• Title/Summary/Keyword: 열원온도

Search Result 352, Processing Time 0.023 seconds

An Experimental Performance Comparison Study of Solar Heat and Power Hybrid Unit Module (태양 열·전기 복합생산 단위 모듈의 실험적 성능비교 연구)

  • Lee, Kwang Seob;Andrew, Putrayudha S.;Kang, Eun Chul;Lee, Euy Joon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.9
    • /
    • pp.757-762
    • /
    • 2014
  • A solar heat and power hybrid system can simultaneously generate electricity and thermal energy. In this study, several experiments were carried out with a solar heat and power hybrid unit. Then, a method to increase the photovoltaic efficiency and amount of thermal energy was suggested based on a comparative analysis. The experiment was conducted using only the photovoltaic system as a reference case, with the photovoltaic-thermal air system as a hybrid case. A numerical increase in the photovoltaic efficiency per $1^{\circ}C$ was suggested based on a comparative data analysis of these two cases. In this experiment, the surface temperature on the air hybrid system was $13.52^{\circ}C$ lower than that in the reference case, and the photovoltaic efficiency was increased by 5.09. The amount of thermal energy produced was 15.69 Wt per $1^{\circ}C$ difference between the ambient and outlet temperatures. In this paper, therefore, a photovoltaic efficiency increase of 0.34 per $1^{\circ}C$ is proposed for the air hybrid system based on the analysis of the experimental data.

Thermal Stress Finite Element Analysis of Iron-manufacturing Furnace Structures (제철용 고로 구조물의 열응력 유한요소 해석)

  • Han Dae-Suk;Paik Jeom-Kee;Lee Jae-Myung;Kim Won-Beom;Lee Man-Seung;Choi Woo-Cheol
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2005.04a
    • /
    • pp.283-290
    • /
    • 2005
  • 제철용 고로구조물의 안전성 위협 요인으로는, 고로자중이나 철광석 낙하 둥과 같은 기계하중 외에도 구조물 내부 온도가 최대 $1700^{\circ}C$에 이르는 고온 환경을 들 수 있다. 이러한 고온의 작업 환경은 고로 구성부재들의 크립손상, 열피로 문제 등을 야기시키기 때문에 이들 고열에 의한 영향평가는 고로의 안전성 평가에 있어 필수요소로 거론되고 있다. 일반적으로 고로의 단면을 구성하고 있는 내화재, 냉각판, 철피 등의 냉각시스템을 거치면서 내부의 고온 환경은 고로 외피에 이르는 동안 온도강하가 이루어진다. 급격한 온도강하는 나타나지 않지만 장기간 고로 가동에 있어 상시하중으로 작용하는 이 열원에 의해 고로 각 구부위에는 열응력이 발생하고 이 열응력과 나머지 기계적 하중의 조합에 의해 크립이나 열피로 등과 같이 고로 구조물 안전성 위해요인들이 발생한다고 분석되어 진다. 따라서 본 연구에서는, 고로 안전성 평가를 위한 첫 번째 단계로서 범용유한요소해석 프로그램인 ANSYS를 이용한 열응력 해석을 수행하여 잠재적인 안전성 위해요인으로 알려진 열응력 발생 특성을 분석하고, 고로 건전설계 및 보수 유지 관리지침으로 활용할 수 있는 기반기술을 개발한다.

  • PDF

Heat efficiency Analysis of PVT module system using CFD (CFD를 이용한 PVT 모듈 열교환기 성능 해석)

  • Kim, Yangjoon;Kim, Dongkwon;Nam, Seungbaek;Cho, Insoo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.112.2-112.2
    • /
    • 2011
  • PVT(Photovoltaic Thermal) 모듈은 태양광과 태양열 에너지를 동시 이용이 가능한 모듈로서 태양광전지(PV, Photovoltaic)모듈에 열교환기를 접합한 형태로 전기에너지뿐만 아니라 열에너지를 동시에 생산할 수 있는 시스템이다. 기존 PV 모듈은 일사량이 많으면 전력 생산량이 증가하는 동시에 PV모듈의 온도가 상승함에 따라 발전 효율이 감소하는 문제점이 있으며 일반적으로 $25^{\circ}C$이상 조건에서 모듈 온도가 $10^{\circ}C$ 증가할수록 발전효율의 약 4~5% 정도 감소하는 것으로 보고되고 있다. PVT 모듈은 기존 태양광모듈에 열교환기를 접합하여 냉각함으로써 PV모듈의 온도를 낮추어 발전효율을 증가시키는 동시에 부가적으로 발생하는 온수를 직접이용하거나 다양한 계통의 보조 열원으로 이용할 수 있는 장점이 있다. 본 연구에서는 수치해석기법(CFD)을 활용하여 PV모듈 냉각 및 온수 발생을 위한 열교환기를 설계하였으며 다양한 형상의 열교환기에 대해 유동해석을 수행하여 최적의 열흡수효율을 갖는 열교환기의 형상을 설계하였다. 또한 최적 설계된 PVT 모듈을 제작하여 실제 태양과 유사한 광원을 갖는 인공태양조건에서의 실내 실험을 통해 PVT 모듈의 성능을 검증하였으며 또한 실제 노상에 설치하여 ASHRAE 93-77의 실험기준과 ECN의 PVT 집열기 성능측정 가이드라인에 따라 옥외 시험평가를 하여 PVT 모듈의 성능 검증을 하였다. 최적 설계된 PVT모듈에 대한 성능평가 결과 기존 PV 모듈보다 발전효율이 약 15%(기존 발전효율 대비) 향상된 결과를 확인하였다.

  • PDF

A study on the required energy of a thermal type desalination plant (증발식 해수담수화설비의 에너지 소모량에 관한 연구)

  • Song, Chi-Sung
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.9
    • /
    • pp.1094-1100
    • /
    • 2014
  • TEvaporator is key component in food, seawater distillation and waste water treatment system, which is basically to concentrate the raw liquid by evaporating the pure water under vacuum condition. The liquid concentration is performed through the membrane, electro-dialysis and evaporation. In this study, only the evaporating type was treated for evaluating the economic analysis with the various operating conditions. The results of this study showed that the performance of the OT-MSF desalination system is increased with decreasing the temperature difference between the neighboring evaporators, which means that the number of evaporators is increased, under the determined design conditions.

A Study on the Operating Characteristics by Counter Flow and Parallel Flow in Separate Heat Pipe Exchanger (분리형 히트파이프식 열교환기에서 향류 및 병류유동에 따른 가동특성에 관한 연구)

  • 이기우;장기창;유성연
    • Journal of Energy Engineering
    • /
    • v.7 no.1
    • /
    • pp.44-56
    • /
    • 1998
  • Separate heat pipe exchanger is considered as the high thermal transportation equipment, because evaporator and condenser are separately positioned in the long distance. Its characteristics are that the working fluid is circulated naturally by the position height of two exchangers. But the operating characteristics are restricted by the temperature of hot and cold fluid, flow pattern and diameter of vapor line, etc. in this study, the vapor pressure and the minimum height of two exchangers are studied about the factors restricting the operating characteristics.

  • PDF

The Effect of Mass Transfer on the Cure Properties of the Urea Resin Moulding Compounds Under the Drying Process (건조 공정 중 요소 수지 성형재료의 경화 특성에 대한 물질전달 효과)

  • Kim, Sang Yeul;Choi, Il Gon;Kim, Byoung Chul
    • Korean Chemical Engineering Research
    • /
    • v.40 no.6
    • /
    • pp.681-686
    • /
    • 2002
  • In the industrial field, the theory of drying process is different from the practical application, and it is effective to reduce energy by recirculation of the heat of exhausting gas. But the study of this field may not be performed still. The cure properties of the urea resin moulding compounds was investigated according to drying temperature, drying time, recycle rate of exhausting gas and moulding temperature in the process of drying and moulding. We obtained the following results; water content of material decreases with increasing drying time and drying temperature, and the rate of drying also decreases with increasing recycle rate of exhausting gas. Specially, The cure fluidity of the urea resin moulding compounds decreases, with increasing drying temperature, recycle rate of exhausting gas and moulding temperature. And the correlation equations on water content and cure fluidity of the urea resin moulding material were obtained through a regression analysis of experimental data.

Temperature Analysis of the Cylindrical Structure with Multi-Holes of HANARO Irradiation Test (하나로 조사시험용 다공 원통헝 구조물의 온도해석)

  • Choi Young-Jin;Kang Young-Hwan;Lee Young-Shin
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.17 no.4
    • /
    • pp.405-412
    • /
    • 2004
  • During the irradiation tests of material and fuel rod, all components of the cylindrical structure with multiple holes act like heat sources due to high gamma heat and fission heat. The objective of this study is to formulate the general solution for the temperature distribution to estimate the thermal integrity of structure during irradiation tests. For the temperature distribution analysis, the two-dimensional heat conduction theory is used. The unmerical analysis is performed by the commercial finite element analysis code, ANSYS 6.1. If the cylindrical structure with hole number would not exceed three holes, the analysis results and finite element results are good agreement together. For the structure with four holes, the discrepancy between FE results and analysis results of the structural temperature distribution is increased.

Numerical Analysis on Consolidation of Soft Clay by Sand Drain with Heat Injection (수치해석을 통한 샌드드레인과 열주입에 의한 연약지반의 압밀 해석)

  • Koy, Channarith;Yune, Chan-Young
    • Journal of the Korean Geotechnical Society
    • /
    • v.33 no.11
    • /
    • pp.45-57
    • /
    • 2017
  • Temperature change affects consolidation behavior of soft clays. The increase of temperature in soft clays induces the increase of pore water pressure. The dissipation of the excess pore water pressure decreases volume and void ratio. Also, the consolidation rate is accelerated by high temperature which induces the decrease of viscosity of pore fluid. The effects of temperature on the consolidation behavior such as consolidation settlement, consolidation time, and pore water pressure were investigated in this study. A numerical analysis of hydro-mechanical (HM) and thermo-hydro-mechanical (THM) behavior was performed. The combination of heat injection and sand drain for consolidating the soft ground, with varying temperature (40 and $60^{\circ}C$) and sand drain diameter (40, 60, and 80 mm), was considered. The results show that the temperature inside soil specimen increases with the increase of the temperature of heating source and the diameter of sand drain. Moreover, the heat injection increases the excess pore water pressure and, accordingly, induces additional settlement in overconsolidated (OC) state and reduces the consolidation time in normally consolidated (NC) state.

Investigation of Structural Reliability on Solder Joint According to Heater Set-point of the Lunar Lander (달 착륙선의 히터 작동온도 설정에 따른 솔더 접합부의 구조적 신뢰성 분석)

  • Jeon, Young-Hyeon;Park, Tae-Yong;Lee, Jang-Joon;Kim, Jung-Hoon;Oh, Hyun-Ung
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.46 no.2
    • /
    • pp.167-174
    • /
    • 2018
  • The heater is applied to the lunar lander for securing its survivability under severe lunar thermal environment during 14 days of night time. For this, the heater on/off set-points shall be determined to minimize the power consumption due to the limited power generation of lunar lander during night time. In addition, the temperature changes of the lander according to the heater set-point is also an important factor because it is related to thermo-mechanical reliability on solder joint of on-board electronics. In this study, we investigated thermo-mechanical reliability on solder joint according to the heater set-point by using commercial reliability and a life prediction tool of Sherlock based on the thermal analysis results of lunar lander that is a year of the mission lifetime.

An Experimental Study on Thermal Prestressing Method for Strengthening Concrete Bridge (콘크리트 교량의 보강을 위한 온도 프리스트레싱 공법의 실험적 연구)

  • Ahn, Jin-Hee;Kim, Jun-Hwan;Choi, Kyu-Tae;Kim, Sang-Hyo
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.4
    • /
    • pp.483-490
    • /
    • 2007
  • Traditional external post-tensioning method using either steel bars or tendons is commonly used as a retrofitting method for concrete bridges. However, the external post-tensioning method has some disadvantages such as stress concentration at anchorages and inefficient load carrying capability regarding live loads. Thermal prestressing method is a newly proposed method for strengthening and rehabilitation of concrete girder bridges. Founded on a simple concept of thermal expansion and contraction of steel, the method is a hybrid method of external post-tensioning and steel plate bonding, combining the merits of two methods. In this paper, basic concepts of the method are presented and an illustrative experiment is introduced. From actual experimental data, the thermal prestressing effect is substantiated and the FEM approach for its analysis is verified.