Design and Performance Evaluation of Dimpled EGR Cooler (딤플형 EGR 냉각기의 설계 및 성능평가)

  • Seo, Young-Ho;Lee, Hyun-Min;Heo, Seong-Chan;Ku, Tae-Wan;Song, Woo-Jin;Kang, Beom-Soo;Kim, Jeong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.3
    • /
    • pp.291-298
    • /
    • 2010
  • A conventional EGR cooler, which is used in an EGR system of an automobile diesel engine, has a low heat-exchange efficiency. To maximize the heat transfer between the exhaust gas and coolant, dimples are formed on the surface of heat exchange tubes. When designing the dimpled EGR cooler, the net heat transfer areas in the conventional and dimpled tube-type EGR coolers are compared. Structural integrity evaluations are also performed by combining finite element analysis with a homogenization method. Subsequently, the process of manufacturing the dimpled tube, i.e., the formation of dimples, edge bending, center v-notch bending, compression, and plasma welding, is established and carried out. Thus, the dimpled EGR cooler is developed, and its performance is verified.

Optimization of Heat Exchange Network of SOFC Cogeneration System Based on Agricultural By-products (농산부산물 기반 SOFC 열병합발전 시스템 열교환망 최적화)

  • Gi Hoon Hong;Sunghyun Uhm;Hyungjune Jung;Sungwon Hwang
    • Journal of the Korean Institute of Gas
    • /
    • v.28 no.1
    • /
    • pp.1-10
    • /
    • 2024
  • In this study, we constructed a process simulation model for an agricultural by-products based Solid Oxide Fuel Cell (SOFC) combined heat and power generation system as part of the introduction of technology for energy self-sufficiency in the agricultural sector. The aim was to reduce the burden of increasing fuel and electricity consumption due to rapid fluctuations in international oil prices and the expansion of smart farming in domestic farms, while contributing to the national greenhouse gas reduction goals. Based on the experimental results of 0.3 ton/day torrefied agricultural by-product gasification experiment, a model for an agricultural by-product-based SOFC cogeneration system was constructed, and optimization of the heat exchange network was conducted for SOFC capacities ranging from 4 to 20 kW. The results indicated that an 8 kW agricultural by-product-based SOFC cogeneration system was optimal under the current system conditions. It is anticipated that these research findings can serve as foundational data for future commercial facility design.

A Study on the Formation of Fouling in a Heat Exchanging System for River Water (하천수를 이용하는 열교환 시스템 내 파울링 형성에 관한 연구)

  • Sung, Sun-Kyung;Suh, Sang-Ho;Roh, Hyung-Woon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.6
    • /
    • pp.646-651
    • /
    • 2004
  • When the water flowing inside of the heat transfer equipments such as heat exchangers, condensers, and boilers is heated, calcium, magnesium sulfate, and other minerals in the water are deposited and built up for scales on the heat transfer surfaces. When those scales accumulate on the heat transfer surfaces, their performance of the heat transfer become progressively reduced due to the increase of the heat transfer resistance. The mechanism of this reduced heat transfer is called fouling. This study investigated the formation of the fouling in a heat exchanger with river and tap water flowed inside of it as a coolant. In order to visualize the formation of the fouling and to measure the fouling coefficients, a lab-scale heat exchanging system was used. Based on the experimental results, it was found that the formation of fouling for river water was quite different with the formation for tap water.

Operating Characteristics of Ammonia-Water Absorber Heat Exchange Cycle (암모니아-물 흡수식 열교환 사이클의 운전 특성)

  • 강인석;김남진;김종보
    • Journal of Energy Engineering
    • /
    • v.10 no.4
    • /
    • pp.357-362
    • /
    • 2001
  • A bench type ammonia-water absorber heat exchange cycle was tested by varying the system charging concentration, refrigerating valve opening and weak solution flow rate. It was observed that the cooling capacity was increased as the system charging concentration was increased. Optimum system charging concentration was found for the coolong capacity of the system. The opening rate of refrigerant expansion valve had a direct influence on the refrigerant sub-cooling at the condenser outlet. Optimum sub-cooling was found to be 0~4$^{\circ}C$. As the weak solution flow rate increased the concentration of strong solution and the evaporating pressure decreased. There existed a optimum weak solution flow rate which maximized the cooling capacity and COP.

  • PDF

Mechanical Properties of Heat Exchanger Element with Higher Capacity Waste Heat Recovery PDC Clean Ventilation System (대용량 폐열회수 PDC청정 환기시스템용 열교환 소자의 기계적 특성)

  • Ahn, S.H.;Nam, K.W.;Ahn, B.H.;Kim, D.G.;Jeong, S.K.
    • Journal of Power System Engineering
    • /
    • v.13 no.5
    • /
    • pp.67-75
    • /
    • 2009
  • Recently, the higher capacity waste heat recovery PDC clean ventilation system has a tendency which is increasing due to the excellent energy reduction in factory, big building, and so on. This system was developed to complement the room environment which is deteriorated. However, the researches and technologies about this system were not well studied. Specially, the characteristic for heat exchanger element used to this system were not well known. Therefore, this study was carried out to evaluate the mechanical properties of the heat exchanger element as the core parts compose of this system. From results, tensile strength and elongation of the plate type heat exchanger element had about 10.11~14.32 kgf/$mm^2$ and 8.0~16.2%, respectively.

  • PDF

Study on Exhaust Air Heat Transfer Characteristics of Heat Exchange System for White Smoke Reduction (백연 저감을 위한 열교환 시스템의 배기 열전달 특성에 관한 연구)

  • Wang, Zhen-Huan;Chun, Chong-Keun;Kwon, Young-Chul
    • Journal of the Korean Society of Mechanical Technology
    • /
    • v.20 no.6
    • /
    • pp.739-744
    • /
    • 2018
  • In this study, effects of reducing white smoke at a heat exchange system for white smoke reduction were studied in the winter season. For this purpose, the heat transfer processes on the exhaust air were investigated by Solidworks. Five wave heat exchangers of air-to-air and air-to-water type were applied for the exhaust air heat recovery. The analytical condition of the exhaust air was fixed and the computational analysis was performed according to the change of SA(supply air) inlet velocities. In order to evaluate the performance of the heat exchange system for white smoke reduction, W(water)/SA recovered capacities and the temperature/absolute humidity reduction rate were calculated. As SA inlet velocity increased, the exit temperature and absolute humidity of the mixing zone were reduced by up to about $40^{\circ}C$ and 0.12kg/kg respectively. Also, W/SA recovered capacities increased linearly up to about 35%.

Design of adsorption bed for Compact $H_2$ PSA process (Compact $H_2$ PSA 공정을 위한 흡착탑의 설계)

  • Lee, Jang-Jae;Lee, Sang-Jin;Moon, Jong-Ho;Choi, Dae-Ki;Lee, Chang-Ha
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.5-8
    • /
    • 2006
  • 수소 station에서 수소분리정제를 위한 compact형 PSA 공정 설계를 위하여 활성탄으로 충진된 dual bed의 흡착동특성을 연구하였다. 기존 PSA 공정의 흡착탑이 차지하는 시스템의 공간을 줄이기 위하여 하나의 흡착탑 안에 다른 흡착탑을 넣어 흡착탑이 차지하는 공간을 최소화하고, 흡착탑 간의 열교환을 효과적으로 할 수 있도록 고안하였다. 수소 혼합물에 대한 dual bed에서의 흡착, 탈착 실험 실시하였으며, 시간에 따른 농도와 온도의 변화를 측정하였다. 수소 혼합물로는 $H_2/CO/CH_4/CO_2$ (69:2:3:26vol.%)를 사용하였으며, 흡착유량은 7LPM, 흡착압력은 9atm 조건에서 운전하였다. Inner bed와 outer bed의 수소 농도 파과곡선의 형태에 있어 차이를 보였으며, 이는 각 탑에서 열교환 효과로 인한 내부 온도 차이에 기인하여 발생하였다.

  • PDF

미세외란과 상관관계를 이용한 조립자동화

  • 이수용
    • ICROS
    • /
    • v.3 no.5
    • /
    • pp.12-16
    • /
    • 1997
  • 조립 작업시 사람이 이용하는 방법을 수학적으로 구현한 미세외란/상관관계에 기초하여, 이의 기본 원리와 응용에 대하여 살펴보았다. 이 방법의 가장 큰 특징은 기존의 이치 제어기에 외부 궤환 제어기를 첨가함으로써 힘에 의하여 안내되는 제어기로 구조를 개선할 수 있다는 점이다. 이러한 제어기를 갖는 로봇을 열 교환기 조립작업에 응용한 예를 들었으며, 로봇을 이용한 다른 조립 작업에도 매우 유용하게 사용될 수 있으리라 생각된다.

  • PDF