• Title/Summary/Keyword: 연결관

Search Result 490, Processing Time 0.025 seconds

A Study for Drainage Pipe Construction Method using a Boring Machine (천공장치를 이용한 배수설비 연결관 시공 기술에 관한 연구)

  • Chang, Jae-Goo;Kang, Seon-Hong;Kim, Dong-Eun;Jung, Tae-Ho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.6
    • /
    • pp.869-875
    • /
    • 2011
  • Ministry of Environment has been promoting BTL business of the sewer rehabilitation which continues from 2005 up to now. Sewer rehabilitation is classified into three parts : wastewater pipe rehabilitation, rainwater pipe rehabilitation and drainage equipment rehabilitation. Drainage equipment rehabilitation is that drainage pipe connects wastewater pipe directly without water-purifier. In the drainage equipment construction, it is inevitable to have the damage of ground structures(wall, gate and U drain, etc) when an open excavation method is used. Therefore it is necessary to develop non-excavation method to connect drainage pipe and wastewater pipe like jacking method to avoid the damage of ground structure. This paper has conducted an analysis of the non-excavation method using a boring machine attached to backhoe, which is issued the verification certificate of environmental technology according to the Development of and Support for Environmental Technology Act, article.7. The index set in this analysis was sectionalized to the condition of construction, the grade of drainage pipe, the size of excavated hole, the amount of waste cement concrete and asphalt concrete and the benefit effect compared to open excavation method.

A research on the design parameters for a double-transmission main system for sustainable water supply (이중송수관로를 이용한 안정적인 송수를 위한 설계인자에 관한 연구)

  • Hyun, Inhwan;Hong, Juneui;Kim, Dooil
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.1
    • /
    • pp.129-138
    • /
    • 2013
  • Water interruption is often caused by a rupture in the branch-like singular pipeline. This will cause critical complaints from household and may decrease public service quality. As an alternative of singular pipeline, additional parallel pipeline could be installed for sustainable water supply. This system is called double pipeline system and able to be utilized for water transmission line between treatment plant and distribution reservoir. Construction of double pipeline was thought to increase capital cost, which can be an issue to waterworks authorities. Reducing capital cost was possible by means of installing connectors between two parallel pipelines because of reduced diameter of each pipe. To obtain optimal design condition for connectors, it was necessary to compare water pressure according to accident location, to investigate flow according to connection pipe spacing, connection pipe diameter, and aging of pipe. Reliable and economical connection layouts were determined based on these results. The cost estimation for each design condition was carried out. Cost was approximately reduced by 20 ~ 30 % compared to the double pipeline without connections. In addition to this, connection between double pipelines could expect extra benefits for maintenance since the pipe could be repaired and rehabilitated without interruption.

Electromagnetic Indirect Induction Fluid Heating System using Series Resonant PWM Inverter and Its Performance Evaluations (직렬공진 PWM인버터를 이용한 전자간절유도가열 열유체 에너지시스템과 그 성능평가)

  • 김용주;김기환;신대철
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.7 no.1
    • /
    • pp.48-54
    • /
    • 2002
  • This paper is described the indirect induction heated boiler and induction heated hot air producer using the voltage-fed series resonant high-frequency inverter which can operate in the frequency range from 20 kHz to 50 kHz. A specially designed induction heater is composed of laminated stainless plates, which have many tiny holes and are interconnected by spot welding. This heater is inserted into the ceramic type vessel with external working coil. This working coil is connected to the inverter and turbulence fluid through this induction heater to moving fluid generates in the vessel. The operating performances of this unique appliance in next generation and its effectiveness are evaluated and discussed from a practical point of view.

Bilateral Sequential Single Lung Transplantation for Eisenmenger's Syndrome (Eisenmenger's 증후군이 동반된 동맥관 개존증환자에서의 순차적 양측 폐이식술 - 1례 보고 -)

  • 이교준;정은규;함석진;이두연;백효채;김해균;조현민
    • Journal of Chest Surgery
    • /
    • v.35 no.1
    • /
    • pp.64-67
    • /
    • 2002
  • Eisenmenger's syndrome is the disease of right to left shunt developing from the increased pulmonary vascular resistance caused by excessive pulmonary blood flow in patients with abnormal connections of systemic to pulmonary blood passage. The heart-lung transplantation was the only curative method in early transplantation period, but good results after bilateral lung transplantation have been reported as the fact that right heart function improved by only lung transplantation. We successfully carried out bilateral sequential single lung transplantation in a 34-year-old female patient with Eisenmenger's syndrome with large PDA. We report this case with a brief review of the literature.

A Study on method to construct system for u-Safe fire management support (u-Safe 소방대응지원 시스템 구축방안에 관한 연구)

  • Jeon, Jai-Pil;Yang, Hae-Sool
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.5
    • /
    • pp.1201-1209
    • /
    • 2008
  • In Seoul, there are lots of skyscrapers that have above 60 stories and buildings that have more than 8 basement levels, as well as massive distribution complex region which is connected to subways, departments, malls, hotels, and exhibition halls. When an accident, such as fire and explosion, happens in these areas or structures, if we can't find where fire-fighters are, who go into the building to suppress the fire, we couldn't be sure of their safety as well as effective command. Actually, it may cause much more damage itself and restrict either fire suppression or lifesaving. To protect people's life and properties as much as possible, this study will show the method to construct system of disaster-management supports with effective operation of fire force and scientific fire strategy in the scene by using Ubiquitous technique to enormous disasters.

A Study on the Operating Characteristics by Counter Flow and Parallel Flow in Separate Heat Pipe Exchanger (분리형 히트파이프식 열교환기에서 향류 및 병류유동에 따른 가동특성에 관한 연구)

  • 이기우;장기창;유성연
    • Journal of Energy Engineering
    • /
    • v.7 no.1
    • /
    • pp.44-56
    • /
    • 1998
  • Separate heat pipe exchanger is considered as the high thermal transportation equipment, because evaporator and condenser are separately positioned in the long distance. Its characteristics are that the working fluid is circulated naturally by the position height of two exchangers. But the operating characteristics are restricted by the temperature of hot and cold fluid, flow pattern and diameter of vapor line, etc. in this study, the vapor pressure and the minimum height of two exchangers are studied about the factors restricting the operating characteristics.

  • PDF

Morphological and Histochemical Study on the Female Reproductive Organs in a Korean Slug, Incilaria fruhstorferi (산민달팽이 ( Incilaria fruhstorferi ) 의 자성 생식기관의 형태 및 조직화학적 연구)

  • Chang, Nam-Sub;Jeong, Kye-Heon
    • The Korean Journal of Malacology
    • /
    • v.11 no.2
    • /
    • pp.123-134
    • /
    • 1995
  • 한국산 산민달팽이 (Incilaria fruhstorferi)의 자성 생식기관을 조직화학적 방법을 이용, 광학현미경으로 관찰한 결과는 다음과 같다. 알부민선(albumen gland)은 대자웅동체관 위에 있으며, 산성 점액다당류와 중성 점액다당류 그리고 단백질성 분비물을 형성하는 세포들로 구성되어 있었다. 수정실(fertilization chamber)을 구성하는 내강 상피는 불규칙한 단층섬모원주상피와 위중층섬모원주상피세포가 3대 1의 비율로 구성되어 있으며, 결합조직에서 형성된 산성점액다다류성 과립들이 상피세포를 거쳐 내강 속으로 분비되었다. 또한 수정실의 외측표면은 기능은 알 수 없으나 산성 점액다당류를 분비하는 대형 세포들로 둘러싸여 있었다 . 수란관(oviduct)의 내강은 크로 작은 돌기로 인해 별모양을 나타내었다. 내강은 위중층원주상피세포로 구성되었으며 그들 사이에서 분비세포의 존재는 확인되지 않았다.질(vagina)의내강은 덮은 세포는 해면조직 형태의 세포와 단층섬모원주상피세포 그리고 위중층섬모원주상피세포 등 다양한 종류로 구성되어 있었으며, 잘 발달된 두터운 근육층은 질의 신축성을 높여 주었다. 정자낭(spermatheca)은 그 형태와 크기, 색깔 등이 종에 따라 다양하고, 질과 연결되는 자성생식기관으로 알려져 있다.

  • PDF

영광 3/4호기 Midloop 운전중 RHR 기능 상실사고시 CATHARE2 코드를 이용한 열수력 현상 해석 및 증기발생기 열제거 능력 평가

  • 김원석;하귀석;정재준;장원표;유건중
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1995.05a
    • /
    • pp.525-530
    • /
    • 1995
  • 최적 열수력 전산 코드인 CATHARE2 Vl.3u 코드를 이용하여 영광 3/4호기 midloop 운전중 잔열제거(RHR) 기능 상실사고를 해석하였다. 본 연구의 주된 목적은 사고시 계통에서 발생하는 열수력 현상의 이해 향상 및 증기발생기 열제거 능력 평가에 있다. 사고 복구 절차 관점에서 노심 비등, 노출 시점 및 계통압력 등이 중요한 인자이다. 본 계산 수행시 사용한 가정은 다음과 같다. 가) 초기 계통 수위는 고온관 중간에 위치하며 그 윗 부분은 질소 가스로 차 있다. 나) 3/4 인치 크기의 방출 밸브가 원자로 용기 상부 및 가압기 상부에 각각 설치되어 있으며, RHR 흡입구에 수위지시계가 설치되어 있다. 다) 증기발생기의 이차측은 U-튜브가 잠기도록 물로 차있다. 라) 두 증기발생기의 대기 방출 밸브(ADV)는 항상 열려 있어 사고시 이차측 압력을 대기압으로 유지하기에 충분하다. 사고는 원자로 정지 2일 후 발생하였다고 가정한다. 이와 같은 조건하에서 사고시 주된 계통 열제거 수단은 증기발생기 U-튜브내의 응축 작용이며 이는 전체 열제거량의 94%로 나타났다. 노심 비등 시점온 사고후∼300초 이후이며, 계통압력은 10,800초 이후에 최고 압력인 0.25MPa에 도달한 후 그 값을 계속 유지하고 있다. RHR 배관에 연결된 수위지 시계를 통해 10,200초 이후부터 냉각수가 방출되었다. 2개의 방출밸브 및 수위지시계를 통하여 방출된 유량에 근거하여 원자로 용기 냉각재 수위가 고온관 바닦까지 낮아지는 시점을 계산하면 사고 약 6.4 시간 이후가 된다.

  • PDF

Stress and Fatigue Evaluation of Distributor for Heat Recovery Steam Generator in Combined Cycle Power Plant (복합발전플랜트 배열회수보일러 분배기의 응력 및 피로 평가)

  • Lee, Boo-Youn
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.8
    • /
    • pp.44-54
    • /
    • 2018
  • Stress and fatigue of the distributor, an equipment of the high-pressure evaporator for the HRSG, were evaluated according to ASME Boiler & Pressure Vessel Code Section VIII Division 2. First, from the results of the piping system analysis model, reaction forces of the tubes connected to the distributor were derived and used as the nozzle load applied to the detailed analysis model of the distributor afterward. Next, the detailed model to analyze the distributor was constructed, the distributor being statically analyzed for the design condition with the steam pressure and the nozzle load. As a result, the maximum stress occurred at the bore of the horizontal nozzle, and the primary membrane stress at the shell and nozzle was found to be less than the allowable. Next, for the transient operating conditions given for the distributor, thermal analysis was performed and the structural analysis was carried out with the steam pressure, nozzle load, and thermal load. Under the transient conditions, the maximum stress occurred at the vertical downcomer nozzle, and of which fatigue life was evaluated. As a result, the cumulative usage factor was less than the allowable and hence the distributor was found to be safe from fatigue failure.

Improving the water network management using the GIS (GIS를 이용한 상수도 배수관망 최적관리 시스템에 관한 연구)

  • 전철민;구자용;고준환;김병화
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2003.10a
    • /
    • pp.275-279
    • /
    • 2003
  • 2002년 현재 서울시는 99.99%에 이르는 높은 상수도 보급율에 비하여 유수율은 선진국의 수준에 이르지 못하고 있는 실정이다. 이는 정수장에서 배수지까지 연결되는 송수관과 배수지에서 각 가정으로 보낼 때 사용되는 배급수관에서의 누수 발생이 주 원인이며, 이는 곧 체계적인 관망 설계 및 운영이 미흡하기 때문인 것으로 지적되고 있다. 상수관로의 누수현상을 해결하고 효과적인 관리를 위한 근본적인 대책으로 노후관로의 교체가 필요하게 된다. 또한 노후관망 교체 등 유사시에 안정적인 상수의 공급을 위해 배수지간을 연결하는 대안 관로를 둘 필요가 있으며, 이러한 관망의 경로를 적절하게 설계해야 하는 것도 주요한 상수 공급 문제 중의 하나이다. 2000년 서울시 수도 정비 기본 계획의 관망 정비계획에 따르면 배수관리를 원활하게 하고 누수를 효율적으로 탐지·방지하기 위한 가장 이상적인 관망구성은 배수지 중심의 블록 시스템으로 보고 있다. 이와 같은 문제점들을 기반으로 하여, 본 연구는 GIS를 이용하여 효과적으로 노후관망을 관리하고, 대안 관망경로를 구축하는 시스템을 제안하였다. 본 연구에서는 배수지를 중심으로 한 블록 단위기반의 관망 노후도를 체계적으로 분석하는 시스템과 함께, 유사시를 대비한 최단/최적의 대안 경로를 산출하는 시스템을 구현하여 이를 서울 일부지역에 적용하여 그 유용성을 점검하였다. 상수도 관망의 설치 계획은 상수도 시설의 규모의 확장과 시설계량에 있어 대규모의 비용과 시간이 요구되는 특성을 가지고 있기 때문에 시설투자에 있어 정확한 예측과 분석을 통해 이루어져야 한다. 본 연구에서는 이러한 예측과 분석의 의사결정을 지원할 수 있는 상수도 배수 블록 노후도 관리 시스템과 최단/최적 연결 경로 산출 시스템을 구현해 봄으로써 다음과 같은 결론을 얻었다. 1. 상수도의 관망 노후도의 분석을 화면상에서 다양한 요소별로 하게 함으로써 넓은 공간에서의 관망의 관리를 효과적으로 할 수 있게 해준다. 2. 또한 이와 함께 대안 관망들을 사용자가 직접 대화식으로 빠르게 설계하고 이들의 경로와 공사비용 등을 산출해 봄으로써, 후보 최적 경로들을 공간적, 정량적으로 비교하는 것이 용이하다.

  • PDF