• Title/Summary/Keyword: 열적설계

Search Result 377, Processing Time 0.023 seconds

Design Verification of Thermal Control Subsystem for EOS-C Ver.3.0 using STM Thermal Vacuum Test Result (STM 열진공 시험 결과를 이용한 EOS-C Ver.3.0 열제어계 설계 검증)

  • Chang, Jin-Soo;Yang, Seung-Uk;Jeong, Yun-Hwang
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.38 no.12
    • /
    • pp.1232-1239
    • /
    • 2010
  • A high-resolution electro-optical camera (EOS-C Ver.3.0), the mission payload of an Earth observation satellite, is under development in Satrec Initiative. We designed this system to give improved thermal performance compared with the EOS-C Ver.2.0 which is the main payload of DubaiSat-1 by optimizing the active and passive thermal control design. We developed the Structural-Thermal Model (STM) and verified the design margin by performing the qualification level thermal vacuum test. We also conducted the verification of its Thermal Mathematical Model (TMM) through the thermal balance test. As a result, it was confirmed that TMM faithfully represents the thermal characteristics of the EOS-C Ver.3.0.

Structural Design of a Mover considering the Thermal Analysis of a Stator Module (스테이터 모듈의 열해석을 고려한 이동체의 구조설계)

  • Lee, Jeong-Myeong;Han, Dong-Seop;Lee, Seong-Uk;Han, Geun-Jo;Lee, Gwon-Sun
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • v.1
    • /
    • pp.367-372
    • /
    • 2006
  • When we design a linear motor, the thermal behavior investigation is one of great important considerations with respect to uniform thrust force and thermal deformation of a linear motor. In this study, we conduct the research for the structural design of the linear motor for LMTT(Linear Motor-based Transfer Technology) which is the next generation of container horizontal transfer system in order to automate a container terminal. After the dimensions of main parts for a linear motor were set up, we carried out the thermal-structural analysis of the linear motor considering the thermal analysis of the stator module.

  • PDF

Thermal Performance of the Show-Case Cooler Using Ice Slurry Type Storage System (아이스슬러리형 축냉시스템을 이용한 쇼케이스 냉각장치의 열적성능에 관한 실험적 연구)

  • Lee, Dong-Won;Kim, Jeong-Bae
    • Journal of Energy Engineering
    • /
    • v.20 no.1
    • /
    • pp.26-29
    • /
    • 2011
  • A promising alternative technology is the potential use of ice slurries as a secondary refrigerant in conventional cooling process. Ice slurries behave almost like a liquid and can be pumped through pipes although the energy capacity of ice slurries per unit volume is considerably higher than that for chilled water or brine due to the latent heat capacity of the ice particles. To give the basic data for the design of cooling systems using ice slurries, experimental study has been conducted to find out the performance of the cooling coil of show-case with ice slurries. Despite the fact that ice slurries entering the cooling coil had at least $5^{\circ}C$ higher temperature than that of R22, it was still capable of providing a similar cooling performance than that obtained with R22.

An Investigation of Fluid Mixing with Direct Vessel Injection (직접용기주입에 따른 유체혼합에 관한 연구)

  • Cha, Jong-Hee;Jun, Hyung-Gil
    • Nuclear Engineering and Technology
    • /
    • v.26 no.1
    • /
    • pp.63-77
    • /
    • 1994
  • The objective of this work is to investigate fluid mixing phenomena related to pressurized thermal shock(PTS) in a pressurized water reactor(PWR) vessel downcomer during transient cooldown with direct vessel injection(DVI) using test models. The test model designs were based on ABB Combustion Engineering(C-E) System 80+ reactor geometry. A cold leg small break loss-of-coolant accident(LOCA) md a main steam line teak were selected as the potential PTS events for the C-E System 80+. This work consist of two parts. The first part provides the visualization tests of the fluid mixing between DVI fluid and existing coolant in the downcomer region, and the second part is to compare the results of thermal mixing tests with DVI in the other test model. Row visualization tests with DVI have clarified the physical interaction between DVI fluid and primary coolant during transient cooldown. A significant temperature drop was observed in the downcomer during the tests of a small break LOCA Measured transient temperature profiles agree well with the predictions by the REMIX code for a small break LOCA and with the calculations by the COMMIX-1B code for a steam line break event.

  • PDF

Thermal Performance of PV Cells Exposed to Irradiation by a Parabolic Trough Concentrator (PTC형 태양열 집열기로 조사되는 PV cell의 열적 성능)

  • Hwang, Seon Yeob;Kang, Tae Gon;Boo, Joon Hong
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.68-68
    • /
    • 2011
  • 본 연구에서는 PV cell이 직달 일사에 노출되는 경우와 집광된 태양광에 조사되는 경우의 성능을 비교하는 한편 집광기의 형태에 따른 열적 성능을 검토하고자 하였다. PV cell은 본질적으로 반도체의 특성을 가지므로 작동온도의 상승에 따라 성능이 저하된다는 사실이 알려져 있으며, 태양조사의 강도 및 밀도 등 특성에 따라서도 성능의 변화를 예상할 수 있다. 그러나 이러한 성능변화에 관련된 인자들과 그 영향의 크기에 대한 정량적인 기술자료가 부족하므로 설치와 이용에 한계가 있는 것이 현실이다. 인공태양 장치(solar simulator)를 이용하여 0.7에서 1.2 sun 범위의 태양 조사 환경에서 결정질 실리콘계 PV cell과 집광형 PV cell의 성능을 검토하였다. 집광에 사용한 PTC는 집광면적의 폭이 500 mm이며, 집광 조사면적이 최소 10 mm인 경우 이론적 최대 집광비가 50이었다. PTC의 축방향으로는 균일한 태양조사가 있게된다는 것을 가정하여 모델의 길이는 간편한 실험을 위해 150에서 500 mm의 범위에서 제작하였다. 수평으로 놓인 PTC의 상부 초점 위치로부터 집광면이 아래 쪽에 위치할수록 집광 조사 면적이 증가하므로 PV cell의 크기에 따라 PTC 초점의 위치로부터 거리를 결정하였다. 한편, PTC 자체의 성능도 촛점거리와 집광면 폭의 비에 따라 달라질 수 있다는 가정 하에, 포물면의 최저 위치로부터 촛점거리는 각각 300, 400 및 500 mm가 되도록 세가지 형태를 제작하여 사용하였다. 동일한 형태의 PTC에서 PV cell의 동일한 설치 위치에서도 최고 $110^{\circ}C$ 범위의 PV cell의 작동 (표면) 온도에 따른 성능의 차이를 관찰하기 위해 셀의 후면을 냉각시키는 경우와 그렇지 않은 경우를 비교하였다. PV cell의 표면 온도 측정을 위해서, 후면의 온도와 같이 광선 차단 효과의 우려가 없는 경우에는 열전대를 설치하였으며, 셀의 전면 온도 측정을 위해서는 비접촉식 적외선 온도계를 사용하였다. 냉각 방법으로는 공기를 이용한 자연대류와 액체를 사용하는 강제대류의 경우를 고려하였으며, 필요에 따라 적절히 설계된 히트싱크를 설치하여 비교 실험을 진행하였다. 강제대류 냉각의 경우는 항온조를 사용하여 순환하는 냉각수의 유량과 공급온도를 변화시킴으로써 PV cell의 작동온도를 조절하고, 이에 따른 발전 성능의 변화를 관찰하였다. 본 연구에서 도출한 실험 및 분석 결과는 PV cell의 설치 환경과 작동온도의 변화에 따라 그 성능 변화를 예측할 수 있는 기술적 자료를 제공함으로써 에너지 이용의 합리화를 도모하는데 기여할 수 있을 것이다.

  • PDF

A Study on the Thermal Characteristics of COB LED using Thermoelectric Element (열전소자를 이용한 COB LED의 열적 특성 분석에 관한 연구)

  • Kim, Hyo-Jun;Kim, Tae-Hyung;Kim, Yong-Kab;Hoang, Geun-Chang
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.9 no.12
    • /
    • pp.1435-1440
    • /
    • 2014
  • This paper was designed to analyze thermal properties using thermoelectric element for air-cooling heat dissipation of 13.2W-class COB LED. For comparative analysis with generally used air cooling methods, the heat sink was designed and produced, and this experiment was conducted to measure the temperature distribution using a contact thermometer while the COB LED was operating for 100 minutes. One result was about $75^{\circ}C$ for the general cooling method, and the other was $57^{\circ}C$ while the thermoelectric element was operating with applying the current of 0.8A to the thermoelectric element. This results confirmed that the method of applying thermoelectric element was much better in the dissipation of thermal condense on the COB LED than that of the general air cooling one. The temperature on the contact points of COB LED using thermoelectric element was decreased about 31% compared with the air cooling method from $75^{\circ}C$ to $57^{\circ}C$.

Thermal Behaviors and Reaction Characteristics of an Integrated Reactor with Catalytic Combustion-Reforming According to Operation Conditions (운전조건 변경에 따른 통합형 촉매연소-개질반응기의 열적 거동 및 반응 특성)

  • Ghang, Tae-Gyu;Lee, Sang-Min;Ahn, Kook-Young;Kim, Yong-Mo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.6
    • /
    • pp.641-648
    • /
    • 2011
  • Off-gases emitted from the anode of a molten carbonate fuel cell (MCFC) at high temperatures for power generation are used as fuel in catalytic combustion. The heat generated in the catalytic combustor is utilized as the heat for the endothermic reaction required for steam reforming. Among the various operational conditions of the integrated reactor, we varied the inlet gas compositions of the catalytic combustor according to fuel utilization in the MCFC and the ratio of steam to carbon in the reformer. Subsequently, the thermal behaviors and reaction characteristics of the integrated reactor were investigated experimentally. The fundamental data from this experimental study will be useful for the design and fabrication of a more practical integrated reactor in the future.

Evaluation of Thermal Properties for the Far Infrared Therapy After Microvascular Anastomosis for the Treatment of Circulatory Diseases (미세혈관 문합 후 순환계 질환 개선을 위한 원적외선 치료기의 열적 특성 평가)

  • Yang, Young-Kyu;Oh, Seung-Hyun;Kim, Cheol-Woong
    • Transactions of the KSME C: Technology and Education
    • /
    • v.1 no.2
    • /
    • pp.179-186
    • /
    • 2013
  • Far-infrared radiation therapies are becoming more popular for blood circulation disorders, cardiovascular disease, skin diseases, inhibit cancer cell, etc replacing conventional operations. In this research, thermal characteristics of heating part in panel radiators, which is effective on the blood circulation disorders were experimentally analyzed. The heating line supplies heat energy to insulation coatings with heat flux of $150mW/m^2$ in normal status and as a result the coatings reached 20% of the heating line temperature. In other words, the insulation itself could increase surface temperature of heating plates by 20% and raise thermal time constant promote blood circulation effect. We also found that space arrangement of the heating lines was an important factor in designing heating parts and both coefficient of heat conduction and density of the heating plate should be also considered for superimpose of thermal diffusion.

A Study on the new MBT management system with variations of MSW's seasonal emission characteristics (생활폐기물의 계절별 성상변화에 따른 MBT 시스템 관리에 관한 연구)

  • Min, Byong-Hoon;Chung, Chan-Kyo;Kim, Jong-Moon;Min, Dul-le;Lim, Seung-Bin;Lee, Chae-Young;Kim, Hyung-Jin
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.18 no.4
    • /
    • pp.54-63
    • /
    • 2010
  • When MBT(Mechanical Biological Treatment) facility is designed, the management system adequate for domestic circumstance in Korea has been insufficient and power plant's load on seasonal variation has not been resolved yet. Thus, this study introduced MBT facility and MSW(Municipal Solid Waste)'s seasonal emission characteristics were investigated in order to establish new MBT management system. and additional thermal buffer-materials's calorific values were also considered to reduce the power plant's load. The results showed that the screening efficiency of MBT facility and the physical characteristics of each waste can be identified, and the calorific value by seasonal variation for MBT facility can be kept constant all the year round by using an additional thermal buffer-materials.

Experimental Investigation of Flow Assurance due to Heating Method in Offshore Pipeline (해양플랜트 파이프라인 가열방식에 따른 유동 안정성 실험 연구)

  • Sohn, Sangho;Park, Jaebum;Lee, Jungho
    • Transactions of the KSME C: Technology and Education
    • /
    • v.3 no.1
    • /
    • pp.45-53
    • /
    • 2015
  • The fact that gas hydrate and/or paraffin wax is frequently plugged in offshore pipeline has been become very significant for offshore piepline flow assurance. An active electrical heating along pipeline has adapted in resolving flow assurance problem like as gas hydrate and wax plugging. This study represents a novel internal-swirled heater which was designed and fabricated for more effective heating and thermal mixing through pipeline. The internal-swirled heater suggested in this study shows higher thermal mixing performances than the conventional external-traced heater.