• Title/Summary/Keyword: 연구소 건축

Search Result 853, Processing Time 0.034 seconds

Analysis of the Applicability of Ground Stabilizer Using Recycled Resources as Prebored Piles (매입말뚝 주면고정액으로 순환자원을 재활용한 지반안정재의 활용 가능성 분석)

  • Seo, Se-Gwan;Song, Sang-Huwon;Cho, Dae-Sung
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.9 no.3
    • /
    • pp.287-294
    • /
    • 2021
  • In this study, tests were performed to analyze the feasibility of using the ground stabilizer from recycled resources such as blast furnace slag powder as filling material of prebored piles. For this, specimens were prepared by applying 70% and 83% of the general water/binder ratio of the filling material of prebored piles. And compression test, model test, and shaking table test were performed to determine the compressive strength, skin friction on the surface between prebored pile and filling material, and seismic performance of ground stabilizer. As a result of the tests, the compressive strength exceeded the relevant domestic standards, and the skin friction was equivalent to that of ordinary portland cement. In addition, the amount of vertical and horizontal displacement caused by earthquakes was found to be much smaller than the domestic standard. Therefore, when considering the test results comprehensively, it is judged that the feasibility of using a ground stabilizer from recycled resources as filling material for prebored pile is sufficient.

Hydrological performance analysis of green wall through indoor experiment (실내실험을 통한 벽면녹화에 따른 물순환 효과 분석)

  • Ji Hyun Moon;Jae Rock Park;Soon Chul Kwon;Jae Moon Kim
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.302-302
    • /
    • 2023
  • 최근 도시의 왜곡된 물순환 문제를 해결하기 위해서 저영향개발(Low Impact Development, LID) 기법을 적극적으로 도입하고 있다. 저영향개발은 자연의 침투, 증발산, 여과 등의 자연기작을 모방하여 강우유출수를 침투 및 저류시키는 기법으로 물순환 체계를 회복시킬 수 있다. 저영향개발 기법의 하나인 벽면녹화는 건축물이나 기반 시설물의 벽면과 같은 인공지반에 기반을 조성하고 식물을 식재하는 시설로 짧은 시간에 녹지 면적을 만들 수 있다. 또한, 건축물로 인해 생겨난 수직적인 면을 녹지로 활용할 수 있어 도시에 매우 특화된 시설이다. 본 연구는 벽면녹화의 저영향개발 시설로서의 성능을 확인하기 위해 실내 실험을 진행하여 강우유출수 저감효과 및 지체시간 지연효과를 확인하였다. 강우유출수 저감효과는 유입량 대비 저류량을 기준으로 유출저감률을 산정하여 분석하였으며, 총 유출시간을 측정하여 지연효과를 판단하였다. 벽면녹화 현장실험 대상지는 경상남도 양산시 물금읍 부산대학교 양산캠퍼스에 위치한 한국 녹색인프라저영향개발센터이며, 실내에 플랜터형 벽면녹화 시스템을 적용하였다. 부산시 금정구 2012년~2021년의 강수량을 사용해 백분위수 강우사상을 기준으로 30, 50, 70mm/hr의 강우 시나리오를 선정하였다. 물순환 효과를 판단하기 위해 불투수면을 대조군으로 설정하여 불투수면의 유출이 종료되는 시점까지 지표면 유출을 모니터링 하였다. 그 결과, 30, 50, 70mm/hr 시나리오별 유출률은 91.76%, 92.18%, 94.54%로 불투수면과 대비하여 유출이 적게 발생하였으며 총 유출시간은 불투수면대비 47분, 88분, 58분 증가하여 지연효과가 있음을 확인하였다. 본 연구는 실험을 통해 벽면녹화의 수문학적 성능을 분석하고자 유출량 저감효과와 지연효과를 확인하였다. 추후 다양한 강우 시나리오와 제원에 따라 실험이 수행된다면 더 정확히 벽면녹화의 물순환 효과를 확인할 수 있을 것이다.

  • PDF

Research of Dry Reduction Process of Waste Tin Oxide using Methane (메탄가스를 이용한 폐주석산화물의 건식환원시스템)

  • Hyun-Chul Jung;Se-Kwon Kim;Sang-Yeol Kim
    • Resources Recycling
    • /
    • v.31 no.6
    • /
    • pp.18-24
    • /
    • 2022
  • Dry reduction using natural gas was proposed to recover tin from waste tin oxide generated in a tin bath that was used for controlling the smoothness of architectural glass during production, and the reduction behavior was investigated. The utilized vertical natural gas dry reduction system is capable to process 4 L or 20 kg depending on input raw materials. The system was established by applying the upper intake and lower discharge method. The recovery rate was 97.2% at 800 ℃ and 4 sccm flow rate and increased with the amount of input gas. Hydrogen accounted for 23% of the discharge gas, showing a 16.6% hydrogen conversion rate. The reaction behavior of tin recovered via natural gas reduction provides basic data on the new waste resource reduction/recovery technology.

Simulation on the Alternation of Limestone for Portland Cement Raw Material by Steel By-products Containing CaO (CaO 함유 철강 부산물을 활용한 시멘트 원료 석회석 대체 시뮬레이션)

  • Jae-Won Choi;Byoung-Know You;Min-Cheol Han
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.11 no.1
    • /
    • pp.1-8
    • /
    • 2023
  • In this study, to reduce CO2 emission in the cement manufacturing process, we evaluated the limestone that is used as a raw material for cement, substituted with steel slag by the various substituted levels. Based on the chemical composition of each raw materials including limestone, and blast furnace slow cooling slag, converter slag, and KR slag as an alternative raw material, we simulated the optimal cement raw mixture by the substitution levels of limestone. Test results indicated that the steel slags contain a certain level of CaO that can be used as alternative decarbonated raw materials, and it has enough to partially reduce the amount of limestonem. And we estimated the maximum usable levels of each raw material. In particular, it was confirmed that by using a mixture of these raw materials rather than using them one by one, the effect of reducing limestone was increased and CO2 emission from the cement manufacturing process could be reduced.

A Study on the Structural Behavior of Fabricated Columns Reinforced with Steel sheet Forms and Angles (ㄱ형강과 강판을 이용한 조립 기둥의 거동에 관한 연구)

  • Kim, Sung-Bae;Lee, Chang-Nam;Yoon, Yeong-Ho;Kim, Sang-Seup
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.11 no.4
    • /
    • pp.89-98
    • /
    • 2007
  • The purpose of this study is to experimentally evaluate the structural behavior of built-up type column consisted of angles and y-shape steel sheet forms for filling concrete. This column for minimizing form working and reinforcement placing is able to improve capacity of construction and reduce the term of works. Thirteen 1/3 scaled columns were fabricated. The main variables are 1) effect of angles and y-shape steel sheets of fabricated columns, 2) slenderness of column, 3) eccentricity of column. The results show that the experimental capacity of built-up type column is similar to theoretical one by reinforcement concrete design code. The maximum loads increase according to the rate of angle to cross section of column.

A Study on Reformability and Application of Tensegrity Modules (텐서그러티 모듈의 변형 및 응용에 관한 연구)

  • Choi, Sun-Young;Park, Sun-Woo;Park, Chan-Soo
    • Journal of Korean Association for Spatial Structures
    • /
    • v.5 no.2 s.16
    • /
    • pp.73-79
    • /
    • 2005
  • Tensegrity is a relatively new structural system based on the use of continuous tension-discontinuous compression. Of course, a much more detailed structural investigation would be necessary, but at least in order to achieve the intended purpose, it is essential to understand the structural principles and the fundamental forces of tensegrity. Once this point is established, the applications of them to architecture are described, as well as the characteristics of these structures. Then, in spite of the controversial definitions to explain these systems, several examples of tensegrity prototypes or modules constructed in iESD(Institute of Environmental Structure Design) are presented to illustrate the feasibility of tensegrity as a lightweight structure. In this work, consequently, the reformability and application of tensegrity modules have also been researched in architecture, after the patterns of basic module as well as fundamental definition are introduced.

  • PDF

Effects of Type of Synthetic Fiber on Material Properties of Cementless Composite (합성섬유 종류가 무시멘트 복합재료의 재료 거동에 미치는 영향)

  • Choi, Jeong-Il;Park, Se-Eon;Cha, Sang Lyul;Lee, Bang Yeon
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.7 no.3
    • /
    • pp.255-261
    • /
    • 2019
  • The purpose of this study is to investigate effects of types of synthetic fibers on mechanical properties of alkali-activated slag composite. Materials and mixture proportion for matrix are determined, and the compressive strength, tensile performance, and cracking patterns of three composites reinforced by polypropylene, polyvinyl-alcohol, and polyethylene fibers. From the test results, it was observed that polyvinyl-alcohol fiber-reinforced composite and polyethylene fiber-reinforced composite had similar tensile performance. On the other hand, polypropylene fiber-reinforced composite showed low tensile performance. And it was exhibited that other factors except tensile strength and aspect ratio of fiber influence significantly tensile behavior of composite.

Conservativeness Evaluation of Response Acceleration Method used in Seismic Response Analysis of Power Cable Tunnel (전력구의 지진응답해석에 사용되는 응답진도법의 보수성 평가)

  • Lim, Jae-Sung;Kim, Gi-Bae;Chun, Nak-Hyun;Kim, Jae-Min
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.34 no.5
    • /
    • pp.309-317
    • /
    • 2021
  • In this paper, we present the evaluation results for the conservatism of the response acceleration method (RAM), for seismic response analysis of box-type power cable tunnels. We studied 50 examples, considering the cross sections of 25 power cable tunnels, and two soil conditions for each power cable tunnel. A refined dynamic analysis method considering the soil-structure interaction was further employed to evaluate the conservatism of the RAM. The comparison revelated that the seismic responses computed using the RAM were consistent with those obtained using the refined method, since the averages of response ratio (defined as the ratio of the response by RAM to that of the refined method) approached 1.0, and the standard deviations of the response ratio were less than 5%. Finally, we found that applying a load factor of 1.1 to the response of the RAM allowed for a conservative design for seismic loads.

Surface Characteristics of Concrete According to Types of Formworks (거푸집 종류에 따른 콘크리트 표면 특성)

  • Park, Se-Eon;Choi, Jeong-Il;Lee, Bong-Kee;Lee, Bang Yeon
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.9 no.4
    • /
    • pp.499-505
    • /
    • 2021
  • The purpose of this study is to investigate experimentally the physical/chemical properties of concrete surface according to types of formworks. Plywood formwork and coated plywood formwork were prepared. In addition, plywood formwork with sand paper was prepared to simulate deterioration of concrete or rough surface of concrete. Normal concrete was used in this study. The properties of concrete surface were investigated by visual inspection, scanning electron microscopy and energy-dispersive X-ray spectroscopy techniques, elemental mapping, 2D and 3D surface profile measurement, and zeta potential measurement. Test results showed that concrete in a coated formwork had smooth surface and concrete in the formwork with sand paper had rough surface. It was observed that properties of concrete surface depended on types of formworks. Furthermore, differences in surface roughness were significantly higher than those in chemical compositions and zeta potential.

Evaluation of Seismic Response of Masonry Walls Strengthened with Steel-bar Truss Systems by Non-linear Finite Element Analysis (비선형 유한요소 해석에 의한 강봉 트러스 시스템으로 보강된 조적벽체의 내진거동 평가)

  • Hwang, Seung-Hyeon;Yang, Keun-Hyeok;Kim, Sang-Hee;Lim, Jin-Sun;Im, Chae-Rim
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.4
    • /
    • pp.20-27
    • /
    • 2021
  • The present study presents a nonlinear finite element analysis (FEA) approach using the general program of Abaqus to evaluate the seismic response of unreinforced masonry walls strengthened with the steel bar truss system developed in the previous investigation. For finite element models of masonry walls, the concrete damaged plasticity (CDP) and meso-scale methods were considered on the basis of the stress-strain relationships under compression and tension and shear friction-slip relationship of masonry prisms proposed by Yang et al. in order to formulate the interface characteristics between brick elements and mortars. The predictions obtained from the FEA approach were compared with test results under different design parameters; as a result, a good agreement could be observed with respect to the crack propagation, failure mode, rocking strength, peak strength, and lateral load-displacement relationship of masonry walls. Thus, it can be stated that the proposed FEA approach shows a good potential for designing the seismic strengthening of masonry walls.