• Title/Summary/Keyword: 열응답

Search Result 421, Processing Time 0.024 seconds

A Study on Dynamic Performance and Response of Turbo Shaft Engine for SUAV (스마트 무인항공기용 터보축 엔진의 동적성능과 응답성에 관한 연구)

  • Park Jun-Cheol;Roh Tae-Seong;Choi Dong-Whan;Yang Soo-Seok
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.9 no.2
    • /
    • pp.17-24
    • /
    • 2005
  • In this study, the GSP and in-house numerical codes have been used for analyses of the on-design, static off-design and dynamic off-design performances. Through the various missions including altitude, velocity, and power variations the static engine performance have been investigated. The dynamic engine performances based on these complicated variations have been also analyzed. Especially, the power, engine rpm and heat overload characteristics of the turbine have been estimated with the response time through the control of the throttle setting rather than the power setting. It could be applied to the FADEC system as an engine control device.

A Study on Design and Performance of a Heat pipe for the Application to Solar Collector (태양열 집열기용 열파이프의 구조와 작동 특성에 관한 연구)

  • 임광빈;김철주
    • Journal of Energy Engineering
    • /
    • v.2 no.2
    • /
    • pp.179-186
    • /
    • 1993
  • Heat pipes. applied to a flat plate solar collector, have a long and slender configuration with relatively low heat flux in the evaporator section. Such a heat pipe has a tendency to build-up a liquid pool at the lower part of the evaporator section. and at this pool occurs such complicated phenomena of evaporation and fluid dynamics as superheat, sudden generation of bubble, its likely explosive growth process and flooding, etc. In the present study. we tried to solve these problems by means of adjusting two principal design parameters, the liquid inventory and the installation region of the wick, using 4 heat pipes and 3 thermospheres. The corresponding results can be summarized as follows$\^$1)/. The effective thermal conductances of the heat pipe was greatly improved by eliminating the wick in the adiabatic and condenser sections$\^$2)/. The liquid inventory should be increased by about 40% larger than what is saturated the wick$\^$3)/. In the evaporator section the wick has a favorable effect to reduce both unstable operation by intermittent occurrence of nucleate boiling and response time at the initial start-up process.

  • PDF

Query Optimization Techniques for Horizontal Tables in OLAP Environment (OLAP 환경의 수평적인 테이블에 대한 질의 최적화 방법)

  • Shin Sung-Hyun;Moon Yang-Sae;Kim Jin-Ho
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2006.06c
    • /
    • pp.70-72
    • /
    • 2006
  • 데이터 웨어하우스는 방대한 이력 데이터들을 저장하는 저장소이며, 이를 다양한 관점에서 분석하기 위해 OLAP (On-Line Analytical Processing) 연산을 이용한다. 일반적으로 이러한 저장소는 데이터를 저장할 때 많은 열(columns) 을 기반으로 저장하는 와이드(wide) 형태의 테이블로 저장하게 된다. 하지만, 관계형 DBMS에서는 열 수의 제약(MS SQLServer, Oracle 등 열의 수는 1024개임)을 받게 되므로, 그 이상의 열들을 저장할 수 없다. 하지만, 열 기반(이하, 수평 테이블)으로 저장하는 것보다는 관계형 DBMS의 특징을 이용하여 행(row) 기반(이하, 수직 테이블)으로 저장하게 되면 많은 데이터를 효율적으로 저장할 수 있다. 이때, 저장 테이블의 스키마 구조가 변경되므로, 수평 테이블에 대한 질의도 저장된 수직 테이블에 적용 가능하도록 변화시켜야 한다. 또한, 사용자에게 빠른 질의 응답을 제공하기 위해 질의 최적화를 고려하여 실행전락을 세워야 한다. 따라서 본 연구에서는 경험(heuristic)을 근거로 각 연산(프로젝션, 실렉션, 조인 연산)을 위한 질의 트리를 생성하여 질의 최적화에 대한 여러 질의 경로를 고려하고, 다양한 실험을 통해 질의 최적화에 대한 접근 경로들을 분석한다. 이로써, 본 연구의 질의 경로 분석을 기반으로 최적화 실행 계획을 기대해 본다.

  • PDF

Evaluation of Ground Effective Thermal Conductivity and Borehole Effective Thermal Resistance from Simple Line-Source Model (단순 선형열원 모델을 이용한 지중 유효 열전도도와 보어홀 유효 열저항 산정)

  • Sohn, Byong-Hu
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.7
    • /
    • pp.512-520
    • /
    • 2007
  • The design of a ground-source heat pump system includes specifications for a ground loop heat exchanger where the heat transfer rate depends on the effective thermal conductivity of the ground and the effective thermal resistance of the borehole. To evaluate these heat transfer properties, in-situ thermal response tests on four vertical test boreholes with different grouting materials were conducted by adding a monitored amount of heat to circulating water. The line-source method is applied to the temperature rise in an in-situ test and extended to also give an estimate of borehole effective thermal resistance. The effect of increasing thermal conductivity of the grouting materials from 0.818 to $1.104W/m^{\circ}C$ resulted in overall increases in effective thermal conductivity by 15.8 to 56.3% and reductions in effective thermal resistance by 13.0 to 31.1%.

Evaluation of Effective Thermal Conductivity and Thermal Resistance in Ground Heat Exchanger Boreholes (지중 열교환기 보어홀에서의 유효 열전도도 및 열저항 산정)

  • Sohn Byong Hu;Shin Hyun-Joon;Park Seong-Koo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.8
    • /
    • pp.695-703
    • /
    • 2005
  • The objective of this study is to determine the effective thermal conductivity and thermal resistance values in test boreholes with three different fill materials. To evaluate these heat transfer properties, in-situ tests on four vertical boreholes were conducted by adding a monitored amount of heat to water over various test lengths. Two parameter estimation models, line-source and numerical one-dimensional models, for evaluation of thermal response test data were compared when applied on the same four data sets. Results show that the average thermal conductivity deviation between measured data and these two models is in the range of $3.03\%$ to $4.45\%$. The effect of increasing grout thermal conductivity from 1.34 to 1.82 $W/m^{\circ}C$ resulted in overall increases in effective formation thermal conductivity by $11.1\%$ to $51.9\%$ and reductions in borehole thermal resistance by $11.6\%$ to $26.1\%$.

The Effects of the Installation Conditions of Ground Loop Heat Exchanger to the Thermal Conductivity and Borehole Resistance (지중열교환기 설치 조건이 지중 유효 열전도도와 보어홀 열저항에 미치는 영향)

  • Lim, Hyo-Jae;Kong, Hyoung-Jin;Kang, Sung-Jae;Choi, Jae-Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.2
    • /
    • pp.95-102
    • /
    • 2011
  • A ground loop heat exchanger in a ground source heat pump system is an important unit that determines the thermal performance of a system and its initial cost. A proper design requires certain site specific parameters, most importantly the ground effective thermal conductivity, the borehole thermal resistance and the undisturbed ground temperature. This study was performed to investigate the effect of some parameters such as borehole lengths, various grouting materials and U tube configurations on ground effective thermal conductivity and borehole thermal resistance. In this study, thermal response tests were conducted using a testing device to 9 different ground loop heat exchangers. From the experimental results, the length of ground loop heat exchanger affects to the effective thermal conductivity. The results of this experiment shows that higher thermal conductivity of grouting materials leads to the increase effective thermal conductivity from 22 to 32%. Also, mounting spacers have increased by 14%.

Evaluation of Ground Effective Thermal Properties and Effect of Borehole Thermal Resistance on Performance of Ground Heat Exchanger (지중 유효 열물성 산정 및 지중열교환기 성능에 대한 보어홀 열저항의 영향)

  • Sohn, Byonghu
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.8 no.4
    • /
    • pp.32-40
    • /
    • 2012
  • Geothermal heat pump(GHP) systems use vertical borehole heat exchangers to transfer heat to and from the surrounding ground via a heat carrier fluid that circulates between the borehole and the heat pump. An Important feature associated with design parameters and system performance is the local thermal resistances between the heat carrier flow channels in the borehole and the surrounding ground. This paper deals with the in-situ experimental determination of the effective thermal properties of the ground. The recorded thermal responses together with the line-source theory are used to determine the thermal conductivity and thermal diffusivity, and the steady-state borehole thermal resistance. In addition, this paper compares the experimental borehole resistance with the results from the different empirical and theoretical relations to evaluate this resistance. Further, the performance simulation of a GHP system with vertical borehole heat exchangers was conducted to analyze the effect of the borehole thermal resistance on the system performance.

Modified Partial Sample Average Algorithm for Noise Variance Estimation (잡음 분산 추정을 위한 개선된 Partial Sample Average 알고리즘)

  • Park, Jung-Jun;Lee, Jinyong;Lim, Taemin;Kim, Younglok
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2010.11a
    • /
    • pp.167-170
    • /
    • 2010
  • 잡음 분산 값은 SNR(signal-to-noise ratio) 추정이나 MMSE(minimum mean square error) 계산, 채널 임펄스 응답의 추정 등에 사용되는 중요한 파라미터이다. 채널이 시간에 따라 변하는 무선 통신 환경에서, 신호와 섞여 있는 잡음과 간섭 신호의 정확한 추정에는 그 한계가 있으며 이로 인해 발생하는 추정 오차는 수신기의 데이터 검출 성능을 저하시킨다. 훈련열을 이용하여 채널을 추정하였을 경우 추정된 채널 임펄스 응답 신호 중 다중 경로 신호는 소수에 불과하고 나머지 대부분의 계수는 잡음 성분만을 포함하는 신호이다. 이러한 특징을 이용하여 채널의 추정 계수로 잡음 분산을 추정하는 방법이 기존에 제시되어 있다. 여기서 제안하는 알고리즘은 기존 알고리즘인 PSA(partial sample average)와 비교해 연산량에서 차이가 거의 없이 구현되며, 3GPP TDD[1]에서의 모의 실험을 통하여 기존 알고리즘보다 더 정확한 분산 값을 찾아냄을 확인하였다.

  • PDF

Dynamic Fiber Bragg Grating sensor system using edge slope of Super Luminescent Diode light source (광원의 기울기를 이용한 동적 광섬유 격자 센서 시스템)

  • Lee, Jung-Woo;Cho, Sung-Kyu;Han, Jung-Yeol;Park, Sung-Hoon;Jung, Chul;Jeon, Jae-Heung;Kim, Ki-Soo
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2002.07a
    • /
    • pp.58-59
    • /
    • 2002
  • 광섬유 격자(Fiber Bragg Grating)는 광통신 및 센서 분야에 매우 유용하다. 이를 이용한 센서는 온도, 스트레인 등을 측정 할 수 있어, 토목, 건설 및 항공분야에 지능형 구조물에 응용하고 있다. 본 논문에서는 이러한 광섬유 격자의 스트레인에 의한 응답특성을 이용한 동적 시스템을 구성하였으며, 광섬유격자에 하중을 인가하여 따른 응답 특성을 측정 분석하였다. (중략)

  • PDF

Analysis of Dynamic characteristics for live-line insulator (단일 활선 애자의 동특성 분석)

  • Oh, Ki-Yong;Park, Joon-Young;Lee, Jae-Kyung
    • Proceedings of the KIEE Conference
    • /
    • 2008.10b
    • /
    • pp.375-376
    • /
    • 2008
  • 송전선로에 절연물로 사용되는 애자는 설치 이후 장시간 사용에 따라 고전압 스트레스, 기계적 스트레스, 열 및 환경 스트레스 등으로 열화가 진행되기 때문에 안정적인 전력설비 운영을 위하여 활건 애자 비파괴 열화 상태 점검이 필요하다. 본 연구에서는 비파괴 상태 진단 감시 기술인 주파수 응답 함수 측정을 통한 고유 진동수 분석을 통하여 현재 활선 애자로 사용되고 있는 NGK210, KRI210, NGK300 및 KRI300 4가지 종류 애자의 동특성 실험을 수행하였으며, 이를 통하여 애자의 결함이 발생하였을 때 고유진동수 변화를 분석하였다.

  • PDF