• Title/Summary/Keyword: 연소가스 농도

Search Result 354, Processing Time 0.021 seconds

Combustion Emission Gas Analysis & Hazard Assessment to the Litter Layer in Forest (임내 낙엽층의 연소 방출가스 분석 및 건강 위험성 평가)

  • Kim, Dong-Hyun;Lee, Myung-Bo
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2009.04a
    • /
    • pp.358-364
    • /
    • 2009
  • 본 연구에서는 우리나라 주요 침엽수종인 소나무(Pinus densiflora)와 활엽수종인 굴참나무(Quercus variabilis)의 낙엽에 대해 FTIR(Fourier Transform Infrared) 분광계를 이용하여 배출 연소가스 종류 및 농도를 측정하였다. 실험결과 소나무와 굴참나무 낙엽에서 Carbon monoxide, Carbon dioxide, Acetic acid, Butyl acetate, Ethylene, Methane, Methanol, Nitrogen dioxide, Ammonia, Hydrogen Fluoride, Sulfur dioxide, Hydrogen bromide 등 13개 연소가스가 검출되었고 굴참나무 낙엽에서는 Nitrogen monoxide가 추가로 검출되었다. 방출된 연소가스의 전체 농도는 소나무 낙엽이 굴참나무 낙엽에 비해 4.5배 많이 검출되었다. 특히, 시간가중평균가스농도(TWA : Time-weighted average, ppm) 기준을 초과하는 연소가스는 Carbon monoxide, Carbon dioxide, Butyl acetate가 검출되었고 단시간노출기준(STEL : Short Term Exposure Limit, ppm) 기준을 초과하는 연소가스는 Carbon monoxide, Carbon dioxide로 소나무 및 굴참나무 모두에서 나타났다. 이에 산불에서의 낙엽층 지표화 연소시 전체 가스 방출량의 99% 이상을 차지하고 있는 Carbon monoxide, Carbon dioxide의 건강 위험성이 높은 것으로 나타났다. 하지만, 검출된 다른 건강 위험성 가스의 경우에도 연소물질의 양이 증가할수록 연소가스의 농도가 높아져 건강안정성에 해가 있을 것으로 판단되며 또한 검출된 연소가스 중 나무의 주요구성 원소가 아닌 Bromide, Fluoride 화합물에 대해서는 토양으로부터의 오염 또는 분석과정에서의 노이즈로 인한 검출 등에 대한 보다 면밀한 검토가 필요할 것으로 판단된다.

  • PDF

화재현장 연소가스 감지소자 감도성능검증 연구

  • Yu, Song-Hyeon;Choe, Mun-Su;Park, Sang-Tae;Hong, Seong-Ho;Yu, Sang-Pil
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2013.04a
    • /
    • pp.128-129
    • /
    • 2013
  • 화재 현장에는 소방대원의 생명에 위협이 될 수 있는 다양한 연소가스가 발생하며, 소방대원의 안전에 다양한 연소가스의 농도를 실시간으로 측정하는 것은 매우 중요하다. 현재 무선통신 기술의 발달과 센서 기술의 발전으로 저전력, 소형의 센서를 이용하여 무선으로 화재현장의 온습도조건, 발생가스의 농도, 소방대원의 생체신호를 화재현장의 지휘센터로 보내주는 기술의 개발이 진행되고 있다. 이러한 추세에 맞추어 측정된 가스의 농도를 실시간으로 지휘센터로 송수신하는 기술의 연구가 활발히 진행 중이다. 본 연구는 화재환경에서 주로 발생되는 CO, NO2, NH3를 위주로한 고온의 환경에서 농도를 측정하기 위한 방법에 대한 연구이다.

  • PDF

Examination of validation for equivalent gas to replace natural gas (천연가스를 모사하는 등가가스의 유효성 검토)

  • Kim, Jong-Min;Lee, Seungro;Lee, Chang-Eon
    • Journal of Energy Engineering
    • /
    • v.22 no.2
    • /
    • pp.128-135
    • /
    • 2013
  • In order to estimate the combustion characteristics and the gas interchangeability for natural gas with various compositions per each production area, equivalent gas are using to replace natural gas. It is known that an equivalent gas has the same the heating value, the compression factor, the relative density, CO emission and the burning velocity as the original natural gas. However, it is not reported that the flame shape and thermal efficiency and NOx emission by real gas appliance. In this study, equivalent gas was examined the validation to replace natural gas. The CO emission the burning velocity and the flame temperature were reconfirmed, and the flame shape, the NOx emission and the thermal efficiency were numerically and experimentally investigated. As results, there was not a large difference between natural gas and equivalent gas. This result demonstrated that there was no problem using equivalent gas to replace natural gas.

난류확산화염에서 산소부화가 NO생성에 미치는 영향에 관한 실험적 연구

  • 채전우;전영남;김영권
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.4
    • /
    • pp.1022-1032
    • /
    • 1990
  • 본 연구에서는 기체연료 연소시 산소부화연소의 적용에 대한 연구를 시작하는 단계에서 상용 프로판을 산소부화연소 시킴으로써 첨가된 산소에 의한 반응시간의 단 축과 공급 공기량중의 질소량 저감에 희한 연소가스중의 NO농도를 측정하고, 이에 따 른 화염장의 온도 및 연소가스중의 $O_{2}$ 및 N$_{2}$농도를 측정하여 그들의 상관관 계를 가지고 NO의 배출특성을 고찰함으로써 기체연료의 산소부화연소에 따른 효율적인 에너지 이용을 위한 연소장치개발과 오염물질 저감대책에 기초자료를 제공하는데 그 목적이 있다.

A Study on the Toxicity of Closing material of building with chamber (Smoke density chamber를 적용한 건축물 마감재의 연소가스 독성 평가)

  • Lee, In-Ku;Cho, Nam-Wook;Lee, Bong-Jae;Rie, Dong-Ho
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.248-251
    • /
    • 2011
  • 연소가스분석을 통한 건축물 마감재료의 연소독성평가를 위해 독성지수 계산법(NES 713)을 활용하여 독성평가를 수행하였다. 가연성 건축재료(우레탄, 고무바닥재)를 대상으로 독성가스를 측정하기 위해 ISO19702에서 규정하는 FT-IR(퓨리에변환적외선분광분석기)을 이용하였으며, 화재 모델은 ISO5659의 Smoke Density Chamber를 사용하였다. 독성지수를 산정하기 위해 Cf(사람이 30분간 노출시에 사망할 수 있는 가스의 농도)를 기준으로 하였다. 본 연구를 통해 연소가스 독성지수 연구의 기초연구자료로 활용하고자 한다.

  • PDF

Analysis on the Results of Measured Concentration of the Combustion Gases Considering Respiration Characteristics in Gasoline Pool Fire (가솔린 풀 화재에서 인체 호흡량 변화를 고려한 연소가스 농도 측정 결과 분석)

  • Choi, Seung Il;Kang, Jung Ki;You, Woo Jun
    • Fire Science and Engineering
    • /
    • v.33 no.4
    • /
    • pp.83-88
    • /
    • 2019
  • This study examined the concentration of combustion gases while considering low ventilation and respiration frequency. A one-quarter-size ISO 9705 room corner test was performed. The concentrations of carbon monoxide and oxygen were measured in each case with the continuous inhalation of combustion gas with low ventilation (2, 6, and 10 LPM) and different respiration frequencies (2 s, 5 s, and infinity). The combustion of a gasoline pool fire in the compartment had a theoretical heat release rate of 5.34 kW. The results show that the deviation of the gas concentrations becomes higher as the low ventilation increases compared to the respiration frequency. In addition, as the respiration frequency increases, the variation in the minimum oxygen concentration is larger than the average value, while in the case of carbon monoxide, the variation in the average value is larger than the maximum value. These results show that the inhalation characteristics of refugees should be considered to investigate fires.

The study of combustion gas characteristic by incinerator operation condition. (소각로 운영조건에 따른 연소배가스 특성 연구)

  • Lee, Keon-Joo
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.18 no.1
    • /
    • pp.66-72
    • /
    • 2010
  • This study was done to analyze the condition of combustion exhaust gas that is produced according to incinerator operating condition in A area Kyonggido. The boiler exhaust gas temperature, the oxygen concentration of boiler, the outgassing temperature of Semi Drying Sorber(SDS), the temperature of catalytic reactor, the concentration of NOx, SOx, CO, Hcl and Dust were investigated by change the temperature of incinerator. The concentration of SOx, CO, HCL and DUST were below 5 ppm as increase the temperature of incinerator however the concentration of NOx was increased from 40 ppm to 70 ppm as increase the temperature of incinerator. The boiler exhaust gas temperature and the temperature of catalytic reactor were not changed however the oxygen concentration of boiler was decreased gradually as increase the temperature of incinerator.

A Study on the Pyrolysis of Waste Tires with Partial Oxidation (부분연소를 통한 폐타이어의 열분해 연구)

  • 이종민;김정래;김상돈
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1993.11a
    • /
    • pp.88-91
    • /
    • 1993
  • 유동층 반응기 (H=0.8 m, ID=0.08 m) 에서 폐타이어의 열분해를 수행함에 있어 열분해에 사용되는 열을 외부에서 공급함과 동시에 일부는 내부에서 자체적으로 연소시켜 열을 얻고자 하였다. 온도 증가에 따라 가스의 수율은 40 %까지 증가하였고, 반면에 오일의 수율은 감소하였다. 또한 가스중에 heavy hydrocarbon 이 감소함과 동시에 H$_2$ 및 light hydrocarbon 이 증가하였고 이로 인해 가스 부피당 발열량은 감소하는 것으로 나타났다. 가스의 체류시간도 가스조성에 상당히 영향을 미치는 것으로 나타났으며, 본 시스템에서 발열량 및 가스생성량은 2 u$_{mf}$ 에서 최소치를 나타내는 것으로 보였다. 또한 $O_2$ 농도의 증가는 결국에는 생성가스의 연소를 일으키며, 적당한 $O_2$ 농도의 설정으로 이의 연소를 최소화하는 작업이 필요하다.

  • PDF

Low NOx Combustors in a Industrial Gas Turbine (산업용 가스터빈의 저NOx 연소기)

  • 신동신
    • Journal of the KSME
    • /
    • v.34 no.12
    • /
    • pp.929-939
    • /
    • 1994
  • 최근 환경문제와 관련하여 정제된 석유 연료가 아닌 천연가스와 같은 연료의 사용이 증가하면서 산업용 가스터빈의 연소기술에 대한 관심이 집중되고 있다. 가스터빈 연소로 생성되는, 환경을 위협하는 오염물은 연기, 수증기, 일산화탄소(CO), 미연 탄화수소, $NO_{x}$, $SO_{x}$ 등이 있다. 수증기 및 일산화탄소는 지구 온실화에 영향을 미치고 있으나 그다지 심각한 정도는 아 니며, $SO_{x}$는 독성이 있으나 연료 정제시 제거되어질 수 있다. $NO_{x}$는 지구의 오 존층을 파괴하여 생태계를 위협하기 때문에 오염 배출물중 가장 심각하게 고려되어지고 있다. 미국에서는 법으로 산업용 가스터빈의 $NO_{x}$의 양을 규제하고 있는데 15% 산소배출농도에 대하여 1984년에 75ppm에서 1993년에 30ppm으로 낮추어 규제하고 있다. 일본도 미국과 비슷한 수준으로 규제하고 있으며, 따라서 최근의 가스터빈 연소기술은 저 $NO_{x}$연소기에 대한 것으로 저$NO_{x}$연소에 관한 개론 및 가스터빈 연소기의 저$NO_{x}$화 방법, 그리고 미 국과 일본의 최근의 저$NO_{x}$연소기 개발동향에 대하여 다루고자 한다.

  • PDF

Ethylene 공정 안전을 위한 Ethylene Gas의 안전특성치 고찰

  • 하동명;이수경
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 2003.10a
    • /
    • pp.170-175
    • /
    • 2003
  • 화학과 석유화학 산업의 많은 공정에서는 가연성가스가 공정 가스로 사용되거나 발생될 수도 있다. 최근 석유화학단지에서 화재 및 폭발이 빈번하게 발생되고 있으므로 이에 대한 재해를 예방하기 위해서는 공정 조건에서의 이들 가연성가스의 연소특성을 알 필요가 있다. 연소특성들로는 폭발한계, 인화점, 최소자연발화점, 최소산소농도, 최소발화에너지, 연소열 등을 들 수 있다.(중략)

  • PDF