• Title/Summary/Keyword: 열전 특성

Search Result 2,558, Processing Time 0.041 seconds

Fabrication and Characteristics of Thin-film Neutron Thermopile for Reactor Instrumentation (원자로계측을 위한 박막중성자열전대의 시작 및 특성)

  • 김동훈
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.9 no.5
    • /
    • pp.1-5
    • /
    • 1972
  • In order to improve the response time of nelltron theromopile for reactor control a neutron thermopile made use of a vacuunl evaporated thin film thor mocouple was fablicated and tested. The test results were compared with a wire-type neutron thermopile. Good linearities between the response of the neutron thermopile and the thermal flux has been shown in the ranges from n/$\textrm{cm}^2$/sec. Thermal neutron flux distributions in the core of TRIGA Mark-II reactor were measured using the fabricated neutron thermopile, and the results were conpared with data obtained by the acrivatin foil measurement.

  • PDF

건축물 에너지절약 설계기준 개정에 따른 온돌시스템 기술개발 방향

  • 강재식;이승언
    • 월간 기계설비
    • /
    • s.143
    • /
    • pp.60-74
    • /
    • 2002
  • 건축물의 에너지 이용을 효율화하기 위하여 단열기준 등을 기존보다 20% 이상 강화하는 것을 골자로 하는 건축물의 에너지절약 설계기준(건설교통부 고시 제2001-118호)이 지난해 6월 1일부터 시행되고 있다. 개정 기준의 가장 큰 특징은 단열기준의 적용 부위를 외기에 직접 면한 부위와 간접 면한 부위로 구분하고, 지역을 중부와 남부, 제주도로 구분$\cdot$설정하여 부하조건과 에너지 소비특성에 따라 건축물의 단열기준을 세분화한 것이다. 특히, 종래에는 최하층 바닥에만 적용하였던 거실 바닥(온돌)의 단열기준을 중간층까지 확대$\cdot$적용하였고, 여기에 온돌시스템의 열적 특성을 고려하여 단열기준의 적용 부위를 보다 구체적으로 설정하고 있다. 따라서 종래의 온돌시스템에서 채움층으로 일반적으로 사용하고 있는 현장 타설식 경량기포콘크리트의 열전도율이 0.13W/mK 내외임을 고려한다면 현행 습식온돌시스템의 열관류율은 $1.0W/m^{2}K$ 이상이 될 것으로 예상됨으로서 앞으로 온돌시스템의 배관층 하부에 $1.0m^{2}K/W$ 이상의 열전도저항을 지닌 단열층이 구성되어야만 개정기준에서 정하는 열관류율 $0.81W/m^{2}K$(기준층 기준)의 성능과 배관하부의 열전도저항값 적용비율을 만족할 수 있을 것으로 판단된다.

  • PDF

Numerical Analysis of Forced and Mixed Convection around the Circular Cylinder for Compressible Flow (압축성 유동장에서의 원형 실린더 주위의 강제 및 혼합대류에 대한 수치 해석)

  • 최윤호;이현찬;유재석;김기현
    • Journal of Energy Engineering
    • /
    • v.4 no.1
    • /
    • pp.126-139
    • /
    • 1995
  • 저속의 압축성 유동장에서의 원형 실린더 주위의 유동 및 열전달특성을 해석하였다. 비압축성 유동장에서의 실린더 주위의 유동 및 열전달현상에 대하여는 실험과 수치해석을 포함한 광범위한 연구가 진행되어 왔으며 매우 잘 알려져 있다. 실린더 벽면과 주위 유동장의 온도차가 큰 경우, 밀도의 변화가 커지므로 유동장은 압축성 유체가 되나 지배 방정식의 복잡함과 적절한 수치해석 방법의 부족으로 실린더 주위의 유동장을 압축성유체로 해석한 경우는 매우 드물다. 현재 압축성유동 해석에 널리 사용되는 time marching algorithm은 저속의 유동장 해석시 지배방정식에 나타나는 eigenvalue들의 괴리에 의하여 수렴속도가 현저히 떨어지게 된다. 본 연구에서는 이와 같은 난점을 극복할 수 있는 time-derivative preconditioning 방법을 사용하여 온도차가 큰 유동장에서의 강제 및 혼합대류에 대한 계산을 수행하였고 이들의 열전달특성을 비교하였다. 강제대류의 경우 실린더 벽면 온도의 증가에 따른 밀도 감소의 영향은 유동장의 Re수를 감소시켜 확산의 영향을 증가시키면서, 혼합대류의 경우 부력의 영향은 가열되는 유동장의 범위와 재순환 영역을 강제대류에 비해 현저히 감소시킨다.

  • PDF

Transfer Characteristics of Porous Metallic Salt-Expanded Graphite Reactive Media (금속염-팽창흑연 다공성 반응매체의 전달특성)

  • 한종훈;김상욱;이건홍
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1999.05a
    • /
    • pp.207-212
    • /
    • 1999
  • 화학반응이 일어나는 고정층 반응기의 성능을 모사하고 해석하기 위해서는 반응베드의 열 및 물질전달 특성을 정확히 아는 것이 중요하다. 본 연구에서는 화학열펌프에 사용되는 금속염-팽창흑연 다공성 반응매체의 유효열전도도와 기체투과도를 측정하였다. 유효열전도도는 전이 일차원 열류기법을 이용하여 측정하였고, 기체투과도는 Darcy's law를 이용하여 측정하였다. 팽창흑연이 함유된 반응베드의 유효열전도도와 기체투과도는 흑연을 기준으로 한 겉보기밀도에 따라 각각 14.1-36.5 W/mK, 8.0x$10^{-15}$-$10^{-12}$ $m^2$의 범위에 있었다.

  • PDF

Transfer characteristics and performance test of reactive block for chemical storage system (화학 축열 시스템용 반응 블록의 전달 특성 및 성능 평가)

  • 황용준;한종훈;김상욱;이건홍
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1999.11a
    • /
    • pp.181-186
    • /
    • 1999
  • 화학 축열 시스템의 성능을 모사하고 이를 해석하여 시스템 성능을 최적화하기 위해서는, 반응층의 열 및 물질 전달 특성을 정확히 아는 것이 중요하다. 본 연구에서는 $Na_2$S-$H_2O$ 반응계를 사용한 화학 열펌프에 대한 연구로, $Na_2$S-팽창흑연 복합체의 열전도도와 기체 투과도를 측정하였고, 소형 시스템을 제작하여 그 성능을 평가하였다. 열전도도는 전이 일차원 열류기법을 사용하여 측정하였고, 기체 투과도는 Darcy's law를 이용하여 측정하였다. 반응층의 열전도도와 기체 투과도는 팽창흑연 지지체의 겉보기 밀도와 반응염의 함량에 따라 각각 6~48W/mㆍK, 1.1$\times$$10^{-13}$~1.0$\times$$10^{-11}$m$^2$의 범위에 있었다. 또한 소형 시스템을 구성하여 445W/kgㆍ$Na_2$S의 냉방 출력을 얻을 수 있었다.

  • PDF

A Study on the Thermal Behaviour of Via Design in the Ceramic Package (세라믹 패키지 내에서 비아에 따른 열적 거동에 관한 연구)

  • 이우성;고영우;유찬세;김경철;박종철
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.10 no.1
    • /
    • pp.39-43
    • /
    • 2003
  • Thermal management is very important for the success of high density circuit design in LTCC. In this paper, LTCC substrates containing thermal via and pad were fabricated in order to study the influence of the thermal dissipation. To realize the accurate thermal analysis for structure design, a series of simple thermal conductivity measurement by laser flash method and parametric numerical analysis have been carried out. The LTCC substrate including via and Ag pad has good thermal conductivity over 103 W/mK which is 44% value of pure Ag material. Thermal behaviors with via arrays, size and density in the LTCC substrate were studied by numerical method.

  • PDF

A Numerical Study On Thermal Characteristics of HALE UAV Solar Arrays (HALE 무인기의 태양전지 열특성에 관한 해석적 연구)

  • Song, Ji-Han;Nam, Yoonkwang
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.21 no.5
    • /
    • pp.29-36
    • /
    • 2017
  • In this study, a numerical analysis is made of the fluid flow and heat transfer characteristics in the solar arrays of HALE (High Altitude Lond Endurance) UAV. In the stratosphere where UAV operates, high level solar radiation is induced, heat transfer decreases due to natural convection and forced convection is dominated by ambient flow. In order to predict the solar array temperature range in this environment condition, the conjugate heat transfer analysis was carried out for the solar arrays on the main wing. The investigation focused on the temperature distribution of solar array and heat transfer characteristics according to influence of solar energy, flight condition as vehicle speed, air density, temperature.

Experimental Study of Thermo-electric material using Lithium-Ammonia$(Li(NH_3)_n)$ Solution (리튬-암모니아 $(Li(NH_3)_n)$ 용액을 이용한 열전기적 특성 실험)

  • Park, Han-Woo;Kim, Ji-Beom;Jeon, Joon-Hyeon
    • Korean Chemical Engineering Research
    • /
    • v.49 no.2
    • /
    • pp.263-270
    • /
    • 2011
  • The aim of this paper is, through the experiment of Lithium-Ammonia solutions $(Li(NH_3)_n)$, to analyze and verify a thermoelectric-conversion property at near Ammonia-boiling point ($-40^{\circ}C$). The experiment results show that the solutions with 0.58 MPM~1.87 MPM generate thermoelectric power at temperature difference $({\Delta}T=0{\sim}15^{\circ}C)$ where Current is constantly proportional to Voltage. This paper provides a new insight into the development of a thermoelectric material.

Heat Transfer on a Jet Vane Surface Installed in a Rocket Nozzle (로켓노즐에 장착된 제트베인 표면의 열전달 특성)

  • Yu Man Sun;Cho Hyung Hee;Hwang Ki Young;Bae Ju Chan
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.9 no.1
    • /
    • pp.9-16
    • /
    • 2005
  • Jet vane is an useful component which is installed at the end of a nozzle for the purpose of the posture control and the secure controlling stability during the initial launching of a rocket. During several seconds from its initial launching moment, the JV driving part is heated due to the direct contact of the vane with the combusted gas and the vane is ablated mechanically or chemically. In this study, as the fundamental study for the thermal analysis of jet vane, the heat transfer into a jet vane which is located in the uniform supersonic flow field is calculated. For this, boundary layer integral method and finite difference method are used simultaneously. Based on the thermal boundary conditions derived from the analysis, the transient heat conduction in the vane is also calculated.

Evaporation Heat Transfer Characteristics of Propane and Iso-butane in Micro-fin Tubes (마이크로핀관에서 프로판과 이소부탄의 증발 열전달 특성에 관한 연구)

  • Son, Chang-Hyo;Roh, Geon-Sang
    • Journal of the Korean Institute of Gas
    • /
    • v.11 no.4
    • /
    • pp.35-40
    • /
    • 2007
  • In this paper, evaporation heat transfer characteristics of propane and iso-butane in micro-fin tubes were investigated experimentally. Test section has a micro-fin tube with outside diameter of 12.70 mm, and 75 fins with a fin heights of 0.25 mm. The experimental results summarize as the followings: The average evaporation heat transfer coefficients of He's refrigerants is higher than those of HCFC22, and appeared in the order of iso-butane, propane with respect to the approaching of the high mass flux. The evaporation heat transfer coefficient of micro fin tube is about $10{\sim}80%$ higher than those of smooth tube. This results from the study can be used in the case of designing heat transfer exchanger using hydrocarbons as the refrigerant for the air-conditioning systems.

  • PDF