• Title/Summary/Keyword: 연기제어

Search Result 123, Processing Time 0.031 seconds

Analysis of Performance-based Design Guides of Smoke Control System (성능위주 연기제어 설계지침 분석)

  • Kim, Jung-Yup
    • Fire Science and Engineering
    • /
    • v.30 no.4
    • /
    • pp.6-13
    • /
    • 2016
  • With regard to smoke control system, the design guidelines of smoke exhaust for accommodation and smoke control for evacuation stairs and vestibule has been proposed domestically, but after reviewing the applicability to modern buildings that tend to be larger, higher and complex, a smoke control system according to domestic design guidelines might have difficulty in securing the safety from smoke in a fire. Therefore, it is necessary to adopt the performance-based design of a smoke control system that can enhance the safety and integrate the smoke control functions and design depending on the characteristics of fire and building structure in the case of fire in a large, high-rise, and complex building. This study analyzed the domestic design guidelines of a smoke control system and this paper proposes the part requiring improvement, and examines the legal system and guidelines on performance-based design of smoke control system in foreign countries.

Establishment of Pre-Pilot Test Bed for Real Scale Experiment Study in Smoke Management (실규모 연기제어 실험연구를 위한 Pre-Pilot Test Bed 구축)

  • Kim, Jung-Yup;Shin, Hyun-Joon;Joo, Sang-Hyun
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.81-84
    • /
    • 2012
  • 건축물에서 화재가 발생할 경우 연기에 의한 요인이 인명피해의 주요 원인으로 파악되고 있다. 특히 건축물이 고층화, 복합화, 대형화되면서 화재시 연기에 취약한 건축물이 증가하고 있고, 또한 기존의 연기제어 설계기준이 개선되어야 할 필요가 발생하고 있다. 이러한 요구에 부응하기 위해서는 새로운 조건에 대한 연기확산 및 연기제어에 대한 수행되어야 하며, 이론 수치해석적 연구와 더불어 실제적인 실험적 연구가 되어야 한다. 한국건설기술연구원 화재안전연구센터에는 5층규모의 제배연 실험동이 건립되어 있으며, 다양한 건축물 조건 및 연기제어 방식에 따른 실규모의 실험적 연구가 가능하도록 설비가 구성되어 있다. 본 논문에서는 이러한 Pre-Pilot Test Bed의 구축현황과 관련 실험내용을 소개하고자 한다.

  • PDF

Case Study of a Field Test for a Smoke Control System Using Sandwich Pressurization (샌드위치 가압을 이용하는 연기제어 시스템의 현장실험 사례 연구)

  • Kim, Jung-Yup;Ahn, Chan-Sol
    • Fire Science and Engineering
    • /
    • v.30 no.5
    • /
    • pp.87-92
    • /
    • 2016
  • Amid the growing number of high-rise complex buildings in Korea, efficient smoke prevention technology in a fire is required and as an alternative of a mechanical smoke control system in high-rise buildings, the use of a smoke control system using sandwich pressurization has been on the rise. In such a system, the appropriate pressure difference and the data for designing the air supply and exhaust flow rate are necessary to prevent the spread of smoke and offer a tenable evacuation environment. As part of such effort, this paper presents a field test process and result after testing a building where such a smoke control system using sandwich pressurization has been installed. A ventilation rate of 6 cycles per hour were applied to simulate the air exhaust flow rate on a fire floor and the air supply flow rate on the floors above and below the fire floor. As a result of the system operation, pressure difference of approximately 260 Pa between the 12th floor of a fire and the 13th floor was generated. The over pressure of the experiment has a serious effect on the evacuation or fire compartment so that it is necessary to examine the improvement.

Basic Study on the Proportional Control System Development of Air Supply Damper (급기댐퍼의 비례제어시스템 개발에 관한 기초 연구)

  • Lee, Dong-Myung;Yu, Byung-Ku
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.97-100
    • /
    • 2012
  • 본 연구는 비례제어시스템의 개발에 관한 기초 연구로서 건축물 화재에서 연기이동의 원인이 되는 압력수두손실, 굴뚝효과, 바람의 영향 등과 피난시 과압방지를 효율적으로 제어하여 제연구역에 균일한 허용차압을 유지시킬 수 있는 제연구역 급기댐퍼의 비례제어시스템을 개발하여 화재실로부터 발생된 연기가 다른 공간으로 침입 확산되는 것을 방지하고 피난안전성을 확보하여 인명과 재산피해를 최소화하는 것이며, 비례제어시스템의 로직 정립과 공학 해석에 의한 시스템 설계에 관한 것이다.

  • PDF

A Study on the Integration Control System Development for Smoke Control (연기제어를 위한 통합제어시스템 개발에 관한 연구)

  • Lee, Dong-Myung
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.6 no.4 s.23
    • /
    • pp.15-20
    • /
    • 2006
  • This study developed integration control system that improve efficiency and give flexibility of smoke control system and can improve prevention of disasters performance. The reliable each kind sensor and of integration control system was developed by establishing the specifications, algorithms and constructing engineering data. More correct and reliable control function of optimization can be obtained by the central control from integration control system rather than the existent individual control. This sees to do to impose flexibility to smoke control system. Also, this will provide the basics of integration control system and ability security of smoke control system and can construct smoke control system of performance based.

아트리움의 Ceiling Jet 온도 예측 모델 비교

  • 김운형;김종훈;이수경
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 2000.06a
    • /
    • pp.144-149
    • /
    • 2000
  • 최근에 국내에서도 대형 쇼핑 몰이나 건축물에 부속된 아트리움 등 대형공간을 도입한 건축물이 점차 증가하고 있다. 따라서 건물 방화 설계자는 화재시 공간의 특성에 따른 열과 연기의 확산과 이동에 관한 정량적인 해석이 필요하지만 국내에서는 아직 이에 대한 관련 규정이 미비한 실정이다. 대형 공간의 공학적인 해석은 크게 실험을 통하여 제시되는 계산공식을 이용하거나 대상 공간의 화재 조건을 예측하는 컴퓨터 모델을 이용할 수 있다. 외국의 경우, 미국의 NFPA 92B는 이러한 공간에 대한 제연 시스템에 적용하는 공식과 계산식을 제시하고 있으며 이를 통하여 연기나 열 감지기의 작동시간, 연기 발생비율, 연기 층의 하강을 제어하기 위한 배기량 등을 계산할 수 있다. (중략)

  • PDF

A Study on the Historical Comparative of Smoke Control for Fire Safety Law and Building Law (국내의 연기제어 관련 소방법과 건축법의 변천과정에 관한 연구)

  • Kim, Hye-Won;Jin, Seung-Hyun;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.97-98
    • /
    • 2017
  • These days the buildings are getting higher, bigger, and in a deep. According to that, it was the Large-Scale casuality by smoke from Daeyeongak Hotel fire in 1971 to Uijeongbu apartment fire in 2015, and the law of smoke control has consistently changed. but the analysis for improving the law isn't working. Therefore on this study, it conducts the analysis of historical comparative about smoke control and it will present the basic data for improving the law of smoke control and in-depth analysis.

  • PDF