• Title/Summary/Keyword: 열재생

Search Result 843, Processing Time 0.023 seconds

Analysis of a Pin Fin with Variable Fin Base Thickness (핀 바닥두께가 변하는 pin 핀의 해석)

  • Kang, Hyung-Suk
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.642-645
    • /
    • 2008
  • A pin fin with variable fin base thickness is analysed by using the one dimensional analytic method. Heat loss and fin thermal resistance are presented as a function of the fin base thickness, pin fin outer radius and convection characteristic numbers ratio. The relationship between the fin outer radius and fin base thickness for the same amount of heat loss is shown. One of the results indicates the fin thermal resistance decreases as the fin outer radius and/or convection characteristic numbers ratio increase whereas the fin thermal resistance is independent on the variation of fin base thickness.

  • PDF

The Pyrolytic Behavior Waste Tire under Microwave Heating (마이크로파 가열에 의한 폐타이어 열분해 거동)

  • Kim, Seong-Soo;Kim, Ji-Geon;Cho, Jung-Lae;Park, Dong-Chul
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.471-474
    • /
    • 2008
  • The pyrolytic behavior of waste tire under microwave heating was investigated. Experiments were conducted using a lab- and bench-scale system to delineate the effects of microwave output power on the response. As the results of experiments, it was found that as the microwave output power was increased between 0.84 and 3.04 kW/kg, the oil yield and required time rapidly increased and decreased, respectively. With further increase of the microwave output power, the oil yield and required time did not change significantly.

  • PDF

Design and Construction Experiences of 10kWe Dish-type Solar Thermal Power Generation System (Dish형 집광장치 이용 10kWe급 태양열 발전시스템 설계 및 시공 사례)

  • Lee, Sang-Nam;Kang, Yong-Heack;Jo, Dok-Ki;Yu, Chang-Kyun;Yoon, Hwan-Ki;Kim, Jin-Soo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.11a
    • /
    • pp.684-687
    • /
    • 2005
  • KIER has been running a demonstration project for 10kWe solar thermal power generation. the project is to build and operate the first solar thermal power generation system in Korea. For concentrating solar thermal energy $40m^2$ dish type concentrator was adapted and a stirling engine is going to be integrated to the system for power production. At the moment building the dish concentrator including mirror and sun tracking system was completed and it's performance are being closely evaluated. This paper will introduce some detailed designs and construction procedures which we have experienced so far.

  • PDF

A Study on the Thermal Performance of Solar Concentrating Cooker (집광형 태양열 조리기의 집열성능에 관한 연구)

  • Kang, Myeong-Cheol;Kang, Yong-Heack;Yoon, Hwan-Ki;Yoo, Seong-Yeon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.11a
    • /
    • pp.599-603
    • /
    • 2005
  • To evaluate the performance of concentrating solar cookers, a parabolic solar cooker have been designed and constructed. Tests were carried out to define the performance characteristics of concentrating cookers under ambient conditions. The performance and test of the solar cooker were measured and conducted using the international standard procedure that was proposed at the Third World Conference on solar cooking. Stagnation temperature and water heating tests were carried out to determine the maximum temperature attained by the cooker and to evaluate the thermal performance of the cooker. The analysis showed that the solar cooker has maximum cooking power and efficiency 474W, 420W and 41%, 40%, respectively.

  • PDF

Investigation of ground thermal characteristics for performance analysis of borehole heat exchanger (지중 열교환기 성능 분석을 위한 지반 열물성 조사)

  • Shim, Byoung-Ohan;Song, Yoon-Ho;Kim, Hyoung-Chan;Cho, Byong-Wook;Park, Deok-Won;Im, Do-Hyung;Lee, Young-Min
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.11a
    • /
    • pp.587-590
    • /
    • 2005
  • A detailed geothermal characteristics survey with numerical simulations of the heat transfer in a site for ground source heat pump system is necessary for deploying a shallow geothermal utilization system. Density, specific heat, thermal diffusivity, and thermal conductivity are measured on 91 core samples from a 300 m deep borehole in KIGAM(Korea Institute of Geoscience and Mineral Resources). The heat flow is estimated from the thermal gradient and average thermal conductivity and the correlation between fracture system and hydraulic conductivity is analyzed. From the obtained ground information of the study site the performance of the ground heat pump system can be analyzed with some detailed numerical simulations for seasonal heat pump operation skill and optimal system design techniques.

  • PDF

Development of Technology on Water Thermal Energy Utilization of Riverbank(including Alluvial and Riverbed deposits) Filtration (강변여과수(충적층 및 하상) 열자원 활용 기술 개발)

  • Kim, Hyoung-Soo;Seo, Min-Woo;Jung, Woo-Sung;Song, Yoon-Ho
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.11a
    • /
    • pp.591-594
    • /
    • 2005
  • Geothermal energy becomes to be one of the promising energy sources. In this study, technology using water thermal energy from riverbank filtration system(including alluvial and riverbed deposit) is reviewed and checked as an energy resources. The objects of this study are (1) long-term monitoring of alluvial and riverbed sites, (2) preliminary design of cooling and heating system at riverbank filtration facility, and (3) calculation of potential groundwater heat energy, including riverbank filtration system. Measuring data of alluvial and riverbank filtration show slight fluctuations comparing to temperature of atmospheric air which indicates that groundwater obtained from the riverbank filtration system have a sufficient potential as a source of cooling and heating energy.

  • PDF

Optimization of Heat Pump Systems (열펌프의 성능 최적화에 관한 연구)

  • Choi, Jong-Min;Yun, Rin;Kim, Yong-Chan
    • New & Renewable Energy
    • /
    • v.3 no.4
    • /
    • pp.22-30
    • /
    • 2007
  • An expansion device plays an important role in optimizing the heat pumps by controlling refrigerant flow and balancing the system pressures. Conventional expansion devices are being gradually replaced with electronic expansion valves due to increasing focus on comfort, energy conservation, and application of a variable speed compressor. In addition, the amount of refrigerant charge in a heat pump is another primary parameter influencing system performance. In this study, the flow characteristics of the expansion devices are analyzed, and the effects of refrigerant charge amount on the performance of the heat pump and the variation of compressor speed are investigated at various operating conditions. Mass flow rate through capillary tube, short tube orifice, and EEV was strongly dependent on the upstream pressure and subcooling. The heat pump system is very sensitive with a variation of refrigerant charge amount. The performance of it can be optimized by adjusting the flow rate through expansion device to maintain a constant superheat at all test conditions.

  • PDF

Thermal Performance of a Thermosiphon with a Step-Change Elevation for Medium-temperature Solar Thermal Applications (중온 태양열 응용을 위해 수평 단차를 갖는 열사이펀의 열적 성능)

  • Lee, Se-Kwon;Jung, Eui-Guk;Boo, Joon-Hong
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.251-254
    • /
    • 2009
  • Thermal performance of a thermosiphon for medium-temperature solar thermal application was investigated. The working fluid was Dowtherm A and the container was made of STS 316L. The thermosiphon had a outer diameter of 12.7 mm and a total length of 2 m, where the evaporator and the condenser had the same length of 0.3 m and the adiabatic section was 1.4 m. Both the evaporator and the condenser were aligned horizontal with an elevation difference of 0.18 m to utilize the gravitational force for the working-fluid return. The optimum fill charge ratio of the working fluid was investigated to obtain the maximum heat transport with the lowest thermal resistance. The maximun input thermal load was 500 W and thermal resistance was $0.60^{\circ}C/W$.

  • PDF

Performance Characteristics of a Liquid-Metal Heat Pipe for igh-temperature Solar Thermal Devices Depending on the Operating Conditions (고온 태양열기기용 액체금속 히트파이프의 작동조건에 따른 성능 특성)

  • Park, Cheol-Min;Lee, Jung-Ryun;Boo, Joon-Hong;Kang, Yong-Heack
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.247-250
    • /
    • 2009
  • Sodium heat pipe for high-temperature solar thermal application was manufactured and tested for transient and steady-state operations. Total length of the heat pipe was 650 mm and the outer diameter was 12.7 mm. Thermal performance was compared experimentally for two different cooling methods of the forced and the natural convection cooling in the heat pipe condenser. During the experiment, the maximum temperature was about 1300K, and different cooling methods were applied to the condenser region to charge the operating temperature. The effective thermal conductivity and the thermal resistance were investigated as a function of heat flux, heat transport length, and operating temperature.

  • PDF

A Study on the BOS control of a small PEM fuel cell stack (소형 PEM 연료전지 스택의 BOS 제어에 관한 연구)

  • Kim, Tae-Hoon;Choi, Woo-Jin
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.274-277
    • /
    • 2009
  • 본 논문에서는 소형 PEM(Proton Exchange Membrane) 연료전지 스택의 BOS(Balance of Stack) 제어에 관하여 논의한다. 별도의 가습 장치가 필요치 않고 BOS의 구성이 비교적 간단한 소형 PEM 연료전지 시스템에서는 팬과 퍼지밸브만의 제어를 통해 스택 내부 수분의 조절과 열 관리가 수행된다. 따라서 본 논문에서는 부하에 따른 최적의 공기유량을 계산하고 요구되는 유량의 공급을 위해 팬을 제어하는 알고리즘을 통해 소형 연료전지 시스템의 과도응답 특성과 안정성을 향상시키는 방법에 관하여 제안한다. 150W급 소형 연료전지 시스템을 꾸미고, 마이크로컨트롤러를 이용한 제어회로를 구현하여 실험함으로써 제안된 알고리즘의 유용함을 검증하였다.

  • PDF