• Title/Summary/Keyword: 열전냉각

Search Result 699, Processing Time 0.026 seconds

An Experimental Study on the Effects of the Cooling Jacket Design Parameters on the Performance of Thermoelectric Cooling System (열전소자 냉각 자켓의 설계인자가 열전냉각 시스템의 성능에 미치는 효과에 대한 실험적 연구)

  • Lee, J.E.;Park, S.H.;Kim, K.;Kim, D.
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2079-2084
    • /
    • 2007
  • A small-scale thermoelectric cooling system was built in an effort to enhance the performance of the refrigeration system by utilizing the water-cooled jacket which was attached on the hot side of the thermoelectric module. Considered design parameters for the water-cooled jacket included the geometry of the flow passage inside the jacket and the flow rate of cooling water. The higher flow rate of cooling water in the jacket resulted in a better performance of the refrigeration system. The introduction of geometrical complexity of the cooling water flow passage to the cooling jacket also showed significant improvement on the performance of the thermoelectric refrigeration system such as the cooling capacity and the COP of the refrigeration system.

  • PDF

A Study on the Hot Spot Cooling Using Thermoelectric Cooler (열전냉각 모듈을 이용한 국소 냉각에 관한 연구)

  • Kim, Ook-Joong;Lee, Kong-Hoon
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.640-645
    • /
    • 2007
  • An experimental apparatus to show the hot spot cooling of an IC chip using a thermoelectric cooler is developed. The spot heating in very small area is achieved by the applying CO$_2$ laser source and temperatures are measured using miniature thermocouples. The active effects of thermoelectric cooler on the hot spot cooling system such as rapid heat spreading in the chip and lowering the peak temperature around the hot spot region are investigated. The experimental results are simulated numerically using the TAS program, which the performance characteristics such as Seebeck coefficient, electrical resistance and thermal conductivity of the thermoelectric cooler are searched by trial and error. Good agreements are obtained between numerical and experimental results if the appropriate performance data of the thermoelectric cooler are given.

  • PDF

Experimental Study on Kerosene Heat Transfer Characteristics Using Simulating Cooling Channels (모사 냉각채널을 이용한 케로신 열전달 특성에 대한 실험적 연구)

  • Lee, Bom;Lee, Wongoo;Song, Yoonho;Hwang, Donghyun;Ahn, Kyubok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.643-646
    • /
    • 2017
  • In a liquid rocket engine using hydrocarbon fuels, cooling of the combustion chamber wall is necessary to prevent the combustion chamber wall from melting or structurally deforming due to high heat flux. Among the various methods, regenerative cooling, which uses fuel as a coolant and then injects it into the combustion process, has good performance. This study investigated the heat transfer characteristics of kerosene as a coolant by varying the copper cross-sectional area, the flow rate in the channel, and the current applied to the channel. Convective heat transfer occurred rapidly when the cross-sectional area of the copper channel was small and when the kerosene flow velocity was fast.

  • PDF

Experimental Study on Heat Transfer Characteristics of Jet A-1 Fuel (Jet A-1 연료의 열전달 특성에 관한 실험적 연구)

  • Lee, Junseo;Lee, Bom;Ahn, Kyubok
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.24 no.5
    • /
    • pp.1-12
    • /
    • 2020
  • In this paper, the heat transfer characteristics of Jet A-1, which is used as a coolant and fuel in a regeneratively cooled thrust chamber, were experimentally studied. By varying the applied current for heating the cooling channel, the simulated specimen diameter, the specimen outlet pressure and the coolant flow rate, the wall temperatures of the specimen and the Jet A-1 temperatures at the specimen inlet/outlet were measured. It was found that the specimen diameter and the flow rate were important factors for the characteristics of heat transfer and the outlet pressure did not affect the performance of heat transfer. The results of the heat transfer experiments were compared with the previous Nusselt number empirical equations and novel Nusselt number empirical equations were finally derived.

Heat Transfer on Slot Film Cooling for Convergent Nozzle (축소노즐내 슬롯 막냉각에서의 열전달 특성)

  • 조용일;유만선;정학재;조형희
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.5 no.1
    • /
    • pp.34-41
    • /
    • 2001
  • A study has been conducted to observe the slot film cooling effect on a convergent nozzle wall. The slot film cooling is used to protect the nozzle wall from the hot combusted gas by the coolant injected from the slot around the inner wall of the nozzle. The film cooling effectiveness and the heat transfer to the nozzle wall are influenced significantly by the blowing ratio of the coolant to the main flow and those are also influenced by the shape of the slot and the flow acceleration in the nozzle. In the present study, the heat transfer for the various blowing ratios has been performed by the experimental method and the results are compared with the results computed by the empirical formula. The numerical method has been conducted to compare the film cooling effectiveness of the convergent nozzle with that of the cylinder. For the relatively low blowing ratio, the cooling effectiveness increases sharply as the blowing ratio increases, and the increasing rate slows down for the high blowing ratio.

  • PDF

Heat Transfer Characteristics of Supercritical $CO_2$ in Helical Coil Gas Coolers on the Change of Coil Diameters (코일직경변화에 따른 헬리컬 코일형 가스냉각기내 초임계 이산화탄소의 냉각열전달 특성)

  • Son, Chang-Hyo
    • Journal of the Korean Institute of Gas
    • /
    • v.11 no.3
    • /
    • pp.44-48
    • /
    • 2007
  • The cooling heat transfer characteristics of supercritical $CO_2$ in a helical coil gas cooler on the change of coil diameters are experimentally investigated. The main components of the refrigerant loop are a receiver, a variable speed pump, a mass flow-meter, a pre-heater and a helical coil gas cooler (test section). The test sections are made of a copper tube which the inner diameter is 4.55 mm and the helical coil diameters are done of 26.75 mm and 41.35 mm. The mass fluxes of refrigerant are varied from 200 to 800 [$kg/m^2s$] and the inlet pressures of gas cooler are 7.5 to 10.0 (MPa). A gas cooler with helical coil diameter of 26.75 mm has larger heat transfer coefficient than that of 41.35 mm. Also, when compared with experimental data and published correlations avaliable, most of correlations are under-predicted, but Pitla published correlations avaliable, most of correlations are under-predicted, but Pitla et al.'s correlation shows a relatively good coincidence with the experimental data except the region of pseudo critical temperature.

  • PDF

Heat Transfer Enhancement of Water Spray Cooling by the Surface Roughness Effect (표면거칠기 효과에 따른 스프레이 냉각의 열전달 향상 연구)

  • Lee, Jung-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.2
    • /
    • pp.203-212
    • /
    • 2010
  • Water spray cooling has been widely used in a variety of industrial applications. The present study concentrated on quantitative measurements of the heat flux and heat transfer coefficient by water spray as it impinges on the rough surface of a hot steel plate at $900^{\circ}C$. A novel experimental technique was developed for a hightemperature heat flux gauge with a test block, cartridge heaters, and thermocouples that was used to measure the surface heat flux information on the hot steel plate for local heat flux measurements. The roles of the surface roughness on heat transfer are presented in this paper for well-characterized four rough surfaces with average rms roughness heights of $40-80{\mu}M$. The results show that the local heat transfer for rough surfaces is higher than that for a smooth surface. Heat transfer can be significantly increased by the presence of surface roughness elements, which can disrupt the thin thermal boundary layer. In addition, the heat transfer enhancement mechanism on a rough surface can be investigated by a different boiling regime.

Thermoelectric Peltier Module Applications of Cold/Hot Cup-holder (열전소자의 냉온컵홀더 응용기술)

  • Soh, Dea-Wha
    • Journal of the Speleological Society of Korea
    • /
    • no.75
    • /
    • pp.65-71
    • /
    • 2006
  • 팰티어-열전소자를 응용한 냉온컵홀더를 구성하는 응용기술을 제안하였다. 열전소자의 용량에 제한을 받기 때문에 가열 또는 냉각을 위해서는 충분한 용량을 뒷받침 해 줘야 한다. 따라서 컵홀더와 같은 휴대 필요성이 요구되거나 휴대 가능한 소형기기의 경우에는 온열 또는 냉각 상태를 유지시키는 보온기능을 갖는 온열기기로써의 적합성을 확인하였다.

Research for Actively Reducing Infrared Radiation by Thermoelectric Refrigerator (열전소자를 이용한 적외선 방사량 감소 기술에 관한 연구)

  • Kim, Hoon;Kim, Kyomin;Kim, Woochul
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.41 no.3
    • /
    • pp.199-204
    • /
    • 2017
  • We introduced a technology for reducing infrared radiation through the active cooling of hot surfaces by using a thermoelectric refrigerator. Certain surfaces were heated by aerodynamic heating, and the heat generation processes are proposed here. We calculated the temperatures and radiations from surfaces, while using thermoelectric refrigerators to cool the surfaces. The results showed that the contrast between the radiations of certain surfaces and the ambient environments can be removed using thermoelectric refrigerators.

Experimental Investigation on Forced Convective Heat Transfer Characteristic Generated to Heated Tube (가열된 튜브에서 발생하는 강제 대류열전달 특성에 관한 실험적 연구)

  • Park, Hee-Ho;Lee, Yang-Suk;Kim, Sun-Jin
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.10 no.3
    • /
    • pp.90-98
    • /
    • 2006
  • The Heated Tube Facility(HIF) was fabricated to identify the forced convective heat transfer and the cooling characteristic for the hydrocarbon fuel(Jet A-1), which is used for the coolant of the regenerative cooling system. The forced convective heat transfer coefficient was calculated from the measured coolant and tube surface temperature. In case of using the Jet A-1, the maximum heat flux which the coolant can absorb was identified by determining the critical wall temperature generating the burnout on the fixed flow condition. The inlet bulk-temperature of the coolant has a direct influence on the forced convective heat transfer characteristic.