• Title/Summary/Keyword: 열전지

Search Result 494, Processing Time 0.023 seconds

A Study on the Properties of SM 400 for Evaluation of Structural Stability at High Temperature (고온 시의 구조내력 평가를 위한 SM 400강재의 고온 특성 평가 연구)

  • Kwon, In-Kyu
    • Fire Science and Engineering
    • /
    • v.27 no.4
    • /
    • pp.7-12
    • /
    • 2013
  • Recently, the risk of fire outbreak is going up because of newly developed combustible materials are intended to apply more. Especially the steel framed structure can lose its load-bearing capacity when it is exposed to higher temperature condition such as a fire. So the pre-evaluation of fire resistance of the structure is very essential that the mechanical properties of yield strength and elastic modulus and thermal properties such as conductivity and linear expansion be required. To get the databases for SM 400 or welding structural steels at high temperature, various temperature conditions were used for deriving the yield strength, elastic modulus, linear expansion, and conductivity and the results were compared to those of SS 400, ordinary structural steel, respectively.

Human Detection and Fuzzy Temperature Control System for Energy Reduction of Cooling Device in Elevator (승강기용 냉각장치의 에너지 절감을 위한 사람 검출과 퍼지 온도 제어 시스템)

  • Eum, Hyukmin;Jang, Sukyoon;Lee, Heejin;Park, Mignon;Yoon, Changyong
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.25 no.2
    • /
    • pp.147-154
    • /
    • 2015
  • In this paper, we propose human detection and fuzzy temperature control system for energy reduction of cooling device in elevator. In order to improve problems of existing cooling device using the refrigerant, energy reduction and efficient management are continuously achieved because of operation of thermoelectric cooling device using the human detection and fuzzy temperature control system. The proposed system confirms the number of passengers in elevator and temperature is then controlled by those numbers and an average temperature for the season in fuzzy system. The human detection method scans the number of passengers using a head part as a feature based on bird's-eye view camera in elevator. The fuzzy system determines elevator internal temperature considering atmospheric temperature and the scanned passenger numbers as a look-up table. The proposed system reduces energy of the cooling device through the human detection and temperature control. In experiment, energy reduction is confirmed and the performance of the proposed system is verified.

A Study on Cooling System for Efficiency Improvements of 3kW Outdoor Type Photovoltaic Inverter (3kW급 옥외형 태양광 인버터의 효율개선을 위한 냉각시스템 연구)

  • Kim, Min-Seok;Park, Eui-Jong;Kim, Yong-Jae;Oh, Bo-Seok
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.9 no.5
    • /
    • pp.617-624
    • /
    • 2014
  • Recently, photovoltaic inverter is received attention in photovoltaic with introduction of feed-in tariff. However, this inverter has problems such as inability to respond flexible at climate change due to its opening, and decrease of efficiency and lifetime due to its abnormal operation. To solve the problem, we desire to develop the eco-inverter which has a temperature control to respond easily on the change of temperature, and use the sealed structure not to affect the environment. In addition, we derive the optimal position of cooling system which is placed inside of inverter to minimize the power consumption, and proposed the effective measure to improve the efficient of inverter by deciding the number of cooling system.

Specific Heat and Thermal Conductivity Measurement of XLPE Insulator and Semiconducting Materials (XLPE 절연층과 반도전층 재료의 비열 및 열전도 측정)

  • Lee Kyoung-Yong;Yang Jong-Seok;Choi Yong-Sung;Park Dae-Hee
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.1
    • /
    • pp.6-10
    • /
    • 2006
  • To improve mean-life and reliability of power cable, we have investigated specific heat (Cp) and thermal conductivity of XLPE insulator and semiconducting materials in 154(kV) underground power transmission cable. Specimens were respectively made of sheet form with EVA, EEA and EBA added $30[wt\%],$ carbon black, and the other was made of sheet form by cutting XLPE insulator in 154(kV) power cable. Specific heat (Cp) and thermal conductivity were measured by DSC (Differential Scanning Calorimetry) and Nano Flash Diffusivity. Specific-heat measurement temperature ranges of XLPE insulator were from $20[^{\circ}C]\;to\;90[^{\circ}C],$ and the heating rate was $1[^{\circ}C/mon].$ And the measurement temperatures of thermal conductivity were $25[^{\circ}C],\;55[^{\circ}C]\;and\;90[^{\circ}C].$ In case of semiconducting materials, the measurement temperature ranges of specific heat were from $20[^{\circ}C]\;to\;60[^{\circ}C],$ and the heating rate was $1[^{\circ}C/mon].$ And the measurement temperatures of thermal conductivity were $25[^{\circ}C],\;55[^{\circ}C].$ In addition we measured matrix of semiconducting materials to show formation and growth of carbon black in base resins through the SEM. From these experimental results, both specific heat and thermal conductivity were increased by heating rate because volume of materials was expanded according to rise in temperature.

Thermal Characteristics of 20 W LED Module on Light Thermal Conductive Plastic Heat Sink: Comparison with that on Aluminum Die Casting Alloy (ADC-12) (경량화 열전도성 플라스틱 Heat Sink기반 20 W급 LED Module의 열 특성: 다이캐스팅합금 (ADC-12)과 비교 연구)

  • Yeo, Jung-Kyu;Her, In-Sung;Lee, Seung-Min;Choi, Hee-Lack;Yu, Young-Moon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.6
    • /
    • pp.380-385
    • /
    • 2016
  • Thermal characteristics of 20 W LED module on light thermal conductive plastic (TCP) heat sink were investigated in comparison with that on aluminum die casting alloy (ADC-12). Thermal simulations of the heat sinks were conducted by using flow simulation of SolidWorks with the following input parameters: density is 1.70 and $2.82kg/m^2$, thermal conductivity is 20 and $92W/(m{\cdot}K)$ for TCP and ADC-12, respectively. The simulated and measured temperatures of the LED modules on TCP heat sink were consistent with its measured temperature, which was $3^{\circ}C$ higher that on ADC-12. The fabricated LED module on TCP heat sink with a weight of 120.5 g was 30% lighter in weight than that of the ADC-12 reference with 171.0 g.

Characteristics of ionic Wind in a DC Corona Discharge in Needle-to-punched plate Geometry (침 대 중공평판전극에서 직류코로나 방전에 의한 이온풍 특성)

  • Lee, Bok-Hee;Kil, Hyeong-Joon;Eom, Ju-Hong;Ahn, Chang-Hwan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.4
    • /
    • pp.74-80
    • /
    • 2003
  • Ionic wind is produced by a corona discharge when a DC high voltage is applied across the point-to-plane gap geometry. The corona discharge phenomena have been investigated in several beneficial application fields such as electrostatic cooling, ozone generation, electrostatic precipitation and electrostatic spraying. Recently ionic wind might be used in aerodynamic, for example, heat transfer, airflow modification, and etc. In this work, in order to analyze the control behavior of the velocity and amount of ionic wind produced by the positive DC corona discharges. The ionic wind velocity was measured as a function of the applied voltage, diameter of the punched hole on plate electrode and separation between the point-to-plate electrodes. As a results, the airflow is generated from the tip of needle to the plate electrode in the needle-to-punched-plate electrode systems. The ionic wind velocity is linearly increased with an increase in applied voltage and ranges from 1 to 3 m/sec at the locations of 100-200 mm from the punched-plate.

The Characteristics Analysis of Novel Moat Structures in Shallow Trench Isolation for VLSI (초고집적용 새로운 회자 구조의 얕은 트랜치 격리의 특성 분석)

  • Lee, Yong-Jae
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.10
    • /
    • pp.2509-2515
    • /
    • 2014
  • In this paper, the conventional vertical structure for VLSI circuits CMOS intend to improve the stress effects of active region and built-in threshold voltage. For these improvement, the proposed structure is shallow trench isolation of moat shape. We want to analysis the electron concentration distribution, gate bias vs energy band, thermal stress and dielectric enhanced field of thermal damage between vertical structure and proposed moat shape. Physically based models are the ambient and stress bias conditions of TCAD tool. As an analysis results, shallow trench structure were intended to be electric functions of passive as device dimensions shrink, the electrical characteristics influence of proposed STI structures on the transistor applications become stronger the potential difference electric field and saturation threshold voltage, are decreased the stress effects of active region. The fabricated device of based on analysis results data were the almost same characteristics of simulation results data.

Visualization of Flow Characteristics on Thermosyphon with Immiscible Binary Working Fluid (비 혼합 2유체 열사이폰의 유동 특성에 관한 가시적 연구)

  • Do, Sun Yub;Kang, Hawn Kook;Park, Seung Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.5
    • /
    • pp.3022-3029
    • /
    • 2015
  • This study presents experiments to visualize the internal flow and heat transfer characteristics of thermosyphon with immiscible of water-FC40 adopted as binary working fluid. Three different regimes depending on the amount of heat flux applied to the thermosyphon were observed: natural convection, pulse boiling, and continuous boiling. Boiling incipience took place in water, which has lower vapor pressure than FC40. During natural convection water was vaporized in liquid pool while liquid film flows were formed. On the other hand, meanwhile bubbles were generated in the liquid pool during pulse and continuous boiling, the binary working fluid of water-FC40 was observed as the mixture throughout a whole range of the thermosyphon.

Numerical Analysis on the Effect of Corrugation Angle on the Performance of Humidifying Element (절곡각에 따른 가습소자의 성능에 대한 수치해석적 연구)

  • Lee, Eul-Jong;Kim, Nae-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.5
    • /
    • pp.3051-3059
    • /
    • 2015
  • In this study, the effect of corrugation angle on thermal performance of corrugated plate is numerically investigated with an aim to develop humidifying element. Numerical analysis was conducted for a range of corrugation angle (from $0^{\circ}/0^{\circ}$ to $60^{\circ}/60^{\circ}$ for equal angle and from $15^{\circ}/0^{\circ}$ to $15^{\circ}/60^{\circ}$ for unequal angle). Results revealed that both j and f factor increased as corrugation angle increased. Especially, f factor increased significantly at high corrugation angles. j and f factors of unequal angle plates and those of equal angle (obtained by averaging unequal angles) plates were approximately the same. The largest $j/f^{1/3}$, which implies the largest heat transfer rate per consumed power, was obtained at $15^{\circ}/15^{\circ}$. Existing correlations under- or over-predicted the present numerical results.

Air-Side Performance of Fin-and-Tube Heat Exchangers Having Non-Symmetric Slit Fins Under Wet Condition (비대칭형 슬릿 핀이 적용된 핀-관 열교환기의 습표면 성능)

  • Kim, Nea-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.6
    • /
    • pp.3698-3707
    • /
    • 2015
  • In this study, wet surface heat transfer and friction characteristics of non-symmetric slit-finned heat exchangers are experimentally investigated. Louver-finned heat exchangers are also tested for comparison purpose. The effect of fin pitch on j and f factor is negligible. Louver fin samples yield higher j and f factors than slit fin samples. For one row, j and f factors of louver fin are 27% and 31% higher than those of slit fin. For two row, j and f factors of louver fin are 15% and 30% higher. Both j and f factor decrease as the number of tube row increases. For one row, average j/f ratios of slit fin samples are 3.4% larger than those of louver fin samples. For two row, average j/f ratios of slit fin samples are 11.5% larger. A new correlation was developed using the present data.