• Title/Summary/Keyword: 연구소 건축

Search Result 853, Processing Time 0.024 seconds

Form and Location of Chiseong(square-shaped lookout) Constructed in Hanyangdoseong(Seoul city wall) of the 18th Century (18세기에 축조된 한양도성 치성의 형식과 위치)

  • Kim, Young Soo;Song, In Ho
    • Journal of architectural history
    • /
    • v.30 no.2
    • /
    • pp.19-28
    • /
    • 2021
  • The purpose of this study is to research about the construction of Chiseong around the Heunginjimun Gate area in the 18th century. the conclusions derived from the historical evidence of the number, location, size, and form, and construction method of Chiseong was as follows. First, the Chiseong(Square-shaped lookout) of Hanyangdoseong was built in the 29th year of King Yeongjo(1753) and can be found in the national record. Five sites of the Chiseong are currently identified. It is assumed that the Foru was installed on top of some of the Chiseongs. Second, Chiseong was destroyed sequentially in the first half of the 20th century. Third, Chiseong is a rectangular in shape and six are constructed. Fourth, Sixth Chiseong could figure out through Hengryeopungsokdo, the drawing of Jeong Seon.

Effect of Evaluation before Site Application of Poly-acrylic Resin Leakage Repair Materials (폴리아크릴 레진 누수보수재의 선정평가 후 현장 적용에 따른 효과 분석)

  • Cho, Il-Kyu;An, Ki-Won;Song, Je-Young;Oh, Sang-Keun
    • Journal of the Regional Association of Architectural Institute of Korea
    • /
    • v.20 no.6
    • /
    • pp.55-61
    • /
    • 2018
  • This study improved the water repair materials of the polyacrylic system applied to concrete structures by controlling expansion, strengthening water resistance, and improving cohesiveness. The improved polyacrylate repair materials were evaluated against the existing products to verify their performance and level of improvement, and applied on-site to the concrete structures that are leaking the improved water. The verification method measured the presence of water leaks and the moisture content of concrete inside. Moisture levels were measured for two months before and after material installation, and at least 0.8 - 1.7% of humidity was reduced after installing polyacrylic resin, and no leakage was found.

Experimental Evaluation for Structural Performance of Hybrid Damper Combining Steel Slit and Rotational Friction Damper (강재 슬릿과 회전 마찰형 감쇠 장치를 결합한 복합 감쇠 장치의 실험적 구조 성능 평가)

  • Kim, Yu-Seong;Kang, Joo-Won;Park, Byung-Tae;Lee, Joon-Ho
    • Journal of Korean Association for Spatial Structures
    • /
    • v.19 no.3
    • /
    • pp.101-109
    • /
    • 2019
  • In order to develop the compatible damping device in various vibration source, a hybrid wall-type damper combining slit and friction damper in parallel was developed. Cyclic loading tests and two-story RC reinforced frame tests were performed for structural performance verification. As a result of the 5-cyclic loading test according to KBC-2016 and low displacement cyclic fatigue test, The hybrid wall type damper increased its strength and the ductility was the same as that of the slit damper. In addition, As a result of the two-layer frame test, the reinforced frame had about twice the strength of the unreinforced frame, and the story drift ratio was satisfied to Life Safety Level.

An Analysis of External Waterproofing Materials and Construction Technology Status on Single Side Wall in Underground Structures (지하구조물 합벽구간 적용 외방수 재료 및 시공기술 현황 분석)

  • Kim, Meong-Ji;Kim, Soo-Yeon;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.11a
    • /
    • pp.222-223
    • /
    • 2019
  • Waterproofing techniques used in underground structures do not reflect material and construction environments, but rely only on material properties, which inevitably lead to their limits in durable life. In particular, the government intends to investigate the current underground water treatment method and analyze the problems in order to prevent serious corrosion and aging of structures caused by underground water leaks and poor construction.

  • PDF

Confirmation on Basic Adhesion Strength Property Testing of Domestic Rubber Asphalt Waterproofing Sealant in Accordance JC/T 2428 Chinese Industrial Standard for the Establishment of Korea-China Joint Quality Standards (고무 아스팔트 씰의 한중 공동 품질기준 제정을 위하여 국내 재료를 중국업계표준 JC/T 2428의 부착강도 적용시 기본물성 확보 여부 확인)

  • An, Ki-Won;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.11a
    • /
    • pp.226-227
    • /
    • 2019
  • Installation and usage methods are currently different between China and Korea for the same rubber asphalt waterproofing sealant. Quality verification is not properly carried out in this situation, so it is necessary to secure reliability in order to export domestic materials to China. In this study, rubber asphalt waterproofing sealant used as injection-type leakage repair material was tested in accordance to adhesion strength quality test method outlined in the JC/T2428 Chinese Industrial Standard to confirm the basic performance is compliant or not.

  • PDF

A Study on the Area of Rear Garden and its Architectural Dimension at Gyeongbok Palace Constructed during King Gojong's Reign (고종조 중창된 경복궁 후원 영역 및 건축 규모 분석 연구 - 국립문화재연구소 소장본 북궐후원도형 및 북궐도형을 중심으로 -)

  • Kim, Seong-Do
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.34 no.8
    • /
    • pp.95-104
    • /
    • 2018
  • This thesis aims to determine the size of the rear garden and its architectural dimension at Gyeongbok Palace constructed during King Gojong's reign by analyzing Bukgyeol dohyeong(Site plan of Gyeongbok Palace) and Bukgyeol huwon dohyeong(Site plan of Rear Garden of Gyeongbok Palace) applied of scale unit and made from 1905 untill 1909. The results of this study were as follows; With respect to its site, the maximum horizontal length is estimated to be around 448m, the maximum vertical length is around 544m, and the entire area is around $203,905m^2$. Concerning the architecture, the total number of the buildings made up of one or more gan(間) is 32 and the total number of its gan is 292.5, etc.

Algorithm Development for Movable Tensegrity Structure by Iot (Iot에 기반한 동적 텐세그리티 구조를 위한 알고리즘 개발)

  • Jeon, Sang-Hyeon;Ha, Chang-Woo;Kim, Hee-Kyun;Kim, Jae-Yeol
    • Journal of Korean Association for Spatial Structures
    • /
    • v.20 no.4
    • /
    • pp.35-44
    • /
    • 2020
  • In the study, a shape finding procedure for the tensegrity system model inspired by the movement pattern of animal backbone was presented. The proposed system is allowing a dynamic movement by introducing the concept of "saddle" for the variable tensegrity structure. Mathematical process and an algorithm for movable tensegrity to specified points were established. Several examples have applied with in established shape finding analysis procedure. The final tensegrity structures were determined well to a object shape.

A Study on the Maintenance and Management of Local Confucian School architecture in the 1910s (1910년대 향교(鄕校) 건축의 유지와 관리에 대한 연구)

  • Song, Hye-Young
    • Journal of architectural history
    • /
    • v.30 no.6
    • /
    • pp.23-32
    • /
    • 2021
  • This study was described with a focus on the maintenance and management of Local Confucian School(Hyanggyo) architecture, centering around cases investigated through official documents written in the 1910s. In 1910, by the Japanese imperial rule, the regulations on Local Confucian School(Hyanggyo) property were enacted, and the income was paid solely to elementary school education expenses and ancestral rites. Through this process, many Local Confucian School(Hyanggyo) buildings were destroyed while only the space for ritual sacrifices remained by the Japanese colonial rule. In particular, as the land, which was the basis of Local Confucian School's property, was sold for various reasons, the finances gradually deteriorated. In addition, as the architectural acts that Local Confucian School preserves itself are restricted, it loses its original character. This study was of great significance that identified the intention to dispose of Local Confucian School(Hyanggyo) property by Japanese imperialism in the 1910s and clarified the purpose of its disposal.