• Title/Summary/Keyword: 열적변수

Search Result 155, Processing Time 0.031 seconds

A Time-series Analysis of the Influence Factors on Public Library Patron Numbers (공공도서관 고객 규모의 영향요인에 대한 시계열분석)

  • Lee, Kyeong-Jin;Song, Myung-Gyu
    • Journal of the Korean Society for Library and Information Science
    • /
    • v.54 no.4
    • /
    • pp.195-220
    • /
    • 2020
  • This study aims at identifying the influence factors on public library patron numbers through a time-series analysis using the Korean National Libraries Statistical Data from 2014 to 2019. The facts found can be summarized as follows; First, the variables of books collection and periodicals appeared constantly to be unsignificant in the influence on public library patron numbers through the period from 2014 to 2019. This suggests that the internet may be substituting public libraries in the service of access to ordinary books and periodicals, which has been considered as a main function of public libraries. Second, such factors as cultural or books programs, library operation, user activities, and facilities turned out to be more significant and continual in the influence on public library patron numbers than the factor of books collection and storage. This means that public libraries have a complementary relation with the internet in these fields.

Material Topology Optimization of FGMs using Homogenization and Linear Interpolation Methods (균질화 및 선형보간법을 이용한 기능경사 내열복합재의 물성분포 최적설계)

  • 조진래;박형종
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.14 no.4
    • /
    • pp.495-503
    • /
    • 2001
  • In a functionally graded materials(FGM), two constituent material particles are mixed up according to a specific volume fraction distribution so that its thermoelastic behavior is definitely characterized by such a material composition distribution. Therefore, the designer should determine the most suitable volume fraction distribution in order to design a FGM that optimally meets the desired performance against the given constraints. In this paper, we address a numerical optimization procedure, with employing interior penalty function method(IPFM) and FDM, for optimizing 2D volume fractions of heat-resisting FGMs composed of metal and ceramic. We discretize a FGM domain into finite number of homogenized rectangular cells of single design variable in order for the optimization efficiency. However, after the optimization process, we interpolate the discontinuous volume fraction with globally continuous bilinear function in order to enforce the continuity of volume fraction distributions.

  • PDF

Preparation and Characterization of Cobalt Silicide Films for Printing Heater (프린팅 히터용 코발트실리사이드 박막의 형성과 특성연구)

  • 장호정;노영규
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.9 no.2
    • /
    • pp.49-54
    • /
    • 2002
  • Cobalt silcides thin films were prepared on Poly-Si/$SiO_2$/Si substrates by Co metal depostion using E-beam evaporation method and rapid thermal annealing for the application of inkjet printing heater. The crystal phases and composition distributions of the films were investigated as functions of the rapid thermal annealing (RTA) temperatures (600~$900^{\circ}C$) and times (20~40 sec). The high temparature thermal stability was also investigated by the analysis of sheet resistance and crystalline properties. The stable $CoSi_2$ phases were obtained by the RTA annealing at $800^{\circ}C$ for 20 seconds showing $0.8 \Omega /\Box$ of sheet resitance. However, the sheet resistances were sharply increased at below $700^{\circ}C$ due to changes of crystalline phases. The temperature resistance coefficient of heating elements was found to be about $0.0014/^{\circ}C$, and the obtained cobalt silicided films can be applied to the printer heating elements.

  • PDF

Classification of Indoor Environmental Gases Using Temperature Modulation (열적 변화를 이용한 실내환경 가스의 분류)

  • Choi, Nak-Jin;Shim, Chang-Hyun;Song, Gap-Duk;Joo, Byung-Su;Lee, Yun-Su;Lee, Sang-Moon;Lee, Duk-Dong;Huh, Jeung-Soo
    • Journal of Sensor Science and Technology
    • /
    • v.11 no.5
    • /
    • pp.279-285
    • /
    • 2002
  • Two $SnO_2$ based sensing films(pure $SnO_2$ and $SnO_2$/Pt) and a Pt thin film for temperature sensor on an alumina substrate were designed and fabricated for classifying the indoor environmental gases. By controlling the heating power in the shape of trapezoid, unique four sensing response curves created from both $SnO_2$ film and $SnO_2$/Pt film. Then, various parameters were extracted from sensing response curves and carried out principal component analysis(PCA). The results confirm that a sensor array with the proposed operating mode was extremely effective in classifying indoor environmental gases such as $CO_2$, $C_3H_8$, $C_4H_{10}$.

Effect of Aggregate on Mechanical Properties of Ultra-High Strength Concrete Exposed to High Temperature (고온을 받은 초고강도 콘크리트의 역학적 특성에 관한 골재의 영향)

  • Kim, Young-Sun;Choi, Hyoung-Gil;Ohmiya, Yoshifumi;Kim, Gyu-Yong
    • Journal of the Korea Concrete Institute
    • /
    • v.23 no.4
    • /
    • pp.431-440
    • /
    • 2011
  • Concrete structures exposed to fire produce changes in their internal structure, resulting in their service life reduction due to the deterioration of its strength and performance capacity. The deterioration level are dependent on the temperature, exposure time, concrete mix proportions, aggregate property, and material properties. This study was performed to evaluate the thermal behavior of ultra-high strength concrete for the parameters of water to cement ratio (compressive strength), fine to total aggregate ratio, and maximum coarse aggregate size. At room temperature and $500^{\circ}C$, tests of ultrasonic pulse velocity, resonance frequency, static modulus of elasticity, and compressive strength are performed using ${\varnothing}100{\times}200\;mm$ cylindrical concrete specimens. The results showed that the residual mechanical properties of ultra-high strength concrete heated to $500^{\circ}C$ is influenced by variation of a water to binder ratio, fine to total aggregate ratio, and maximum coarse aggregate size.

Fire Resistance Performance of Precast Segmental Concrete Lining for Shield Tunnel (쉴드 터널용 프리캐스트 세그먼트 콘크리트 라이닝의 내화성능)

  • Han, Byung-Chan;Harada, kazunori;Kwon, Young-Jin;Kim, Yun Yong
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.34 no.1
    • /
    • pp.95-105
    • /
    • 2014
  • Reinforced concrete (RC) shield tunnel lining must be designed for fireproof performance because the lining is sometimes exposed to very high temperature due to traffic accidents. Both experimental and numerical studies are carried out to evaluate fire resistance performance of precast RC tunnel lining systems. In the experimental studies, six full-scale precast RC tunnel segments are exposed to fire in order to examine the influence of various parameters on the fire resistance performance of precast RC tunnel lining. We used the temperature curve of the RABT criteria, which are severe conditions of fire temperatures. The fire test showed that the explosive spalling was not observed by substituting concrete to PP fiber reinforced concrete. A transient heat flow analysis was carried out in consideration of the material properties that change with temperature, and the results showed good agreement with the test results.

A study on the measurement of thermophysical properties of ${Al}_{2}{O}_{3}, {Si}_{3}{N}_{4}$ and SiC series by a single rectangular pulse heating (방향파 펄스 가열에 의한 ${Al}_{2}{O}_{3}, {Si}_{3}{N}_{4}$, SiC 계열의 열물성치 측정에 관한 연구)

  • 차경옥;장희석;이흥주
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.1
    • /
    • pp.145-156
    • /
    • 1990
  • In this study, thermophysical properties of the engineering ceramic materials such as $Al_{2}$O$_{3}$, Si$_{3}$N$_{4}$ and SiC were measured b y a single rectangular pulse heating method. The values of thermal diffusivities, specific heats, and thermal conductivities were measured as a function of temperature ranging form room temperature to 1300K. The measured thermal properties of one group of ceramic material were compared with those of other group and discussed in detail in connection with the chemical composition. Thus, some criteria for thermal design with the engineering ceramic materials were proposed.

A Study on Thermo-properties of Fluorine Doped Tin Oxide Thin Film by APCVD Technique (APCVD법으로 성막된 SnO2:F 박막의 열적 특성 연구)

  • Kim, Yu-Seung;Ok, Yun-Deok;Kim, Min-Koung;Yi, Bo-Ram;Kim, Byung-Kuk;Lee, Jung-Min;Kim, Hoon;Kim, Hyung-Jun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.37-40
    • /
    • 2009
  • 불소가 도핑된 산화주석(SnO2:F, FTO) 박막은 다결정 전도성 세라믹으로 가시광선 영역에서 투명하기 때문에 태양전지의 전극으로 활용된다. 본 연구에서 FTO는 APCVD법으로 성막되었다. BSG기판을 사용하여 $620^{\circ}C$의 고온에서 공정이 진행되었다. 이렇게 제작된 FTO 박막은 수소, 질소, 대기 분위기에서 여러 열처리 시간을 변수로 실험하여 열처리 전후의 전기적, 광학적, 구조적 변화를 관찰하고 분석하였다. 전기적 특성 분석에는 전기 비저항, 모빌리티 및 캐리어 농도 등의 변화를 알아보았고, 광학적 분석에는 UV-vis spectoscopy로 200nm에서 800nm 파장대역의 투과도를 구하고, Hazemeter를 통하여 총투과율, 평행투과율, 확산투과율 및 Haze를 분석하여 FTO막이 가지고 있는 texturing에 의한 효과를 알아보기 위하여 시편의 열처리 전후를 비교 분석하였다. 구조적 분석은 XRD를 이용하여 pattern을 분석하여 FTO가 가지는 구조변화를 분석하였다. 특히 FTO의 texturing에 기여도가 높은 (200)면의 XRD peak강도가 상승함에 따라 후열처리에 의해 박막의 표면의 변화가 일어남을 확인하였다. FTO의 후열처리에 의한 변화는 전기적으로는 약간의 전기 비저항의 증가를 가져오며, 캐리어 농도의 감소를 가져온다. 캐리어 농도의 감소에 따라 모빌리티의 상승이 관찰되었다. 광학적 특성은 가시광선 영역에서 투과율은 거의 같거나 약간 감소하는 경향을 나타내며, 후열처리 전후에 거의 동일한 투과율을 보이면서도 확산 투과율이 상승하는 분석 결과를 얻었다.

  • PDF

Structure Design and Thermal Analysis of Cryogenic Cooling System for a 1500 A, 400 mH Class HTS DC Reactor (1500 A, 400 mH급 초전도 직류 리액터용 극저온 냉각 시스템 구조 설계 및 열 해석)

  • Quan, Dao-Van;Le, Tat-Thang;Sung, Hae-Jin;Park, Min-Won;Yu, In-Keun
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.23 no.1
    • /
    • pp.31-41
    • /
    • 2018
  • This paper discusses a structure design and thermal analysis of cryogenic conduction cooling system for a high current HTS DC reactor. Dimensions of the conduction cooling system parts including HTS magnets, bobbin structures, current leads, support bars, and thermal exchangers were calculated and drawn using a 3D CAD program. A finite element method model was built for determining the optimal design parameters and analyzing the thermo-mechanical characteristics. The operating current and inductance of the reactor magnet were 1,500 A, 400 mH, respectively. The thermal load of the HTS DC reactor was analyzed for determining the cooling capacity of the cryo-cooler. Hence, we carried out the operating test of conduction cooling system of the 1st stage area with high current flow. The cooper bars was cooled down to 40 K and HTS leads operated stably. As a experiment result, the total heat load of the 1st stage area is 190 W. The study results can be effectively utilized for the design and fabrication of a commercial HTS DC reactor.

Training Sample of Artificial Neural Networks for Predicting Signalized Intersection Queue Length (신호교차로 대기행렬 예측을 위한 인공신경망의 학습자료 구성분석)

  • 한종학;김성호;최병국
    • Journal of Korean Society of Transportation
    • /
    • v.18 no.4
    • /
    • pp.75-85
    • /
    • 2000
  • The Purpose of this study is to analyze wether the composition of training sample have a relation with the Predictive ability and the learning results of ANNs(Artificial Neural Networks) fur predicting one cycle ahead of the queue length(veh.) in a signalized intersection. In this study, ANNs\` training sample is classified into the assumption of two cases. The first is to utilize time-series(Per cycle) data of queue length which would be detected by one detector (loop or video) The second is to use time-space correlated data(such as: a upstream feed-in flow, a link travel time, a approach maximum stationary queue length, a departure volume) which would be detected by a integrative vehicle detection systems (loop detector, video detector, RFIDs) which would be installed between the upstream node(intersection) and downstream node. The major findings from this paper is In Daechi Intersection(GangNamGu, Seoul), in the case of ANNs\` training sample constructed by time-space correlated data between the upstream node(intersection) and downstream node, the pattern recognition ability of an interrupted traffic flow is better.

  • PDF