• 제목/요약/키워드: 열교환기 설계

검색결과 375건 처리시간 0.024초

오프셋 스트립 휜을 가지는 리큐퍼레이터의 내부 형상 최적화 (Optimization for the Internal Structure of a Recuperator with Offset Strip Fins)

  • 도규형;한용식;최병일;김명배
    • 한국군사과학기술학회지
    • /
    • 제14권6호
    • /
    • pp.1178-1185
    • /
    • 2011
  • In the present study, a recuperator is suggested to improve the thermal efficiency of a micro gas turbine. Primary design parameters of the recuperator are determined from the ideal cycle analysis. The counter flow plate-fin heat exchanger with offset strip fins is chosen as the type of the recuperator. In order to satisfy the design constraints which are the minimum effectiveness and the maximum pressure drop, the optimization for the internal structure of the recuperator is performed with varying the fin spacing and the fin height of offset strip fins. Also the effects of the thermal conductivity of fins and separation plates and the longitudinal heat conduction on the thermal performance of the recuperator are investigated.

연구원_2015 연구과제 1 - 기계설비건설업 동향 분석을 위한 기초연구

  • 이영준;김미리;안미소
    • 월간 기계설비
    • /
    • 통권307호
    • /
    • pp.87-92
    • /
    • 2016
  • 대한기계설비산업연구원(원장 이언구)은 지난해 4월 연구심의위원회에서 선정된 ${\triangle}$기계설비건설업 동향분석 ${\triangle}$기계설비건설업체의 부도예측 모형 연구 ${\triangle}$기계설비건설공사 시공상세도면 작성비 산정기준 연구 ${\triangle}$플랜트 건설 현장 외국인력 고용 개선방안 ${\triangle}$녹색기술 기준에 근거한 연구과제 도출을 위한 기초연구 ${\triangle}$대용량 지열설비 이용을 위한 지중열교환기 용량 설계 툴 개발 ${\triangle}$기계설비배관 및 장비 단열 기준 연구 등의 기본과제와 외부기관과 공동으로 수행한 ${\triangle}$플랜트 건설현장 외국인력 고용 개선방안 ${\triangle}$기계설비건설업 관련법류 개선방안 연구를 추진했다. 본지는 연구결과에 대한 요약 보고서를 연재한다.

  • PDF

SQUID 냉각장치용 극저온 시스템 개발 (Research of Cryogenic Helium Refrigerator System for SQUID)

  • 이금배;백일현
    • 대한설비공학회지:설비저널
    • /
    • 제18권2호
    • /
    • pp.121-129
    • /
    • 1989
  • 헬륨을 이용한 극저온 냉동기는 압축기(compressor)을 통하여 압력을 10-20 기압 정도로 높혀준후 여러 단계의 열교환기(heat exchanger)를 통하여 상전위온도(maximum inversion temperature) 이하로 떨어뜨린후 Joule-Thomson 밸브를 통하면 4K까지 온도가 떨어진다. 이때 압력은 1기압 정도이며 헬륨가스는 액체로 변한다. 본 연구의 목적은 Gifford-McMahon 냉동기와 Joule-Thomson 냉동기의 혼합형인 극저온 냉동기를 설계, 제작하여 죠셉슨(Josephson) 소자를 이용한 SQUID(초전도양자 간섭장치), 여러 종류의 탐지기, 컴퓨터 소자 개발 등을 위한 냉동기로 사용하는데 그 목적이 있다. 개발되는 법동기의 용량은 1 W이며, 최저온도는 4K 정도가 된다.

  • PDF

학교 건물용 지열 히트펌프 시스템 설계와 지중 순환수 온도 변화 분석 (Design of Ground-Coupled Heat Pump (GCHP) System and Analysis of Ground Source Temperature Variation for School Building)

  • 손병후
    • 한국지열·수열에너지학회논문집
    • /
    • 제16권1호
    • /
    • pp.17-25
    • /
    • 2020
  • Ground-coupled heat pump (GCHP) systems have become an efficient alternative to conventional cooling and heating methods due to their higher energy using efficiency. Although some experimental and simulation works related to performance analysis of GCHP systems for commercial buildings have been done, relatively little has been reported on the performance evaluation of GCHP systems for school buildings. The purpose of this simulation study is to evaluate the performance of a hypothetical GCHP system for a school building in Seoul. We collected various data of building specifications and construction materials for the building and then modeled to calculate hourly building loads with SketchuUp and TRNSYS V17. In addition, we used GLD (Ground Loop Design) V2016, a GCHP system design and simulation software, to design the GCHP system for the building and to simulate temperature of circulating water in ground heat exchanger. The variation of entering source temperature (EST) into the system was calculated with different prediction time and then each result was compared. For 20 years of prediction time, EST for baseline design (Case A) based on the hourly simulation results were outranged from the design criteria.

공작기계 절삭유 냉각용 오일쿨러 설계 자동화 (Oil Cooler Design Automation on the Cooling of Machine Tool Cutting Oil)

  • 권혁홍
    • 한국생산제조학회지
    • /
    • 제8권1호
    • /
    • pp.89-99
    • /
    • 1999
  • The automatic design of shell & tube type oil cooler can be used in real industrial environments. Since the automatic design system is intended to be used in small companies, it is designed to be operated well under environments of CAD package in the personal computer. It has adopted GUI in design system, and has employed DCl language. Design parameters to be considered in the design stage of shell and tube type oil cooler are type of oil cooler, outer diameter, thickness, length of tube, tube arrangement, tube pitch, flow rate, inlet and outlet temperature, physical properties, premissive pressure loss on both sides, type of baffle plate, baffle plate cutting ratio, clearance between baffle plate outer diameter and shell inner diameter and clearance between baffle plate holes. As a result, the automatic design system of shell & tube type oil cooler is constructed by the environment of CAD software using LISP. We have built database of design data for various kinds of shell & tube type oil coolers. The automatic design system have been assessed and compared with existing specification of design. Good agreement with Handbook of heat exchanger and design dta of real industrial environments has been found.

  • PDF

MCFC용 가습기 및 HRU의 열전달 특성 연구 (A Study on Heat Transfer Characteristics of Humidifier/HRU for MCFC)

  • 박성호;갈한주;정영식;이상훈;이재준;오용민;김선화
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 춘계학술대회 초록집
    • /
    • pp.97.2-97.2
    • /
    • 2011
  • 본 연구는 연료전지 중 용융탄산염을 전해질로 하는 MCFC의 MBOP에 포함된 부품으로 매우 중요한 역할을 하는 가습기와 이때 발생되는 폐열을 회수하기 위한 장치인 HRU에 관한 것이다. 가습기는 연료와 물이 가습기 상부로 유입되어 가습기 하부로 유입되는 배가스와 열교환을 하면서 물이 스팀화 되어 연료가 가습된 상태로 가습기 출구로 일정온도를 유지하며 배출된다. 또한 HRU는 가습기에서 배출된 고온의 배가스를 물을 이용하여 열교환을 통해서 열을 회수하여 난방 및 온수로 사용할 수 있는 열교환 장치를 말한다. 먼저 이들의 특성을 파악하기 위해 가습기 및 HRU를 설계, 제작하여 각각의 특성을 확인하였다. 가습기와 HRU의 성능 향상을 위해 먼저 열교환부에 적용될 튜브의 수치해석적 분석을 통해서 최적의 열전달 성능을 얻을 수 있는 가습기 및 HRU를 설계, 제작하였으며 이들의 성능을 파악하기 위해 120,000kcal/h 용량을 테스트 할 수 있는 장치를 구축하여, 이들의 열전달 특성, 압력강하, 회수 열량, 가습기 온도 등의 특성을 파악하였다. 이 장치를 통해서 확인된 가습기와 HRU의 특성은 수치해석을 통해서 얻은 값과 거의 유사함을 확인할 수 있었으며, 가습 성능도 효과적으로 달성할 수 있었다. 가습기와 HRU의 특성 중 압력강하 부분은 지속적인 연구가 필요한 부분이며, 가습기와 HRU의 일체화를 통하여 소형화 및 설치공간 축소 효과를 얻을 것으로 본다.

  • PDF

小規模 太陽熱 給湯시스템 의 最適設計 에 관한 硏究 (A Study on the Optimum Design for a Solar Domestic Hot Water System)

  • 서정일;이영수
    • 대한기계학회논문집
    • /
    • 제8권6호
    • /
    • pp.517-525
    • /
    • 1984
  • 본 연구에서는 2개의 축적탱크와 외부 열교환기로 구성된 가정용 태양열 급탕 시스템을 시뮬레이션 모델로 이론적인 해석을 하고 설계인자들의 값들을 변화시킴으로 써 각각의 성능을 계산할 수 있었다. 또 이 성능 계산치에 의하여 최적설계 인자치 들을 구할 수 있었다. 또한 1983년 1년간 서울지방의 매 시간 일분량과 기온을 사용 하였다.

MVR해수담수화플랜트의 개발 및 성능에 관한 연구 (A study on the development of MVR desalination plant and its performance analysis)

  • 김영민;천원기;김동국
    • 에너지공학
    • /
    • 제25권3호
    • /
    • pp.59-65
    • /
    • 2016
  • MVR 증발법은 담수의 증발을 위해 연료를 지속적으로 연소시켜 나오는 열에너지를 이용하지 않고 대신 전기압축기를 통해 증발된 증기를 압축시켜 고온으로 만들고, 이를 다시 열교환기를 통해 재활용함으로써 에너지의 소비를 최소화하는 방식이다. MVR 증발법은 안정적이라 할 수 있는 계통선에 의해 공급되는 전기 대신 가변적인 풍력에너지를 그 에너지원으로 활용하여 담수 생산을 꾀할 수 있다. 본 연구에서는 일일 담수 생산량이 30 톤인 제주 MVR 담수화 시스템의 설계, 제작 그리고 작동 과정에 대하여 살펴보고자 하였다. 실험결과, MVR 압축비는 1.5 이상이며 주열교환기의 온도차는 $5{\sim}7^{\circ}C$로 설계치와 동일한 성능을 보여준다.

옵셋 스트립 휜 최적 설계 (Optimum Design of Offset-Strip Fins)

  • 김민수;이관수
    • 대한기계학회논문집B
    • /
    • 제34권5호
    • /
    • pp.531-537
    • /
    • 2010
  • 본 연구에서는 옵셋 스트립 휜 열교환기에서 휜 형상에 대한 최적화를 수행하였다. 압력강하량은 감소시키고 열전달량을 증가시키기 위해 이 둘을 동시에 나타낼 수 있는 j/f, $j/f^{1/3}$, JF 등의 성능 인자가 고려되었다. STDQAO, PQRSM, MGA 등의 최적화 기법이 사용되었으며, MGA 를 통해 기존 옵셋 스트립 휜보다 JF 인자는 36%, 열전달 성능은 280% 향상된 최적화된 휜 형상을 제안하였다.

히트싱크를 이용한 전자통신 시스템의 방열설계 프로그램 개발 (Development of Thermal Design Program for an Electronic Telecommunication System Using Heat Sink)

  • 이정환;김종만;전지환;배철호;서명원
    • 대한기계학회논문집B
    • /
    • 제31권3호
    • /
    • pp.256-263
    • /
    • 2007
  • The purpose of this study is to investigate the cooling performance of heat sinks for an electronic telecommunication system by adequate natural convection. Heat generation rates of electronic components and the temperature distributions of heat sinks and surrounding air are analyzed experimentally and numerically. In order to perform the heat transfer analysis for the thermal design of telecommunication system a program is developed. The program used the graphic user interface environment to determine the arrangement of heat sources, interior fan capacity, and heat sink configuration. The simulation results showed that the heat sinks were able to achieve a cooling capacity of up to 230W at the maximum temperature difference of $19^{\circ}C$. To verify the results from the numerical simulation, an experiment was conducted under the same condition as the numerical simulation, and their results were compared. The design program gave good prediction of the effects of various parameters involved in the design of a heat sinks for an electronic telecommunication system.