• Title/Summary/Keyword: 열유체 해석

Search Result 585, Processing Time 0.031 seconds

Study on the Change of Relative Humidity in Subsea Pipeline According to Drying Method (건조 공법에 따른 해저 파이프라인 내부 상대습도 변화 특성 연구)

  • Yang, Seung Ho
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.28 no.2
    • /
    • pp.406-413
    • /
    • 2022
  • The subsea pipeline pre-commissioning stage consists of the following processes: Flooding, Venting, Hydrotesting, Dewatering, Drying, and N2 Purging. Among these processes, drying and nitrogen purging processes are stipulated to reduce and maintain the relative humidity below dew point to prevent the generation of hydrate and the risk of gas explosion in the pipeline during operation. The purpose of this study is to develop an analysis method for the air drying and nitrogen purging process during pre-commissioning of the subsea pipeline, and to evaluate the applicability of the analysis method through comparison with on-site measurement results. An analysis method using Computational Fluid Dynamics (CFD) was introduced and applied as a method for evaluating the relative humidity inside a subsea pipeline, and it was confirmed that analysis results were in good agreement with the on-site measurement results for the air drying and nitrogen purging process of the offshore pipeline. If the developed air drying and nitrogen purging analysis method are used as pre-engineering tools for pre-commissioning of subsea pipelines in the future, it is expected to have a significant impact on the improvement of work productivity.

Study on Effect of Anchor Bolt by Thermal Expansion of Sulfur Storage Tank under High Temperature (고온을 받는 유황저장탱크의 열팽창에 의한 앵커볼트 영향에 관한 연구)

  • Jung, Wook-Hwan;Kim, Jeong-Soo;Kim, Tae-Min;Kim, Moon-Kyum
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.29 no.5
    • /
    • pp.483-490
    • /
    • 2016
  • In plant industry, sulfur storage tank is made of steel and annular plate is connected with concrete foundation of ring wall type by anchor bolt. Due to keep sulfur at high temperature in tank by coil, sulfur storage tank is expanded larger than another tank stores fluid at room temperature. Generally, structural design of tank foundation is performed analysis with loading of temperature gradient between inner and outer surface, this method can't consider the phenomenon that load is intensively transferred to concrete foundation at anchor bolt. This means that temperature load is underestimated and causes crack of concrete near anchor bolt. In this study, evaluation formula considering temperature load transfer mechanism through anchor bolt is proposed and load acting on concrete foundation is rationally decided. For this purpose, it is analyzed variation of thermal load per various anchor bolt number using finite element model including tank annular plate and anchor bolt. Solution is proposed as specified term combining result of analysis and theoretical solution for evaluating load transferred by anchor bolt. For confirmation of validation of proposed formula, it is applied in design of sulfur storage tank at plant site, it shows that the formula can be practically applied.

The Geochemistry of Copper-bearing Hydrothermal Vein Deposits in Goseong Mining District (Samsan Area), Gyeongsang Basin, Korea (경상분지내 삼산지역 열수동광상에 관한 지화학적 연구)

  • Choi, Sang Hoon;So, Chil Sup;Kweon, Soon Hag;Choi, Kwang Jun
    • Economic and Environmental Geology
    • /
    • v.27 no.2
    • /
    • pp.147-160
    • /
    • 1994
  • Copper-bearing hydrothermal vein mineralization of the Samsan area was deposited in two stages (I and II) of quartz-calcite-sulfide veins which fill fissures in Cretaceous volcanic and sedimentary rocks of the Gyeongsang basin. The major ore minerals, chalcopyrite and sphalerite, together with pyrite, galena, hematite, and minor sulfosalts, occur with epidote and chlorite as gangue minerals in stage I quartz veins. Chlorite geothermometry, fluid inclusion and stable isotope data indicate that copper ore was deposited mainly at temperatures between $330^{\circ}C$ and $280^{\circ}C$ from fluids with salinities between 12 and 3 equiv. wt % NaCl. Evidence of fluid boiling indicates a range of pressures from ${\leq}100$ to 200 bars bars. Within ore stage I there was an apparent decrease in ${\delta}^{34}S$ values of $H_{2}S$ with paragenetic time, from 8.0 to 2.3 per mil. This pattern was likely achieved through progressive increases in activity of oxygen accompanying boiling and mixing. In the early part of the first stage, the high temperature, high salinity fluids gave way to progressively cooler and more dilute fluids of the late parts in the first stage and of the second stage. There is a systematic decrease in calculated ${\delta}^{18}O_{water}$ values with decreasing temperature in the Samsan hydrothermal system, from values of -86 per mil for early portion of stage I through -5.9 per mil for late portion of stage I to -6.3 per mil for stage II. The ${\delta}D$ values of fluid inclusion waters also decrease with paragenetic time from -76 per mil to -86 per mil. These trends combined with mineral paragenesis and fluid inclusion data are interpreted to indicate progressive cooler, more oxidizing meteoric water inundation of an early exchanged meteoric hydrothermal system.

  • PDF

A Study on the Element Technologies in Flame Arrester of End Line (선박의 엔드라인 폭연방지기의 요소기술에 관한 연구)

  • Pham, Minh-Ngoc;Choi, Min-Seon;Kim, Bu-Gi
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.25 no.4
    • /
    • pp.468-475
    • /
    • 2019
  • An end-line flame arrester allows free venting in combination with flame protection for vertical vent applications. End-line flame arresters are employed in various fields, especially in shipping. In flame arresters, springs are essential parts because the spring load and the spring's elasticity determine the hood opening moment. In addition, the spring has to work under a high-temperature condition because of the burning gas flame. Therefore, it is necessary to analyze the mechanical load and elasticity of the spring when the flame starts to appear. Based on simulations of the working process of a specific end-line flame arrester, a thermal and structural analysis of the spring is performed. A three-dimensional model of a burned spring is built using computational fluid dynamics (CFD) simulation. Results of the CFD analysis are input into a finite element method simulation to analyze the spring structure. The research team focused on three cases of spring loads: 43, 93, and 56 kg, correspondingly, at 150 mm of spring deflection. Consequently, the spring load was reduced by 10 kg after 5 min under a $1,000^{\circ}C$ heat condition. The simulation results can be used to predict and estimate the spring's load and elasticity at the burning time variation. Moreover, the obtained outcome can provide the industry with references to optimize the design of the spring as well as that of the flame arrester.

Numerical Analysis of Two-Dimensional Motion of a Freely Falling Circular Cylinder in an Infinite Fluid (무한 유체에서 자유 낙하하는 원형 실린더의 2차원 운동에 관한 수치해석)

  • Namkoong, Kak;Choi, Hyoung-Gwon;Yoo, Jung-Yul
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.6
    • /
    • pp.713-725
    • /
    • 2004
  • The two-dimensional motion of a freely falling circular cylinder in an infinite fluid is investigated numerically using combined formulation. The effect of vortex shedding on the motion of a freely falling cylinder is clearly seen: as the streamwise velocity of the cylinder increases due to gravity, the periodic vortex shedding induces a periodic motion of the cylinder. This motion in turn affects the flow field, which is manifested by the generation of the angular velocity vector of the cylinder parallel to the cross product of the gravitational acceleration vector and the transverse velocity vector of the cylinder. A correlation of St-Re relationship for a freely falling circular cylinder is drawn from the present results. The Strouhal number for a freely falling circular cylinder is found to be smaller than that for a fixed circular cylinder when the two Reynolds numbers based on the streamwise terminal velocity of a freely failing circular cylinder and the free stream velocity of a fixed one are the same. From "thought experiments", it is shown that the transverse motion of the cylinder plays a crucial role in reducing the Strouhal number and has an effect of reducing the Reynolds number from the viewpoint of the pressure coefficient. The mechanism of this reduction in the Strouhal number is revealed by the fact that the freely falling cylinder experiences a smaller lift force than the fixed one due to the transverse motion resulting in the retardation of the vortex shedding.

Analysis on Status and Trends of SIAM Journal Papers using Text Mining (텍스트마이닝 기법을 활용한 미국산업응용수학 학회지의 연구 현황 및 동향 분석)

  • Kim, Sung-Yeun
    • The Journal of the Korea Contents Association
    • /
    • v.20 no.7
    • /
    • pp.212-222
    • /
    • 2020
  • The purpose of this study is to understand the current status and trends of the research studies published by the Society for Industrial and Applied Mathematics which is a leader in the field of industrial mathematics around the world. To perform this purpose, titles and abstracts were collected from 6,255 research articles between 2016 and 2019, and the R program was used to analyze the topic modeling model with LDA techniques and a regression model. As the results of analyses, first, a variety of studies have been studied in the fields of industrial mathematics, such as algebra, discrete mathematics, geometry, topological mathematics, probability and statistics. Second, it was found that the ascending research subjects were fluid mechanics, graph theory, and stochastic differential equations, and the descending research subjects were computational theory and classical geometry. The results of the study, based on the understanding of the overall flows and changes of the intellectual structure in the fields of industrial mathematics, are expected to provide researchers in the field with implications of the future direction of research and how to build an industrial mathematics curriculum that reflects the zeitgeist in the field of education.

A Numerical Study on Plate-Type Heat Exchanger Using One-Dimensional Flow Network Model and Porous-Media Model (1차원 유동 네트워크 모델 및 다공성매질 모델을 이용한 판형 열교환기의 수치적 연구)

  • Park, Jaehyun;Kim, Minsung;Min, June Kee;Ha, Man Yeong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.1
    • /
    • pp.21-28
    • /
    • 2016
  • A typical heat exchanger, found in many industrial sites, is made up of a large number of unitary cells, which causes difficulties when carrying out full-scale three-dimensional numerical simulations of the heat exchanger to analyze the aero-thermal performance. In the present study, a three-dimensional numerical study using a porous media model was carried out to evaluate the performance of the heat exchanger modelled in two different ways : full-scale and simplified. The pressure drop in the air side and gas side along with the overall heat transfer rate were calculated using a porous media model and the results were then compared to results obtained with a one-dimensional flow network model. The comparison between the results for two different geometries obtained using a porous media model and a one-dimensional flow network model shows good agreement between the simplified geometry and the one-dimensional flow network model. The full-scale geometry shows reasonable differences caused by the geometry such as sudden expansion and contraction.

Numerical Study on the Thermal Environment of a Natural Light Based Multi-layered Plant Factory (자연광 기반 적층형 식물공장의 열환경에 대한 수치해석 연구)

  • Park, Dong Yoon;Jang, Seong-Teak;Chang, Seong-Ju
    • KIEAE Journal
    • /
    • v.13 no.5
    • /
    • pp.43-50
    • /
    • 2013
  • Recent researches on plant factory system deal with the convergence of lighting technology, agricultural technology inclusive to the high-tech industries worldwide in order to respond to the decreasing crop harvest due to global warming and abnormal weather phenomena. However, the fundamental performance standard is not currently being introduced in the case of plants factory and its commercialization is not activated because of high initial investment and operating cost. Large portion of the initial investment and operating cost of a plant factory is ascribed to artificial light sources and thermal control facilities, therefore, innovation should be provided in order to improve the economics of the plant factory. As an alternative, new plant factory could harness solar thermal and geothermal systems for heating, cooling and ventilation. In this study, a natural light dependent multi-layer plant factory's thermal environment was analyzed with two-dimensional numerical methods to elicit efficient operation conditions for optimized internal physical environment. Depending on the supply air temperature and airflow rate introduced in the facility, the temperature changes around the crops was interpreted. Since the air supplied into the plant factory does not stay long enough, the ambient temperature predicted around the plating trays was not significantly different from that of the supplied air. However, the changes of airflow rate and air flow pattern could cause difference to the temperature around the planting trays. Increasing the amount of time of air staying around the planting trays could improve energy performance in case the thermal environment of a natural light based multi-layer plant factory is considered.

Computational Thermo-Fluid Analysis for the Effects of Helium Injection Methods on Glass Fiber Cooling Process in an Optical Fiber Manufacturing System (광섬유 냉각장치의 헬륨 주입기 설계를 위한 전산열유동해석)

  • Park, Shin;Kim, Kyoungjin;Kim, Dongjoo;Park, Junyoung;Kwak, Ho Sang
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.13 no.2
    • /
    • pp.124-130
    • /
    • 2014
  • In a mass manufacturing system of optical fibers, the sufficient cooling of glass fibers freshly drawn from a draw furnace is essential, asinadequately cooled glass fibers can lead to poor resin coating on the fiber surface and possibly fiber breakage during the process. In order to improve fiber cooling at a high drawing speed, it is common to use a helium injection into a glass fiber cooling unit in spite of the high cost of the helium supply. The present numerical analysis carried out three-dimensional thermo-fluid computations of the cooling gas flow and heat transfer on moving glass fiber to determine the cooling performance of glass fiber cooling depending on the method of helium injection. The results showed that afront injection of helium is most effective compared to a uniform or rear injection for reducing air entrainment into the unit and thus cooling the glass fibers at a high fiber drawing speed. However, above a certain amount of injected helium, there was no more increase of the cooling effect regardless of the helium injection method.

Natural Convection Heat Transfer with a Rectangular Obstruction in a square Enclosure (직사각형 전도성 장애물을 갖는 밀폐공간내에서의 자연대류)

  • Choo, H.L.;Kim, B.H.;Kim, H.W.;Jang, C.S.
    • Solar Energy
    • /
    • v.18 no.2
    • /
    • pp.123-135
    • /
    • 1998
  • The effect of the thermal conductivity of a centered, square, heat-conducting body on natural convection In a square enclosure was examined numerically. Numerical simulations was carried out for Pr=0.17, $Ra=1.0{\times}10^4,\;1.0{\times}10^5,\;1.0{\times}10^6$, $K^*$=1.0, 6.6, 34.0 and t=0.5, 1.0, 2.0. The results were reported in terms of streamlines, isotherms, Nusselt number. As the results, the mean Nusselt number increases with the increasing of ${\zeta}$ at a constant Ra and $K^*$. In the case of ${\zeta}=1.0$(obstruction shape ratio), the mean Nusselt numbers were decreased as increasing of $K^*$(obstruction thermal conductivity ratio) with regardless of the Rayleigh number. When the constant obstruction size and thermal conductivity ratio, convective heat transfer effect was more enhanced at ${\zeta}=2.0$ than ${\zeta}=0.5$.

  • PDF