• Title/Summary/Keyword: 연계처리수질

Search Result 67, Processing Time 0.031 seconds

Advanced Swine Wastewater Treatment with using Membrane Bioreator(A/O) and Nanofiltration (MBR(Membrane Bioreactor: A/O)공정과 나노여과를 이용한 축산폐수 고도처리)

  • 장경국;배태현;김은영;장하원;탁태문
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 2004.05b
    • /
    • pp.115-118
    • /
    • 2004
  • 축산폐수에 대한 방류수 수질기준 항목에 COD의 추가 및 질소와 인의 기준이 강화(1999년)됨에 따라 많은 축산폐수처리시설의 보강과 새로운 기술도입이 요구되고 있다. 따라서 대부분의 공공처리시설에서는 질소 및 인을 제거하기 위하여 2차 처리단계에서 무산소조(탈질조)와 호기성(포기조)를 연계한 생물학적 질소제거를 실시하고, 최종처리단계에서 응집제 투입에 의한 응집ㆍ침전공정후 모래여과 또는 활성탄 흡착공정에 의한 인과 색도제거 하는 등, 생물학적 처리 및 물리ㆍ 화학적 처리시설이 추가적으로 보완ㆍ적용단계에 있다.(중략)

  • PDF

The Estimation of Probability Distribution by Water Quality Constituents Discharged from Paddy Fields during Non-storm Period (영농형태별 영농기간 동안 비강우시 논 유출수의 수질 항목별 확률분포 추정)

  • Choi, DongHo;Hur, Seung-Oh;Kim, Min-Kyeong;Yeob, So-Jin;Choi, Soon-Kun
    • Korean Journal of Ecology and Environment
    • /
    • v.52 no.1
    • /
    • pp.21-27
    • /
    • 2019
  • Analysis of water quality distribution is very important for river water quality management. Recently, various studies have been conducted on the analysis of water quality distribution according to reduction methods of nonpoint pollutant. The objective of this study was to select the probability distributions of water quality constituents (T-N, T-P, COD, SS) according to the farming forms (control, slow release fertilizer, water depth control) during non-storm period in the paddy fields. The field monitoring was conducted monitoring site located in Baeksan-myun, Buan-gun, Jeollabuk-do, Korea during non-storm period from May to September in 2016. Our results showed that there were no differences in water quality among three different farming forms, except for SS of control and water depth control. K-S method was used to analyzed the probability distributions of T-N, T-P, COD and SS concentrations discharged from paddy fields. As a results of the fitness analysis, T-N was not suitable for the normal probability distribution in the slow release fertilizer treatment, and the log-normal probability distribution was not suitable for the T-P in control treatment. The gamma probability distribution showed that T-N and T-P in control and slow release fertilizer treatment were not suitable. The Weibull probability distribution was found to be suitable for all water quality constituents of control, slow release fertilizer, and water depth control treatments. However, our results presented some differences from previous studies. Therefore, it is necessary to analyze the characteristics of pollutants flowing out in difference periods according to various farming types. The result of this study can help to understand the water quality characteristics of the river.

Development and Application of Convergence Process with Solid-Liquid Separation and Membrane for Wastewater Treatment and Reuse (초고속 고액분리 시스템과 분리막을 이용한 농업용수 재이용 수처리시스템 개발 및 현장적용)

  • Choi, Sunhwa;Kim, Haedo;Jang, Kyusang
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2016.05a
    • /
    • pp.591-591
    • /
    • 2016
  • 최근에는 재이용을 위한 하 폐수의 처리 공정에 막을 이용한 기술적용이 증가되고 있는 추세이다(현 등, 2005). 막(membrane)을 이용한 수처리 공정은 원수에 상관없이 고도처리가 가능하며, 재이용수 이용 용도에 따른 수질제어가 가능할 뿐만 아니라 운용의 편리성 때문에 많은 각광을 받고 있다(박 등, 2004). 본 연구에서는 하수처리에 이용되는 분리막의 성능을 극대화하고, 분리막의 오염부하를 줄여주기 위하여 분리막 직전 전처리 시설로 부상방식의 고액분리장치를 개발하였다. 초고속 고액분리시스템은 기존의 응집부상공정을 응용한 기술로서 유기물의 응집시간을 최대 10초~2분 이내로 줄이는 기술을 바탕으로 타워형 모듈 형태로 개발하였다. 초고속 고액분리시스템과 분리막을 연계한 재이용수 수처리시스템의 성능 평가 및 현장적용을 위해 제주도 서부 하수 처리장에 일 $3,000m^3$ 규모의 Test-bed를 구축하였다. 구축된 하수재이용시스템의 처리 공정도는 "유입${\rightarrow}$고액분리시스템${\rightarrow}$분리막(UF, RO)${\rightarrow}$농경지 공급"으로 구성되어 있다. 먼저 하수처리장 방류수를 1차 유입조에 압송하면 전처리시설인 고액분리시스템을 통해 SS 등 입자성 물질이 처리되고, 다음 공정인 2차 처리공정(UF/RO)을 통과한 처리수는 인근지역의 농업용수로 공급되고 있다. 고액분리시스템은 ZT(Zeta Potential Tower) 모듈에서 유입수에 함유되어 있는 부유물질(SS), 유기물(질소, 인)을 응집제와 순간 반응시켜 응결, 응집, 부상방식으로 제거하는 공정이다. 고속 고액분리장치는 분리막 공정과 융 복합하여 다양한 유입수 성상에 따른 수처리를 가능하게 하여 재이용수 수질 향상뿐만 아니라 안정된 수자원 확보 측면에서 긍정적인 기술로 평가되었다.

  • PDF

Application of the SWAT-K Model on the Pangyo Development Area (판교신도시유역의 장기유출해석을 위한 SWAT-K모형 적용)

  • Park, Chang-Eon;Kim, Je-Hyung
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2008.05a
    • /
    • pp.1310-1314
    • /
    • 2008
  • 수도권 지역의 신도시 개발에 따른 유역의 도시화와 인구 증가는 유역의 피복상태를 변화시키고, 생태계에 영향을 미치는 수문학적 과정과 하천수질의 변화를 초래하게 된다. 지표면의 침투, 침루 및 토양함수량을 변화시키고, 차단저류량과 요지저류량(depression storage) 등을 변화시킴으로서 유출량과 수질을 변화시키게 되는 것이다. 이와 같은 수문학적과정을 평가하기 위해서는 수문모형을 사용하는데 본 연구에서는 미국 농림부에서 개발한 SWAT모형을 이용하였다. SWAT-K모형은 SWAT(Soil and Water Assessment Tool) 모형에 인위적, 자연적인 물순환 구조변화와 지표수-지하수 연계 해석 등을 개선하여, 강우 증발산 토양수분 지표수 지하수 등의 시, 공간적 분포를 정량적으로 산정하는 장기유출 해석 모형이다. 또한, 본 모형의 적용을 위하여 GIS를 이용한 공간정보를 처리하여 수문모형의 매개변수를 결정하는 방법이 널리 사용되고 있는데, 본 연구에서는 ArcView GIS를 이용하여 입력자료를 구축하였다. 대상유역은 판교유역으로서 신도시 개발이 한창 진행되고 있는 지역으로서, 개발 과정에 따라 수문특성, 유출특성, 수질변화 특성 등이 계속하여 변화되고 있으며, 개발이 완전히 종료된 이후의 특성을 예측할 필요가 있는 유역이다. 본 연구에서는 SWAT-K모형을 이용하여 판교 신도시 개발에 따른 장기유출량을 예측하였고 모델의 매개변수를 최적화하였으며, 그 결과 본 모델이 장기 유출량 해석 및 판교유역의 수문변화를 평가하는데 유용하게 적용될 수 있을 것으로 판단되었다.

  • PDF

Effective Costal Environmental Management by Conjugation of Modeling of Bio-Purification and Total Allowable Pollutant Loads in Masan Bay (생물정화기작과 총허용오염부하량을 연계한 마산만의 효율적 해양환경 개선방안)

  • Eom, Ki-Hyuk;Kim, Gui-Young;Lee, Won-Chan;Lee, Dae-In
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.15 no.1
    • /
    • pp.38-46
    • /
    • 2012
  • This study carried out current status, characteristics, and problems of coastal environment management on semi-enclosed Masan Bay in Korea and suggests cost-effective and eco-friendly water quality management policy. The pollutants from terrestrial sources into the Bay have apparently environmental pollution problems, such as eutrophication, red tide, and hypoxia. The carrying capacity of the Bay is estimated by hydrodynamic model and ecosystem model, material circulation including bivalve in ecosystem is analyzed by the growth model of bivalve. The resulting reduction in the input load was found to be 50~90%, which is unrealistic. When the efficiency of water quality improvement through bivalve farming was assessed based on the autochthonous COD, 30.7% of the total COD was allochthonous COD and 69.3% was autochthonous COD. The overall autochthonous COD reduction rate by bivalve aquaculture farm was found to be about 6.7%. This study indicate that bivalve farming is about 31% less expensive than advanced treatment facilities that remove both nitrogen and phosphorous.

The Air-stripping Process Conjugated with the Ultrasonic Treatment to Remove TOC in Groundwater around the LPG Underground Storage Cavern (탈기법과 초음파 처리법을 연계한 LPG 지하공동저장소 주변 오염지하수 내 TOC 제거)

  • Han, Yikyeong;Jun, Seongchun;Kim, Danu;Jeon, Soyoung;Lee, Minhee
    • Economic and Environmental Geology
    • /
    • v.55 no.5
    • /
    • pp.511-519
    • /
    • 2022
  • In order to develop an air-stripping based remediation process to remove the TOC (Total Organic Carbon) in groundwater around the underground LPG storage cavern, the laboratory scale experiments at various conditions (change of air injection volume and temperature, the application of ultrasonic treatment, etc.) for two types of groundwater (initial TOC concentration of 608 mg/L and 153 mg/L, respectively). From results of experiment, as the air injection rate for stripping into groundwater increased from 2 L/min to 11 L/min and as the air-stripping time increased from 1 hour to 24 hour, the TOC removal efficiency of air-stripping increased. However, the TOC concentration of treated groundwater was higher than the discharge tolerance limit (100 mg/L) even after 24 hour stripping at the maximum air injection rate of 11 L/min. The main compounds of the TOC in groundwater were identified as methanol and propane and the long stripping time (more than 24 hour) was needed to separate the methanol from groundwater because of the affinity between water and methanol. At 20℃ and 4 L/min of air injection, the TOC removal efficiency increased to 59.1% after 24 hour air-stripping. When the temperature of groundwater increased to 30℃ and 40℃, the TOC removal efficiency increased up to 80.0% and 82.8%, suggesting that more than 24 hour air-stripping at 40℃ is needed to lower the TOC concentration to below 100 mg/L and the additional TOC removal process as well as the air-stripping is necessary. When the temperature increased to 60℃ and the ultrasonic treatment was conjugated with the air-stripping, the TOC removal efficiency increased to 87.8% within 5 hour stripping and the final TOC concentration (72.4 mg/L) was satisfied with the TOC discharge tolerance limit. The TOC removal efficiency for groundwater having low TOC concentration (153 mg/L) also showed similar removal efficiency of 89.7% (the final TOC concentration: 18.9 mg/L). Results in this study supported that the air-stripping conjugated with the ultrasonic treatment could remove successfully the TOC in groundwater around the underground LPG strorage cavern.

Analysis on Nitrogen Faction of Influent Sewage in Domestic STP Based on Long-term Incubation Method (장기 배양법을 이용한 국내 하수처리장 유입 하수의 질소 성상 분석)

  • Im, Jiyeol;Gil, Kyungik
    • Journal of Wetlands Research
    • /
    • v.19 no.2
    • /
    • pp.216-222
    • /
    • 2017
  • Recently, opinions on the need for revision regarding the nitrogen effluent standard of nitrogen from sewage treatment plant(STP) are consistently suggested. However, it is axiomatic that if nitrogen effluent standard is strengthened without a clear basis, it will cause confusion in domestic STP. In this research, nitrogen fraction was analyzed based on a long-term incubation method, according to STP capacity, and the linked treatment of industrial wastewater. As a result, NBDDON, which is difficult to treat in STP, ranged from 1.0 to 1.9 mg/L. larger DON and NBDDON/DON was detected in small STP (under 10,000 m3 /d) as opposed to the large STP. NBDDON/DON in industrial STP was about 0.7 and it was higher than municipal STP. This research result will be used in the important raw data for revision of nitrogen effluent standard of nitrogen from STP.

Development of a Sustainable First Flush Management System for Urban Stream Water Quality Management (도시 하천 수질 관리를 위한 지속가능 초기 강우 오염 관리 시스템의 개발)

  • Seo, Dongil;Lee, Tongeun;Kim, Jaeyoung;Koo, Youngmin
    • Ecology and Resilient Infrastructure
    • /
    • v.3 no.4
    • /
    • pp.247-255
    • /
    • 2016
  • Non-point pollutants from surface runoff during rainfall exert adverse effects on urban river water quality management. In particular, the first flush effect during the initial phase of rainfall can deliver significant amounts of pollutant loads to surface waters with extremely high concentrations. In this study, a sustainable first flush effect management system was developed by using settling and filtration that require no additional power or chemicals. A pilot scale experiment has shown that the removal of total suspended solid (TSS), total nitrogen (TN) and total phosphorus (TP) are in ranges of 84 - 95%, 31 - 46%, and 42 - 86%, respectively. An Integrated Stormwater Runoff Management System (ISTORMS) was also developed to efficiently manage the developed system by linking weather forecast, flow rate and water quality modeling of surface runoff and automatic monitoring systems in fields and in the system. This study can provide effective solutions for the management of urban river in terms of both quantity and quality.

Design and Operation of the Rainwater-Greywater Hybrid System : SNU No. 39 Building (빗물-저농도 오수 하이브리드 시스템의 설계 및 운전 평가 : 서울대 39동)

  • Shim, In-tae;Park, Hyun-ju;Kim, Tschung-il;Jung, Sung-un;Han, Moo-young;Namkung, Eun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.38 no.12
    • /
    • pp.676-682
    • /
    • 2016
  • In this study, rainwater-greywater hybrid system was installed and operated for 1 year in order to evaluate its water quantity, water quality, and economic efficiency in building no. 39. This system was expected to overcome each disadvantages of and maximize each advantages. Low-greywater that was washed up from shower room was treated by MBR (Membrane Bioreactor) and ozone oxidation. Rainwater that was collected from the rooftop was stored in a reservoir, and then transferred to the storage tank that was mixed with treated greywater. After 1 year operating in building no. 39, rainwater and greywater was used to supply $2,599m^3$ of toilet flushing water. In terms of water quality, rainwater was satisfied far the greywater reuse standards except for E.coli. Moreover, low greywater quality was acceptable except for E. coli, BOD, SS, and turbidity. In addition, economic analysis was obtained from benefit-cost ratio (B/C) with 1.11. It implies that the feasibility of the project was reasonable. Furthermore, various research and policy to improve the economic efficiency of water recycling facilities is required to expand the use of water recycling facilities.

The study on introduction of the canal way for Sustainable Development (지속가능한 개발을 위한 주운시설 도입에 관한 연구 (인천 청라지구를 중심으로))

  • Jeon, Jei-Bok;Kwon, Myeong-Sin;Kim, Ji-Ho;Oh, Kyu-Chang
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2008.05a
    • /
    • pp.1462-1466
    • /
    • 2008
  • 본 연구에서는 청라지구 경제자유구역 개발사업의 일환으로 지구내 하천 및 공원에 최적의 주운시설을 도입하기 위한 방안을 모색하였다. 유역의 일반현황 및 국내외 사례조사를 통해 현재까지 진행된 주운관련 사례를 분석하여 적용가능성을 검토하였으며 이수, 치수, 환경 측면에서 주운시설 도입을 위한 종합적인 검토를 수행하였다. 물수지분석, 담수량 및 손실량 파악, 물갈이율 조사 등을 통해 필요수량을 파악하였으며, 산정된 필요수량 확보를 위해 하수처리장 고도처리수, 상수원수, 상수도, 유역관리 등의 다각도의 수량확보 방안을 검토하여 적용가능방안을 제시하였다. 또한 하천수질현황, 국내외 수질기준, 생태계 친수환경에 미치는 영향을 고려하여 목표수질을 설정하였으며, 유역, 하천, 호수공원 및 내부수로 등에 적용가능한 수질보전방안을 제시하였다. 인근하천, 중앙호수 공원, 내부수로를 동시에 고려하여 유역통합관리 차원의 치수안전성 확보 방안을 제시하였으며 주운시설 도입에 따른 추가적인 치수안전성 확보방안을 검토하였다. 특히 간척지라는 지역적 특수성을 고려하여 항구적인 치수 및 이수 대책의 필요성을 제시하였으며, 지속 가능한 개발을 위해 최첨단 유지관리 시스템의 도입 및 안전시설 확보를 통해 재해로 부터 안전한 주운계획을 제시하였다. 향후 청라지구-서해-굴포천 방수로-한강을 잇는 해상과 연계된 주운 개발을 통한 광역운하망 구축 방안을 제고하였다. 향후 주운시설의 도입에 따라 도시의 어매니티 증진과 친수도시 구현, 물순환 확보와 치수에 안전한 방재도시 수립이 가능할 것으로 판단되며 이를 통해 지속가능한 신도시 개발의 초석이 될 수 있을 것으로 사료된다.

  • PDF