Performance Improvement Technology on a Continuous Heating Heat Pump at Frost Condition (착상조건에서 연속난방이 가능한 히트펌프 성능 향상 기술)

  • Jeon, Chang-Duk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.2
    • /
    • pp.573-577
    • /
    • 2013
  • Heat pumps come into wide use because high energy efficiency can be obtained and diverse heat sources like geothermal heat, waste heat and air are available. It is necessary for an air source heat pump to defrost in order to remove frost on the surfaces of an outdoor heat exchanger. It is impossible for continuous heating if reverse cycle operation is used as defrosting method, furthermore it causes the degradation of COP. In this study an fin-tube heat exchanger with three rows was used as an outdoor coil. One row among three rows of the heat exchanger was used like a condenser in order to remove frost on it, the others were used as evaporator to accomplish continuous heating. Each row was switched in order from a condenser to an evaporator in specified time interval. Tests were carried out during minimum 180 minutes at the defrost-heating test condition(dry bulb temperature $2^{\circ}C$, wet bulb temperature $1^{\circ}C$) described in KS C 9306. Time-averaged COP was about 20% higher than that of conventional defrosting method.

지진하중하의 안전성평가를 위한 파괴저항 특성 평가

  • 원종일;김수용;박종주;한지원;우흥식;석창성
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 1997.11a
    • /
    • pp.15-24
    • /
    • 1997
  • 최근 우리나라에도 많은 지진사례가 보고되고 있으며, 이러한 지진하중은 원전설비 및 각종 기계설비등의 가동중 파손을 유발시킬 수 있는 잠재적 위험성이 높다. 이에 지진하중에 대한 안전성 확보의 필요성이 점차 대두되고 있다. 지진하중은 종ㆍ횡파에 의한 인장ㆍ압축이 반복되는 역사이클하중(reverse cyclic loading)형태로, 현재까지는 이를 고려한 설계개념이 미흡한 실정이며 이에 대한 파괴물성치의 확보는 물론 파괴물성치 평가 절차도 확립되어 있지 않은 상태이다. 따라서 지진하중에 대한 안전성확보를 위해서는, 역사이클 하중이 재료의 파괴특성 특히, 파괴저항(J-R)곡선에 미치는 영향이 고찰되어야 할 것이다. (중략)

  • PDF

Experimental Study of a High Efficiency Transport Refrigeration Container under Cooling and Defrosting Conditions (고효율 냉동 컨테이너의 냉각 및 제상 실험)

  • Mun, Je-Cheol;Ardiyansyah, Ardiyansyah;Choi, Kwang-Il;Oh, Jong-Taek
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.277-281
    • /
    • 2008
  • This paper presents the development of a high efficiency transport refrigeration system for sliced-raw fish transportation. The refrigeration system is equipped with heat storage for reverse cycle-hot gas defrost (the stored heat is used during defrost cycle of the system). System performance and container operating conditions are analyzed during experimental investigation on a $3,225{\times}1,740{\times}1,640\;mm$ full-scale refrigerated container under cooling and defrosting conditions. The prototype system indicates better performance in terms of shorter cooling-down time, shorter defrost time and smaller fluctuations of refrigerated container's temperature.

  • PDF

Cooling Characteristics of Refrigerated Vehicles with Heat Storage Materials in Thermobank (냉동탑차의 Thermobank 열저장 매체에 따른 냉각성능 비교)

  • Mun, Je-Cheol;Choi, Kwang-Il;Oh, Jong-Taek;Kim, Jai-Hoon
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.810-814
    • /
    • 2009
  • A experimental study of a high efficiency transport refrigeration system for sliced-raw fish transportation is presented in this paper. The refrigeration system, that is powered by the car engine, is equipped with heat storage for reverse cycle-hot gas defrost; the stored heat is used during defrost cycle of the system. The heat storage has size $400(L){\times}350(W){\times}250(H)\;mm$ and made of fin-tube heat exchanger. System performance and container operating conditions are experimentally investigated and analyzed under cooling and defrosting conditions with heat storage materials. The water is faster about 30% than paraffin in cooling-down time of heat storage materials with load and unload.

  • PDF