• Title/Summary/Keyword: 연결의 방법

Search Result 5,791, Processing Time 0.04 seconds

Habitat Restoration Initiative for Endangered Species Parnassius bremeri (Lepidoptera: Papilionidae) in Korea (멸종위기종 붉은점모시나비의 서식지 복원구상)

  • Kim, Do-Sung;Park, Seong-Joon;Shin, Young-Kyu;Park, Doo-Sang
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.39 no.6
    • /
    • pp.98-109
    • /
    • 2011
  • Habitat restoration initiative is an important factor for the on-site preservation of butterflies. A new habitat necessitates the investigation of the ecology of the butterfly, the landscape of the habitat, the work process, and a cost analysis. In this study, these factors were analyzed through1) re-consideration of the secured results from three years of field work, and 2) a habitat area estimation conducted according to the presence or absence of larvae and adults via a Parnassius bremeri Bremer survey. The investigation of the natural habitat, done for both larvae and adult butterflies found in South Korea, suggested that multiple patches with a minimum size exceeding $300m^2$ and with an average size of about $1,600m^2$were required for survival of this butterfly. Therefore, more than five patches should be considered for butterfly habitat and patches should have similarity to the present habitat environment with transplantation plans for diet plants and honeydew plants. In addition, to activate the migration of the butterfly, cutting down trees that are obstacles to migration, minimizing the distance between patches and the addition of a stepping patch are also required. A patch connectivity analysis showed that patches should be located within 300m of neighboring patches, as the migration of the butterfly will fail if it is more than 600m. Additionally, more than $10,000m^2$ for a single patch or a patch network composed more than five patches over $1,600m^2$ in size were recommended, with a total patch size of $8,000m^2$. Additionally, neighboring multiple patch networks are more desirable than a single habitat in the event a cyclic habitat pattern arises. In this study, we suggest a habitat restoration and optimal prerequisites for a butterfly habitat. It is expected that this research will lead to the creation of a good model for the restoration of butterfly species.

A Document Collection Method for More Accurate Search Engine (정확도 높은 검색 엔진을 위한 문서 수집 방법)

  • Ha, Eun-Yong;Gwon, Hui-Yong;Hwang, Ho-Yeong
    • The KIPS Transactions:PartA
    • /
    • v.10A no.5
    • /
    • pp.469-478
    • /
    • 2003
  • Internet information search engines using web robots visit servers conneted to the Internet periodically or non-periodically. They extract and classify data collected according to their own method and construct their database, which are the basis of web information search engines. There procedure are repeated very frequently on the Web. Many search engine sites operate this processing strategically to become popular interneet portal sites which provede users ways how to information on the web. Web search engine contacts to thousands of thousands web servers and maintains its existed databases and navigates to get data about newly connected web servers. But these jobs are decided and conducted by search engines. They run web robots to collect data from web servers without knowledge on the states of web servers. Each search engine issues lots of requests and receives responses from web servers. This is one cause to increase internet traffic on the web. If each web server notify web robots about summary on its public documents and then each web robot runs collecting operations using this summary to the corresponding documents on the web servers, the unnecessary internet traffic is eliminated and also the accuracy of data on search engines will become higher. And the processing overhead concerned with web related jobs on web servers and search engines will become lower. In this paper, a monitoring system on the web server is designed and implemented, which monitors states of documents on the web server and summarizes changes of modified documents and sends the summary information to web robots which want to get documents from the web server. And an efficient web robot on the web search engine is also designed and implemented, which uses the notified summary and gets corresponding documents from the web servers and extracts index and updates its databases.

Removable implant-supported partial denture using milled bar with Locator® attachments in a cleft lip & palate patient: A clinical report (구순구개열 환자에서 Locator® 유지장치가 장착된 milled titanium bar를 이용한 가철성 임플란트 피개 국소의치의 보철수복증례)

  • Yang, Sang-Hyun;Kim, Kyoung-A;Kim, Ja-Yeong;Seo, Jae-Min
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.3
    • /
    • pp.207-214
    • /
    • 2015
  • Due to the limitations of conventional removable partial denture prostheses to treat a cleft lip & palate patient who shows scar tissue on upper lip, excessive absorption of the maxillary residual alveolar ridge, and class III malocclusion with narrow palate and undergrowth of the maxilla, 4 implants were placed on the maxillary edentulous region and a maxillary removable implant-supported partial denture was planned using a CAD/CAM milled titanium bar. Unlike metal or gold casting technique which has shrinkage after the molding, CAD/CAM milled titanium bar is highly-precise, economical and lightweight. In practice, however, it is very hard to obtain accurate friction-fit from the milled bar and reduction in retention can occur due to repetitive insertion and removal of the denture. Various auxiliary retention systems (e.g. $ERA^{(R)}$, $CEKA^{(R)}$, magnetics, $Locator^{(R)}$ attachment), in order to deal with these problems, can be used to obtain additional retention, cost-effectiveness and ease of replacement. Out of diverse auxiliary attachments, $Locator^{(R)}$ has characteristics that are dual retentive, minimal in vertical height and convenient of attachment replacement. Drill and tapping method is simple and the replacement of the metal female part of $Locator^{(R)}$ attachment is convenient. In this case, the $Locator^{(R)}$ attachment is connected to the milled titanium bar fabricated by CAD/CAM, using the drill and tapping technique. Afterward, screw holes were formed and 3 $Locator^{(R)}$ attachments were secured with 20 Ncm holding force for additional retention. Following this procedure, satisfactory results were obtained in terms of aesthetic facial form, masticatory function and denture retention, and I hereby report this case.

Accuracy of the healing abutment and impression coping combined system on implant impression (인상채득이 가능한 치유지대주를 이용한 임플란트 인상채득의 정확성)

  • Jeon, Kyoung-Bae;Lee, Du-Hyeong;Kim, Jung-Han;Hwang, Jun-Ho;Park, Hyun-We;Lee, Kyu-Bok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.2
    • /
    • pp.105-110
    • /
    • 2015
  • Purpose: The purpose of this study was to evaluate the 3 dimensional accuracy of impression taking on the newly developed healing abutment and impression coping combined system comparing conventional pick-up type impression. Materials and methods: For 10 patients who had a single missing tooth on molar area, dental implants (SuperLine; Dentium, Seoul, Korea) were placed and healing abutment (MyHealing; Raphabio Co., Seoul, Korea) abutments were connected. After 3 months, transfer type impression with MyHealing and pick-up type impression with impression coping were performed twice in the same patients, and master models were fabricated. Customized prosthetic abutments (Myplant; Raphabio Co., Seoul, Korea) were milled and connected to the master casts. Through a dental scanner (Scanner S600; Zirkonzahn, South Tyrol, Italy), the master casts were converted into virtual casts. The length and angulation differences between casts were measured using 3 dimentional analysis program (Geomagic Qualify 12; Geomagic, Morrisville, NC, USA). Statistical significance was calculated using Kruskal Wallis test and Mann-Whitney U test (${\alpha}$=.05). Results: The length differences between the two systems were 0.032 mm in sagittal plane, and 0.029 in coronal plane, and 0.023 mm in horizontal plane. The angulation differences were $0.755^{\circ}$ in sagittal plane, and $1.275^{\circ}$ in coronal plane, and $0.420^{\circ}$ in horizontal plane. Conclusion: The accuracy of newly developed healing abutment system is similar to that of conventional pick-up impression. The new system can reduces chair time by not using separate impression coping.

Clinical Application of Stent-graft in Thoracic Aortic Diseases (흉부 대동맥 질환에서 스텐트-그라프트의 임상적 적용)

  • Kim, Kyung-Hwan;Lee, Cheul;Chang, Ji-Min;Chung, Jin-Wook;Ahn, Hyuk;Park, Jae-Hyung
    • Journal of Chest Surgery
    • /
    • v.34 no.9
    • /
    • pp.698-703
    • /
    • 2001
  • Background: Endovascular stent-graft insertion in aortic diseases is now generally accepted as an attractive alternative treatment modality. We reviewed our clinical experiences of endovascular stent-graft insertion in thoracic aorta. Material and Method: Since 1995, we performed 8 cases of endovasclar stent-graft insertion. Preoperative diagnoses were aortic aneurysms in 4, traumatic aortic ruptures in 3, and ruptured aortic pseudoaneurysm in 1. All procedures were performed in angiography room with the guidance of fluoroscopy. The stent-graft device is a custom-made 0.35mm thickness Z-shaped stainless steel wires, intertwined with each other using polypropylene suture ligation. It is covered with expanded Dacron vascular graft. Result: All procedures were performed successfully. Follow-up studies revealed 2 minimal perigraft leakages. There was no significant leakage or graft migration. 2 patients expired due to multiple organ failure and fungal sepsis. Other survivors(6) are doing well. Conclusion: Endovascular stent-graft insertion is relatively saft and effective treatment modality in the managment of various types of aortic diseases. In may be an effective alternative in aortic diseases of great surgical risk.

  • PDF

Surgical Technique for Korean Artificial Heart(AnyHeart) Implantation Using a Right Thoracotomy Approach (우측 개흉술을 이용한 한국형 인공심장(AnyHeart)의 이식기법)

  • Son. Ho-Sung;Sun, Kyung;Shin, Jae-Seung;Lee, Sung-Ho;Jung, Jae-Seung;Lee, Hye-Won;Kim, Kwang-Taik;Kim, Seung-Chul;Won, Yong-Soon;Min, Byoung-Goo;Kim, Hyoung-Mook
    • Journal of Chest Surgery
    • /
    • v.35 no.5
    • /
    • pp.329-335
    • /
    • 2002
  • Background: The surgical technique for biventricular assist device(BVAD) implantation has mainly consisted of cannulation procedures. A median sternotomy has been the technique of choice as it gives a surgeon an excellent exposure of the heart. However, considering that most patients require a future sternotomy or already have a previous sternotomy, sternotomy-related complication remains a major concern in BVAD implantation. Based on this consideration as well as the clinical experiences of conventional heart surgery, the authors have hypothesized that the cardiac chambers for BVAD cannulation can be approached from the right side of the heart. The purpose of this studs to develop a novel surgical technique of right thoracotomy for BVAD implantation in an animals study. Material and Method: For last two years, 16 (11 calves, 3 canines, and 2 sheep) out of 30 experimental animals with AnyHeart implantation underwent a right thoracotomy. The device was used as an implantable BVAD in 14 animals, a wearable BVAD in 1, and an implantable LVAD in 1. The chest cavity was entered through the 4th intercostal space or the 5th periosteal bed. As for the BVAD use, a right inflow cannula was inserted into the right atrial free wall and a right outflow cannula was grafted onto the main pulmonary artery. A left inflow cannula was inserted into the interatrial groove and a left outflow cannula was grafted on the innominate artery of the ascending aorta. The connecting tubes were brought out through the thoracotomy wound and connected to the pump located in the subcutaneous pocket at the right flank. Result: Except for the 5 animals for a lilting test or during the early learning curve, all recovered smoothly from the procedures. The inflow drainage allowed the pump output 6.5 L/min at the maximum with 3-3.5 L/min in an average. Of the survivors, there noted no procedure-related mortality or morbidity. Necropsy findings demonstrated the well-positioned cannula tips in the each cardiac chamber

Repetition of Apoptosis Induced by Amiloride Derivatives in Human Umbilical Vein Endothelial Cells (제대정맥 내피세포에서 Amiloride 유도체에 의한 Apoptosis 반복)

  • Park, Kyu Chang;Park, Kyu Sang;Moon, Soo Jee
    • Clinical and Experimental Pediatrics
    • /
    • v.46 no.1
    • /
    • pp.56-66
    • /
    • 2003
  • Purpose : Human umbilical vein endothelial cells(HUVECs) play an important role in regulating blood flow by releasing vasoactive substances. It has been reported that endothelial impairment and dysfunction might be a primary cause of placental vascular disease, which is manifested clinically as preeclampsia in mother and intrauterine growth restriction in fetus. Furthermore, the frequency of apoptotic changes is increased in umbilical and placental tissues from growth-restricted pregnancies. However, the various mechanisms of umbilical endothelial cell apoptosis have not been broadly proposed. We investigate the effects of amiloride derivatives on apoptotic death of HUVECs and identify their ionic mechanism. Methods : HUVECs were purchased from Clonetics, and cultured on endothelial cell growth medium. MTT assay and flow cytometry were used for assessing cytotoxic effect and confirming the apoptosis. Changes in intracellular ion concentrations were measured with specific fluorescent dyes and fluorescence imaging analysis system. Results : Amiloride derivatives elicited cytotoxic effects on HUVECs with dose-dependent manners and the rank order of potency is HMA($IC_{50}\;11.2{\mu}M$), MIA>EIPA>>amiloride. HMA-induced cytotoxicity is dependent on extra- and intracellular pH, that is, increase extra- and intracellular pH augmented the cytotoxic effects of HMA. HMA dose-dependently reduced intracellular major ions, such as $K^+$ and $Cl^-$. Interestingly, the depletion of intracellular ions induced by HMA was also significantly enhanced at alkaline extracellular pH. Conclusion : Amiloride derivatives induce apoptosis of HUVECs with dose and pH dependent manners. They reduce intracellular $K^+$ and $Cl^-$ concentration, which is also extracellular pH dependent.

휨 구조의 압전 마이크로-켄틸레버를 이용한 진동 에너지 수확 소자

  • Na, Ye-Eun;Park, Hyeon-Su;Park, Jong-Cheol
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.476-476
    • /
    • 2014
  • 서론: 저 전력 소모를 필요로 하는 무선 센서 네트워크 관련 기술의 급격한 발달과 함께 자체 전력 수급을 위한 진동 에너지 수확 기술에 대한 연구가 활발히 이루어지고 있다. 다양한 구조와 소재를 압전 외팔보에 적용하여 제안하고 있다. 그 중에서도 진동 기반의 에너지 수확 소자는 주변 환경에서 쉽게 진동을 얻을 수 있고, 높은 에너지 밀도와 제작 방법이 간단하다는 장점을 가지고 있어 많은 분야에 응용 및 적용 가능하다. 기존 연구에서는 2차원적으로 진동 에너지 수확을 위한 휜 구조의 압전 외팔보를 제안 하였다. 휜 구조를 갖는 압전 외팔보는 각각의 짧은 두 개의 평평한 외팔보가 일렬로 연결된 것으로 볼 수 있다. 하나의 짧고 평평한 외팔보는 진동이 가해지면 접선 방향으로 응력이 생겨 최대 휨 모멘텀을 갖게 된다. 그러므로 휜 구조를 갖는 외팔보는 진동이 인가됨에 따라 길이 방향과 수직 방향으로 진동한다. 하지만, 이 구조는 수평 방향으로 가해지는 진동에 대한 에너지를 수확하기에는 한계점을 가진다. 즉, 3축 방향에서 임의의 방향에서 진동 에너지를 수확하기는 어렵다. 본 연구에서는 3축 방향에서 에너지를 효율적으로 수확할 수 있도록 헤어-셀 구조의 압전 외팔보 에너지 수확소자를 제안한다. 제안된 소자는 길이 방향과 수직 방향뿐만 아니라 수평 방향으로도 진동하여 임의의 방향에서 진동 에너지를 수확할 수 있다. 구성 및 공정: 제안하는 소자는 3축 방향에서 임의의 진동을 수확하기 위해서 길이를 길게 늘이고 길이 방향을 따라 휘어지는 구조의 헤어-셀 구조로 제작하였다. 외팔보의 구조는 외팔보의 폭 대비 길이의 비가 충분히 클 때, 추가적인 자유도를 얻을 수 있다. 그러므로 헤어-셀 구조의 에너지 수확 소자는 기본적인 길이 방향, 수직방향 그리고 수평방향에 더불어 추가적으로 뒤틀리는 방향을 통해서 3차원적으로 임의의 주변 진동 에너지를 수확하여 전기적인 에너지로 생성시킬 수 있다. 제작된 소자는 높은 종횡비를 갖는 무게 추($500{\times}15{\times}22{\mu}m3$)와 길이 방향으로 길게 휜 압전 외팔보($1000{\times}15{\times}1.7{\mu}m3$)로 구성되어있다. 공정 과정은 다음과 같다. 먼저, 실리콘 웨이퍼 위에 탄성층을 형성하기 위해 LPCVD SiNx를 $0.8{\mu}m$와 LTO $0.2{\mu}m$를 증착 후, 각각 $0.03{\mu}m$$0.12{\mu}m$의 두께를 갖는 Ti와 Pt을 하부 전극으로 스퍼터링한다. 그리고 Pb(Zr0.52Ti0.48)O3 박막을 $0.35{\mu}m$ 두께로 졸겔법을 이용하여 증착하고 상부 Pt층을 두께 $0.1{\mu}m$로 순차적으로 스퍼터링하여 형성한다. 상/하부 전극은 ICP(Inductively Coupled Plasma)를 이용해 건식 식각으로 패턴을 형성한다. PZT 층과 무게 추 사이의 보호막을 씌우기 위해 $0.2{\mu}m$의 Si3N4 박막이 PECVD 공정법으로 증착되고, RIE로 패턴을 형성된다. Ti/Au ($0.03/0.35{\mu}m$)이 E-beam으로 증착되고 lift-off를 통해서 패턴을 형성함으로써 전극 본딩을 위한 패드를 만든다. 초반에 형성한 실리콘 웨이퍼 위의 SiNx/LTO 층은 RIE로 외팔보 구조를 형성한다. 이후에 진행될 도금 공정을 위해서 희생층으로는 감광액이 사용되고, 씨드층으로는 Ti/Cu ($0.03/0.15{\mu}m$) 박막이 스퍼터링 된다. 도금 형성층을 위해 감광액을 패턴화하고, Ni0.8Fe0.2 ($22{\mu}m$)층으로 도금함으로써 외팔보 끝에 무게 추를 만든다. 마지막으로, 압전 외팔보 소자는 XeF2 식각법을 통해 제작된다. 제작된 소자는 소자의 여러 층 사이의 고유한 응력 차에 의해 휨 변형이 생긴다. 실험 방법 및 측정 결과: 제작된 소자의 성능을 확인하기 위하여 일정한 가속도 50 m/s2로 3축 방향에 따라 입력 주파수를 변화시키면서 출력 전압을 측정하였다. 먼저, 소자의 기본적인 공진 주파수를 얻기 위하여 수직 방향으로 진동을 인가하여 주파수를 변화시켰다. 그 때에 공진 주파수는 116 Hz를 가지며, 최대 출력 전압은 15 mV로 측정되었다. 3축 방향에서 진동 에너지 수확이 가능하다는 것을 확인하기 위하여 제작된 소자를 길이 방향과 수평 방향으로 가진기에 장착한 후, 기본 공진 주파수에서의 출력 전압을 측정하였다. 진동이 길이방향으로 가해졌을 때에는 33 mV, 수평방향으로 진동이 인가되는 경우에는 10 mV의 최대 출력 전압을 갖는다. 제안하는 소자가 수 mV의 적은 전압은 출력해내더라도 소자는 진동이 인가되는 각도에 영향 받지 않고, 3축 방향에서 진동 에너지를 수확하여 전기에너지로 얻을 수 있다. 결론: 제안된 소자는 3축 방향에서 진동 에너지를 수확할 수 있는 에너지 수확 소자를 제안하였다. 외팔보의 구조를 헤어-셀 구조로 길고 휘어지게 제작함으로써 기본적인 길이 방향, 수직방향 그리고 수평방향에 더불어 추가적으로 뒤틀리는 방향에서 출력 전압을 얻을 수 있다. 미소 전력원으로 실용적인 사용을 위해서 무게추가 더 무거워지고, PZT 박막이 더 두꺼워진다면 소자의 성능이 향상되어 높은 출력 전압을 얻을 수 있을 것이라 기대한다.

  • PDF

A Study on Wafer-Level 3D Integration Including Wafer Bonding using Low-k Polymeric Adhesive (저유전체 고분자 접착 물질을 이용한 웨이퍼 본딩을 포함하는 웨이퍼 레벨 3차원 집적회로 구현에 관한 연구)

  • Kwon, Yongchai;Seok, Jongwon;Lu, Jian-Qiang;Cale, Timothy;Gutmann, Ronald
    • Korean Chemical Engineering Research
    • /
    • v.45 no.5
    • /
    • pp.466-472
    • /
    • 2007
  • A technology platform for wafer-level three-dimensional integration circuits (3D-ICs) is presented, and that uses wafer bonding with low-k polymeric adhesives and Cu damascene inter-wafer interconnects. In this work, one of such technical platforms is explained and characterized using a test vehicle of inter-wafer 3D via-chain structures. Electrical and mechanical characterizations of the structure are performed using continuously connected 3D via-chains. Evaluation results of the wafer bonding, which is a necessary process for stacking the wafers and uses low-k dielectrics as polymeric adhesive, are also presented through the wafer bonding between a glass wafer and a silicon wafer. After wafer bonding, three evaluations are conducted; (1) the fraction of bonded area is measured through the optical inspection, (2) the qualitative bond strength test to inspect the separation of the bonded wafers is taken by a razor blade, and (3) the quantitative bond strength is measured by a four point bending. To date, benzocyclobutene (BCB), $Flare^{TM}$, methylsilsesquioxane (MSSQ) and parylene-N were considered as bonding adhesives. Of the candidates, BCB and $Flare^{TM}$ were determined as adhesives after screening tests. By comparing BCB and $Flare^{TM}$, it was deduced that BCB is better as a baseline adhesive. It was because although wafer pairs bonded using $Flare^{TM}$ has a higher bond strength than those using BCB, wafer pairs bonded using BCB is still higher than that at the interface between Cu and porous low-k interlevel dielectrics (ILD), indicating almost 100% of bonded area routinely.

Application of the Homogenization Analysis to Calculation of a Permeability Coefficient (투수계수 산정을 위한 균질화 해석법의 적응)

  • 채병곤
    • Journal of Soil and Groundwater Environment
    • /
    • v.9 no.1
    • /
    • pp.79-86
    • /
    • 2004
  • Hydraulic conductivity along rock fracture is mainly dependent on fracture geometries such as orientation, aperture, roughness and connectivity. Therefore, it needs to consider fracture geometries sufficiently on a fracture model for a numerical analysis to calculate permeability coefficient in a fracture. This study performed new type of numerical analysis using a homogenization analysis method to calculate permeability coefficient accurately along single fractures with several fracture models that were considered fracture geometries as much as possible. First of all, fracture roughness and aperture variation due to normal stress applied on a fracture were directly measured under a confocal laser scaning microscope (CLSM). The acquired geometric data were used as input data to construct fracture models for the homogenization analysis (HA). Using the constructed fracture models, the homogenization analysis method can compute permeability coefficient with consideration of material properties both in microscale and in macroscale. The HA is a new type of perturbation theory developed to characterize the behavior of a micro inhomogeneous material with a periodic microstructure. It calculates micro scale permeability coefficient at homogeneous microscale, and then, computes a homogenized permeability coefficient (C-permeability coefficient) at macro scale. Therefore, it is possible to analyze accurate characteristics of permeability reflected with local effect of facture geometry. Several computations of the HA were conducted to prove validity of the HA results compared with the empirical equations of permeability in the previous studies using the constructed 2-D fracture models. The model can be classified into a parallel plate model that has fracture roughness and identical aperture along a fracture. According to the computation results, the conventional C-permeability coefficients have values in the range of the same order or difference of one order from the permeability coefficients calculated by an empirical equation. It means that the HA result is valid to calculate permeability coefficient along a fracture. However, it should be noted that C-permeability coefficient is more accurate result than the preexisting equations of permeability calculation, because the HA considers permeability characteristics of locally inhomogeneous fracture geometries and material properties both in microscale and macroscale.