• Title/Summary/Keyword: 열탈착

Search Result 121, Processing Time 0.03 seconds

The Effect of the Crystalline Phase of Zirconia for the Dehydration of Iso-propanol (이소프로판올의 탈수반응에서 지르코니아 촉매의 결정상에 따른 영향)

  • Sim, Hye-In;Park, Jung-Hyun;Cho, Jun Hee;Ahn, Ji-Hye;Choi, Min-Seok;Shin, Chae-Ho
    • Korean Chemical Engineering Research
    • /
    • v.51 no.2
    • /
    • pp.208-213
    • /
    • 2013
  • Zirconium hydroxide was synthesized by varying the aging time of the zirconyl chloride octahydrate at $100^{\circ}C$ in aqueous solution and the resulting hydroxides were calcined at $700^{\circ}C$ for 6 h to obtain the crystalline $ZrO_2$. The materials used in this study were characterized by differential thermal analysis (DTA), X-ray diffraction (XRD), $N_2$-sorption, transmission electron microscopy (TEM), $NH_3$ temperature-programmed desorption ($NH_3$-TPD), $CO_2$-TPD and iso-propanol TPD analyses to correlate with catalytic activity for the dehydration of iso-propanol. The pure tetragonal $ZrO_2$ phase was obtained after 24 h aging of zirconium hydroxide and successive calcination at $700^{\circ}C$. The increase of aging time showed the production of smaller particle size $ZrO_2$ resulting that the higher specific surface area and total pore volume. $NH_3$-TPD results revealed that the relative acidity of the catalysts increased along with the increase of aging time. On the other hand, the results of $CO_2$-TPD showed the reverse trend of $NH_3$-TPD results. The best catalytic activity for the dehydration of iso-propanol to propylene was shown over $ZrO_2$ catalyst aged for 168 h which had the highest $S_{BET}$ ($178\;m^2\;g^{-1}$). The catalytic activity could be correlated with high surface area, relative acidity and easy desorption of iso-propanol.

A Study on Hybrid DeNOx Process Using Selective Catalytic Reduction and Adsorption (선택적촉매환원과 흡착을 이용한 복합 탈질공정 연구)

  • Moon, Seung-Hyun;Jeon, Dong-Hwan;Park, Sung-Youl
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.12
    • /
    • pp.1329-1336
    • /
    • 2007
  • This study was carried out to develop an efficient process abating high NO concentration. A hybrid process of selective catalytic reduction(SCR) and activated carbon fiber(ACF) adsorption was newly designed and tested. Used ACF in NO adsorption was regenerated by simultaneously applying heat and vacuum. The result of ACF regeneration was for superior in the desorption condition at $140^{\circ}C$ and vacuum 600 mmHg. A commercial catalyst was used at the conditions of reaction temperature at $300^{\circ}C$, $NH_3/NO$ mole ratio = 1.0 for SCR process. NO evolved from ACF regeneration reactor could be removed by SCR reactor up to 98%. But high concentration of NO was exhausted from SCR reactor for one minute when the flue gas of NO 300 ppm and deserted NO from ACF regeneration were simultaneously treated by the same SCR reactor. Therefore, it is necessary to use additional small sized SCR reactor or to increase $NH_3$ concentration for a short time along with NO concentration rather than to mix flue gas with the gas evolving from ACF regeneration at fixed $NH_3$ inlet concentration. The hybrid process of SCR and ACF showed high NO removal efficiency over 80% at any time courses. Through the repeated cycles, stable DeNOx efficiency was maintained, indicating that the hybrid process would be a good countermeasure to the spotaneously high NO concentration instead of increasing the SCR capacity.

Characterization of Charcoals prepared by Korean Traditional Kiln (우리나라 전통 숯가마로부터 생산된 숯의 특성분석)

  • An, Ki Sun;Kwak, Lee Ku;Kim, Hong Gun;Ryu, Seung Kon
    • Korean Chemical Engineering Research
    • /
    • v.60 no.2
    • /
    • pp.208-216
    • /
    • 2022
  • Surface morphology and adsorption characteristics of black and white charcoals prepared from Korean traditional kiln were quantitatively analyzed. TGA and elemental analysis of charcoals were different from produced kiln, and thermal degradation temperature and carbon content of white charcoals were apparently higher than those of black charcoals. Surface morphology shows the activation progressed through the longitudinal direction of woods and new micropores were developed to radial direction on the surface of macropores as the furthermore activation resulting in the pore connection. BET adsorption isotherms show that there are low-pressure hysteresis due to the no desorption of adsorbates, which resulted in unique Type of charcoals overlapping Type I and Type IV. Such a low-pressure hysteresis is occurred from expansion of adsorbates, which were embedded in the micropore entrances and did not get out during the desorption run. The characteristics of charcoals such as specific surface area and pore size distribution did not show correct values depending on not only produced company but also sampling sites of one piece of charcoal. Therefore, it is not easy to suggest the quantitative characteristics of charcoals prepared from Korean traditional kiln. On the other hand, preparation the quality standard of charcoal is necessary for their special uses such as adsorbent.

Changes in the gas chromatographic sensitivity with its analytical setting: Comparison of TDU and loop-injection system for the analysis of sulfur compounds (GC 분석 시스템의 설정과 그에 따른 감도의 차이: 열탈착 방식 대비 루프주입방식에 의한 황성분의 분석)

  • Kim, Ki-Hyun;Choi, Y.J.;Kim, S.C.
    • Analytical Science and Technology
    • /
    • v.18 no.1
    • /
    • pp.66-73
    • /
    • 2005
  • In this study, we investigated the gas chromatography (GC) and pulsed flame photometric detection (PFPD) system for the analysis of four major reduced S compounds including hydrogen sulfide ($H_2S$); methyl mercaptan ($CH_3SH$); dimethyl sulfide (DMS); and dimethyl disulfide (DMDS) contained in environmental samples. To analyze these compounds in high concentration range (above ppb level), we developed a high mode analytical setting with the loop-injection system. By contrast, we also established a low mode setting for the analysis of low concentration samples (ppt-level samples from ambient air) by the combination with thermal desorption unit (TDU). Comparative analysis of both settings revealed that relative detection properties of four S compounds are systematic enough. The results of high mode analysis indicated that the patterns were systematic among S compounds: $H_2S$ exhibited the lowest sensitivity, while DMDS showed the strongest one. The results were also compared in terms of sensitivity reductions for all compounds by dividing slope ratios between low and high mode system. Although low mode system exhibited significant reductions on the order of a few tens times, their detection characteristics were highly consistent as it was shown in the high mode setting. To learn more about absolute and relative relations between two different modes of S analysis, future studies may have to be directed to cover more complicated nature of GC/PFPD performance.

Development of Portable Preconcentration-Gas Chromatography System for Fast Analysis of Trace Benzene, Toluene and Xylene in Air (대기 중 극미량의 벤젠, 톨루엔 및 자일렌의 신속한 분석을 위한 휴대용 농축-기체 크로마토크래피 시스템 개발)

  • Jung, Young-Rim;Kim, Man-Goo
    • Analytical Science and Technology
    • /
    • v.14 no.5
    • /
    • pp.432-441
    • /
    • 2001
  • An automated on-line portable preconcentration-short column gas chromatograph was developed, which used preconcentrator using adsorption tube with Tenax-GR and Curie-point heating. The developed system operated with 3 steps of processing, preconcentration, thermal desorption, and analysis and cleaning, and could continued operating within 1~2 min cycle. The recoveries of preconcentrator for toluene was ranged between $94.7{\pm}6.6%$ and $103.8{\pm}3.1%$ with less than 7% of RSD. For benzene, toluene and xylene(BTX) standard gas test, IDL was 41, 49, $472ng/m^3$ benzene, toluene and o-xylene, respectively. The BTX mixture was analyzed within 30 sec with baseline separation by the system equipped with 4 m long capillary column. The deficiency of separation power caused by short column was solved by the control of sample injection volume and inlet/outlet pressure ratio. The automated portable preconcentration-short column gas chromatograph system was found to be useful for the continuous air monitoring of BTX at ppb levels in ambient air.

  • PDF

Induction Heating Device for Dental Implant Removal (인공치아의 임플란트 탈착을 위한 유도가열장치 연구)

  • Lee, Sang-Myung;Seo, Young;Song, Chang-Woo;Lee, Seung-Yop
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.5
    • /
    • pp.305-311
    • /
    • 2016
  • Induction heating is the process in which an electrically conducting object (usually a metal) is heated by electromagnetic induction through heat generated in the object by eddy currents. The main advantage of an induction heating device is the generation of the heat inside the target object itself. Hence, non-contact and safe heating devices are widely used in many industrial and medical fields. Recently, a new dental implant system was developed using a shape-memory alloy, wherein an artificial tooth could be easily removed from the dental implant by heating. This paper discusses the development of an induction-heating device to remove the dental crown in the new implant system. First, the finite element simulation of electromagnetic and thermal coupling analysis was implemented to obtain the temperature distributions of the target object for various frequencies, input currents, and coil shapes. Based on the simulation results, experiments were conducted by using prototypes, and an induction heating device was developed to remove the dental crown from the implant.

Evaluation of Methodology for the Measurement of VOCs in the Air by Adsorbent Sampling and Thermal Desorption with GC Analysis (흡착포집 및 열탈착/GC 분석에 의한 공기 중 휘발성 유기화합물의 측정방법론 평가)

  • 백성옥;황승만;박상곤;전선주;김병주;허귀석
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.15 no.2
    • /
    • pp.121-138
    • /
    • 1999
  • This study was carried out to evaluate the performance of a sampling and analytical methodology for the measurement of selected volatile organic compounds (VOCs) in the ambient air. VOCs were determined by the adsorbent tube sampling and automatic thermal desorption coupled with GC/FID and GC/MSD analysis. Target analytes were aromatic VOCs, including BTEX, 1,3,5-and 1,2,4,-trimethylbenzenes(TMBs), and naphthalene. The methodology was investigatedwith a wide range of performance criteria such as repeatability, linearity, lower detection limits, collection efficiency, thermal conditioning, breakthrough volume and calibration methods using internal and external standards. standards. Stability of samples collected on adsorbent tubes during storage was also investigated. In addition, the sampling and analytical method developed during this study was applied to real samples duplicately collected in various indoor and outdoor environments. Precisions for the duplicate samples and distributed volume samples appeared to be well comparable with the performance criteria recommended by USEPA TO-17. The audit accuracy was estimated by inter-lab comparison of both duplicate samples and standard materials between the two independent labs. The overall precision and accuracy of the method were estimated to be within 30% for major aromatic VOCs such as BTEX. This study demonstrated that the adsorbent sampling and thermal desorption method can be reliably applied for the measurement of BTEX in ppb levels frequently occurred in common indoor and ambient environments.

  • PDF

Compact $H_2$ PSA process for Hydrogen station (수소 station을 위한 Compact형 $H_2$ PSA 공정 실험)

  • Lee, Jang-Jae;Woo, Eun-Ji;Kim, Myung-Jum;Lee, Chang-Ha
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.118-121
    • /
    • 2007
  • 수소 스테이션의 수소분리정제를 위한 Compact 형 PSA를 연구하였다. 수소 스테이션의 공정과정 중에서 수소 분리를 위한 PSA 장치는 에너지효율면에서 장점을 가지고 있지만 부피가 커서 많은 부지를 차지하는 단점이 있다. 수소 PSA의 이러한 단점을 줄이기 위하여 하나의 흡착탑 안에 다른 흡착탑을 넣는 Dual bed 형태의 Compact형 수소 PSA공정을 연구하였다. Compact형 수소 PSA는 하나의 bed안에 다른 하나의 bed를 넣음으로써 시스템이 차지하는 부피를 줄이는 한편, inner bed와 outer bed사이의 열교환 효과가 나타나기 때문에 그 효율을 높일 수가 있다. Compact형 Dual bed는 활성탄으로 충진하였고 공급 기체로는 4성분 수소 혼합물 ($H_2/CO/CH_4/CO_2$, 69:2:3:26 vol.%)를 사용하였다. 흡착탑의 동특성을 알아보기 위하여 공급유량 7LPM, 흡착압력 9atm의 조건으로 파괴 실험을 수행하였다. 또한, Compact형 흡착탑의 열교환 효과가 PSA공정에 미치는 영향을 보고자 한 쪽 탑에서 흡착을 할 때, 다른 탑에서 탈착이 일어나는 실험을 하였다. 그리고 P/F ratio에 따라 Compact형 PSA 공정 실험을 하고 Compact형 흡착탑과 같은 부피의 일반 두 탑 PSA 공정을 시뮬레이션 값과 비교함으로써 Compact형 PSA의 성능을 알아 보았다. 그 결과 Dual bed PSA는 작은 부피를 차지하는 장점뿐만 아니라 열적 효과로 인하여 기존의 단일 흡착탑 PSA에 비하여 보다 높은 효율을 나타내면서 우수한 수소 분리 성능을 보여주었다.

  • PDF

In situ FT-IR Study of 1,2-dichlorobenzene Decomposition over VOx/Mesoporous Titania by Prepared Spray Pyrolysis (분무 열분해법을 이용해 제조된 VOx/Mesoporous Titania 상에서 1,2-dichlorobenzene의 분해반응에 대한 in situ FT-IR 연구)

  • Jeon, Jong-Ki;Jung, Kyeong Youl;Park, Young-Kwon
    • Applied Chemistry for Engineering
    • /
    • v.22 no.5
    • /
    • pp.582-585
    • /
    • 2011
  • In this study, surface-adsorbed species of 1,2-dichlorobenzene (1,2-DCB) on mesoporous $V_2O_5/TiO_2$ catalysts synthesized by spray pyrolysis were investigated through the adsorption/desorption performed using in situ FT-IR cell. Also, the comparison of adsorbed species with $TiO_2$ and $V_2O_5/TiO_2$ synthesized by the incipient wetness was carried out.

Removal of Pb(II) from Aqueous Solution Using Hybrid Adsorbent of Sericite and Spent Coffee Grounds (견운모와 커피찌꺼기 복합 흡착제를 이용한 수용액의 Pb(II) 제거)

  • Choi, Hee-Jeong
    • Applied Chemistry for Engineering
    • /
    • v.29 no.5
    • /
    • pp.571-580
    • /
    • 2018
  • In this study, hybrid adsorbents (SS) were prepared by mixing spent coffee grounds (SCG) and sericite, a kind of clay minerals, to adsorb Pb(II) from an aqueous solution. In FT-IR analyses, the main functional groups of SS adsorbents were O-H, C=O and C-N groups. The specific surface area, cation exchange capacity and the pore diameter of SS were larger than those of using SCG and sericite. Formation conditions of the SS adsorbent were the optimum pyrolysis temperature of $300^{\circ}C$, SCG : sericite ratio of 8 : 2, and particle size of 0.3 mm. Langmuir adsorption isotherm was more suitable than Freundlich one, and the maximum adsorption capacity was reached 44.42 mg/g. As a result of the adsorption thermodynamic analysis, the adsorption of Pb(II) onto SS was the physical adsorption and exothermic process in nature. The regeneration of SS adsorbent using distilled water showed 88~92% recovery and the active site of SS adsorbent decreased with increasing the reuse cycle time. As a result, SS adsorbent showed that it can be used to remove Pb(II) easily, inexpensively and efficiently without any pre-treatment from aqueous solutions.