• Title/Summary/Keyword: 열유속 분포

Search Result 103, Processing Time 0.028 seconds

Flow Characteristics According to Velocity Conditions of Cylinder Boundary Under Low Reynolds Number (저 레이놀즈 수에서 실린더 경계 유속조건에 따른 흐름 특성)

  • Song, Chang Geun;Seo, Il Won;Kim, Tae Won
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.6
    • /
    • pp.2267-2275
    • /
    • 2013
  • Existing conventional model for analysis of shallow water flow just assumed the internal boundary condition as free-slip, which resulted in the wrong prediction about the velocity, vorticity, water level, shear stress distribution, and time variation of drag and lift force around a structure. In this study, a finite element model that can predict flow characteristics around the structure accurately was developed and internal boundary conditions were generalized as partial slip condition using slip length concept. Laminar flow characteristics behind circular cylinder were analyzed by varying the internal boundary conditions. The simulation results of (1) time variations of longitudinal and transverse velocities, and vorticity; (2) wake length; (3) vortex shedding phenomena by slip length; (4) and mass conservation showed that the vortex shedding had never observed and laminar flow like creeping motion was occurred under free-slip condition. Assignment of partial slip condition changed the velocity distribution on the cylinder surface and influenced the magnitude of the shear stress and the occurrence of vorticity so that the period of vortex shedding was reduced compared with the case of no slip condition. The maximum mass conservation error occurred in the case of no slip condition, which had the value of 0.73%, and there was 0.21 % reduction in the maximum mass conservation error by changing the internal boundary condition from no slip to partial slip condition.

A new formulation for unsteady heat transfer of oscillatory flow in a circular tube (원관내 왕복유동에서 비정상 열전달 관계식의 공식화)

  • Park, Sang-Jin;Lee, Dae-Yeong;No, Seung-Tak
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.9
    • /
    • pp.2953-2964
    • /
    • 1996
  • Heat Transfer with periodic fluctuation of fluid temperature caused by oscillatory flow or compression expansion can be out of phase with balk fluid-wall temperature difference. Newton's law of convection is inadequate to describe this phenomenon. In order to solve this problem the concept of the complex Nusselt number has been introduced by severla researchers. The complex Nusselt number expresses out of phase excellently while the first harmonic is dominant in the variations of both fluid-wall temperature difference and heat flux. However, in the case of oscillatory flow with non-linear wall temperature distribution, the complex Nusselt number is not appropriate to predict the heat transfer phenomena since the higher order harmonic components appear in periodic temperature variation. Analytic solutions to the heat transfer with an sinusoidal well temperature distribution were obtained to investagate the effect of non-linear wall temperature distribution. A new formula considering the thermal boundary layer was suggested based on the solutions. A comparison was also made with the complex Nusselt number. It was verified that the new formula describes well the heat transfer of oscillating flow even if the first harmonic component is not dominant in the fluid-wall temperature difference.

Analytical and Numerical Model Study to Predict the Temperature Distribution Around an Underground Food Cold Storage Pilot Cavern (냉동저장 공동 주변의 온도분포 예측을 위한 해석해 및 수치모델 적용에 관한 연구)

  • 이대혁;김호영
    • Tunnel and Underground Space
    • /
    • v.12 no.3
    • /
    • pp.142-151
    • /
    • 2002
  • Claesson(2001)'s analytical solution, and two numerical models with Dirichlet and Neuman interior boundary condition respectively were investigated to estimate the transient temperature distribution with distances from the Taejon underground food cold storage pilot cavern. Claesson's solution, which is based on constant temperature boundary condition at the rock wall during a temperature decline step, showed relatively good agreement with temperature measurements in the rock mass in order of average error difference, 0.89$\^{C}$ without any adjustments on laboratory thermal properties to represent the rock mass. For the numerical model with heat flux through the rock wall, a boundary condition setting technique was newly proposed to overcome the difficulty of prescribing variable convective heat tranfer coefficient and far-field air temperature inside the cavern as they may be certainly changed according to the cooling-down time. The results showed also good agreement with measurements in order of average error difference, 1.58$\^{C}$, and were compared to those of the numerical model with fixed temperature at the rock wall. Finally, the most proper procedure to precisely predict the temperature profile around a cavern was proposed as a series of analysis steps including an analytical exact solution and numerical models.

The Effects of Winch-curtain Ventilation on the Indoor Environment of a Fattening Swine House (윈치커튼 환기가 비육돈사의 실내 환경에 미치는 영향)

  • Kim, Hyeon-Tae;Song, Jun-Ik;Choi, Hong-Lim
    • Journal of Animal Environmental Science
    • /
    • v.18 no.1
    • /
    • pp.1-8
    • /
    • 2012
  • The study was conducted to investigate the effects of climate on indoor environment of a swine house with natural. This study was tested in the beef swine stall at Young-in, Kyung-ki do. The test was experimented for the effect of interior environment by the outdoor environment and the interior-pan. The results are as follows. 1. In test 1 ($T_{out}$ : $25.7^{\circ}C$, without fan), an indoor air flow pattern was showed that entered from sidewall winch-curtain to went out of a indoor by the ridge winch-curtain. And the velocity of a section of the center was measured two times as large as the velocity of the floor. It is the acceleration of the velocity by thermal buoyancy. And, the entered air was rapidly dissipated by flow energy. So that in the swain livestock with sidewall winch-curtain is effected by thermal buoyancy. And the air temperature of the indoor was distributed more higher as compared with the outdoor temperature. This result is caused by the sensible heat from swine and the ventilation is restricted. 2. In test 2 (($T_{out}$ : $25.7^{\circ}C$, with fan), the velocity of a section of the center was measured more higher as compared with the test 1. And the variance of air velocity was distributed higher as compared with the test 1. This result is showed dead region of air flow with a fan operation. And, the variance of gas density was distributed lower as compared with the test 1.

최적 노심입구온도 분포모형을 이용한 고리 1호기 주증기관 파단사고 분석

  • 엄길섭;이병일;김정진;김희철;박군철
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05b
    • /
    • pp.556-561
    • /
    • 1996
  • 주증기관 파단사고가 발생하여 서로 다른 온도 및 유속을 갖는 냉각재가 원자로 용기에 유입 될 때 downcomer 및 lower plenum 에서의 혼합현상을 3차원 열수력 분석코드 COMMIX-lB[1]로 모사하여 노심입구에서의 온도분포를 결정하고, 결정된 온도분포를 이용하여 주증기관 파단사고에 대한 열적여유도를 분석하였다. 분석은 주증기관 파단사고시 노심입구온도의 비대칭성이 가장 큰 고리 1호기를 선택하여 수행되었으며, 15주기 교체노심 설계 결과와 비교하여 열적 여유도가 다소 증가함을 확인하였다.

  • PDF

Comparative Studies of Heat Transfer Coefficients for Rocket Nozzle (로켓 노즐의 열전달계수 비교 연구)

  • Hahm, Hee-Cheol;Kang, Yoon-Goo
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.16 no.2
    • /
    • pp.42-50
    • /
    • 2012
  • The goal of heat transfer studies is the accurate prediction of temperature and heat flux distribution on material boundaries. To this purpose, general-purpose computational fluid dynamics(CFD) code is used : FLUENT. Mass fluxes and pressure ratio are calculated for two types of nozzle. The comparative studies reveal that the computational results are in agreement with the experimental data. Also, heat transfer coefficients from FLUENT for one type of nozzle are very similar and agree well with the experimental data in the diverging part of the nozzle, but the calculated results are large in the converging part. The heat transfer coefficients from Bartz equation are over-predicted. We can consider various reasons for these differences, i.e., laminarization by the highly accelerated flow in the nozzle, turbulent flow model and grid generation.

MCCI 실험에 대한 검증계산을 통한 MELCOR 코드 평가 및 취약점 도출

  • 이병철;김주열;정창현
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1995.05a
    • /
    • pp.556-561
    • /
    • 1995
  • 원자력발전소 중대사고시 격납건물의 건전성을 위협할 수 있는 현상들 중의 하나인 MCCI에 대한 분석을 목적으로 MCCI 관련 실험인 SWISS 및 SURC 실험에 대하여 MELCOR 1.8.2 를 이용하여 계산을 수행하였다. 에어로졸 생성량을 제외한 MCCI 진행과정의 주요 예측대상에 대하여 실험결과와의 비교를 통하여 콘크리트 침식 진행과정 및 침식을, 노심용융물의 온도분포 및 열유속, 반응에 의해 유출되는 각종 가스 생성을, 그리고 노심용융물의 냉각에 따른 각질층 형성 등을 파악하였다. 콘크리트 침식과정 및 노심용융물의 온도 예측은 적절하며 콘크리트 분해에 따른 각종 방출가스는 열수력 조건에 따라 큰 불확실성을 보여주는 것으로 나타났다. 아울러 노심용융물의 냉각에 따른 각질층의 동적 거동해석은 MELCOR 1.8.2의 모델로서는 불가능하였다. 보다 많은 검증계산을 통하여 적절한 해석방법의 도출 및 새로운 모델 제시의 필요성이 있다고 판단된다.

  • PDF

A Study on the Convective Heat Transfer in the Turbine Cascade for the Free-Stream Turbulence levels (자유흐름 난류 강도 변화에 대한 터빈 블레이드의 대류 열전달에 관한 연구)

  • 심재경;전승배;황민기;임진식
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.42-42
    • /
    • 2000
  • 선형 터빈 익렬에 유입되는 자유흐름 난류 강도의 변화에 따른, 터빈 블레이드에서의 대류 열전달 현상에 대한 연구를 수행하였다. 익렬은 5개의 볼레이드를 선형으로 배치하여 구성하였으며, 현의 길이에 근거한 레이놀즈 수는 2.5${\times}$$10^5$, 3.5${\times}$$10^5$ 이다. 자유 흐름의 난류 강도는 익렬의 도입부에 설치된 격자의 형상에 따라 1.3%, 3.7%, 7.0%, 7.8%의 값을 나타내었다. 자유흐름의 난류강도는 정온 열선유속계로 측정하였으며, 블레이드 표면 온도 분포는 열전대를 사용하여 측정하고, 금속박판을 사용하여 균일한 열유속을 공급하였다.(중략)

  • PDF

A Study on Development of Liquid Cooled Plate for Cooling of a Communication Electronic Device with High Heat Generation (고발열 통신용 전자부품 냉각을 위한 고성능 수냉식 냉각판 개발에 관한 연구)

  • Chang, G.;Park, C.M.;Kim, E.P.
    • Journal of Power System Engineering
    • /
    • v.11 no.2
    • /
    • pp.26-31
    • /
    • 2007
  • 통신용 전자기기에서 대부분의 열은 증폭기에서 발생한다. 일반적으로 증폭기를 냉각하기 위하여 공랭식을 사용하여 발생하는 많은 열을 냉각하였다. 그러나 전통적인 방법은 고성능 콤팩트화 되어가는 추세에서 발열되는 열을 충분히 냉각하기는 부족하다. 본 논문은 고발열 전자부품 냉각을 위해서 수냉식 방법을 사용하였다. 열전달 효율을 높이기 위하여 냉각판에 직접 냉각수를 흐르게하여 접촉저항을 줄였다. 그리고 냉각판의 유로에 대한 배열과 유량의 비의 효과를 조사하였다. 연구를 수행한 결과, 다음과 같은 결론을 얻을 수 있었다. 냉각수 순환량이 $3{\iota}/min$인 경우, 유로 직경이 8 mm일 때의 냉각 성능이 10 mm일 때보다 우수한 것으로 나타났다. 냉각수 순환량이 $3{\iota}/min$인 경우, 유로 직경이 8 mm일 때의 발열 소자 표면 온도 분포가 더욱 안정적으로 나타났으며, 상하부에 설치된 발열 소자 표면 온도가 더 낮게 나타났다. 동일한 유로 직경의 냉각판에서, 열유속 증가에 따른 냉각수의 전열 성능 증가로 인해 전체 발열량의 증가율보다 발열 소자의 온도 증가율이 낮게 나타났다.

  • PDF