• Title/Summary/Keyword: 열분석적 특성

Search Result 2,493, Processing Time 0.039 seconds

Preparation of Microparticulate Itraconazole/Hydroxypropyl-$\beta$-cyclodextrin Inclusion Complexes Using a Supercritical Anti-Solvent [SAS] Process (초임계 역용매 공정을 이용한 Itraconazole/Hydroxypropyl-$\beta$-cyclodextrin 포접복합체 미세입자 제조)

  • 이상윤;김정규;김우식;유종훈;임교빈
    • KSBB Journal
    • /
    • v.19 no.4
    • /
    • pp.321-326
    • /
    • 2004
  • Microparticles of an inclusion complex between itraconazole and 2-hydroxypropyl-${\beta}$-cyclodextrin (HP-${\beta}$-CD) were prepared using an environmentally-benign supercritical anti-solvent (SAS) process. In order to evaluate the degree of complexation, the thermal behavior of solid micro particulate complexes was investigated using differential scanning calorimetry. The experimental results obatined for the solubility and dissolution rate of the microparticulate inclusion complexes in a buffer solution of pH 1.2 showed that the complexation of itraconazole with HP-${\beta}$-CD results in a significant increase in the solubility and dissolution rate of itraconazole. For the microparticulate itraconazole/Hp-${\beta}$-CD inclusion complexes prepared by the SAS process, about 80% of itraconazole was found to dissolve in the buffer solution. Our experimental results confirmed that the SAS process is a promising method for the preparation of microparticles of water-insoluble drug/cyclodextrin inclusion complexes.

Characteristics of the flow in the Usan Trough in the East Sea (동해 우산해곡 해수 유동 특성)

  • Baek, Gyu Nam;Seo, Seongbong;Lee, Jae Hak;Hong, Chang Su;Kim, Yun-Bae
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.19 no.2
    • /
    • pp.99-108
    • /
    • 2014
  • One year long time-series current data were obtained at two stations (K1 and K2) located in the Usan Trough in the area north of Ulleungdo in the East Sea from September 2006. The observed data reveal enhanced seafloor flows in both stations with variabilities of about 20 days which is possibly governed by the topographic Rossby wave. After February 2007, strong flow in the upper layer in St. K1 appears throughout the mooring period and this is due to the passage of the warm eddy comparing with satellite sea surface temperature data. During this period, no significant correlation between the current in the upper layer and those in two deep layers is shown indicating the eddy does not affect flows in the deep ocean. It is also observed that the flow direction rotates clockwise with depth in both stations except for the upper of the K1. This implies that the deep flow does not parallel to the isobaths exactly and it has a downwelling velocity component. The possibility of the flow from the Japan Basin to the Ulleung Basin across the Usan Trough is not evidenced from the data.

Characterization of Phytase from Bacillus coagulans IDCC 1201 (Bacillus coagulans IDCC 1201이 생산하는 Phytase의 특성)

  • Lee Seung-Hun;Kwon Hyuk-Sang;Koo Kyo-Tan;Kang Byung-Hwa;Kim Tae-Yong
    • Microbiology and Biotechnology Letters
    • /
    • v.34 no.1
    • /
    • pp.28-34
    • /
    • 2006
  • A native extracellular acid phosphatase, phytase (EC 3.1.3.8), from Bacillus coagulans IDCC 1201 (commercially known as Lactobacillus sporogenes) used as probiotics, was characterized. Though some strains of B. coagulans have been evaluated with regard to several health-promoting effects, it has not been reported to produce phytase. Partially purified phytase front the strain IDCC 1201 had a pH optimum of 4.0 and a temperature optimum of $50^{\circ}C$, respectively. The requirement for divalent cations was studied and cobalt ion remarkably increased the enzyme activity. The removal of metal ions from the enzyme by EDTA decreased activity below 50%. The enzyme activity depleted restored when the assay was performed in the presence of $Co^{2+}$. Also, $Co^{2+}$ is the most active stimulator and has unique activation effect at high temperature. The phytase was specific for sodium phytate and p-nitrophenylphosphate, which is different from other known Bacilli phytases. The putative amino acid sequences of the phytase from B. coagulans IDCC 1201 were very similar to that of the phytase from B. subtilis strain 168. Based on these data, we concluded that the phytase from B. coagulans IDCC 1201 is a $Co^{2+}$-dependent acid phosphatase. Therefore, the strain B. coagulans IDCC 1201 is thought to be a valuable addititive for livestocks as well as a beneficial probiotics for human.

Production and Characterization of Thermo-alkalotolerant Cyclodextrin Glucanotransferase from Thermo-alkalophilic Bacillus cereus B-13 (고온성이며 호알칼리성인 Bacillus cereus B-13으로부터 내열성, 호알카리성 Cyclodextrin Glucanotransferase의 생산과 특성)

  • Seo, Seung-Bo;Kim, Jae-Ho;Lee, Dae-Hyong;Lee, Jong-Soo
    • The Journal of Natural Sciences
    • /
    • v.16 no.1
    • /
    • pp.15-29
    • /
    • 2005
  • To produce a thermostable cyclodextrin by using thermotolerant cyclomaltodextrin glucanotransferase(CGTase), a thermophilic and alkalophilic bacterium isolate, designated B-13 showing the highest CGTase activity was isalated from natural sources and identified as Bacillus cereus B-13 based on the morphological and physiological characteristics, and 16S rRNA sequence. The maximal CGTase activity (130 U/ml) was obtained when Bacillus cereus B-13 was cultured in SYC medium containing 2.0% soluble starch, 1.0% yeast extracts, 1% corn steep liquor and 1% $Na_2CO_3$ (pH 8.5) at $50^{\circ}C$ for 24 h and about 80% of maximal activity was also showed in he culture broth of $60^{\circ}C$ for 18 h. Optimum reaction temperature and pH of the partial purified CGTase for soluble starch were $65^{\circ}C$ and pH 8.5-9.0 respectively. The partial purified CGTase were also stable below $80^{\circ}C$ and pH 5.0-10.0. When 1% soluble starch was digested with the partial purified CGTase, the yield of cyclodextrin was 49%.

  • PDF

Quality characteristics of frozen brown rice Jeung-pyun dough containing different amounts of acorn flour (도토리가루의 첨가량을 달리하여 제조한 냉동 현미증편반죽의 품질특성)

  • Jeong, Sang-Yeol;Lee, Min-Kyoung;Gwag, Jung Soon;Lee, Sook-Young
    • Food Science and Preservation
    • /
    • v.23 no.3
    • /
    • pp.445-452
    • /
    • 2016
  • In this study, physicochemical properties of acorn flour was investigated, and characteristics of the Jeung-pyun dough added with the acorn flour at various concentrations were evaluated after storage at -$18^{\circ}C$ for 4 weeks and fermentation. Total polyphenolic content, electron donating ability (EDA) of 0.5%, gelatinization onset temperature (To), gelatinization peak temperature (Tp), and gelatinization conclusion temperature (Tc) of acorn flour were 3,525.12 mg%, 16.71%, $68.41^{\circ}C$, $73.83^{\circ}C$, and $82.96^{\circ}C$, respectively. These all values were increased in the Jeung-pyun dough possibly due to addition of the acorn flour. The yeast count was not affected by the addition levels of acorn flour and the frozen storage period before fermentation. The amount of carbon dioxide gas evolved from Jeung-pyun dough during fermentation was significantly changed with the concentration of acorn flour, but it was negligible. The Jeung-pyun added with 6% acorn flour showed an small increase in the amount of carbon dioxide after frozen storage of 1 wk and fermentation. The pH of the fermented Jeung-pyun samples decreased along with the increasing storage period as well as the increasing acorn flour content, ranging from 4.21 to 5.34. Therefore, the frozen Jeung-pyun dough containing 6~15% of acorn flour and stored for 3 weeks was the most desirable among all the tested samples in this study.

A Numerical Study of the Effects of Heat Transfer and Fluid Flow on Tube Insertion Length in Computer-Cooling Radiators (컴퓨터 CPU 냉각용 방열기 튜브 삽입길이에 따른 열유동 해석)

  • Choi, Jin-Tae;Kwon, Oh-Kyung;Yun, Jae-Ho;Kim, Yong-Chan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.2
    • /
    • pp.145-152
    • /
    • 2011
  • The performance of flat-tube radiators with louvered fins was numerically investigated for different tube insertion lengths. The results of numerical analysis using CFX-11 were compared with experimental results. In this study, three types of flat-tube radiators with louvered fins were considered. An experiment was conducted to validate the numerical results. Flow rate ratio (FR) and Stotal were introduced to understand the uniformity of flow distribution easily. The results of numerical analysis revealed that the heat transfer rate and pressure drop increased as the mass flow rate increased. Further, the results showed that the heat transfer rate of sample 3 with h/D = 0.5 was higher than that of the other samples. The pressure drop increased as the insertion length toward the header part increased, and the pressure drop in the case of sample 3 appeared to be the highest. The factor Stotal showed that the uniformity of the flow distribution in the case of sample 1 with h/D = 0 was higher than that in the case of the other samples.

A Study on Anisotropic Compression Behavior of Illite (일라이트의 비등방적 압축특성 연구)

  • Yun, Seohee;Lee, Yongjae
    • Korean Journal of Mineralogy and Petrology
    • /
    • v.33 no.1
    • /
    • pp.11-18
    • /
    • 2020
  • High-pressure synchrotron X-ray powder diffraction experiments were performed on natural illite (K0.65Al2(Al0.65Si3.35)O10(OH)2) using diamond anvil cell (DAC) under two different pressure transmitting media (PTM), i.e., water and ME41 (methanol:ethanol = 4:1 by volume). When using water as PTM, occasional heating was applied up to about 250℃ while reaching pressure up to 2.7 GPa in order to promote both hydrostatic conditions and intercalation of water molecules into the layer. When using ME41, pressure was reached up to 6.9 GPa at room temperature. Under these conditions, illite did not show any expansion of interlayer distance or phase transitions. Pressure-volume data were used to derive bulk moduli (K0) of 45(3) GPa under water and 51(3) GPa under ME41 PTM. indicating no difference in compressibility within the analytical error. Linear compressibilities were then calculated to be βa = 0.0025, βb = 0.0029, βc = 0.0144 under ME41 PTM showing the c-axis is ca. six times more compressible than a- and b-axes. These elastic behaviors of illite were compared to muscovite, one of its structural analogues.

Preparation and Characteristics of Liquid Silicone Rubber Using Polyorganosiloxane Modified with Dimethylacrylamide (디메틸아크릴아마이드 변성 폴리오가노실록산을 이용한 액상 실리콘 고무의 제조와 그 특성)

  • 강두환;이병철
    • Polymer(Korea)
    • /
    • v.28 no.2
    • /
    • pp.143-148
    • /
    • 2004
  • ${\alpha}$,$\omega$-Hydrogen polyorganosiloxane(HPMDMS) prepolymer was prepared from equilibrium polymerization ofoctamethylcyclotetrasiloxane, 1,3,5-trimethylcyclotrisiloxane, 1,3,5,7-tetravinyl-1,3,5,7-tetramethyl-cyclotetrasiloxane, and 1,1,3,3-tetramethyl disiloxane as an end-blocker in the presence of tetramethylammonium siloxanolate as a catalyst. Polyorganosiloxane modified with dimethylacrylamide(APMDMS) was prepared by hydrosilylation of HPMDMS with dimethylacrylamide in the presence of Pt catalyst, and followed by coordination of metal oxide (APMDMS-MO), such as NiO and FeO, to the amide moieties of the resulting polymer. The chemical structures of HPMDMS and APMDMS were confirmed by FT-IR and $^1$H-NMR analysis. Liquid silicone rubber containing metal oxide composite (LSRMO) was prepared by compounding APMDMS-MO, ${\alpha}$,$\omega$-vinylpolydimethylsiloxane, and a catalyst in a high speed dissolver. The thermal conductivity of LSRMO composite was determined to be 0.29 W/mK, and the volume resistivity exhibited a lower value than that of LSR composite. The mechanical and thermal properties of LSRMO and LSR composite were measured by UTM and TGA.

Investigation of Hydraulic Flow Properties around the Mouths of Deep Intake and Discharge Structures at Nuclear Power Plant by Numerical Model (수치모의를 통한 원자력 발전소 심층 취·배수 구조물 유·출입구 주변에서의 수리학적 흐름특성 고찰)

  • Lee, Sang Hwa;Yi, Sung Myeon;Park, Byong Jun;Lee, Han Seung
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.2A
    • /
    • pp.123-130
    • /
    • 2012
  • A cooling system is indispensable for the fossil and nuclear power plants which produce electricity by rotating the turbines with hot steam. A cycle of the typical cooling system includes pumping of seawater at the intake pump house, exchange of heat at the condenser, and discharge of hot water to the sea. The cooling type of the nuclear power plants in Korea recently evolves from the conventional surface intake/discharge systems to the submerged intake/discharge systems that minimize effectively an intake temperature rise of the existing plants and that are beneficial to the marine environment by reducing the high temperature region with an intensive dilution due to a high velocity jet and density differential at the mixing zone. It is highly anticipated that the future nuclear power plants in Korea will accommodate the submerged cooling system in credit of supplying the lower temperature water in the summer season. This study investigates the approach flow patterns at the velocity caps and discharge flow patterns from diffusers using the 3-D computational fluid dynamics code of $FLOW-3D^{(R)}$. The approach flow test has been conducted at the velocity caps with and without a cap. The discharge flow from the diffuser was simulated for the single-port diffuser and multi-ports diffuser. The flow characteristics to the velocity cap with a cap demonstrate that fish entrainment can significantly be minimized on account of the low vertical flow component around the cap. The flow pattern around the diffuser is well agreed with the schematic diagram by Jirka and Harleman.

Characteristics of Aquifer System and Change of Groundwater Level due to Earthquake in the Western Half of Jeju Island (제주도 서반부의 대수층 체계와 지진에 의한 지하수위 변동 특성)

  • Ok, Soon-Il;Hamm, Se-Yeong;Kim, Bong-Sang;Cheong, Jae-Yeol;Woo, Nam-Chil;Lee, Soo-Hyoung;Koh, Gi-Won;Park, Yun-Seok
    • Economic and Environmental Geology
    • /
    • v.43 no.4
    • /
    • pp.359-369
    • /
    • 2010
  • This study characterizes aquifer system and hydrogeologic property in the western half of Jeju Island where wells were drilled for regional water supply in three sub-areas (northwestern, western, and southwestern sub-areas). The aquifer system of the northwestern sub-area is largely composed of upper high-permeability layer, upper low-permeability layer, lower high-permeability layer, and lower low-permeability layer. On the other hand, the aquifer systems of the western and southwestern sub-areas are mostly composed of upper low-permeability layer, high-permeability layer, and lower low-permeability layer. Transmissivity and specific capacity decrease in the order of the northwestern, western, and southwestern sub-areas. The relationship between specific capacity and the top surface of tuff is negative with a high correlation coefficient of -0.848, indicating that the tuff acts as the bottom of the aquifer. Groundwater level change due to the 2004 Sumatra earthquake is an average of 23.74 cm in the northwestern sub-area, an average of 9.48 cm in the western sub-area, and none in the southwestern sub-area. Further, it is found that groundwater change due to the earthquake has a positive relationship with transmissivity and specific capacity.