• 제목/요약/키워드: 열펌프시스템

검색결과 422건 처리시간 0.023초

스크류 2단 압축 열펌프 시스템의 운전 제어 방안에 관한 연구 (A Study on the Operating Control of a 2-Stage Heat Pump System with Screw Compressors)

  • 김지영;백영진;이영수;나호상
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.501-505
    • /
    • 2006
  • A preliminary performance test of a 30RT 2-stage screw heat pump was carried out in order to develop a high performance large-scale unutilized energy source heat pump, which will be used in district heating and cooling. Two issues on the system control were investigated in this study, A stable 2-stage heating operation is guaranteed only if the load-side water inlet temperature is over a certain value, to where the 1-stage heating operation should be done first from a cold start. An oil shortage problem in low stage compressor, which depends on the degree of suction superheat, was solved by the proper oil level control scheme.

  • PDF

지열원 열펌프 시스템의 에너지 생산량 모니터링 신뢰도 향상 방안 연구 (A Study on the Monitoring Methods for Energy Production in Ground Source Heat Pump System)

  • 강신형;이광호;도성록;최종민
    • 한국지열·수열에너지학회논문집
    • /
    • 제15권2호
    • /
    • pp.10-16
    • /
    • 2019
  • In this study, the present regulation of heat metering for the ground source heat pump was investigated. The ground source heat pump has been adopting the heat metering system used in the district heating system for estimating the heating and cooling energy production amount. The accuracy of the present heat metering systems for a water to water ground source heat pump is low, because the system for district heating has a relatively high temperature range comparing with the ground source heat pump operating conditions. Even though the heat amount for the building side should be measured, the heat absorption and extraction amount from or to the ground was measured for the water to air ground source heat pump due to the difficulty of estimating the air side heating and cooling capacity in the present regulation. It is highly recommended to validate the heat metering system to have reliability for the ground source heat pump and develop the system to be applicable water to air ground source heat pump.

수주지열정 지열원 열펌프 시스템의 집단주거시설 적용을 위한 기반 기술 분석 (A Study on the SCW Ground Source Heat Pump System Technologies for Residential Cluster Homes)

  • 이광호;도성록;최종민
    • 한국지열·수열에너지학회논문집
    • /
    • 제15권3호
    • /
    • pp.14-20
    • /
    • 2019
  • In this study, the technologies and regulations for distributing standing column well(SCW) ground source heat pump systems to the residential cluster homes were investigated. They have only been installed in the public or commercial building having different load pattern and site structure compared with the residential cluster homes. Some of SCWs for the residential cluster homes should be installed under the basement due to a lack of site area. There are pressure differences between the SCWs installed under ground surface and basement. It is needed to develop the technology or devices to prevent overflow caused by pressure difference among the SCWs. In addition, heat balance algorithm between SCWs should be adopted to maximize the system efficiency. A heat pump having heating, cooling, hot water, heating-hot water, and cooling-hot water modes should be developed for adopting an individual air-conditioning system to the residential cluster homes.

Facade 일체형 태양열 집열기를 갖는 태양열/지열 하이브리드 시스템의 태양열 집열시스템 작동특성 연구 (A Study on the Operating Characteristics of Solar Collecting System in Solar Thermal/Geothermal Hybrid System with Facade Integrated Solar Collector)

  • 백남춘;이진국;유창균;윤응상;윤종호
    • 한국태양에너지학회 논문집
    • /
    • 제30권5호
    • /
    • pp.69-76
    • /
    • 2010
  • In this study, the solar thermal and geo-source heat pump(GSHP) hybrid system for heating and cooling of Zero Energy Solar House(ZESH) was analyzed by experiment. The GSHP in this hybrid system works like as aback-up device for solar thermal system. This hybrid system was designed and installed for Zero Energy Solar House (KIER ZeSH) in Korea Institute of Energy Research. The purpose of this study is to find out that this system is optimized and operated normally for the heating load of ZeSH. The analysis was conducted as followings ; - the thermal performance of facade integrated solar collector - the on/off characteristics of solar system and GSHP - the contribution of solar thermal system. - the performance of solar thermal and ground source heat pump system respectively. - the meet of thermal load (space and water heating load). This experimental study could be useful for the optimization of this system as well as its application in house. This hybrid system could be commercialized for the green home if it is developed to a package type.

흡수식 2중효용 시스템의 증발기 열원으로 태양열을 이용하는 LiCl 수용액 난방시스템 해석 (Analysis of Thermodynamic Design Data of Double-Effect Absorption System for Heating using LiCl-water for Evaporator Heating Source of Solar Energy)

  • 원승호
    • 한국태양에너지학회 논문집
    • /
    • 제24권3호
    • /
    • pp.39-46
    • /
    • 2004
  • In this paper, thermodynamic design data for heating of double-effect absorption system using LiCl-water for evaporator heating source of sofar energy are investigated for the water-LiCl pair and a comparative study of the water-LiCl pair with the water-LiBr pair is given used for the computer simulation. The computer simulation is based on mass, material and heat balance equations for each part of the system. Coefficients of performance and flow ratios for effects of different operating temperatures are investigated. It is found that the heating COP is higher for the water -LiCl pair than for the water-LiBr pair, and FR is lower for the water-LiCl pair than for the water LiBr pair.

100kW급 연료전지 열관리 시스템 실도로 운전조건 해석적 연구 (Analytic study on thermal management operating conditions of balance of 100kW fuel cell power plant for a fuel cell electric vehicle)

  • 이호성;이무연;조중원
    • 한국산학기술학회논문지
    • /
    • 제20권2호
    • /
    • pp.1-6
    • /
    • 2019
  • 본 연구의 목적은 100kW급 연료전지 시스템의 열관리 성능을 실도로 운전조건에서 분석하여, 성능 해석 모델링을 개발하는 것이다. 개발된 모델을 적용하여, 열관리 시스템의 운전조건 변화에 따른 성능 변화를 고찰하고자 한다. 해석 모델링은 핵심부품들에 대한 성능 평가 데이터를 바탕으로, 성능에 영향을 주는 변수들로 개발하였다. 개발된 연료전지 열관리 시스템 해석 모델링으로 다양한 실차 운전조건에서의 최적 열관리 시스템에 대한 전력소비량을 분석하였다. 주요하게, 연료전지 열관리시스템 핵심부품(워터펌프, 냉각 팬, 3 Way Valve, 라디에이터)에 대한 성능 특성 분석 후 모델링을 진행하였다. 개발된 모델링으로 운전조건에 따른 유량 예측을 하였고, 실험값과 예측값과의 비교분석을 통하여서, 해석 모델링에 대한 검증을 진행하였다. 과도해석을 통하여서, 냉시동시 냉각수 온도가 특정온도까지의 소요시간을 예측하였다. 스택 운전조건에서 스택 입출구 온도가 적정 수준에서 움직이기 위한 열관리 시스템 운전조건에 대한 예측을 진행하였다. 그 결과를 바탕으로, 소모전력과 열방출량과의 비교분석을 하였다. 개발된 해석 모델링은 핵심부품들의 성능 변화시 연료전지 시스템 운전에 대한 영향도를 분석할 수 있도록 활용할 예정이다.

열응답시험을 이용한 수평형 지중열교환기 열특성 연구 (A Study on the Thermal Characteristics of Horizontal Ground Heat Exchanger using Thermal Response Test)

  • 장근선;김민준;김영재
    • 한국산학기술학회논문지
    • /
    • 제17권3호
    • /
    • pp.24-30
    • /
    • 2016
  • 현재까지 지열 열펌프 시스템의 지중열교환기는 수직 밀폐형과 개방형 지중열교환기가 주로 설치되어 열응답시험을 이용한 열특성 평가가 수행되어 왔다. 본 논문에서는 열응답시험과 선형열원법을 이용하여 수평형 지중열교환기의 열특성을 분석하였다. 또한 지열 열펌프 시스템은 매일 단속 운전되어지므로 일일부하시험을 수행하여 수평형 지중열교환기의 지중온도 및 순환수 평균온도 일별 변화를 고찰하였다. 시험을 위해 경기도 안산에 직선식 수평형 지중열교환기(심도 2 m, 길이 50 m 8줄)를 설치하였다. 시험결과 수평형 지중열교환기의 지중 열전도율은 연중 $1.43{\sim}1.64W/m{\cdot}K$ 범위로 비교적 큰 변화가 없으며 12월에 최대값을, 5월에 최소값을 갖는 것으로 나타났다. 12일간 지중 열교환기로 하루 10시간동안 6.0 kW의 열량을 투입하는 연속 부하시험을 6월, 9월, 12월에 수행한 결과 지중온도는 이 기간 동안 각각 $4.31^{\circ}C$, $3.14^{\circ}C$, $1.21^{\circ}C$ 상승하는 것으로 나타났다.

그라우팅 재료가 지중 유효열전도도에 미치는 영향 (Effect of Grouting Materials on Ground Effective Thermal Conductivity)

  • 손병후
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.3371-3376
    • /
    • 2007
  • The design of a ground-source heat pump system includes specifications for a ground loop heat exchanger where the heat transfer rate depends on the thermal conductivity of the ground. To evaluate this heat transfer property, in-situ thermal response tests on four vertical test boreholes with different grouting materials were conducted by adding a monitored amount of heat to water over various test lengths. By measuring the water temperatures entering and exiting the loop, water flow rate, and heat load, effective thermal conductivity values of the ground were determined. The effect of increasing thermal conductivity of grouting materials from 0.82 to 1.05 W/m$^{\circ}C$ resulted in overall increases in effective ground thermal conductivity by 25.8% to 69.5%.

  • PDF

지열 이용 히트펌프 시스템의 열성능 해석 (Analysis of Thermal Performance of Ground-Source Heat Pump System)

  • 신우철;백남춘;김욱중;고득용
    • 한국태양에너지학회 논문집
    • /
    • 제26권2호
    • /
    • pp.95-101
    • /
    • 2006
  • The purpose of this study is to present the simulation results and an overview of the performance assessment of the Ground-Source Heat Pump(GSHF) system. The calculation was performed for two design factors: the spacing between boreholes and the depth of the vertical ground heat exchangers. And the simulation was carried out using the thermal simulation code TRNSYS with new model of water to water heat pump developed by this study. As a result, it was anticipated that the yearly mean COPs of heat pump for heating and cooling are about 3.7 and 5.8 respectively and the heat pump can supply 100% of heating and cooling load all the year around.

사무용건물에서 지열히트펌프냉난방시스템의 운전성능 평가 (Performance for Geothermal Heating & Cooling System by Heatpump in Office Building)

  • 안형준;백성권;조정식;손병후
    • 한국지열·수열에너지학회논문집
    • /
    • 제3권1호
    • /
    • pp.23-29
    • /
    • 2007
  • For the perfomance test of geothermal system, a large pilot of capacity of 50RT is built and operated in office building. This system is planed hybrid system with cooling tower as asisstance heat sink. From October, 2004 to September, 2005, this system is operated andmonitored. As the result, COP of heating periods is about 3.46 and COP of cooling periods is about 4.1. Therefore, geothermal system is useful and suitable in Korea.

  • PDF