• Title/Summary/Keyword: 열전달 감소

Search Result 305, Processing Time 0.033 seconds

Estimation of Soil Cooling Load in the Root Zone of Greenhouses (온실내 근권부의 지중냉각부하 추정)

  • 남상운
    • Journal of Bio-Environment Control
    • /
    • v.11 no.4
    • /
    • pp.151-156
    • /
    • 2002
  • Root zone cooling, such as soil or nutrient solution cooling, is less expensive than air cooling in the whole greenhouse and is effective in promoting root activity, improving water absorption rate, decreasing plant temperature, and reducing high temperature stress. The heat transfer of a soil cooling system in a plastic greenhouse was analyzed to estimate cooling loads. The thermal conductivity of soil, calculated by measured heat fluxes in the soil, showed the positive correlation with the soil water content. It ranged from 0.83 to 0.96 W.m$^{[-10]}$ .$^{\circ}C$$^{[-10]}$ at 19 to 36% of soil water contents. As the indoor solar radiation increased, the temperature difference between soil surface and indoor air linearly increased. At 300 to 800 W.m$^{-2}$ of indoor solar radiations, the soil surface temperature rose from 3.5 to 7.$0^{\circ}C$ in bare ground and 1.0 to 2.5$^{\circ}C$ under the canopy. Cooling loads in the root zone soil were estimated with solar radiation, soil water content, and temperature difference between air and soil. At 300 to 600 W.m$^{-2}$ of indoor solar radiations and 20 to 40% of soil water contents,46 to 59 W.m$^{-2}$ of soil cooling loads are required to maintain the temperature difference of 1$0^{\circ}C$ between indoor air and root zone soil.

Evaluation of compensator to reduce thermal sensation in oncological hyperthermia (고주파 온열암 치료 시 열감감소를 위해 자체 제작한 보상체의 유효성 평가)

  • Lee, Yeong Cheol;Kim, Sun Myung;Jeong, Deok Yang;Kim, Young Bum
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.2
    • /
    • pp.27-32
    • /
    • 2017
  • Objectives: Oncological hyperthermia is a treatment to selectively kill cancer cells by directly applying heat to cancer cells or indirectly demage cancer cells. One of the most side effects of treatment is burn that can appear on the skin. In areas with irregularities such as the umbilicus, the patient feels a sense of hot and treatment may be discontinued. Therefore, in order to eliminate the irregularities of these areas, compensators are manufactured and measured to decrease in temperature. Materials and Methods: The temperature of the four sites (umbilicus, near the umbilicus, 5 cm below the umbilicus, back) was measured five times around the umbilicus in patients who were treated at oncological hyperthermia treatment device(EHY-2000, Oncotherm Kft, Hungary). The temperature sensor (TM-100, Oncotherm Kft, Hungary) was attached to four sites and the changes were observed at 5, 15, 25, 35, and 50 minutes after treatment. Compensators of three materials were used(Vaseline, Bolus, Dental resin). The data measured five times were compared for each compensator. Results: The temperature change when the compensator was not used increase from 34.65 degrees to 42.9 degrees on average. The near umbilicus was changed from 32.20 degrees to 37.00 degrees, and the 5 cm below the umbilicus was changed from 31.90 to 34.41 degrees. When the compensator material was inserted into the umbilicus, the temperature change was measured as 5.42 degrees for bolus, 6.55 degrees for vaseline, and 6.83 degrees for resin. Conclusion: Using the compensator in the region where the irregularities such as the umbilicus, the heat sensation could be reduced. the use of a resin that can be customized not only lowers the temperature but also significantly reduces the feeling of the patient. It will be possible to reduce the heat sensation in the treatment and to treat it in a more comfortable condition.

  • PDF

Inhibition of Microbial Growth in Cabbage-Kimchi by Heat Treatment and Nisin·Yucca Extract (열처리 및 나이신·유카추출물 첨가에 의한 김치의 미생물 증식 저해)

  • Kim, Ji-Sun;Kim, Yu-Jin;Park, Jung-Mi;Kim, Tae-Jip;Kim, Beom-Soo;Kim, Yeon-Mi;Kim, Hye-Rim;Han, Nam-Soo
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.39 no.11
    • /
    • pp.1678-1683
    • /
    • 2010
  • For extension of storage period of cabbage-kimchi, effects of heat treatment as well as nisin or yucca extract were examined on the growth of microbes. Firstly, when kimchi was heated at various temperatures in polyethylene plastic bottle or membrane pouch, the optimum inhibitory condition giving no sensory change was at $80^{\circ}C$ for 30 min in a plastic membrane pouch and this treatment made a reduction of $0.3\;log_{10}CFU/g$ in total microbes. The result showed that use of plastic bottle was inefficient due to low heat transfer rate. Interestingly, pasteurization of seasoning pastes at $80^{\circ}C$ for 30 min separately from cabbage resulted in better inhibitory effect reducing $0.5\;log_{10}CFU/g$ of total bacteria and $1.0\;log_{10}CFU/g$ of lactic acid bacteria, and this operation was regarded as a promising inhibitory method. Secondly, when nisin and yucca extract were separately added in kimchi, microbial growth was inhibited during storage period and their inhibition effects were enhanced at lower temperature.

Comparison Of CATHARE2 And RELAP5/MOD3 Predictions On The BETHSY 6.2% TC Small-Break Loss-Of-Coolant Experiment (CATHARE2와 RELAP5/MOD3를 이용한 BETHSY 6.2 TC 소형 냉각재상실사고 실험결과의 해석)

  • Chung, Young-Jong;Jeong, Jae-Jun;Chang, Won-Pyo;Kim, Dong-Su
    • Nuclear Engineering and Technology
    • /
    • v.26 no.1
    • /
    • pp.126-139
    • /
    • 1994
  • Best-estimate thermal-hydraulic codes, CATHARE2 V1.2 and RELAP5/MOD3, hate been assessed against the BETHSY 6.2 tc six-inch cold leg break loss-of-coolant accident (LOCA) test. Main objective is to analyze the overall capabilities of the two codes on physical phenomena of concern during the small break LOCA i.e. two-phase critical flow, depressurization, core water level de-pression, loop seal clearing, liquid holdup, etc. The calculation results show that the too codes predict well both in the occurrences and trends of major two-phase flow phenomena observed. Especially, the CATHARE2 calculations show better agreements with the experimental data. However, the two codes, in common, show some deviations in the predictions of loop seal clearing, collapsed core water level after the loop seal clearing, and accumulator injection behaviors. The discrepancies found from the comprision with the experimental data are larger in the RELAP5 results than in the CATHARE2. To analyze the deviations of the two code predictions in detail, several sensitivity calculations have been performed. In addition to the change of two-phase discharge coefficients for the break junction, fine nodalization and some corrections of the interphase drag term are made. For CATHARE2, the change of interphase drag force improves the mass distribution in the primary side. And the prediction of SG pressure is improved by the modification of boundary conditions. For RELAP5, any single input change doesn't improve the whole result and it is found that the interphase drag model has still large uncertainties.

  • PDF

Evaluation for Mechanical Properties of High Strength Concrete at High Temperature by Stressed Test and Unstressed Test (설계하중 사전재하 및 비재하방식에 의한 고강도콘크리트의 고온특성 평가)

  • Kim, Gyu-Yong;Kim, Young-Sun;Lee, Tae-Gyu;Park, Chan-Kyu;Lee, Seung-Hoon
    • Journal of the Korea Concrete Institute
    • /
    • v.20 no.5
    • /
    • pp.583-592
    • /
    • 2008
  • Recently, the effects of high temperature on compressive strength, elastic modulus and strain at peak stress of high strength concrete were experimentally investigated. The present study is aimed to study the effect of elevated temperatures ranging from 20 to 700 on the material mechanical properties of high strength concrete of 40, 60, 80 MPa grade. In this study, the types of test were the stressed test and stressed residual test that the specimens are subjected to a 25% of ultimate compressive strength at room temperature and sustained during heating and when target temperature is reached, the specimens are loaded to failure. And another specimens are loaded to failure after 24 hour cooling time. Tests were conducted at various temperatures ($20{\sim}700^{\circ}C$) for concretes made with W/B ratios 46%, 32% and 25%. Test results showed that the relative values of compressive strength and elastic modulus decreased with increasing compressive strength grade of specimen and the axial strain at peak stress were influenced by the load before heating. Thermal strain of concrete at high temperature was affected by the preload level as well as the compressive strength. Finally, model equation for compressive strength and elastic modulus of heated high strength concrete proposed by result of this study.

Analysis on Heat Loss of Single-span Greenhouse Using Small-scaled Wind Tunnel (소형풍동을 이용한 단동 비닐온실의 열손실 분석)

  • Kim, Young Hwa;Kim, Hyung kow;Lee, Tae suk;Oh, Sung sik;Ryou, Young sun
    • Journal of Bio-Environment Control
    • /
    • v.29 no.1
    • /
    • pp.73-79
    • /
    • 2020
  • The objective of this study is to analyze the heat transfer loss of covering materials in a single-span plastic greenhouse under the steady-state wind environment. To achieve this objective, the following were conducted: (1) design of a small-scaled wind tunnel (SCWT) to analyze heat losses of the greenhouse and its performance; (2) determination of the overall heat transfer coefficient (OHTC) for the covering materials using a small-scaled greenhouse model. The SCWT consists of the blowing, dispersion, steady flow, reduction and testing areas. Each part of the SCWT was customized and designed to maintain air flow at steady state and to minimize the variances in the SCWT test. In this study, the OHTCs of the covering materials were calculated by separating each with the roof, side wall, front and back of the small-scaled greenhouse model. The results of this study show that the OHTC of the roof increases as wind speed increases but the zones in which the increase rate of the OHTC decreased, were distinguished by wind tunnel wing speed of 2 ms-1. For the side wall, the increase rate of the OHTC was particularly higher in the 0-1 ms-1 zone.

Numerical Study on the Cooling Characteristics of a Passive-Type PEMFC Stack (수동공기공급형 고분자 전해질 연료전지 스택에서의 냉각특성에 대한 전산해석 연구)

  • Lee, Jae-Hyuk;Kim, Bo-Sung;Lee, Yong-Taek;Kim, Yong-Chan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.8
    • /
    • pp.767-774
    • /
    • 2010
  • In a passive-type PEMFC stack, axial fans operate to supply both oxidant and coolant to cathode side of the stack. It is possible to make a simple system because the passive-type PEMFC stack does not require additional cooling equipment. However, the performance of a cooling system in which water is used as a coolant is better than that of the air-cooling system. To ensure system reliability, it is essential to make cooling system effective by adopting an optimal stack design. In this study, a numerical investigation has been carried out to identify an optimum cooling strategy. Various channel configurations were applied to the test section. The passive-type PEMFC was tested by varying airflow rate distribution at the cathode side and external heat transfer coefficient of the stack. The best cooling performance was achieved when a channel with thick ribs was used, and the overheating at the center of the stack was reduced when a case in which airflow was concentrated at the middle of the stack was used.

Nonlinear Thermo-mechanical Analysis Considering Heat Flow under Fire Conditions (화재 열 유동을 고려한 구조물의 열응력해석)

  • Pak, Hongrak;Kang, Jun Won;Lee, Jinwoo
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.29 no.4
    • /
    • pp.369-376
    • /
    • 2016
  • In this study, a numerical analysis framework for investigating the nonlinear behavior of structures under fire conditions is presented. In particular, analysis procedure combining fire-driven flow simulation and thermo-mechanical analysis is discussed to investigate the mechanical behavior of fire-exposed representative volume structures made of steel and concrete, respectively. First of all, fire-driven flow analysis is conducted using Fire Dynamics Simulator(FDS) in a rectangular parallelepiped domain containing the structure. The FDS simulation yields the time history of temperature on the surface of the structure under fire conditions. Second, mechanical responses of the fire-exposed structure with respect to prescribed uniformly distributed loads are calculated by a coupled thermo-mechanical analysis using the time-varying surface temperature as boundary conditions. Material nonlinearities of steel and concrete have been considered in the thermo-mechanical analysis. A series of numerical results are presented to demonstrate the feasibility of the multiphysics structural fire analysis for investigating the structural behavior under fire conditions.

Microwave Vacuum Drying of Germinated Colored Rice as an Enzymic Health Food (효소식품으로서 발아유색미의 마이크로파 진공건조)

  • Kim, Suk-Shin;Kim, Sang-Yong;Noh, Bong-Soo;Chang, Kyu-Seob
    • Korean Journal of Food Science and Technology
    • /
    • v.31 no.3
    • /
    • pp.619-624
    • /
    • 1999
  • This work was to study the potential health food use of germinated colored rice after germinating and drying using microwave under vacuum. Colored rice was soaked in water at $15^{\circ}C$ for 2 days and then germinated at $25^{\circ}C$ for $3{\sim}4\;days$. The germinated colored rice was dried by different drying methods: microwave vacuum drying 1, microwave vacuum drying $2\;(drying{\rightarrow}crushing{\rightarrow}drying)$, hot air drying, vacuum drying and freeze drying. Each drier except freeze drier was set to maintain the sample temperature at $60^{\circ}C$. During microwave vacuum drying 1 or 2, the sample reached $60^{\circ}C$ much faster (within 5 min) and was dried much faster ($2{\sim}3\;hrs$ than the other drying methods. The initial drying rate of microwave vacuum drying was ten times faster than that of hot air drying. The microwave vacuum drying 2 retained the highest ${\alpha}-amylase$ activity, followed by microwave vacuum drying 1, freeze drying, vacuum drying, and hot air drying.

  • PDF

Design of a pilot-scale helium heating system to support the SI cycle (파이롯 규모 SI 공정 시험 설비에서의 헬륨 가열 장치 설계)

  • Jang, Se-Hyun;Choi, Yong-Suk;Lee, Ki-Young;Shin, Young-Joon;Lee, Tae-Hoon;Kim, Jong-Ho;Yoon, Seok-Hun;Choi, Jae-Hyuk
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.3
    • /
    • pp.157-164
    • /
    • 2016
  • In this study, researchers performed preliminary design and numerical analysis for a pilot-scale helium heating system intended to support full-scale construction for a sulfur-iodine (SI) cycle. The helium heat exchanger used a liquefied petroleum gas (LPG) combustor. Exhaust gas velocity at the heat exchanger outlet was approximately 40 m/s based on computational thermal and flow analysis. The maximum gas temperature was reached with six baffles in the design; lower gas temperatures were observed with four baffles. The amount of heat transfer was also higher with six baffles. Installation of additional baffles may reduce fuel costs because of the reduced LPG exhausted to the heat exchanger. However, additional baffles may also increase the pressure difference between the exchanger's inlet and outlet. Therefore, it is important to find the optimum number of baffles. Structural analysis, followed by thermal and flow analysis, indicated a 3.86 mm thermal expansion at the middle of the shell and tube type heat exchanger when both ends were supported. Structural analysis conditions included a helium flow rate of 3.729 mol/s and a helium outlet temperature of $910^{\circ}C$. An exhaust gas temperature of $1300^{\circ}C$ and an exhaust gas rate of 52 g/s were confirmed to achieve the helium outlet temperature of $910^{\circ}C$ with an exchanger inlet temperature of $135^{\circ}C$ in an LPG-fueled helium heating system.