• Title/Summary/Keyword: 연성 내시경

Search Result 4, Processing Time 0.017 seconds

FHD Flexible Endoscopy Design Using Wedge Prism (Wedge Prism을 이용한 FHD급 연성 내시경 광학계 설계)

  • Park, Sung-Woo;Jung, Mee-Suk
    • Korean Journal of Optics and Photonics
    • /
    • v.33 no.6
    • /
    • pp.295-302
    • /
    • 2022
  • In this paper, a wedge prism application method was studied to design a full-high-definition (FHD)-class high-resolution flexible endoscope. In the case of the conventional flexible endoscope optical system, the F number is made large or a liquid lens is applied to obtain the same imaging performance in a wide depth of field. However, there is a problem in that the diameter of the optical system increases because an additional light guide and equipment are required. To solve this problem, two wedge prisms were applied to the flexible endoscope optical system to adjust the image distance for each object distance. First, two wedge prisms were symmetrically placed on the designed endoscopic optical system. An image distance satisfying the target imaging performance according to each objective distance was derived. Next, the wedge prism decenter value for controlling the image distance was derived. By combining these two data, a wedge prism decenter value that satisfied the target imaging performance at each object distance was applied in multi configurations. As a result of the optimal design applied with the wedge prism, a target imaging performance of more than 20% of the modulation transfer function for a resolution of 178 cycles/mm was satisfied in the entire depth of field of 100 mm-7 mm.

Endoscopic Retrieval of Esophageal Fishhooks Using Cerclage Wire: A Case Report (내시경과 Cerclage Wire를 이용한 식도내 낚시바늘 제거: 증례보고)

  • Kim, Young-Ki;Uhm, Mi-Young;Seo, Eu-Gene;Ha, Mi-Hyun;Wang, Ji-Hwan;Jeong, In-Jo;Chang, Hong-Hee;Lee, Hee-Chun;Cho, Kyu-Woan;Lee, Hyo-Jong;Yeon, Seong-Chan
    • Journal of Veterinary Clinics
    • /
    • v.24 no.4
    • /
    • pp.622-626
    • /
    • 2007
  • A 1.6-year-old, intact male beagle dog was presented with three day history of odynophagia and anorexia. According to the history and radiographic findings, the patient was diagnosed with esophageal and gastric foreign body due to ingesting fishhooks. Gastroesophagoscopy revealed that one fishhook located in the thoracic esophagus cranial to the heart base and the other located in the cardia region were connected with a single fishing line. Gastrotomy was performed to remove the fishhook in the cardia region and to sever the connecting fishing line. After gastrotomy, endoscopic attempts to remove the esophageal fishhook with a three, five pronged endoscopic grasping forceps, and a biopsy were unsuccessful because the fishhook was embedded deeply in the mucosa membrane. A handmade cerclage wire(16G) shaped like a snare forceps was advanced into the esophagus while visualizing the fishhook endoscopically. The cerclage wire was used to hang and retract the foreign body. The fishhook was retracted orally, resulting in successful removal. Ten days after the operation, the patient fully recovered and was discharged.

Design of Sensor Network for Estimation of the Shape of Flexible Endoscope (연성 대장내시경의 형상추정을 위한 센서네트워크의 설계)

  • Lee, Jae-Woo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.2
    • /
    • pp.299-306
    • /
    • 2016
  • In this paper, a method of shape prediction of an endoscope handling robot that can imitate a surgeon's behavior using a sensor network is suggested. Unit sensors, which are composed of a 3-axis magnetometer and 3-axis accelerometer pair comprise the network through CAN bus communication. Each unit of the sensor is used to detect the angle of the points in the longitudinal direction of the robot, which is made from a flexible tube. The signals received from the sensor network were filtered using a low pass Butterworth filter. Here, a Butterworth filter was designed for noise removal. Finally, the Euler angles were extracted from the signals, in which the noise was filtered by the low path Butterworth filter. Using this Euler angle, the position of each sensor on the sensor network is estimated. The robot body was assumed to consist of links and joints. The position of each sensor can be assumed to be attached to the center of each link. The position of each link was determined using the Euler angle and kinematics equation. The interpolation was carried out between the positions of the sensors to be able to connect each point smoothly and obtain the final posture of the endoscope in operation. The experimental results showed that the shape of the colonoscope can be visualized using the Euler angles evaluated from the sensor network suggested and the shape of serial link estimated from the kinematics chain model.

Diagnosis and Treatment of Feline Inflammatory Polyp with Video Otoscopy : A Case Report (고양이에서 비디오 이경검사법을 이용한 염증성 폴립의 진단 및 치료 1례)

  • Park, Se-Jin;Lee, Seung-Yong;Kim, Young-Ki;Seok, Seong-Hoon;Hwang, Jae-Min;Jeong, Dong-Hyuk;Lee, Hee-Chun;Yeon, Seong-Chan
    • Journal of Veterinary Clinics
    • /
    • v.30 no.4
    • /
    • pp.301-304
    • /
    • 2013
  • Otic mass removal was performed in a 19-month-old, castrated domestic shorthair cat. The patient had 1- year history of recurrent otitis externa, and then otic mass in the right ear canal was found. Under general anesthesia, 2.7 mm rigid endoscope was inserted to the right ear canal with the irrigation system. The ovoid-shaped, 4.9 mm in diameter red otic mass located in the right ear canal was removed via traction-avulsion. Then, rupture of the tympanic membrane was revealed and otic flushing was performed with sterile isotonic (0.9%) saline to remove exudates. Histologically, the removed polyp was diagnosed as granulation tissue with severe ulceration. The patient didn't reveal any remarkable abnormality after surgery, and no recurrence were found after 5 months follow up. The video otoscopy seems to offer a useful option for treatment of a feline inflammatory polyp.