• Title/Summary/Keyword: 열 기포

Search Result 123, Processing Time 0.021 seconds

Prediction of time-series underwater noise data using long short term memory model (Long short term memory 모델을 이용한 시계열 수중 소음 데이터 예측)

  • Hyesun Lee;Wooyoung Hong;Kookhyun Kim;Keunhwa Lee
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.4
    • /
    • pp.313-319
    • /
    • 2023
  • In this paper, a time series machine learning model, Long Short Term Memory (LSTM), is applied into the bubble flow noise data and the underwater projectile launch noise data to predict missing values of time-series underwater noise data. The former is mixed with bubble noise, flow noise, and fluid-induced interaction noise measured in a pipe and can be classified into three types. The latter is the noise generated when an underwater projectile is ejected from a launch tube and has a characteristic of instantaenous noise. For such types of noise, a data-driven model can be more useful than an analytical model. We constructed an LSTM model with given data and evaluated the model's performance based on the number of hidden units, the number of input sequences, and the decimation factor of signal. It is shown that the optimal LSTM model works well for new data of the same type.

경사유로내에서 유동비등에 관한 실험적 연구

  • 이태호;김문오;박군철
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1997.10a
    • /
    • pp.487-494
    • /
    • 1997
  • 비등이 발생하는 경사유로에서 이상유동 구조 파악을 위해 국부적 이상유동 변수의 측정이 이루어졌다. 국부 기포율, 국부 기포빈도, 국부기포속도 그리고 국부 기포크기와 같은 기상 관련 이상유동변수는 이중 전기전도도 탐침으로, 액상속도 분포는 Pilot tuba로 측정하였다. 유로의 경사도가 이상유동 구조에 미치는 영향을 파악하기 위해 실험은 수직, 수직으로부터 30도 경사도 및 60도 경사도에서 유량과 열유속을 변화시켜가며 수행하였으며 유동변수의 측정은 경사진 경우에 측면 방향으로의 대칭성을 고려하여 유로 반 단면내 총 91개 지점에서, 수직인 경우에는 13개 지점에서 이루어졌다. 유동조건은 1.4m/s 이하의 평균 액상 겉보기 속도에 제한되었고 유로내 압력은 대기압이며 유동양식은 미포화 비등에 국한되었다. 측정된 이상유동 변수의 분포를 이용하여 경사유로에 적용할 수 있는 distribution parameter와 drift velocity 같은 dirft flux parameter에 대한 상관식이 개발되었다.

  • PDF

Gas hold-up variation with sparging direction in bubble column (기포탑 반응기에서 기체 분사 방향에 따른 gas hold-up 변화)

  • Yang, Jung Hoon;Yang, Jung-Il;Kim, Hak-Joo;Chun, Dong Hyun;Lee, Ho-Tae;Jung, Heon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.112.2-112.2
    • /
    • 2010
  • 슬러리 기포탑 반응기는 열 및 물질 전달의 용이성, 낮은 운전비용 및 장치의 간단성의 장점을 가지고 있어서 Fischer-Tropsch 반응, bio-reaction 등에 많이 응용되고 있다. 그러나 기포탑 반응기 내의 물질 거동은 매우 복잡하기 때문에 많은 연구가 이루어지고 있음에도 불구하고 그 현상에 대한 명확한 이해는 어려운 상황이다. 특히 기포탑반응기내에 기체의 포집율(gas hold-up)을 증가시키는 것을 목적으로 하는 연구들이 활발히 진행되고 있다. 본 연구에서는 기체의 분사 방향에 따른 기체 포집율의 변화를 관찰하였다. 기체 분사는 0.6 mm의 pore가 66개로 구성된 perforated plate를 통해서 이루어졌고, 수직방향, 수평방향, 45도 그리고 수직/수평 조합의 네 가지 분사방향에 대해서 실험을 수행하였다. 반응기는 내경이 0.15 m이고 높이 2.0 m 아크릴 반응기를 이용하였다. 사용된 연속상은 수돗물을 사용하였고 분산상 기체로는 압축 공기를 이용하였다. 전체적인 기체 포집율은 수직방향의 분사방향에서 가장 높게 측정되었다. 그리고 수직/수평의 조합 분사방향의 경우, 기체 포집율이 가장 낮게 관찰되었다. 이것은 분사방향이 수직/수평으로 서로 엇갈릴 경우, 기포간의 충돌 가능성이 높아지고 bubble coalescence가 증가하였기 때문인 것으로 보인다. 실제로 homogeneous flow regime에서 heterogeneous flow regime으로 전환되는 기체선속도는 분사방향이 수직, 45도, 수평, 수직/수평 조합의 순서로 감소하였다. 즉 이 순서로 기체흐름의 와류가 증가하는 것을 알 수 있었다. 또한 Dynamic Gas Disengagement(DGD) 분석을 통하여 큰 기포가 발생하기 시작하는 기체 선속도의 변화를 관찰하였다. 이 경우, 예상되듯이 수직/수평 조합에서는 1.5 cm/sec 기체 선속도에서 큰 기포가 발생하기 시작한 반면 수직 방향 분사의 경우에는 2.5 cm/sec의 보다 높은 기체 선속도에서 관찰되기 시작하였다. 이러한 현상들을 종합하였을 때, 기체 분사방향을 수직으로 일정하게 했을 때, 기포간 출동을 최소화하고 와류발생을 최대한 지연시키며 전체 기체 포집율을 증가시킬 수 있음을 알 수 있다.

  • PDF

A Study on the Heat Transfer Analysis of High-Temperature Single Bubble in Water (수중 고온 단일 기포의 열전달 해석 연구)

  • SeokTae Yoon
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.29 no.1
    • /
    • pp.117-123
    • /
    • 2024
  • Bubbles generated in water receive an upward buoyant force due to the density and pressure difference of the surrounding fluid. Additionally, the behavior, shape, and heat exchange process of bubbles vary depending on the viscosity, surface tension, rising speed, and size difference with the surrounding fluid. In this study, we modeled speed, and heat transfer of a high-temperature single bubble rising in a cylindrical water tank. For this purpose, velocity, and temperature of the bubbles were calculated using theoretical equations, to be compared with numerical simulation results. The numerical analysis was performed using a commercial software, and the stability of the numerical analysis with mesh size was confirmed through calculation of the grid convergence index. The numerical analysis of the rising speed and temperature of a single bubble showed the values to converge when the minimum cell size was 1/160 of the bubble diameter, and the temperature decrease was confirmed to be the same as that of the surrounding fluid within 0.05 seconds.

A Study on the Measurement of Local Void Fraction (수직사각 유로내에서의 국부적 기포계수 측정에 관한 연구)

  • B.J. Yun;Kim, K.H.;Park, G.C.;C.H. Chung
    • Nuclear Engineering and Technology
    • /
    • v.24 no.2
    • /
    • pp.168-177
    • /
    • 1992
  • The importance of the study of two phase flow phenomena has increased for both fuel performance and safety analysis of nuclear power plants. In the analysis of two phase flow system, an accurate prediction of local void fractions is very important. In this study, a vertical rectangular subchannel having 4 electrically heated rods is constructed for the measurement of local void fraction under two phase flow. The measurement has been conducted by electrical conductivity probes and signal processing circuit which are known to be adequate to measuring local void fraction. Also experiments are performed with varying the inlet flow rate to search for radial void fraction profile accordingly to the different flow rate even with the same averaged void fraction. From the result of experiments, the validity of electrical conductivity probe and electrical circuit is confirmed.

  • PDF

The Prediction of Void Fraction in the Subcooled Boiling Region (서브쿨드 비등 영역에서의 기포계수 계산에 관한 연구)

  • Goon Cherl Park
    • Nuclear Engineering and Technology
    • /
    • v.16 no.4
    • /
    • pp.195-201
    • /
    • 1984
  • A state-of-the-art mechanistic model has been developed to accurately predict the void fraction in the subcooled boiling region having axial nonuniform heat flux. In this study, the void-dependent drift-flux parameters of the Lahey/Ohkawa model were introduced and the mass flux-dependent condensation coefficient were determined by fitting with the experimental data. This model was tested against several experimental data sets to verify its accuracy. Finally the comparison between the predicted void fraction profiles with this model and the profile-fit model for the hot assembly of Kori-Unit 1, Cycle 1 has been performed. It is conclusive that the results show the good agreement between the measured and predicted void fractions, and the profile-fit model has been found to underestimate the void fraction in the subcooled boiling region.

  • PDF

Numerical Study of Low-pressure Subcooled Flow Boiling in Vertical Channels Using the Heat Partitioning Model (열분배모델을 이용한 수직유로에서의 저압 미포화비등 해석)

  • Lee, Ba-Ro;Lee, Yeon-Gun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.7
    • /
    • pp.457-470
    • /
    • 2016
  • Most CFD codes, that mainly adopt the heat partitioning model as the wall boiling model, have shown low accuracies in predicting the two-phase flow parameters of subcooled boiling phenomena under low pressure conditions. In this study, a number of subcooled boiling experiments in vertical channels were analyzed using a thermal-hydraulic component code, CUPID. The prediction of the void fraction distribution using the CUPID code agreed well with experimental data at high-pressure conditions; whereas at low-pressure conditions, the predicted void fraction deviated considerably from measured ones. Sensitivity tests were performed on the submodels for major parameters in the heat partitioning model to find the optimized sets of empirical correlations suitable for low-pressure subcooled flow boiling. The effect of the K-factor on the void fraction distribution was also evaluated.

Bubble Adsorptive Separation of CuS Precipitates (CuS 침전의 기포흡착분리에 관한 연구)

  • Shin, Jeong Ho;Park, Kyung Kee;Jeong, Kap Seop;Lee, Geun Hee
    • Applied Chemistry for Engineering
    • /
    • v.9 no.1
    • /
    • pp.20-27
    • /
    • 1998
  • The characteristics of the bubble adsorptive separation of CTAB(cetyltrimethylammonium bromide) and CuS precipitates was investigated. The Langmuir adsorption equation was adequate at very low concentration of CTAB, and the adsorption heat was determined from the batch analysis considering the bulk liquid accompanied between bubbles. The adsorption mechanism was explained with the collision adsorption between bubbles and precipitate particles. The optimum concentration ratio of (CTAB) to (CuS) for adsorptive separation was 0.1 and coincided with the ratio for the coagulation of particles. The collection efficiency was depended on pH and CTAB concentration but independent of the air flow rate, and the maximum efficiency was 0.0002. The selective separation of ZnS from the mixture of Cu-Cd-Zn sulfides was obtained by the bubble adsorption with CTAB.

  • PDF

Deflection of a Thin Solid Structure by a Thermal Bubble (열 기포에 의한 고체 박막의 변형 해석)

  • Kim, Ho-Young;Lee, Yoon-Pyo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.2
    • /
    • pp.236-242
    • /
    • 2003
  • Thermal bubbles find their diverse application areas in the MEMS (MicroElectroMechanial Systems) technology, including bubble jet printers, microactuators, micropumps, etc.. Especially, microactuators and micropumps, which use a microbubble growing by a controlled heat input, frequently involve mechanical and thermal interaction of the bubble with a solid structure, such as a cantilever beam and a membrane. Although the concept is experimentally verified that an internal pressure of the bubble can build up high enough to deflect a thin solid plate or a beam, the physics of the entire process have not yet been thoroughly explored. This work reports the experimental study of the growth of a thermal bubble while deflecting a thin cantilever beam. A physical model is presented to predict the elastic response of the cantilever beam based on the experimental measurements. The scaling law constructed through this work can provide a design guide for micro- and nano-systems that employ a thermal bubble for their actuation/pumping mechanism.