Abstract
This study developed integration control system that improve efficiency and give flexibility of smoke control system and can improve prevention of disasters performance. The reliable each kind sensor and of integration control system was developed by establishing the specifications, algorithms and constructing engineering data. More correct and reliable control function of optimization can be obtained by the central control from integration control system rather than the existent individual control. This sees to do to impose flexibility to smoke control system. Also, this will provide the basics of integration control system and ability security of smoke control system and can construct smoke control system of performance based.
Keywords
smoke; integration control system; smoke control; pressure differential; smoke control damper; buoyancy;
Citations & Related Records
연도 인용수 순위
  • Reference
1 NFSC 501A (2004). 특별피난계단의 계단실 및 부속실 제연설비설치의 화재안전기준, 소방방재청
2 이동명 등 (2005). 제연시스템의 자동 차압센서 알고리즘 개발에 관한 연구, 한국화재소방학회 춘계학술논문발표 논문집, 한국화재소방학회, pp. 138-144
3 이동명, 김엽래 (2006). 고 정밀 제연제어시스템의 개발에 관한 연구, 한국방재학회 춘계발표회 논문집, 한국방재학회, pp. 696-702
4 이동명 (2005). 제연구역의 자동 차압센서 개발에 관한 연구, 한국방재학회 논문집, 한국방재학회, 제5권, 제3호, pp.315-345
5 NFPA (2001). Recommended practice for smoke control system(92A)
6 NFPA (2002). SFPE, Handbook of Fire Protection Engineering, NFPA, 3rd ed., pp. 4-274-291 (2002)