heat Transfer Characteristics of Deionized Water in Microchannel (마이크로 채널에서 물의 비등 열전달 특성)

  • Lim, Tae-Woo;You, Sam-Sang;Choi, Hyeung-Sik;Kim, Dong-Hyuk
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.6
    • /
    • pp.750-756
    • /
    • 2011
  • An experimental study was carried out to measure the heat transfer coefficient in flow boiling to deionized water in a microchannel having a hydraulic diameter of $500{\mu}m$. Tests were performed in the ranges of heat fluxes from 100 to 400 kW/$m^2$, vapor qualities from 0 to 0.2 and mass fluxes of 200, 400 and 600 kg/$m^2s$. From the experimental results, it is found that the measured heat transfer coefficients is independent of mass flux and quality, and is somewhat dependent of heat flux. Measured data of heat transfer are compared to a few available correlations proposed for macroscale. The previous correlations for macroscale overpredicted the flow boiling heat transfer coefficient for the test conditions considered in this work.

부유성 HNS의 근접영역의 확산 특성에 대한 수치해석

  • Go, Min-Gyu;Jeong, Chan-Ho;Lee, Mun-Jin;Jeong, Jeong-Yeol;Lee, Seong-Hyeok
    • Proceedings of KOSOMES biannual meeting
    • /
    • 2017.11a
    • /
    • pp.162-163
    • /
    • 2017
  • 해양 HNS(Hazardous and Noxious Substances)의 유출 사고 시, 막대한 인명 피해와 환경 훼손을 피하기 위해 유출 사고 조기 예측과 정확한 확산 경로를 예측하는 것이 필수적이다. 본 연구의 최종목적은 전산유체역학을 이용하여 HNS사고가 발생하였을 때 위험구역을 적절히 예측할 수 있는 수치해석기법을 개발하고, 다양한 해양사고조건과 환경영향을 고려하여 근접역에서의 2차원 확산 특성을 고찰하고 확산 현상을 예측하기 위한 모델을 개발하는 것이다. 본 연구에서는 상용코드인 ANSYS FLUENT(V. 17.2)을 사용하여 근접역에서의 2차원 확산특성을 모사하고 분석하였다. 특히, 누출된 HNS의 위치별 농도를 예측하기 위해 종수송방정식(Species Transport Equation)을 이용하였으며 RANS(Reynolds-Averaged Navier-Stokes) 방정식과 표준 $k-{\varepsilon}$ 모델을 이용하여 난류유동을 모사하였다. 해석된 결과는 문헌에서 얻어진 실험데이터와 상호비교하였으며 해수의 유속, HNS의 밀도에 따른 유층 두께, 해수면 HNS 평균 농도 그리고 HNS 전파 속도를 분석하였다. 유층 두께는 해류 유속에 따라 변화하며 변화 경향에 따라 두 구간으로 나눌 수 있다. 해류 전파 속도는 대체로 해류 유속과 선형적 비례관계를 갖는 것으로 나타났다. 해수면 평균 HNS 농도는 해류 유속에 선형적으로 비례하여 감소하며, HNS 밀도가 큰 경우 해수면 평균 HNS 체적 농도는 더 빠르게 감소하게 된다. 이러한 결과는 HNS 확산 특성을 분석하고 관련된 예측모델을 개발하는 데에 기여할 수 있다.

  • PDF

Film Boiling Heat Transfer Characteristics in Liquid-Liquid System (액체,액체계의 막비등열전달 특성)

  • 김병주
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.1
    • /
    • pp.87-94
    • /
    • 1992
  • Film boiling heat transfer characteristics in liquid-liquid systems are studied experimentally. Liquid gallium as a heating liquid, n-pentane, freon-113, and ethanol are used as boiling liquids. In gallium-n-pentane and gallium-freon-113 systems the minimum film boiling point occurred at higher temperature than those observed in copper-boiling liquid systems. However MFB point occurred almost at the same temperature for the case of ethanol. This difference are due to the effects of contact angle and interfacial agitations in gallium-boiling liquid systems. Film boiling heat transfer rate, for the gallium-boiling liquid systems considered in this work, found to be approximately 10% higher than those in copper-boiling liquid systems, whose main cause is believed to be gallium-boiling liquid interfacial agitations affected by the density ratio between gallium and boiling liquid.