• Title/Summary/Keyword: 열 간격

Search Result 551, Processing Time 0.035 seconds

An Experimental study of Buckling Behavior in Built-up Compression Member with Unsymmetric Connectors I - Effect of Distance of Connecting Members - (비대칭 연결재를 갖는 조립식 압축부재의 좌굴 거동에 관한 실험 연구 I - 연결재 간격의 영향 -)

  • Kang, Sanghoon;Han, Manyop;Cho, Byeongdu
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.4A
    • /
    • pp.207-215
    • /
    • 2012
  • Structural behavior of built-up compression members with unsymmetric connectors under buckling status has been studied through these experiments. When the distance between adjacent H-300 beams of built-up compression member is 2 m in length, and the H-300 beams are lengthened up to 30 m in length with three-10 m-H-beams by bolts and double arrayed, three specimen having each connector interval 4 m, 5 m, 6 m are experimented for evaluating buckling loads. The buckling loads from the experiments are compared with buckling loads of structural analysis using FEM and buckling loads of Timoshenko Eq. loads in order to figure out how the connectors' interval affects on longitudinal and lateral displacements, also strain of the built-up compression members as well. The result shows that the buckling loads tend to sharply decrease non-linearly according to connectors' interval increases. As well as that, the differences between experimental buckling loads and theoretical buckling loads and between experimental buckling loads and structural analyses buckling loads also have a tendency to be increased as the connector interval increases.

Thermal characteristics of energy textile by performing in-situ thermal response test (현장 열응답시험을 통한 에너지 텍스타일의 열적 거동 평가)

  • Lee, Chulho;Yoon, Sangbong;Han, Eunseon;Jeoung, Jae-Hyeung;Choi, Hangseok
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.167.2-167.2
    • /
    • 2010
  • 본 연구에서는 지열 에너지원으로써 터널 내부 벽면의 항온성을 이용하여 터널 외벽에 텍스타일 형태의 열교환기를 설치하고 열적 거동을 평가하였다. 터널의 라이닝 부분에서는 여러 가지 요인에 의해 지하수가 터널 내부로 유입하게 되므로 지하수의 유무에 대한 열적 거동 및 유동액의 순환 속도에 따른 영향, 열교환 파이프 배열 형태에 따른 영향을 현장 시험 시공과 현장 열응답시험을 통하여 평가하고자 하였다. 또한 3-D 유한체적해석 프로그램(FLUENT)을 이용하여 숏크리트와 라이닝의 열전도도를 고려한 열교환기의 성능을 분석하였다. 수치해석 결과 열교환 파이프 주변에 지하수의 흐름이 존재할 경우 열전달이 상대적으로 더 원활히 이루어졌으며 순환속도가 빠를 때 보다 느릴수록 효율이 높게 나타났다. 또한, 파이프의 간격이 넓을수록, 파이프의 길이가 길수록 효율이 높게 나타났다. 라이닝 및 숏크리트의 열전도도가 증가함에 따라 에너지 텍스타일의 열전달 효율이 높게 나타났다. 현장 시험을 통해 비슷한 길이의 파이프가 사용된 경우, 파이프 배열 형태에 따라 수평형보다는 수직형 배열의 효율이 높게 측정되었다.

  • PDF

A Visualization Tool for Ranked Subsequence Matching in Time-Series Databases (시계열 데이터베이스에서 순위를 지원하는 서브시퀀스 매칭 방법을 위한 시각화 툴)

  • Lee, Sung-Jin;Lee, Jinsoo;Cho, Hune;Han, Wook-Shin
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2009.11a
    • /
    • pp.787-788
    • /
    • 2009
  • 시계열 데이터(time-series data)는 연속적인 데이터를 고정된 시간 간격으로 샘플링한 실수 값들의 연속을 의미한다. 시계열 데이터의 예로는, 음악 및 동영상 데이터, 심전도 데이터, 주식 그래프 등의 데이터가 있다. 시계열 데이터는 다시 데이터베이스에 저장 되어있는 데이터 시퀀스(data sequence)와, 사용자에 의해 주어지는 질의 시퀀스(query sequence)로 분류된다. 시계열 데이터베이스(time-series database)에서 순위를 지원하는 서브시퀀스 매칭 방법(ranked subsequence matching)은 데이터 시퀀스와 질의 시퀀스가 주어졌을 때, 질의 시퀀스의 길이와 같은 데이터 시퀀스의 서브시퀀스(subsequence)들 중에서 질의 시퀀스와 가장 유사한 상위 k개의 서브시퀀스들을 찾는 것이다. 본 논문의 목적은 사용자가 매칭 방법에 대한 인식과 이해가 부족하더라도 기존의 콘솔 기반의 매칭 프로그램을 보다 쉽게 사용할 수 있도록 이용성을 향상시키기 위하여 시각화 툴을 개발하는 것이다. 구체적으로, 5가지 시각화(visualization) 기능을 제공하는 사용자 인터페이스를 구현하였다. 구현된 사용자 인터페이스를 통해 사용자가 기존의 매칭 프로그램을 보다 쉽고 간편하게 사용할 수 있도록 기여한다.

Experimental Investigation of Variations in Inclination Angle of Natural Convective Heat Sink with Plate Fins (플레이트-휜을 가지는 자연대류 히트싱트의 경사각 변화에 대한 실험적 연구)

  • Do, Kyu-Hyung;Kim, Tae-Hoon;Han, Yong-Shik;Choi, Byung-Il;Kim, Myung-Bae
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.6
    • /
    • pp.571-578
    • /
    • 2012
  • In this paper, an experimental investigation is performed to estimate the thermal performance of a natural convective heat sink with plate fins subject to the uniform wall temperature condition. Extensive experiments are performed with various input powers, fin spacings, and heights of the natural convective heat sinks with plate fins. In particular, the effect of the inclination angle on the thermal performance of the heat sink is studied. In order to validate the experimental data, the experimental results are compared with results from previous studies. Based on the experimental results, the appropriate ranges of the previous correlations between the input power, the fin spacing, the fin height, and the inclination angle for the natural convective heat sink with plate fins are evaluated.

Thermo-Hydraulic Characteristics of Two-Dimensional Wavy Channels with Different Shape Parameters (2차원 파형 채널의 형상변화에 따른 열유동 특성)

  • Kim, Ki-Wan;Kim, Sun-Ju
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.1
    • /
    • pp.1-8
    • /
    • 2014
  • Two-dimensional laminar numerical analyses were carried out for investigating the thermo-hydraulic characteristics of wavy channels with different shape parameters ($0.5{\leq}{\in}{\leq}1.5$, $0.1{\leq}{\gamma}{\leq}0.4$). PAO (polyalphaolefin), which is used for electronics cooling, is considered as the working fluid. In addition, constant properties, periodically developed flow, and uniform channel wall temperature conditions are assumed. Streamline and temperature fields, isothermal Fanning friction factors, and Colburn factors are presented for different Reynolds numbers in the laminar region ($1{\leq}Re{\leq}1000$). The results show that heat transfer is enhanced when the channel corrugation ratio (${\gamma}$) is large and channel spacing ratio (${\in}$) is small in the low Reynolds number region (Re < 50) and when ${\in}$ and ${\gamma}$ are large in the high Reynolds number region ($Re{\geq}50$).

Thermohydromechanical Stability Study on the Joint Characteristics and Depth Variations in the Region of an Underground Radwaste Repository (절리 발달 특성 및 심도 변화에 의한 방사성폐기물 처분장 주변영역에서의 열수리역학적 안정성 연구)

  • Kim, Jhinwung;Daeseok Bae;Park, Chongwon
    • Tunnel and Underground Space
    • /
    • v.13 no.2
    • /
    • pp.153-168
    • /
    • 2003
  • The objective of this present study is to understand long term(500 years) thermohydromechanical interaction behavior in the vicinity of a repository cavern on the joint location and repository depth variations. The model includes a saturated discontinuous granitic rock mass, PWR spent nuclear fuel in a disposal canister surrounded with compacted bentonite inside a deposition hole, and mixed bentonite backfilled in the rest of the space within a repository cavern. It is assumed that two joint sets exist within the model. Joint set 1 includes joints of 56$^{\circ}$ dip angle, spaced at 20 m, and joint set 2 is in the perpendicular direction to joint set 1 and includes joints of 34$^{\circ}$ dip angle, spaced at 20 m. In order to understand the behavior change on the joint location variations, 5 different models of 500m in depth are analyzed, and additional 3 different models of 1000 m in depth are analyzed to understand the effect of depth variation.

Reflection and Transmission of Regular Waves by Multiple-Row Curtainwall-Pile Breakwaters (다열 커튼월-파일 방파제에 의한 규칙파의 반사 및 투과)

  • Suh, Kyung-Duck;Ji, Chang-Hwan
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.18 no.2
    • /
    • pp.97-111
    • /
    • 2006
  • Using the eigenfunction expansion method, a mathematical model has been developed to calculate the reflection and transmission of regular waves from a multiple-row curtainwall-pile breakwater. In addition, hydraulic model experiments have been conducted with different values of porosities between the piles, drafts of the curtain walls, and distances between the rows of the breakwater. It is found that the reflection and transmission coefficients decrease and increase, respectively, with decreasing relative water depth, but they bounce to increase and decrease, respectively, as the relative water depth decreases further. When either the porosity between the piles or the draft of the curtain wall is changed with other parameters fixed, the relative magnitudes of the reflection and transmission coefficients have been changed, but the general trend remained the same. When the wavelength is the same as the distance between the rows of the breakwater, a rapid change was observed for the reflection and transmission coefficients. A good agreement between the measurement and prediction was also founded for three-row breakwaters.

The Method of Thermal Crack Control about the LNG Tank Wall in Winter (LNG 저장탱크 벽체의 동절기 온도균열제어 방안)

  • Son, Young-Jun;Ha, Jae-Dam;Um, Tai-Sun;Lee, Jong-Ryul;Baek, Seung-Jun;Park, Chan-Kyu
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.637-640
    • /
    • 2008
  • Since the first underground LNG tank was constructed in Incheon, continuously many LNG tanks were constructed in Tongyoung and Pyongtaek. The storage capacity of LNG tank increased by 200,000kl and the structure size and the concrete mixing design has changed. The crack of concrete induced by the heat of hydration is a serious problem, particularly in massive concrete structures. In order to control the thermal crack of massive concrete, the low heat portland cement(type Ⅳ) is applied to bottom annular part, bottom central part, lower walls and ring beam. In this study, in order to thermal crack control about the LNG tank wall(lot 8 of #16 Pyongtaek LNG tank) in winter, analysed the concrete temperature, the extention of term, the curing condition and the concrete mixing design. When the concrete mixing design is changed from OPC+FA25% to LHC+FA25%, the thermal crack index is 1.33 and satisfied with construction specifications(over 1.2).

  • PDF

Analysis of the Disposal Tunnel Spacing and Disposal Pit Pitch for the HLW Repository Design (심지층 처분시설 설계를 위한 처분터널 및 처분공 간격 분석)

  • 이종열;김성기;김진웅;최종원;한필수
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2003.11a
    • /
    • pp.315-321
    • /
    • 2003
  • In this study, analysis of the disposal tunnel spacing and disposal pit pitch was carried out, as a factor of the design to estimate the scale and layout of the repository To do this, based on the reference repository concept and the engineered barrier concept, the cross section of the disposal tunnel and disposal pit are established and the mechanical and thermal stabilities of the tunnels are analyzed. Also, the optimized disposal tunnel spacing and the disposal pit pitch which minimize the excavation volume was proposed. The detailed analyses by the exact site characteristics data are needed to reduce the uncertainty of the site in the future.

  • PDF

computer-aided-diagnosis by image subtraction in conventional radiography (단순 x선 영상의 차영상을 통한 컴퓨터 도움 진단)

  • 김승환;이수열;박선희;표현봉
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 1999.10b
    • /
    • pp.425-427
    • /
    • 1999
  • 본 논문에서는 시간 간격을 두고 활영한 흉부의 단순 x선 영상의 차영상을 이용하여 컴퓨터 도움 진단에 활용할 수 있는 방법에 대해 연구하였다. 시간 간격을 두고 촬영한 흉부 단순 x선 영상의 차영상은 시간에 따른 변화를 명확히 보여줌으로써 질병의 조기진단 및 질병의 전개과정 등을 알아보는데 유용하게 쓰일 수 있다. 특히, 이 방법은 폐암과 같이 조기진단이 매우 어려운 질병에 대하여 정기검진 등에서 정기적으로 촬영한 단순 x선 영상을 이용하여 조기진단을 할 수 있는 방법으로 활용될 수 있다. 그러나, 촬영시의 여러 가지 조건들, x선의 세기와 조영시간, 환자의 촬영 자세 및 호흡 상태 등에 따라 단순 x선 영상이 크게 달라져 단순한 뺄셈에 의한 차영상은 진단에 도움이 되지 못한다. 진단에 도움을 주기 위해서는 두 영상 사이의 전체적인 밝기와 대조도를 맞추고 늑골, 쇄골 등 해부학적 구조물의 위치와 크기를 서로 맞추어 차영상을 얻는 영상처리 방법이 필요하다. 또한, 폐의 크기와 위치도 서로 맞추어 차영상을 얻어야 한다. 그러나, 이러한 방법도 늑골과 폐의 크기와 위치 변화가 서로 일치하지 않는 문제점을 가지고 있다. 본 논문에서는 이러한 영상처리를 통하여 차영상을 얻는 방법에 대하여 논하고 방법상의 문제점과 해결 방법을 제시한다.

  • PDF