• Title/Summary/Keyword: 열저항식

Search Result 106, Processing Time 0.033 seconds

Development of Compensation-Type Fire Detector Using Metal-Insulator-Transition Critical-Temperature Sensor (금속-절연체 전이 임계온도센서를 이용한 보상식 화재 감지기 개발)

  • Jung, Sun-Kyu;Kim, Hyun-Tak
    • Fire Science and Engineering
    • /
    • v.28 no.1
    • /
    • pp.26-30
    • /
    • 2014
  • A Compensation-type fire detector (CFD) is operated with two functions of a differential-temperature detector and as a fixed-temperature detector. The differential-temperature detector observes a rate of temperature increase, and the fixed-temperature detector measures a given fixed temperature. The differential-temperature detector does not observe the outbreak of fire in slowly increasing temperature conditions, whereas the fixed-temperature detector is not able to observe the outbreak of fire in conditions under predetermined temperature level. We developed a CFD to compensate for weaknesses of both detectors. To compensate for the disadvantages, a sensor of the sensor metal-insulator-transition critical-temperature sensor was used. Temperature coefficient of resistance is the sensitivity for sensor. At $55^{\circ}C$, temperature coefficient of resistance of metal-insulator-transition critical-temperature sensor was 14.15%. Temperature coefficient of resistance of thermistor was about 0.5%. This CFD was operated as two ways that fixed-temperature detector and differential-temperature detector in one sensor.

The Measurement of Membrane Deformation Behavior in Kogas Pilot LNG Storage Tank by the use of Mechanical/Electrical Sensor (I) (기계적/전기적 측정 센서를 이용한 Kogas Pilot LNG 저장탱크 멤브레인 변형 거동 측정(I))

  • Kim Y.K.;Hong S.H,;Oh B.T.;Yoon I.S.;Kim J.H.;Kim S.S.
    • Journal of the Korean Institute of Gas
    • /
    • v.7 no.3 s.20
    • /
    • pp.13-17
    • /
    • 2003
  • A membrane unit for Liquefied Natural Gas (LNG) storage tank is a structural member which is designed specifically for preventing undesirable LNG leakage. Membrane units have to endure gas and liquid pressures by LNG and thermal stresses by the contact with cryogenic liquid of $-162^{\circ}C$. It is of importance to assure the strengths of membrane by experimental stress analysis under the temperature of LNG. In this paper, we proposed measurement system using commercial electrical strain gage and mechanical extension meter designed for this study.

  • PDF

Optimization of Evaporator for a Vapor Compression Cooling System for High Heat Flux CPU (고발열 CPU 냉각용 증기 압축식 냉각 시스템의 증발기 최적화)

  • Kim, Seon-Chang;Jeon, Dong-Soon;Kim, Young-Lyoul
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.32 no.4
    • /
    • pp.255-265
    • /
    • 2008
  • This paper presents the optimization process of evaporator for a vapor compression cooling system for high heat flux CPU. The CPU thermal capacity was given by 300W. Evaporating temperature and mass flow rate were $18^{\circ}C$ and 0.00182kg/s respectively. R134a was used as a working fluid. Channel width(CW) and height(CH) were selected as design factors. And thermal resistance, surface temperature of CPU, degree of superheat, and pressure drop were taken as objective responses. Fractional factorial DOE was used in screening phase and RSM(Response Surface Method) was used in optimization phase. As a result, CW of 2.5mm, CH of 2.5mm, and CL of 484mm were taken as an optimum geometry. Surface temperature of CPU and thermal resistance were $33^{\circ}C\;and\;0.0502^{\circ}C/W$ respectively. Thermal resistance of evaporator designed in this study was significantly lower than that of other cooling systems such as water cooling system and thermosyphon system. It was found that the evaporator considered in this work can be a excellent candidate for a high heat flux CPU cooling system.

Analysis and extraction method of noise parameters for short channel MOSFET thermal noise modeling (단채널 MOSFET의 열잡음 모델링을 위한 잡음 파라메터의 분석과 추출방법)

  • Kim, Gue-Chol
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.12
    • /
    • pp.2655-2661
    • /
    • 2009
  • In this paper, an accurate noise parameters for thermal noise modeling of short channel MOSFET is derived and extracted. Fukui model for calculating the noise parameters of a MOSFET is modified by considering effects of parasitic elements in short channel, and it is compared with conventional noise model equation. In addition, for obtaining the intrinsic noise sources of devices, noise parameters(minimum noise figure $F_{min}$, equivalent noise resistance $R_n$ optimized source admittance $Y_{opt}=G_{opt}+B_{opt}$) in submicron MOSFETs is extracted. With this extraction method, the intrinsic noise parameters of MOSFET without effects of probe pad and extrinsic parasitic elements from RF noise measurements can be directly obtained.

The Effect of Forced Temperature Change Cycles on Physical and Mechanical Properties of Sand and Weathered Granite Soil (흙과 열유도 토목섬유 접촉면의 마찰저항 특성)

  • Shin, Seung-min;Sin, Chun-won;Yoo, Chung-Sik
    • Journal of the Korean Geosynthetics Society
    • /
    • v.16 no.2
    • /
    • pp.175-181
    • /
    • 2017
  • This paper presents the results of an investigation into the effect of forced temperature change cycles on physical and mechanical properties of sand and weathered granite soil. The effect of forced temperature change cycles on the particle arrangement and the thermal conductivity was first investigated. A series of triaxial compression tests on the soils were also performed to look into the effect of temperature change cycles on the stress-strain-strength behavior.

A Study on an External Thermal Resistance Equation of Underground Tunnel in Korea (우리나라 실정에 맞는 전력구에 대한 외부열저항 계산식에 관한 연구)

  • Jeong, S.H.;Kim, D.K.;Choi, S.B.;Bae, J.H.;Ha, T.H.;Lee, H.G.;Gwag, B.M.;Yoon, H.H.;Kang, J.W.
    • Proceedings of the KIEE Conference
    • /
    • 2000.11a
    • /
    • pp.162-164
    • /
    • 2000
  • This paper compares some calculation equations of the external thermal resistance in underground tunnel. As result, this paper suggests the external thermal resistance equation suitable for Korea's underground tunnel.

  • PDF

Measurement of reflection coefficient of sound absorbent material in a free space : its possibility and practical applicabilities (자유 공간에서의 흡음재 반사 계수 측정 가능성 및 실용성)

  • 이수열;김양한
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1994.04a
    • /
    • pp.206-211
    • /
    • 1994
  • 본 연구에서는 임의의 복소 음압 분포를 무한 평면에서 공간상의 Fourier 변환을 하여서 평면파 요소들의 중첩으로 해석하는 방법을 살펴보고 제한된 측정 조건에서 유발되는 문제들을 음원의 주파수에 대해서 모의 실험을 통하여 고찰해보았다. 실험으로는 단단한 시편(hard panel)과 스폰지(sponge)에 대해서 공간상의 fourier 변환을 통해 반사 계수를 얻고 수직입사에 대해 2-마이크로폰 방법으로 구한 반사계수와 비교하였다. 특히 다공성 물질인 스폰지에 대해서는 유동 저항을 측정하여 실험식으로부터 구한 반사 계수와의 비교를 하였으며 공간상의 음압 분포로부터 구한 반사계수에서 창문함수의 영향을 살펴보았다.

  • PDF

A Study on the Performance Analysis of Proportional Automatic Thermostatic Valves in Floor Radiant Heating System (바닥난방 시스템용 비례식 자동온도조절밸브의 성능해석에 관한 연구)

  • Song, Jae-Yeob;Ahn, Byung-Cheon;Kim, Yong-Ki;Lee, Tae-Won
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.52-57
    • /
    • 2007
  • The control characteristics for radiant panel heating system with automatic thermostatic valves were researched by computer simulation and experiment. The unsteady energy analysis using equivalent R-C circuit method and radiation heat transfer analysis of enclosure analysis method with simple structured rooms was performed. The results of flow rate changes of the simulation study are good fit with the ones of experimental one.

  • PDF

Detection of Chatter Vibration in End-Mill Process by Neural Network Methodology (신경회로망을 이용한 엔드-밀 공정에서의 채터검지)

  • Chung, Eui-Sik;Ko, Joon-Bin;Kim, Ki-Soo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.12 no.10
    • /
    • pp.149-156
    • /
    • 1995
  • This paper presents a method of detecting chatter vibration in end-mill process. The detecting system consists of an adaptive signal processing scheme which uses an autore- gressive time-series model and a neural network is proposed and is verified its effectiveness by using acceleration and cutting force signals recorded during slotting in end-mill operations. Expeerimental results indicate that the proposed system provides excellent detection when chatter is occured within the ranges of cutting conditions considered in this study and an effectiveness of the integration of signals is confirmed.

  • PDF

Enhanced Flame Resistant Properties of Aluminum Hydroxide Addition on Electrospun Polyurethane Nanofibers (전기방사법에 의해 제조된 폴리우레탄 나노섬유의 수산화알루미늄 내첨에 의한 내염화 특성 향상)

  • Kim, Hyeong Gi
    • Fire Science and Engineering
    • /
    • v.30 no.6
    • /
    • pp.9-13
    • /
    • 2016
  • Anti-oxidation and flame resistant polyurethane nanofibers were prepared by electrospinning and aluminum hydroxide addition. Electrospinning was carried out under the following procedure conditions; applied voltage, 20 kV; polymer solution feeding rate, 1.2 ml/h; collector rolling speed, 120 rpm; and tip to collector distance, 15 cm. Aluminum hydroxide was added to the prepared polymer solution for electrospinning to enhance the oxidation and flame resistant properties. The thermal properties were investigated by thermogravimetric analysis to determine the polymer decomposition temperature, integral procedure decomposition temperature, final decomposition temperature, and remaining amount after thermal decomposition. The activated energy for polymer degradation was also investigated using the Horowitz-Metzger equation. The activation energy increased to more than 50%. The thermal properties of the polyurethane nanofibers were improved by a hydration reaction during the thermal decomposition of aluminum hydroxide around $300{\sim}500^{\circ}C$.