• Title/Summary/Keyword: 열 에너지

Search Result 4,346, Processing Time 0.032 seconds

아세톤을 사용한 목질계 바이오매스의 가용매 분해에 대한 연구

  • Lee, Hong-Seon;Yun, Seong-Uk;Lee, Byeong-Hak
    • 한국생물공학회:학술대회논문집
    • /
    • 2000.11a
    • /
    • pp.216-219
    • /
    • 2000
  • Pyrolysis products of woody biomass were consistedofvarious linear hydrocarbon, aromatics or condensed cyclic compounds. In order to obtain biomass pyrolysis products, more equipments and time were needed. But solvolysis of woody biomass with acetone easily obtained decomposition products and enhanced conversion rate(18.72%, max.) from woody biomass than pyrolysis of woody biomass. Beacause solvolysis with acetone improved conversion rate (26.64%, max.) of lignin. the whole conversion rate was improved. But above $300^{\circ}C$, lignin showed lower conversion rate, so the whole conversion rate decreased. Solvolysis products of woody biomass with acetone were same as pyrolysis products. Above $400^{\circ}C$, methoxy phenols were completely disappeared.

  • PDF

The method of in-situ ASTR method diagnosing wall U-value in existing deteriorated houses - Analysis of influence of internal surface total heat transfer rate -

  • Kim, Seo-Hoon;Kim, Jong-Hun;Jeong, Hakgeun;Song, Kyoo-dong
    • KIEAE Journal
    • /
    • v.17 no.4
    • /
    • pp.41-48
    • /
    • 2017
  • Purpose : Currently, 25% of the domestic energy consumption structure is used as building energy, and more than 18% of this energy is consumed in the residential. Accordingly, various efforts and policies that can save energy of the building is being performed. The various researchers are conducting research to diagnose the thermal performance of existing buildings. This study is to apply in the field of precision thermal insulation performance diagnostic method for thermal performance analysis of existing detached house in Seoul, Gangreung, Gyeongju, Pohang. And this paper is analyzed quantitatively measure the existing detached house energy performance. Method: Research methodology analyzed the thermal performance over the Heat Flow Meter method by applying the measurement process and method by applying the criteria of ISO 9869-1 & ASTR method. In this study, the surface heat transfer coefficient was calibrated by applying indoor surface heat transfer resistance with reference to ISO 6946 standard. The measurement error rate between the HFM diagnosis method and the ASTR diagnosis method was reduced and the measurement reliability was obtained through measurement method error verification. Result : As a result of the study, the thermal performance vulnerable parts of the building were quantitatively analyzed, and presented for methods which can be improved capable of efficient energy use buildings.

Thermal oxidation and oxidation induced stacking faults of tilted angled (100) silicon substrate (저탈각 (100) Si 기판의 열산화 및 적층 결함)

  • 김준우;최두진
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.6 no.2
    • /
    • pp.185-193
    • /
    • 1996
  • $2.5^{\circ}\;and\;5^{\circ}$ tilted (100) Si wafer were oxidized in dry oxygen, and the differences in thermal oxidation behavior and oxidation induced stacking faults (OSF) between specimens were investigated. Ellipsometer measurements of the oxide thickness produced by oxidation in dry oxygen from 900 to $1200^{\circ}C$ showed that the oxidation rates of the tilted (100) Si were more rapid than those of the (100) Si and the differences between them decreased as the oxidation temperature increased. The activation energies based on the parabolic rate constant, B for (100) Si, $2.5^{\circ}$ off (100) Si and $5^{\circ}$ off (100) Si were 27.3, 25.9, 27.6 kcal/mol and those on the linear rate constant, B/A were 58.6, 56.6, 57.6 kcal/mol, respectively. Also, considerable decrease in the density of oxidation induced stacking faults for the $5^{\circ}$ off (100) Si was observed through optical microscopy after preferentially etching off the oxide layer, and the angle of stacking faults were changed with tilted angles.

  • PDF

The verification about possibility of introducing Window to Floor Ratio as design index for building energy performance

  • Choi, Won-Ki;Lee, Yong-Jun;Lee, Hyun-Soo;Eom, Jae-Yong;Lee, Chung-Kook
    • KIEAE Journal
    • /
    • v.17 no.1
    • /
    • pp.23-28
    • /
    • 2017
  • Purpose: Many design index that are using in planning phase have been developed. The most popular things among them are Window to Wall Ratio and Surface to Volume Ratio. However there are some limits. Window to Wall Ratio cannot consider building size and Surface to Volume Ratio cannot do Window to Wall Ratio. Accordingly, in this paper, the Window to Floor Ratio was proposed that it can be considered both building size and Window to Wall Ratio. And analyzed correlation of energy demand. Method: For the test, 16 modules with the size of $6m{\times}6m{\times}4m$ were used to make 35 models with the same volume. The simulation was conducted to 945 cases using the window-to-wall ratio of 30, 50 and 70 % in three areas such as Seoul, Gwangju and Jeju and three kinds of windows. And IES_VE was used. Result: The findings above show that the Window to Floor Ratio that can be considered both building size and Window area have to become as design index. It was found out that design criteria with SHGC is necessary, not with the thermal performance (U-value). It is needed to additional analysis about residential building and the effect of 24-hours heating and cooling condition. It plans to carry out research to establish design indicators for climatic conditions in the country and building applications.

The Design and Implementation of AMI System Using Binary CDMA (Binary CDMA 기반의 AMI 시스템 설계 및 구현)

  • Joe, In-Whee;Jeong, Jong-Yuel
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37 no.8C
    • /
    • pp.663-669
    • /
    • 2012
  • To solve the energy problem and finding new growth engines, interest for the smart grid is increasing and related technologies are making great efforts to secure in the world. AMI (Advanced Metering Infrastructure) Among them is the first to be constructed and getting attention as a key component of smart grid. A fusion of various technologies in technology development and demonstration is underway on Jeju Island Smart Grid Demonstration Complex in Korea, and focusing on broadband power line communication technology infrastructure is actively underway in Korea Electric Power Corporation. AMI system using power line communication technology without building a separate communication lines are available for power supply lines, but communication is impossible in occurs because admission to the power company or the ideal infrastructure for communication is not considered. In this paper, we analyze the requirements to build AMI system using Binary CDMA and powerline communications technology, and design the basic communication protocol based on Binary CDMA, implement network management and relay feature. By doing so, ways to apply Ad-hoc Binary CDMA indigenous technology to the AMI system were derived, and could build a system to make use of Wired (PLC) and wireless (Binary CDMA) simultaneously.

The Properties of Concrete with Lightweight Aggregate Impregnated by Phase Change Material (상변화물질 함침 경량골재를 사용한 콘크리트의 특성)

  • Kim, Se-Hwan;Jeon, Hyun-Kyu;Hwang, In-Dong;Seo, Chee-Ho;Kim, Sang-Heon
    • Journal of the Korea Concrete Institute
    • /
    • v.25 no.3
    • /
    • pp.331-338
    • /
    • 2013
  • Under the paradigm of sustainable green growth at the national level, various researches and applications for energy saving in the construction field has been attempted. As a part of energy saving efforts, lightweight concrete was investigated for thermal insulation concrete with phase change material (PCM) which has high heat storage capacity. As a part of energy saving efforts, thermal insulation concrete was investigated and evaluated with lightweight aggregate impregnated by PCM which has high heat storage capacity. As a result, it is found that concrete with lightweight aggregate impregnated by PCM is effective to prevent its quality deterioration by reducing water absorption rate of lightweight aggregate. In addition, it has shown that concretes using lightweight aggregate and impregnated lightweight aggregate improve heat insulation property 33% and 40~43% compared with using normal aggregate, respectively. It is that the lightweight aggregate concrete with impregnated lightweight aggregate has 12~14% lower thermal conductivity than unimpregnated.

A 3 V 12b 100 MS/s CMOS DAC for High-Speed Communication System Applications (고속통신 시스템 응용을 위한 3 V 12b 100 MS/s CMOS D/A 변환기)

  • 배현희;이명진;신은석;이승훈;김영록
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.40 no.9
    • /
    • pp.685-691
    • /
    • 2003
  • This work describes a 3 V 12b 100 MS/s CMOS digital-to-analog converter (DAC) for high-speed communication system applications. The proposed DAC is composed of a unit current-cell matrix for 8 MSBs and a binary-weighted array for 4 LSBs, considering linearity, power consumption, chip area, and glitch energy. The low-glitch switch driving circuit is employed to improve the linearity and the dynamic performance. Current sources of the DAC are laid out separately from the current-cell switch matrix core. The prototype DAC is implemented in a 0.35 urn n-well single-poly quad-metal CMOS technology. The measured DNL and INL of the prototype DAC are within $\pm$0.75 LSB and $\pm$1.73 LSB, respectively, and the spurious-free dynamic range (SFDR) is 64 dB at 100 MS/s with a 10 MHz input sinewave. The DAC dissipates 91 mW at 3 V and occupies the active die area of 2.2 mm ${\times}$ 2.0 mm.

Numerical analysis of solar pond with insulation layer (단열층을 가지는 솔라 폰드의 수치해석)

  • Yu, Jik-Su;Mun, Soo-Beom
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.4
    • /
    • pp.264-269
    • /
    • 2016
  • This paper reports a fundamental study of temperature characteristics of a solar pond with an insulation layer. Further, these characteristics were compared with those of a solar pond without the insulation layer. The governing equation was discretized via finite difference method. The governing equations are two-dimensional unsteady-state second-order partial differential equations. The conclusions of the study are as follows: 1) If the depth of the solar pond was increased, the desired effect of increase in temperature was not produced because the amount of solar insolation received by the bottom of the solar pond decreased. 2) As the temperature of the soil during winter is higher than the temperature of the water in a solar pond, heat was transferred from the soil to the solar pond. 3) For the case of the solar pond with insulation layer, it was estimated that the dependence rate of solar energy was 83.3% and that of the boiler was 16.7%.

The study on substructure design and analysis for 5MW offshore wind turbine (5MW급 해상풍력 하부구조물 설계 및 해석에 관한 연구)

  • Sun, Min-Young;Lee, Sung-Bum;Lee, Ki-Yeol;Moon, Byung-Young
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.9
    • /
    • pp.1075-1080
    • /
    • 2014
  • This study aims at dedicating to relevant technology fields by suggesting design methods of structures and estimating their safety in relation to substructure for offshore wind power requiring high safety to various environment conditions. Especially, with respect to 5MW Offshore Wind Power System, this study will provide information about major wind directions and duration in combination with the developing wave climate at the test field. Therefore, connections between wind fields and approaching wave trains will be estimated and their intensity, direction and time shift will be pointed out. Furthermore, the local pressure distribution of breaking waves will be investigated by physical and numerical modeling. The currently applied structural and fatigue assessment of support structures for offshore wind energy converters is based on common design rules. Normally, constructions in structural engineering are treated as limited, single structures. This means that varying aspects of manufacturing are considered by high safety factors.

Effect of the Curing Behavior on Electrical and Mechanical Properties of Multifunctional Structural Electrolyte (경화 거동에 따른 다기능 구조 전해질의 전기적 기계적 특성 연구)

  • Kwon, Suk Jin;Choi, U Hyeok;Jung, Byung Mun;Kim, Yang Do;Lee, Sang Bok
    • Composites Research
    • /
    • v.29 no.6
    • /
    • pp.395-400
    • /
    • 2016
  • Recently, many research groups have studied on the epoxy-based multifunctional electrolyte to develop the structural composite bearing high mechanical properties without sacrificing the ionic conductivity at the same time. The studies on the optimal content and material selection for structural electrolyte have been published, while its curing behavior has not much analyzed yet. In this study, epoxy-based structural electrolyte containing solid electrolyte was prepared by varying the curing temperature and time. In addition, the ionic conductivities and mechanical properties of specimens were measured. We also find out the optimal hardening condition where the epoxy domain enables to be hardened within the range of temperature at which the thermal decomposition of electrolyte does not occur. Finally, we propose the multifunctional structural electrolyte showing achievable electrical and mechanical properties (282 MPa and $9{\times}10^{-6}S/cm@25^{\circ}C$).