• Title/Summary/Keyword: 역할인지

Search Result 29,888, Processing Time 0.06 seconds

Effects of Anti-thyroglobulin Antibody on the Measurement of Thyroglobulin : Differences Between Immunoradiometric Assay Kits Available (면역방사계수법을 이용한 Thyroglobulin 측정시 항 Thyroglobulin 항체의 존재가 미치는 영향: Thyroglobulin 측정 키트에 따른 차이)

  • Ahn, Byeong-Cheol;Seo, Ji-Hyeong;Bae, Jin-Ho;Jeong, Shin-Young;Yoo, Jeong-Soo;Jung, Jin-Hyang;Park, Ho-Yong;Kim, Jung-Guk;Ha, Sung-Woo;Sohn, Jin-Ho;Lee, In-Kyu;Lee, Jae-Tae;Kim, Bo-Wan
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.4
    • /
    • pp.252-256
    • /
    • 2005
  • Purpose: Thyroglobulin (Tg) is a valuable and sensitive tool as a marker for diagnosis and follow-up for several thyroid disorders, especially, in the follow-up of patients with differentiated thyroid cancer (DTC). Often, clinical decisions rely entirely on the serum Tg concentration. But the Tg assay is one of the most challenging laboratory measurements to perform accurately owing to antithyroglobulin antibody (Anti-Tg). In this study, we have compared the degree of Anti-Tg effects on the measurement of Tg between availale Tg measuring kits. Materials and Methods: Measurement of Tg levels for standard Tg solution was performed with two different kits commercially available (A/B kits) using immunoradiometric assay technique either with absence or presence of three different concentrations of Anti-Tg. Measurement of Tg for patient's serum was also performed with the same kits. Patient's serum samples were prepared with mixtures of a serum containing high Tg levels and a serum containg high Anti-Tg concentrations. Results: In the measurements of standard Tg solution, presence of Anti-Tg resulted in falsely lower Tg level by both A and B kits. Degree of Tg underestimation by h kit was more prominent than B kit. The degree of underestimation by B kit was trivial therefore clinically insignificant, but statistically significant. Addition of Anti-Tg to patient serum resulted in falsely lower Tg levels with only A kit. Conclusion: Tg level could be underestimated in the presence of anti-Tg. Anti-Tg effect on Tg measurement was variable according to assay kit used. Therefore, accuracy test must be performed for individual Tg-assay kit.

Influence of Age on The Adenosine Deaminase Activity in Patients with Exudative Pleural Effusion (연령의 증가가 삼출성 흉수 Adenosine Deaminase 활성도에 미치는 영향)

  • Yeon, Kyu-Min;Kim, Chong-Ju;Kim, Jeong-Soo;Kim, Chi-Hoon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.53 no.5
    • /
    • pp.530-541
    • /
    • 2002
  • Background : Pleural fluid adenosine deaminase (ADA) activity can be helpful in a differntial diagnosis of an exudative pleural effusion because it is increased in a tuberculous pleural effusion. The ADA activity is determined mainly by the lymphocyte function. Age-associated immune decline is characterized by a decrease in T-lymphocyte function. For that reason, the pleural fluid ADA level would be lower in older patients with exudative pleural effusion. This study focused on the influence of age on the pleural fluid ADA activity in patients with exudative pleural effusion. Methods : A total of 81 patients with exudative pleural effusion were enrolled in this study. In all patients, the pleural fluid ADA activity was measured using an automated kinetic method. Results : The mean age of the patients was $52.7{\pm}21.2$ years. In all patients with exudative pleural effusion, the pleural fluid ADA activity revealed a significant difference between young patients (under 65 years of age) and old patients (p<0.05), and showed a negative correlation with age (r=-0.325, p<0.05). In the 60 patients with a tuberculous pleural effusion, the pleural fluid ADA activity revealed a significant difference between the young and older patients : $103.5{\pm}36.9$ IU/L in young patients Vs. $72.2{\pm}31.6$ IU/L in old patients (p<0.05), and showed a negative correlation with age (r=-0.384, p<0.05). In the 21 patients with non-tuberculous exudative pleural effusion, the pleural fluid ADA activity of the young patients and old patients was similar : $23.7{\pm}15.3$ IU/L in young patients Vs. $16.1{\pm}10.2$ IU/L in old patients (p>0.05), and did not show any correlation with age (r=-0.263, p>0.05). The diagnostic cutoff value of pleural fluid ADA activity for tuberculous pleural effusion was lower in the older patients (25.9 IU/L) than in the younger patients (49.1 IU/L) or all patients (38.4 IU/L) with exudative pleural effusion. Conclusion : Tuberculous pleural effusion is an important possibility to consider in older patients with a clinical suspicion of a tuberculous pleural effusion, although no marked increase in the pleural fluid ADA activity is usually detected. For a diagnosis of a tuberculous pleural effusion in old patients, the cutoff for the pleural fluid ADA activity should be set lower.

The Demand and Supply of Nutritionist Workforce in Korea and Policy Recommendations (국민영양관리를 위한 영양사 인력의 적정수급에 관한 연구)

  • Oh, Young-Ho
    • Journal of Nutrition and Health
    • /
    • v.43 no.5
    • /
    • pp.533-542
    • /
    • 2010
  • The objective of this study is to provide basic information and policy implications needed to balance the supply and demand for dietitian by projecting supply and demand for dietitian. The data from the Ministry of Health Welfare and Family on the number of licensed nutritionist, resident registration data of the Ministry of Public Administration and Security, and health insurance qualification data of the National Health Insurance Corporation were used to examine the current status of supply. To project the supply of nutritionist workforce, the in-out moves method and demographic method were used. The ratios of nutritionist to population and GDP, and that of other countries were applied as the demand projection method. According to the study results, the projection on the imbalance of supply and demand for dietitian by year 2021 differs depending on the method used. First, according to the results based on age-adjusted population ratio, there is an oversupply of 1,643 dietitians in year 2010, and 2,076 dietitians in year 2020. Second, although the projection on the imbalance of the supply and demand for dietitian differs depending on whether the GDD is calculated in won(₩) or dollar($). it is expected that there will be an oversupply in general. Third, as to the scenario using the nutritionist ratio in foreign countries, the oversupply of dietitian is likely in Korea, under any scenario, when comparing the nutritionist supply projection with the demand projection based on the nutritionist ratio in the United States. However, the projection of the supply and demand varies in each scenario when the European nutritionist ratio is applied. Under European 'scenario 1', an oversupply is expected, whereas under 'scenario 2', a shortage of supply is expected. A careful approach is required in interpreting the supply and demand projection using criteria of other countries, because dietitian assumes different roles and functions in each country. Although a slight oversupply of nutritionist workforce is projected, it does not cause a major problem as the demand for diet therapy is expected to rise due to aging and the increase of chronic diseases, and as the demand for clinical dietitians in hospitals increases. Accordingly, the demand for dietitians will rise and, in this context, the oversupply of nutritionist will not incur much problem. However, the nutritionist qualification is much too open in Korea, and this has a negative effect on the quality of the nutritionist workforce. Therefore, it is important that the nutritionist qualifications and requirements are reinforced in the future, enhance the quality level of the nutritionist supply, and maintain the balance between the supply and demand.

A Study on the Factors Influencing Technology Innovation Capability on the Knowledge Management Performance of the Company: Focused on Government Small and Medium Venture Business R&D Business (기술혁신역량이 기업의 지식경영성과에 미치는 요인에 관한 연구: 정부 중소벤처기업 R&D사업을 중심으로)

  • Seol, Dong-Cheol;Park, Cheol-Woo
    • Asia-Pacific Journal of Business Venturing and Entrepreneurship
    • /
    • v.15 no.4
    • /
    • pp.193-216
    • /
    • 2020
  • Due to the recent mid- to long-term slump and falling growth rates in the global economy, interest in organizational structures that create new products or services as a new alternative to survive and develop in an opaque environment both internally and externally, and enhance organizational sustainability through changes in production methods and business innovation is increasing day by day. In this atmosphere, we agree that the growth of small and medium-sized venture companies has a significant impact on the national economy, and various efforts are being made to enhance the technological innovation capabilities of the members so that these small and medium-sized venture companies can enhance and sustain their performance. The purpose of this study is also to investigate how the technological innovation capabilities of small and medium-sized venture companies correlate with the performance of knowledge management and to analyze the role of network capabilities to organize the strategic activities of enterprise to obtain the resources and organizational capabilities to be used for value creation from external networks. In other words, research was conducted on the impact of technological innovation capabilities of small and medium venture companies on knowledge management performance by using network capabilities as parameters. Therefore, in this study, we would like to verify the hypothesis that innovation capabilities will have a positive impact on knowledge management performance by using network capabilities of small and medium venture companies. Economic activities based on technological innovation capabilities should respond quickly to new changes in an environment where uncertainty has increased, and lead to macro-economic growth and development as well as overcoming long-term economic downturns so that they can become the nation's new growth engine as well as sustainable growth and survival of the organization. In addition, this study was conducted by setting the most important knowledge management performance within the organization as a dependent variable. As a result, R&D and learning capabilities among technological innovation capabilities have no impact on financial performance. In contrast, it was shown that corporate innovation activities have a positive impact on both financial and non-financial performance. The fact that non-financial factors such as quality and productivity improvement are identified in the management of small and medium-sized venture companies utilizing their technological innovation capabilities is contrary to a number of studies by those corporate innovation activities affect financial performance during prior research. The reason for this result is that research companies have been out of start-up companies for more than seven years, but sales are less than 10 billion won, and unlike start-up companies, R&D and learning capabilities have more positive effects on intangible non-financial performance than financial performance. Corporate innovation activities have been shown to have a positive (+) impact on both financial and non-financial performance, while R&D and learning capabilities have a positive (+) impact on financial performance by parameters of network capability. Corporate innovation activities have been shown to have no impact on both financial and non-financial performance, and R&D and learning capabilities have no impact on non-financial performance. It could be seen that the parameter effects of network competency are limited to when R&D and learning competencies are derived from quantitative financial performance. It could be seen that the parameter effects of network competency are limited to when R&D and learning competencies are derived from quantitative financial performance.

[ $^1H$ ] MR Spectroscopy of the Normal Human Brains: Comparison between Signa and Echospeed 1.5 T System (정상 뇌의 수소 자기공명분광 소견: 1.5 T Signa와 Echospeed 자기공명영상기기에서의 비교)

  • Kang Young Hye;Lee Yoon Mi;Park Sun Won;Suh Chang Hae;Lim Myung Kwan
    • Investigative Magnetic Resonance Imaging
    • /
    • v.8 no.2
    • /
    • pp.79-85
    • /
    • 2004
  • Purpose : To evaluate the usefulness and reproducibility of $^1H$ MRS in different 1.5 T MR machines with different coils to compare the SNR, scan time and the spectral patterns in different brain regions in normal volunteers. Materials and Methods : Localized $^1H$ MR spectroscopy ($^1H$ MRS) was performed in a total of 10 normal volunteers (age; 20-45 years) with spectral parameters adjusted by the autoprescan routine (PROBE package). In all volunteers, MRS was performed in a three times using conventional MRS (Signa Horizon) with 1 channel coil and upgraded MRS (Echospeed plus with EXCITE) with both 1 channel and 8 channel coil. Using these three different machines and coils, SNRs of the spectra in both phantom and volunteers and (pre)scan time of MRS were compared. Two regions of the human brain (basal ganglia and deep white matter) were examined and relative metabolite ratios (NAA/Cr, Cho/Cr, and mI/Cr ratios) were measured in all volunteers. For all spectra, a STEAM localization sequence with three-pulse CHESS $H_2O$ suppression was used, with the following acquisition parameters: TR=3.0/2.0 sec, TE=30 msec, TM=13.7 msec, SW=2500 Hz, SI=2048 pts, AVG : 64/128, and NEX=2/8 (Signa/Echospeed). Results : The SNR was about over $30\%$ higher in Echospeed machine and time for prescan and scan was almost same in different machines and coils. Reliable spectra were obtained on both MRS systems and there were no significant differences in spectral patterns and relative metabolite ratios in two brain regions (p>0.05). Conclusion : Both conventional and new MRI systems are highly reliable and reproducible for $^1H$ MR spectroscopic examinations in human brains and there are no significant differences in applications for $^1H$ MRS between two different MRI systems.

  • PDF

Immunogenicity and Safety of a Haemophilus influenzae Type b Polysaccharide-Tetanus Toxoid Conjugate Vaccine (PRP-T: HiberixTM) in Korean Infants (우리나라 영아에서 PRP-T(HiberixTM)백신의 면역원성 및 안전성에 대한 연구)

  • Chung, Eun Hee;Kim, Yae Jean;Kim, Yun Kyung;Kim, Dong Ho;Seo, Jeong Wan;Lee, Hoan Jong
    • Pediatric Infection and Vaccine
    • /
    • v.10 no.1
    • /
    • pp.71-80
    • /
    • 2003
  • Purpose : Four kinds of Haemophilus influenzae type b protein conjugate vaccines, PRPD, PRP-T, PRP-OMP and PRP-CRM197, have been developed, and PRP-T vaccines are currently produced by two manufacturer, $ActHib^{(R)}$ by Aventis and $Hiberix^{TM}$ by GlaxoSmith-Kline Biologicals. The purpose of this study is to evaluate the immunogenicity and safety of $Hiberix^{TM}$ in Korean infants. Methods : Seventy-three healthy infants(43 male infants) were recruited for this study after parental informed consent was obtained. Each infant was vaccinated at 2, 4 and 6 months of age with the study vaccine. At each visit, infants were also immunized with DTaP, trivalent oral polio vaccine and hepatitis B vaccine when indicated. The serum anti-PRP antibody was measured at prevaccination, 2 month later after the 2nd dose, and 1 month later after the 3rd dose by the ELISA method. The local and systemic adverse reactions of vaccination were monitored for 3 consecutive days after each immunization. Immunogenicity of vaccine was evaluated in infants who received all the scheduled immunization and the adverse reactions were evaluated for infants who received at least one dose of the study vaccine. Results : Among seventy three infants, enrolled in this study; sixty three(37 male infants) completed all the scheduled immunizations. The geometric mean titer(GMT) of anti-PRP antibodies at prevaccination was 0.17 ${\mu}g/mL$(95% confidence interval[CI]; 0.13~0.22). The GMT of anti-PRP antibodies increased to 4.14 ${\mu}g/mL$(95% CI; 2.65~6.48) at 2 month later after the 2nd dose of PRP-T and 14.65 ${\mu}g/mL$(95% CI; 10.83~19.81) at 1 month later after the 3rd dose. Anti-PRP antibody ${\geq}0.15$ ${\mu}g/mL$, was observed in 98.4%(95% CI; 91.8~100) after 2 doses and 100%(95% CI; 100~100) after 3 doses. Anti-PRP antibody ${\geq}1.0$ ${\mu}g/mL$, was obtained in 77.8%(95% CI; 67.5~88.0) after 2 doses, and 98.4%(95% CI; 95.3~100) after 3 doses. Most of the adverse reaction after vaccination were mild. Irritability, the most common systemic reaction, was observed in 45.5%, followed by drowsiness(30.5%), poor feeding(26.7%) and fever(5.6%). Among the local reactions tenderness was observed in 7.9%, redness(${\geq}5$ mm) in 2.8% and swelling(${\geq}5$ mm) in 1.8%. Conclusion : The PRP-T vaccine used in this study was highly immunogenic and safe in Korean young infants. The finding that high GMT and high frequency of infants with a protective titer achieved after 2 doses is consistent with the previous studies which were done with a PRP-T vaccine of other manufacturer. This study suggests that the immunization schedule of PRP-T vaccine for Korean infants may need re-evaluation.

  • PDF

The Effects of Isopropyl 2-(1,3-dithioetane-2-ylidene)-2-[N-(4-methyl-thiazol-2-yl)carbamoyl]acetate (YH439) on Potentiated Carbon Tetrachloride Hepatotoxicity (상승적 화학적 간독성에 미치는 YH439의 영향)

  • Kim, Sang-Geon;Cho, Joo-Youn
    • The Korean Journal of Pharmacology
    • /
    • v.32 no.3
    • /
    • pp.407-416
    • /
    • 1996
  • The reactive intermediates formed during the metabolism of therapeutic agents, toxicants and carcinogens by cytochromes P450 are frequently capable of covalently binding to tissue macromolecules and causing tissue damage. It has been shown that YH439, a congener of malotilate, is effective in suppressing hepatic P450 2E1 expression. The present study was designed to further establish the mechanistic basis of YH439 protection against toxicant by assessing its effects against chemical-mediated potentiated hepatotoxicity. Retinoyl palmitate (Vit-A) pretreatment of rats for 7 days substantially enhanced carbon tetrachloride hepatotoxicity, as supported by an ${\sim}5-fold$ increase in serum alanine aminotransferase (ALT) activity, as compared to $CCl_4$ treatment alone. The elevation of ALT activity due to Vit-A was completely blocked by the treatment of $GdCl_3$ a selective inhibitor of Kupffer cell activity. Concomitant pretreatment of rats with both YH439 and Vit-A resulted in a 94% decrease in Vit-A-potentiated $CCl_4$ hepatotoxicity. YH439 was also effective against propyl sulfide-potentiated $CCl_4-induced$ hepatotoxicity. Whereas propyl sulfide (50 mg/kg, 7d) enhanced $CCl_4-induced$ hepatotoxicity by >5-fold, relative to $CCl_4$ treatment alone, concomitant treatment of animals with both propyl sulfide and YH439 at the doses of 100 and 200 mg/kg prevented propyl sulfide-potentiated $CCl_4$ hepatotoxicity by 35% and 90%, respectively. Allyl sulfide, a suppressant of hepatic P450 2E1 expression, completely blocked the propyl sulfide-enhanced hepatotoxicity, indicating that propyl sulfide potentiation of $CCl_4$ hepatotoxicity was highly associated with the expression of P450 2E1 and that YH439 blocked the propyl sulfide-enhanced hepatotoxicity through modulation of P450 2E1 levels. Propyl sulfide- and $CCl_4-induced$ stimulation of lipid peroxidation was also suppressed by YH439 in a dose-related manner, as supported by decreases in malonedialdehyde production. The role of P450 2E1 induction in the potentiation of $CCl_4$ toxicity and the effects of YH439 were further evaluated using pyridine as a P450 2E1 inducer. Pyridine pretreatment substantially enhanced the $CCl_4$ hepatotoicity by 23-fold, relative to $CCl_4$ alone. YH439, however, failed to reduce the pyridine-potentiated toxicity, suggesting that the other form(s) of cytochroms P450 inducible by pyridine, but not suppressible by YH439 treatment, may play a role in potentiating $CCl_4-induced$ hepatotoxicity. YH439 was capable of blocking cadmium chloride-induced liver toxicity in mice. These results demonstrated that YH439 efficiently blocks Vit-A-enhanced hepatotoxiciy through Kupffer cell inactivation and that the suppression of P450 2E1 expression by YH439 is highly associated with blocking of propyl sulfide-mediated hepatotoxicity.

  • PDF

A Study on Chinese Traditional Auspicious Fish Pattern Application in Corperate Identity Design (중국 전통 길상 어(魚)문양을 응용한 중국 기업의 아이덴티티 디자인 동향)

  • ZHANG, JINGQIU
    • Cartoon and Animation Studies
    • /
    • s.50
    • /
    • pp.349-382
    • /
    • 2018
  • China is a great civilization which is a combination of various ethnic groups with long history change. As one of these important components of traditional culture, the lucky shape has been going through the ideological upheaval of the history change of China. Up to now, it has become the important parts which can stimulate the emotion of Chinese nation. The lucky shape becomes the basis of the rich traditional culture by long history of the Chinese nation. Even say it is the centre of this traditional culture resource. The lucky shape is a way of expressing the Chinese history and national emotions. It is the important part of people's living habits, emotion, as well as the cultural background. What's more, it has the value of beliefs of Surname totem. Meanwhile, it also has the function of passing on information. The symbol of information finally was created by the being of lucky shape to indicate its conceptual content. There are various kinds of lucky shapes. It will have its limitations when researching all kinds of them professionally. So, here the lucky shape of FISH will be researched. The shape of fish is the first good shape created by the Chinese nation. It is about 6000 years. Its special shape and lucky meaning embody the peculiar inherent culture and intension of the Chinese nation. It's the important component of the Chinese traditional culture. The traditional shape of fish was focused on the continuation of history and the patterns recognition, etc. It seldom indicated the meaning of the shape into the using of the modern design. So by searching the lucky meaning & the way of fish shape, the purpose of the search is to explore the real analysis of value of the fish shape in the modern enterprise identity design. The way of search is through the development of the history, the evolvement and the meaning of lucky of the traditional fish shape to analyse the symbolic meaning and the cultural meaning from all levels in nation, culture, art and life, etc. And by using the huge living example of the enterprise identity design of the traditional shape of the fish to analyse that how it works in positive way by those enterprise which is based on the trust with good image. In the modern Chinese enterprise identity design, the lucky image will be reinterpreted in the modern way. It will be proofed by the national perceptual knowledge of the consumer and the way of enlarge the goodwill of corporate image. It will be the conclusion. The traditional fish shape is the important core of modern design.So this search is taken through the instance of the design of enterprise image of the traditional fish shape to analysis the idea of the majority Chinese people of the traditional luck and the influence of corporation which based on trust and credibility. In modern image design of Chinese corporation, the auspicious sign reappear. The question survey is taken by people through the perceptual knowledge of the consumer and the cognition the enterprise image. According the result, people can speculate the improvement of consumer's recognition and the possibility of development of traditional concept.

Energy expenditure measurement of various physical activity and correlation analysis of body weight and energy expenditure in elementary school children (일부 초등학생의 대표적 신체활동의 에너지소비량 측정 및 에너지소비량과 체중과의 상관성 분석)

  • Kim, Jae-Hee;Son, Hee-Ryoung;Choi, Jung-Sook;Kim, Eun-Kyung
    • Journal of Nutrition and Health
    • /
    • v.48 no.2
    • /
    • pp.180-191
    • /
    • 2015
  • Purpose: There is a lack of data on the energy cost of children's everyday activities, adult values are often used as surrogates. In addition, the influence of body weight on the energy cost of activity when expressed as metabolic equivalents (METs) has not been vigorously explored. Methods: In this study 20 elementary school students 9~12 years of age completed 18 various physical activities while energy expenditure was measured continuously using a portable telemetry gas exchange system ($K_4b^2$, Cosmed, Rome, Italy). Results: The average age was 10.4 years and the average height and weight was 145.1 cm and 43.6 kg, respectively. Oxygen consumption ($VO_2$), energy expenditure and METs at the time of resting of the subjects were 5.41 mL/kg/min, 1.44 kcal/kg/h, and 1.5 METs, respectively. METs values by 18 physical activities were as follows: Homework and reading books (1.6 METs), playing game with a mobile phone or video while sitting (1.6 METs), watching TV while sitting on a comfortable chair (1.7 METs), playing video game or mobile phone game while standing (1.9 METs), sweeping a room with a broom (2.7 METs) and playing a board game (2.8 METs) belong to light intensity physical activities. By contrary, speedy walking and running were 6.6 and 6.7 METs, respectively, which belong to high intensity physical activities over 6.0 METs. When the effect of body weight on physical activity energy expenditure was determined, $R^2$ values increased with 0.116 (playing a game at sitting), 0.176 (climbing up and down stairs), 0.246 (slow walking), and 0.455 (running), which showed that higher activity intensity increased explanation power of body weight on METs value. Conclusion: This study is important for direct evaluation of energy expenditure by physical activities of children, and it could be used directly for revising and complementing the existing activity classification table to fit for children.

A Study on measurement of scattery ray of Computed Tomography (전산화 단층촬영실의 산란선 측정에 대한 연구)

  • Cho, Pyong-Kon;Lee, Joon-Hyup;Kim, Yoon-Sik;Lee, Chang-Yeop
    • Journal of radiological science and technology
    • /
    • v.26 no.2
    • /
    • pp.37-42
    • /
    • 2003
  • Purpose : Computed tomographic equipment is essential for diagnosis by means of radiation. With passage of time and development of science computed tomographic was developed time and again and in future examination by means of this equipment is expected to increase. In this connection these authors measured rate of scatter ray generation at front of lead glass for patients within control room of computed tomographic equipment room and outside of entrance door for exit and entrance of patients and attempted to ind out method for minimizing exposure to scatter ray. Material and Method : From November 2001 twenty five units of computed tomographic equipments which were already installed and operation by 13 general hospitals and university hospitals in Seoul were subjected to this study. As condition of photographing those recommended by manufacturer for measuring exposure to sauter ray was use. At the time objects used DALI CT Radiation Dose Test Phantom fot Head (${\oint}16\;cm$ Plexglas) and Phantom for Stomache(${\oint}32\;cm$ Plexglas) were used. For measurement of scatter ray Reader (Radiation Monitor Controller Model 2026) and G-M Survey were used to Survey Meter of Radical Corporation, model $20{\times}5-1800$, Electrometer/Ion Chamber, S/N 21740. Spots for measurement of scatter ray included front of lead glass for patients within control room of computed tomographic equipment room which is place where most of work by gradiographic personnel are carried out and is outside of entrance door for exit and entrance of patients and their guardians and at spot 100 cm off from isocenter at the time of scanning the object. The results : Work environment within computed tomography room which was installed and under operation by each hospital showed considerable difference depending on circumstances of pertinent hospitals and status of scatter ray was as follows. 1) From isocenter of computed tomographic equipment to lead glass for patients within control room average distance was 377 cm. At that time scatter ray showed diverse distribution from spot where no presence was detected to spot where about 100 mR/week was detected. But it met requirement of weekly tolerance $2.58{\times}10^{-5}\;C/kg$(100 mR/week). 2) From isocenter of computed tomographic equipment to outside of entrance door where patients and their guardians exit and enter was 439 cm in average, At that time scatter ray showed diverse distribution from spot where almost no presence was detected to spot with different level but in most of cases it satisfied requirement of weekly tolerance of $2.58{\times}10^{-6}\;C/kg$(100 mR/week). 3) At the time of scanning object amount of scatter ray at spot with 100 cm distance from isocenter showed considerable difference depending on equipments. Conclusion : Use of computed tomographic equipment as one for generation of radiation for diagnosis is increasing daily. Compared to other general X-ray photographing field of diagnosis is very high but there is a high possibility of exposure to radiation and scatter ray. To be free from scatter ray at computed tomographic equipment room even by slight degree it is essential to secure sufficient space and more effort should be exerted for development of variety of skills to enable maximum photographic image at minimum cost.

  • PDF