• Title/Summary/Keyword: 열펌프 시스템

Search Result 422, Processing Time 0.03 seconds

Effect of Greenhouse Cooling and Transplant Quality Using Geothermal Heat Pump System (지열-열펌프 시스템의 온실냉방 및 육묘 효과)

  • Lee, Jae-Han;Lee, Yong-Beom;Kwon, Joon-Kook;Kang, Nam-Jun;Kim, Hak-Joo;Choi, Young-Hah;Park, Jin-Myeon;Rhee, Han-Cheol
    • Journal of Bio-Environment Control
    • /
    • v.15 no.3
    • /
    • pp.211-216
    • /
    • 2006
  • This study was carried out to investigate the effect of greenhouse cooling by a geothermal heat pump system on greenhouse temperature and growth of vegetable transplants in summer season. Greenhouse air temperature in day time was $3-4^{\circ}C$ lower in fog plus shading system than in shading, while in night time that was $5-7^{\circ}C$ lower in geothermal heat pump (GHP) plus shading system compared to shading or fogplus shading. system. Plant height of cucumber, tomato and hot pepper transplants was shortened in GHP plus shading compared to shading or fog plus shading system. And Leaf area and dry weight were slightly decreased in GHP plus shading compared to the other systems. Therefore, healthy transplant index on cucumber, tomato and hot pepper was higher in GHP plusshading than in shading or fogplusshading system.

고진공펌프의 상태진단 시스템

  • Jeong, Wan-Seop;Nam, Seung-Hwan;Kim, Wan-Jung;Im, Jong-Yeon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.101-101
    • /
    • 2012
  • 본 논문은 현재 제품화 단계로 진행 중인 터보 분자펌프(turbo-molecular pump, TMP)와 극저온 펌프(cryopump)의 고장 방지 및 예지 보수를 위한 상태 진단 시스템에 대하여 소개를 한다. 본 상태 진단 시스템은 고진공 펌프들의 다중 상태변수 즉 흡/배기부의 진공 압력, 부위별 온도, 소비 전류(혹은 전력), 그리고 부위별 진동 신호들을 실시간으로 측정하는 상태변수 수집장치, 수집된 시계열 상태변수들이 저장된 database, 그리고 저장된 상태변수를 이용한 고진공펌프의 상태진단 프로그램으로 구성되어 있다. 금번 연구에서 구축한 상태변수 체계의 특징 중 하나는 진동신호를 상태변수로 측정하여 이를 상태진단에 활용하는 점이 기존의 접근방법과 상이한 점이다. 실시간 신호 수집장치는 NI사 PXI 시스템 기반의 16채널 24-bit 동시 전압신호 측정 모듈, 8부위의 온도 측정장치(Lakeshore 218S, RS-232C 통신), 그리고 펌프의 소비전류/전력 측정장치(Hioki 3169, RS-232C), 그리고 고진공 펌프의 흡입 및 배기구의 진공도 측정장치로 구성하였다. 신호 수집용 프로그램은 NI사 Labview를 이용하여 작성하였다. 본 장치는 Nano-Fab 센터의 협조 하에 turbo-molecular 펌프와 cryopump측정 단에 각각 1대를 설치 완료하였으며 현재까지 운용 중이다. PC에 저장된 시계열 상태변수 database는 기 개발된 적응형 인자모델을 이용한 매개변수로 변환되며, 상태진단은 변환된 매개변수를 이용하여 수행할 예정이다.

  • PDF

Characteristics of Bubble Mode in the Cylindrical Absorber for Heat Pump System (열펌프 시스템에서 원통형 흡수기 내 기포모드의 특성)

  • 이기봉;전병희;이재철;박찬진;김성현
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 2000.11a
    • /
    • pp.199-204
    • /
    • 2000
  • 산업과 과학발달에 의해 더욱 물질적으로 풍요로워진 인류에게 에너지와 환경문제는 새로운 당면문제로 부각되고 있다. 특히 1992년 몬트리올 협정에서는 CFC 및 HCFC의 사용을 각각 1997과 2002년부터 전면 금지시키기로 하였고, 1997년에는 2008-2012년까지 전세계 온실가스 배출량을 5.2% 줄이는 것을 골자로 하는 교토 선언이 합의되었다. 이러한 상황을 타개하기 위한 많은 연구 중 흡수식 열펌프는 환경친화적인 자연냉매를 사용하는 열구동 시스템으로 다시 주목을 받고 있다. 특히 흡수식 열펌프의 구성요소 중 흡수에 의하여 고온의 열을 얻을 수 있는 흡수기에 효율적인 열·물질전달 모드를 적용함으로써 제품의 소형화와 에너지 손실 감소를 이루고 있다. 이에 본 연구에서는 새로운 흡수기 모드로 연구되고 있는 기포타입모드를 원통형 흡수기에 적용해 보고, 그 특성을 고찰해 보고자 하였다. 흡수기로 유입되는 ammonia gas와 용액을 cocurrnet 및 countercurrent로 흘려주었고, 높이에 따른 농도, 온도 및 압력을 측정·비교해 보았다.(중략)

  • PDF

Computational Design of a 50 kW Chemical Heat Pump System for Air-Conditioning (50 kW 냉방용 화학열펌프 시스템의 전산설계)

  • 서정원;김성준;이태희
    • Journal of Energy Engineering
    • /
    • v.4 no.1
    • /
    • pp.67-75
    • /
    • 1995
  • 50 kW 냉방용 화학열펌프에 관한 전산설계를 하기 위하여 반응기 모사용 부프로그램을 작성하였으며 전체 시스템을 위하여 상용모사기인 ASPEN PLUS를 이용하였다. 반응물로 각각 SrCl2-8/1 NH3 그리고 MnCl2-6/2 NH3를 사용하는 두 시스템에 대하여 비교 연구하였으며, 조작조건에 따라 시스템 설계치의 변화를 관찰하였다. 이로부터 향후 실용화될 화학열펌프 시스템에 대한 기본 설계자료를 제시할 수 있었다. SrCl2-8/1 NH3를 반응물로 한 경우 반응기의 UA는 6,868.2 J/(s·K), 출력은 95.2 kW이었고, 제한 성능 계수는 0.40이었다. MnCl2-6/2 NH3의 경우 UA는 1,569.7 J/(s·K), 출력은 109.0 kW이었으며 제한 성능계수는 0.34이었다. 이로부터 SrCl2-8/1 NH3을 반응물로 한 시스템이 MnCl2-6/2 NH3를 사용한 시스템보다 유리함을 알 수 있었다.

  • PDF

Statistical Analysis on Residuals from No-Fault Reference Models of a Residential Heat Pump System in Normal Cooling Operation (가정용 열펌프 시스템의 정상냉방 운전조건에서 기준모델에 의한 잔차의 통계적 분석)

  • Kim, Min-Sung;Yoon, Seok-Ho;Baik, Young-Jin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.12
    • /
    • pp.1351-1358
    • /
    • 2011
  • To approximate the threshold of the fault detection and diagnosis (FDD) system, validation of the measurements is mandatory. Naturally, the system shows uncertainties due to measuring sensors - mostly thermocouples or RTDs - and due to repeatability. The uncertainty of a thermocouple comes from natural variation or a drift of the thermocouple measurement. Considering the natural variation behaves like zero-mean white noise, its natural variation can be characterized closely by the steady-state standard deviation. However, residuals between measurements and no-fault references in FDD systems show a statistical distribution with various uncertainties. In this paper, steady-state variations of measurement residuals were investigated by utilizing built-in temperature sensors in a heat pump for the model development and the final application.

기술현황분석 - 고효율 열펌프 건조기 기술

  • Lee, Gong-Hun
    • 기계와재료
    • /
    • v.23 no.3
    • /
    • pp.126-136
    • /
    • 2011
  • 지구 온난화에 따라 이산화탄소를 비롯한 온실가스의 감축은 세계적인 관심사이며 모든 산업 분야의 1차 목표가 되고 있다. IEA는 시스템의 고효율화 기술이 2035년까지 목표 감축량의 50% 이상을 달성할 수 있는 기술로 판단하고 있다. 건조기는 대부분의 산업 분야에서 사용되는 필수기계이고 에너지 다소비 기기이므로 건조기의 에너지 효율을 향상시키는 것을 온실가스 감축에 있어서 중요한 부분이라 할 수 있다. 열펌프 건조기는 건조기 중에서도 가장 높은 효율을 달성할 수 있는 장치로서 산업 분야에 활용된다면 큰 역할을 담당할 것으로판단된다. 특히 산업의 많은 분야에 활용되기 위해서는 고온용 열펌프 건조기의 개발이 매우 중요하다. 최근에 국내외에서 고온용 열펌프에 대한 관심이 증가하고 있고, 개발이 일부 진행되었으나 많은 산업분야에 적용 가능하도록 기술을 성숙시키려면 지속적인 연구개발이 필요하다.

  • PDF

Experimental Study on Cooling Performance of Multi-Heat Pump by Indoor-Unit Combination (실내기 조합에 따른 3실형 열펌프의 냉방성능 실험연구)

  • Kwon, Young-Chul;Chun, Chong-Keun;Park, Youn-Chang;Ko, Kok-Won;Seo, Dong-Nam
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.6
    • /
    • pp.1487-1493
    • /
    • 2008
  • In order to investigate the cooling capacity of multi-heat pump applying an inverter compressor, the experiment on the cooling performance characteristics of heat pump with 3 indoor units was performed under the cooling standard and cooling low-temperature conditions. The system data were measured by the psychrometric calorimeter. The operation characteristics and the behavior of the cooling cycle of the heat pump with 3 indoor units were understood from the cooling capacity, COP, and P-h diagram by indoor-unit combination. The operating load and performance of the multi-heat pump depends on the indoor-unit combination. The cooling capacity and COP of the low temperature condition were larger than those of the standard one. Also the cycle was analyzed by using P-h diagram.

열전식 열펌프의 원리와 응용

  • 주해호
    • Journal of the KSME
    • /
    • v.25 no.5
    • /
    • pp.400-405
    • /
    • 1985
  • 펠티어효과가 10여년 전에 발견되었으나 이것을 공학분야에 응용되기 시작한 것은 반도체 재료가 개발되기 시작한 1950년경부터 실용화되기 시작하였다. 이러한 열전식 열펌프를 이용하여 냉 각시스템을 만들 경우 재래식인 기계식 냉동시스템과 비교해 볼 때 여러 가지 장점이 있다. 열전식 냉동방법은 전자가 한 반도체에서 다른 반도체로 이동하면서 그 주위의 열과 함께 이동 하는 원리를 이용한 것이기 때문에 기계식 냉동시스템의 중요한 구성품인 압축기, 증발기, 응 축기, 용매제와 같은 부품이 전혀 필요가 없다. 움직이는 부품이 없기 때문에 소음이 없고 신 뢰성이 높다. 100W 보다 적은 열출력에 대해서는 무게가 적고 부피가 적은 장점이 있다. 또한 습도 제어가 정확하고 전류의 방향만 바꾸워 주면 쉽게 냉동에서 가열로 전환이 된다. 작동습 도범위는 제품에 따라 다르지만 대개 +100.deg.C~ -125.deg. C까지 가능하다. 이러한 장점 때 문에 가장 많이 응용되고 있는 분야는 군사무기인 관성항법유도무기의 전자부품실을 냉각시켜 주는 데 사용되고 그 외에 용도는 다양하다. 본 고에서는 열전식 열펌프의 원리와 그 응용에 대해서 가능한 상세히 설명하여 앞으로 이 분야에 대한 연구에 보템이 되고저 한다.

  • PDF