• Title/Summary/Keyword: 열 복사

Search Result 727, Processing Time 0.034 seconds

Analysis of natural convection-radiation heat transfer using the finite volume method in enclosure (유한체적법을 이용한 밀폐공간내의 자연대류-복사열전달 해석)

  • 박광수;박경우;박희용
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.1
    • /
    • pp.95-107
    • /
    • 1998
  • Natural convection and radiation heat transfer in a square enclosure containing absorbing, emitting, and isotopically scattering(participating) media is studied numerically using the finite volume method. Various numerical methods are employed to analyze the radiative heat transfer. However, it is very difficult to choose the proper method. In present study, a finite volume method(FVM) and a discrete ordinates method(DOM) are compared in rectangular enclosure. The SIMPLER algorithm is used to solve the momentum and energy equations. Thermal and flow characteristics are investigated according to the variation of radiation parameters such as optical thickness and scattering albedo. The result shows that the accuracy and the computing time of FVM are better than those of DOM in regular geometry.

  • PDF

A Study on the Radiation and Convection Component Separated from Surface Combined Heat Transfer Coefficient on Dynamic Heat Load Simulation (표면 열전달율의 복사.대류성분 분리와 비정상 열부하 계산에 관한 연구)

  • Kim, Young-Tag;Choi, Chang-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.25 no.3
    • /
    • pp.1-9
    • /
    • 2005
  • The purpose of this paper was to analyze the influence of radiation and convection component separated from surface heat combined transfer coefficient on dynamic Heat load simulation. In general, it was not considered the mutual radiation of walls that heat load simulation calculated by surface combined heat transfer coefficient. In order to solve this problem, we had developed new simulation program to calculate radiation heat transfer and convection heat transfer respectively, and verified the influence of radiation component with this new program, in indoor heat transfer process.

A Numerical Study on Radiation-Induced Oscillatory Instability in CH$_4$/Air Diffusion Flames (메탄/공기 확산화염에서 복사 열손실로 인한 맥동 불안정에 관한 수치해석)

  • Son, Chae-Hun;Jeong, Seok-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.1
    • /
    • pp.29-35
    • /
    • 2001
  • Radiation-induced oscillatory instability in CH$_4$/Air diffusion flames is numerically investigated by adopting detailed chemistry. Counterflow diffusion flame is employed as a model flamelet and optically thin gas-phase radiation is assumed. Attention is focused on the extinction regime induced by radiative heat loss, which occurs at low strain rate. Once a steady flame structure is obtained for a prescribed value of initial strain rate, transient solution of the flame is calculated after a finite amount of strain-rate perturbation is imposed on the steady flame. Depending on the initial strain rate and the amount of perturbed strain rate, transient evolution of the flame exhibits various types of flame-evolution behaviors. Basically, the dynamic behaviors can be classified into two types, namely oscillatory decaying solution and diverging solution leading to extinction.

Analysis of the Radiative Heat Transfer in a Cylindrical Enclosure with Obstacles Using the Discrete Ordinate and Finite Volume Method (구분종좌표법 및 유한체적법을 이용한 장애물이 있는 원통형 밀폐공간에서의 복사열전달 해석)

  • Kim, Seong-Woo;Kim, Il-Kyoung;Kim, Woo-Seung
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.347-352
    • /
    • 2000
  • In the present study, DOM and FVM have been used to analyze the radiative heat transfer in an axisymmetric cylindrical enclosure with obstacles. Heat flux distributions on the wall of enclosure form DOM and FVM are compared to those from simplified zone analysis for a nonparticipating medium. The comparison of DOM and FVM is also presented. Results show that there is a good agreement between FVM and simplified zone analysis. In addition, the effect of the thickness of the obstacle on the results is considered. Heat flux distribution on the surface of the obstacle is also presented.

  • PDF

Numerical and Experimental Investigation of Thermal Behavior of a Radiation Heater for Flip-Chip Bonders (플립칩 본더용 복사형 히터의 열특성 해석 및 시험)

  • Lee, Sang-Hyun;Kwak, Ho-Sang;Han, Chang-Soo;Ryu, Do-Hyun
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.1645-1650
    • /
    • 2003
  • A numerical and experimental study is made of thermal behavior of a hot chuck which is specially designed for flip-chip bonders. The hot chuck consists of radiant heat sources and a heated plate of very high conductivity, which is for achievement of high-speed heat-up. A simplified numerical model is developed to simulate unsteady thermal behavior of the heated plate. Parallel experimental work is also conducted for a prototype of the hot chuck. Based on the experimental data, the numerical model is tuned to improve the reliability and accuracy. Design analysis using the numerical model is conducted. The results of numerical computations illustrate that the radiant heater system adopted in this study satisfies the key design requirements for a high-performance hot chuck.

  • PDF

A Study on the Radiation Heat Transfer Characteristics of Liquid Droplet Radiator (액적방열기의 복사열전달 특성에 관한 연구)

  • 김금무;김용모;김경근
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.18 no.1
    • /
    • pp.32-40
    • /
    • 1994
  • The radiative heat transfer analysis in particle layer has an inherent difficulty in treating the governing integro-differential equations, which are derived from the remote effects. Most of the existing analyses are limited to the one dimensional system, taking into account only absorption or isotropic scatting of solid particles. Fortunately, a new Monte Carlo Simulation method is recently developed to analyse multidimensional radiative heat transfer in particles with anisotropically scatting. By this method, the present study analyses the radiative heat transfer in dispersed particles through the numerous droplets in the liquid droplet radiator to develop a technique of liquid droplet radiator. Consequently, knows that the radiative heat flux in particle layer is influenced by exitinction coefficient, optical thickness and surface area of particles in the system.

  • PDF

Development of the Sunshade hat with a large brim (Part II) - Human trial test at outdoors - (양산형 일광차단모의 개발(제2보) -실외 인체착용시 복사열 및 자외선의 차단효과-)

  • 최정화;김경수
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.28 no.3_4
    • /
    • pp.414-421
    • /
    • 2004
  • To reduce farmer's stress from solar radiation and ultraviolet radiation(UV), the sunshade hat with a large brim and special structure for ventilation was developed and tested with manikin heads outdoors at previous study(Kim and Choi, 2002). To evaluate the protection efficiency of the sunshade hat, human trial test was performed at outdoors. The results were as follows; Skin temperatures(7 sites), heart rate, temperature inside the hats, temperature and relative humidity inside clothing on the back in wearing developed sunshade hat were significantly lower than those in wearing the controlled hat. In subjective sensation, subjects answered to feel significantly hotter, more humid and more uncomfortable in wearing the controlled hat. But relative humidity inside the hats was significantly higher in wearing developed hat. In rectal temperature, there were no significant differences between two hats.

A Study on the Hazard of Radiant Heat of the Fire Shutters in Fire (방화셔터 복사열의 위험성 예측에 관한 연구)

  • Jeon, Jun-Pyo;Min, Byung-Yeol;Jeon, Soo-Min;Rie, Dong-Ho
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.160-164
    • /
    • 2011
  • 국내 건축법에서는 화재의 확산을 방지하기 위해 방화구획을 설치하여 인명피해와 재산피해를 최소화 하고 있다. 따라서 방화구획 개구부의 방화문, 방화셔터 등 각종 배관 관통부 시스템의 화재저항 성능이 중요하다. 이에 본 연구에서는 방화구획 중 넓은 면적에 사용되는 방화셔터를 각 종류별 내화성능실험을 통하여 방화셔터의 방화성능 확인과 더불어 실험시 방화셔터에서 발생하는 복사열의 측정을 통하여 화재가 확대될 수 있는 위험성을 예측하였다.

  • PDF

A Theoretical Study of Photothermal Pulsed Radiometry Method for the Thermal Diffusivity Measurement (재료의 열확산계수 결정을 위한 광열복사법의 이론적 연구)

  • Yook, Hyung-Kyu;Yoo, Jai-Suk;Kim, Hyun-Jung;Lee, Kwang-Jai
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.1 s.232
    • /
    • pp.27-34
    • /
    • 2005
  • We analyze in detail axially symmetric theoretical study for the photothermal pulsed radiometry of a cylindrical model. The theoretical solutions describe the transient infrared radiation from the sample heated by short-duration pulsed heating. In the conventional transmission radiometry technique, the excitation source and the detector are on opposite sides of the sample, otherwise in the new single ended radiometry technique, the excitation source and the detector are on same sides of the sample. The analytical solution described for photothermal radiometry in this study would not need to cut or polish samples to measure the thermal diffusivity. Therefore the radial area and axial thickness of samples are not limited. The effects of excitation pulse duration and the area of heat source are discussed.

A Study on the Thermal Environmental Analysis and the Application of Radiant Floor Cooling in Apartment Building (공중주택의 열환경분석과 바닥복사냉방의 적용에 관한 연구)

  • 김용이;김광우
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.6
    • /
    • pp.541-548
    • /
    • 2001
  • The objective of this study is to analyze the possibilities and considerations for the application of the radiant floor cooling system by analyzing the problems of a conventional cooling system through field tests and thermal performance simulations of the radiant floor cooling in an apartment building. The results are as follows. (1) Problems of he conventional cooling system with PAC()packaged air conditioner)'s include draft, local discomfort, and excessive electrical peak demand. (2) According to the measurement during the cooling and intermediate seasons, the floor surface temperatures which are experienced at the time of cooling with PAC\`s and during intermediate season are similar to the temperatures for radiant floor cooling. (3) The radiant floor cooling system is applicable to apartment buildings during the cooling season, especially on hot and clear days.

  • PDF