• 제목/요약/키워드: 역률보상

검색결과 179건 처리시간 0.041초

A Reactive Power Compensation Monitoring System for Factory Electrical Installation Using Active Database (능동 데이터베이스 기반 무효전력 보상장치 감시제어 시스템)

  • Choi, Sang-Yule
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • 제12권4호
    • /
    • pp.189-194
    • /
    • 2012
  • The main purpose of reactive power compensation monitoring system is to manage factory electrical installation efficiently by On-Off switching reactive power compensation equipment. The existing reactive power compensation monitoring system is only able to be managed by operator whenever electrical installation needed reactive power. Therefore, it may be possible for propagating the installation's faults when operator make the unexpected mistakes. To overcome the unexpected mistakes, in this paper, the author presents a reactive power compensation monitoring system for factory electrical installation using active database. by using active database production rule, stated system can minimize unexpected mistake and can operate centralized monitoring system efficiently. Test results on the five factory electrical installations show that performance is efficient and robust.

Development ±100[Mvar] static var compensation system model using PSCAD (±100[Mvar] 정지형 무효전력 보상설비 모델 개발)

  • Choi, Ho-Seok
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.211-212
    • /
    • 2015
  • 전압 안정도를 향상 시키고 무효전력을 보상하는 방법 중 하나로 정지형 무효전력보상설비(SVC, Static Var Compensator)를 사용한다. 특히, 전기로(EAF, Electric Arc Furnace) 등 비선형 부하가 주를 이루는 철강 민수 사업자의 부하는 단시간 내에 전류 변화가 급격히 일어나며 큰 전압 변동을 일으키므로 무효전력 보상설비를 적용하여 안정적인 전력을 공급하고 전력 품질을 확보해야 할 필요가 있다. 본 논문에서는 LS-Nikko 동제련 온산 공장에 역률 보상을 목적으로 무효전력을 제어하기 위한 ${\pm}100[MVar]$ SVC 시스템 모델을 소개하고, 그 특성에 대한 이해를 돕고자 한다.

  • PDF

Development reactive power compensation system model for power factor (역률제어용 무효전력 보상설비 모델 개발)

  • Choi, Ho-Seok
    • Proceedings of the KIPE Conference
    • /
    • 전력전자학회 2015년도 전력전자학술대회 논문집
    • /
    • pp.423-424
    • /
    • 2015
  • 전압 안정도를 향상 시키고 무효전력을 보상하는 방법 중 하나로 정지형 무효전력보상설비(SVC, Static Var Compensator)를 사용한다. 특히, 전기로(EAF, Electric Arc Furnace) 등 비선형 부하가 주를 이루는 철강 민수 사업자의 부하는 단시간 내에 전류 변화가 급격히 일어나며 큰 전압 변동을 일으키므로 무효전력 보상설비를 적용하여 안정적인 전력을 공급하고 전력 품질을 확보해야 할 필요가 있다. 본 논문에서는 LS-Nikko 동제련 온산 공장에 역률 보상을 목적으로 무효전력을 제어하기 위한 ${\pm}100[MVar]$ SVC 시스템 모델을 소개하고, 그 특성에 대한 이해를 돕고자 한다.

  • PDF

A Study on Solution and a Drop of Power Factor according to a Change of Power Network (전력계통변경에 따른 수력발전소 수전역률저하와 그 대책에 관한 연구)

  • Yoon, Jong-Beom;Choi, Jang-Geon;Oh, Bong-Rok;Ok, Kwang-Seok;Park, Kyung-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.287-289
    • /
    • 2003
  • 합천수력발전소는 1989년 준공이후 최근까지는 발전정지시 전력계통으로부터 전력을 수전할 경우 수전역률이 90%이상되어 문제가 없었으나, 2001년 6월경 전력계통이 논공154kV변전소에서 고령345kV변전소로 변경된 이후, 계통전압이 평균 $2.5{\sim}3.0kV$상승함으로써 역률이 약70%로 저하하였다. 이런 전압상승은 전력계통의 무효전력조정에 의한 것으로, 수전시 합천수력발전소의 평균소비전력은 주변압기 용량의 약0.55%로 전력계통에서 발전소를 바라보면 주변압기가 무부하로 운전되는 것처럼 보이게 되어 발전소내에서 소비되는 무부하손이 증가하여 역률이 저하한 것으로 검토되었다. 이런 무효전력소비는 주변압기에만 국한되어 있으므로 역률개선용 콘덴서를 주변압기 1차측에 설치하여 저하된 역률을 보상할 수 있었다.

  • PDF

A Study on PFC of Active Clamp ZVS Flyback Converter (능동 클램프 ZVS 플라이백 컨버터의 역률개선에 관한 연구)

  • 최태영;류동균;이우석;안정준;원충연;김수석
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • 제15권6호
    • /
    • pp.49-57
    • /
    • 2001
  • This paper analyzed PFC of active clamp ZVS flybark converter by adding two method PFC (Power Factor Correction) circuit-two-stage and single-stage. The addition of active clamp circuit also provide a mechanism fur achieving ZVS of both the primary and auxiliary switches. ZVS also limits the turn off di/dt of the output rectifier, reducing rectifier switching loss and switching noise, due to diode reverse recovery. As a results, the proposed converters have characteristics of the reduced switching noise and high efficiency in comparison to conventional flyback converter. The simulation and experimental results show that the proposed converters improve the input PF of 300[W] ZVS flyback converter by adding single-stage two-stage PFC circuit.

  • PDF

직렬(直列)콘텐서 보상 송전선(送電線)의 운전특성(運轉特性)

  • Kim, Jun-Hyeon;Park, Geon-Su
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 1979년도 하계 전자.전기연합학술발표회논문집
    • /
    • pp.142-146
    • /
    • 1979
  • 전력용(電力用) 병렬(竝列) 콘덴서는 변전소(變電所)에서 설치되어 계통(系統)의 전압조정 및 역률개선에 사용되어 왔으며 콘덴서의 원-용(元-用) 범위를 송전전선(送電電線)의 직렬(直列)보상에까지 활용하게 되어 선로의 운용도(云誘導) reactance를 보상함으로서 등가적으로 선로의 길리을 단축시키게 되어 장거리, UHV 손전선(送電線) 및 배전선(配電線)에 채용(採用)되고 있다. 본(本) 연구는 각국에서 채용되고 있는 직렬(直列)콘덴서 보상방식을 우리나라의 모델 선로에 적용시켰을 경우에 대한 전압(電壓), 전류(電流) 전력(電力) 및 전력손실(電力損失) 등의 제특성에 대하여 고찰한 결과이다.

  • PDF

Gyrator-Based Analyses of Resonant Circuits in Inductive Power Transfer Systems (자이레이터를 이용한 자기유도 전력전달시스템의 공진 회로 해석)

  • Sohn, Yeong H.;Choi, Bo H.;Cho, Gyu-Hyeong;Rim, Chun T.
    • Proceedings of the KIPE Conference
    • /
    • 전력전자학회 2015년도 전력전자학술대회 논문집
    • /
    • pp.17-18
    • /
    • 2015
  • 본 논문에서는 자이레이터를 사용하여 자기유도 전력전달시스템(IPTS)의 보상 회로를 해석하는 방식을 제안한다. 보상회로를 주로 구성하는 갖가지 공진 회로와 유도 결합 코일이 자이레이터의 특성을 가지고 있음을 보인다. 그러므로, 자이레이터의 바람직한 특성들을 보상 회로의 전원-로드 이득, 전원의 역률 등을 해석하는데 사용할 수 있음을 보인다. 제안된 해석 방식은 적용이 간편하고 서로 다른 보상 회로에도 동일한 형태로 적용된다는 장점이 있다.

  • PDF

Power Factor Correction of Single-phase PWM Converter using Third Harmonic Injection (3차 고조파 주입에 의한 단상 PWM컨버터의 고역률 제어)

  • 손진근;유성식;김병진;박종찬;전희종
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • 제13권3호
    • /
    • pp.25-33
    • /
    • 1999
  • In this paper, the method of reducing hanmnics and correcting of power factor in single PWM converter associated with diode rectifier and boost converter is studied. In the general diode rectifier there are sorre problems that discontinuous current of reducing power factor and including distortion of hanmnics at the input current affects other sources. To solve the problems of performance degradation due to pulse wavefonn in the input current, the ac-dc converter in which the hanmnic distortion in the input current is reduced using a third-hanmnic-injected PWM is proposed. A lower power loss of switching and easy configuration of circuit are obtained by adopting discontinuous current mode. Simulation and experimental results of ac-dc converter with 5[kHz] switching frequency are presented and correction of power factor and reduction of total hanmnic distortion was established.lished.

  • PDF

Characteristic Analysis by the Position of Power Factor Compensative Condenser (역률 보상용 콘덴서 설치 지점에 따른 특성 해석)

  • Jeong, Jin-Gwan;Lee, Gyeong-Bae;An, Hu-Jae;Kim, Jong-Gyeum
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.748-749
    • /
    • 2008
  • 대용량 전동기에는 역률보상용 콘덴서와 리액터를 설치하여 부하역률을 개선하고 있다. 역률보상용 콘덴서의 기동리액터 전.후단 설치지점에 따른 특성변화를 해석한 결과 콘덴서를 기동 리액터 전단에 설치한 경우 기동시의 순간적인 콘덴서 돌입전류로 상용주파수 부근의 고조파(1,3,5차) 공진이 발생하여 이로 인한 과전압이 콘덴서와 직렬리액터에 반복적으로 인가되어 수명이 단축됨을 확인할 수 있었다. 기동초기에 발생하는 과전압을 저감하기 위해서 콘덴서 회로의 연결점을 기동리액터 후단에 설치한 결과 인가전압과 전류가 감소됨을 알 수 있었다.

  • PDF