• Title/Summary/Keyword: 여과 기공 크기

Search Result 43, Processing Time 0.025 seconds

Technical Feasibility for Hollow-Fiber Ultrafiltration Water Treatment System and its Economic Aspects (중공사형 한외여과막 수처리 공정의 기능성과 막을 사용한 수처리공정의 경제성에 관한 연구)

  • Wang, Jin-Soo;Kim, Byung-Jick;Choi, Soo Hyoung
    • Applied Chemistry for Engineering
    • /
    • v.10 no.1
    • /
    • pp.12-18
    • /
    • 1999
  • This research was undertaken to do the technical and economical feasibility study of membrane water treatment system. For the technical feasibility study, batch water treatment system using UF(ultrafiltration) was set up and several experiments were carried out. The performance of the UF membrane was tested in terms of turbidity. The experimental results showed that the UF membrane process produced less than 1 NTU water regardless of input water turbidity. For the economical feasibility study, the cost model was analyzed and programmed for simulation. Also costs of the membrane water treatment and the conventional treatment were evaluated. The simulation results showed that the unit production cost increased when design flow or permeate flow decreased. The production cost of membrane water treatment system was lower than that of the conventional system. Both technical and economical feasibility study showed that the UF membrane water purification system was a very competitive water purification process.

  • PDF

The Effective Recovery of Gold from the Invisible Gold Concentrate Using Microwave-nitric Acid Leaching Method (마이크로웨이브-질산침출방법에 의한 비가시성 금의 회수율 향상)

  • Lee, Jong-Ju;Myung, Eun-Ji;Park, Cheon-Young
    • Journal of the Mineralogical Society of Korea
    • /
    • v.32 no.3
    • /
    • pp.185-200
    • /
    • 2019
  • This study aimed to liberate gold from invisible gold concentrate (Au = 1,840.00 g/t) through microwave nitric acid leaching experiments. For the purpose, this study conducted microwave-nitric acid leaching experiments and examined nitric acid concentration effect, microwave leaching time effect and sample addition effect. The results of the experiments were as follows: Au (gold) contents were not detected in all of the microwave leaching conditions. In the insoluble-residue, weight loss rate tended to decrease as the nitric acid concentration, microwave leaching time and sample addition increased. In an XRD analysis with solid-residue, it was suggested that gypsum and anglesite were formed due to dissolution of calcite and galena by nitric acid solution. When a fire assay was carried out with insoluble-residue, it was discovered that gold contents of the solid-residue were 1.3 (Au = 2,464.70 g/t) and 28.8 (52,952.80 g/t) times more than those of concentrate. But in the gold contents recovered, a severe gold nugget effect appeared. It is expected that the gold nugget effect will decrease if a sampling method of concentrate is improved in the microwave-nitric acid leaching experiments and filtering paper with smaller pore size is used for leaching solution and burned filter paper is used for sampling in lead-fire assay.

A Study on Laboratory Treatment of Metalworking Wastewater Using Ultrafiltration Membrane System and Its Field Application (한외여과막시스템을 이용한 금속가공폐수의 실험실적 처리 및 현장 적용 연구)

  • Bae, Jae Heum;Hwang, In-Gook;Jeon, Sung Duk
    • Korean Chemical Engineering Research
    • /
    • v.43 no.4
    • /
    • pp.487-494
    • /
    • 2005
  • Nowadays a large amount of wastewater containing metal working fluids and cleaning agents is generated during the cleaning process of parts working in various industries of automobile, machine and metal, and electronics etc. In this study, aqueous or semi-aqueous cleaning wastewater contaminated with soluble or nonsoluble oils was treated using ultrafiltration system. And the membrane permeability flux and performance of oil-water separation (or COD removal efficiency) of the ultrafiltration system employing PAN as its membrane material were measured at various operating conditions with change of membrane pore sizes and soil concentrations of wastewater and examined their suitability for wastewater treatment contaminated with soluble or insoluble oil. As a result, in case of wastewater contaminated with soluble oil and aqueous or semi-aqueous cleaning agent, the membrane permeability increased rapidly even though COD removal efficiency was almost constant as 90 or 95% as the membrane pore size increased from 10 kDa to 100 kDa. However, in case of the wastewater contaminated with nonsoluble oil and aqueous or semi-aqueous cleaning agent, as the membrane pore size increased from 10 kDa to 100 kDa and the soil concentration of wastewater increased, the membrane permeability was reduced rapidly while COD removal efficiency was almost constant. These phenomena explain that since the membrane material is hydrophilic PAN material, it blocks nonsoluble oil and reduces membrane permeability. Thus, it can be concluded that the aqueous or semi-aqueous cleaning solution contaminated with soluble oil can be treated by ultrafiltration system with the membrane of PAN material and its pore size of 100 kDa. Based on these basic experimental results, a pilot plant facility of ultrafiltration system with PAN material and 100 kDa pore size was designed, installed and operated in order to treat and recycle alkaline cleaning solution contaminated with deep drawing oil. As a result of its field application, the ultrafiltration system was able to separate aqueous cleaning solution and soluble oil effectively, and recycle them. Further more, it can increase life span of aqueous cleaning solution 12 times compared with the previous process.

Preparation of Polysulfone Composite Ultrafiltration Hollow Fiber Membranes Incorporating Nano-size Fumed Silica with Enhanced Antifouling Properties (나노 크기의 Fumed Silica가 함유된 Polysulfone 한외여과 중공사막 제조 및 내오염성 분석)

  • Kang, Yesol;Lim, Joohwan;Kim, In S.
    • Membrane Journal
    • /
    • v.28 no.6
    • /
    • pp.379-387
    • /
    • 2018
  • This study was conducted to improve the membrane characteristics and performance by increasing hydrophilicity by adding additives to the ultrafiltration polysulfone (PSf) hollow fiber membrane. The mixed matrix membranes (MMMs) were prepared by dispersing 15 nm of fumed silica (FS) in the spinning solution at 0.1, 0.3 and 0.5 wt%. SEM analysis was carried out to confirm the cross-section and surface condition. It was confirmed that mean pore radius of the hollow fiber increased by 4 nm as FS was added. In addition, contact angle measurement was carried out for the hydrophilicity analysis of hollow fiber membranes, and it was confirmed that the hydrophilicity of MMMs were increased by adding of FS. In the case of water permeability, the membrane including FS showed 91~96 LMH and showed 5~11% more increase than PSf membrane. In the antifouling performance test, relative flux reduction ratios of FS mixed hollow fiber membranes were lower than that of PSf membranes, and it was confirmed that increase of hydrophilicity hinders adsorption of hydrophobic BSA on the membrane surface.

Phase Transformation and Microstructural Change of Alumina Membrane (알루미나 여과막의 상전이와 미세구조 변화)

  • Cheong, Hun;Choi, Duck-Kyun;Cheong, Deck-Soo
    • Korean Journal of Materials Research
    • /
    • v.10 no.9
    • /
    • pp.619-623
    • /
    • 2000
  • Alumina membrane was prepared by sol-gel coating method using boehmite powder(${\Upsilon}-AlOOH$). The supported and the unsupported alumina membrane were fabricated to investigate the phase transformation and change of microstructure. It is important to control the homogeneous pore size and distribution in application of filtering process. The ${\theta}-to\;{\alpha}-AL_2O_3$ phase transformation (XRD) and the change of microstructure was investigated using scanning electron microscopy(SEM). XRD patterns showed that the supported membrane had $100^{\circ}C$ higher ${\theta}-to\;{\alpha}-AL_2O_3$ transformation temperature compared to the unsupported membrane. The similar effect was also observed for microstructural change of the membrane.

  • PDF

Development of Electrospun Cellulose Acetate Membranes using Carbon Nanotubes for Filtration of Particulate Matter in the Air (전기방사를 이용한 탄소나노튜브 폴리머 공기정화 멤브레인 개발)

  • Park, Soyeon;Kim, Jaehyuk;Han, Sangil
    • Korean Chemical Engineering Research
    • /
    • v.55 no.1
    • /
    • pp.68-73
    • /
    • 2017
  • The removal of particulate matter ranging from $0.01{\mu}m{\sim}10{\mu}m$ can be performed by using membrane filters composed of fibers. Electrospinning techniques offer the production of very thin fibers with a uniform fiber diameter over conventional techniques including template synthesis, melt-blown, phase separation, etc. Air filtration will be improved with electrospun membranes due to the open pore structures, high porosity, and large surface area of the membranes. In the present study, filtration efficiency increased with pore size decrease and fiber density increase induced by carbon nanotube and the increased CA (cellulose acetate) concentration during electrospinning process.

Modeling of a Dynamic Membrane Filtration Process Using ANN and SVM to Predict the Permeate Flux (ANN 및 SVM을 사용하여 투과 유량을 예측하는 동적 막 여과 공정 모델링)

  • Soufyane Ladeg;Mohamed Moussaoui;Maamar Laidi;Nadji Moulai-Mostefa
    • Membrane Journal
    • /
    • v.33 no.1
    • /
    • pp.34-45
    • /
    • 2023
  • Two computational intelligence techniques namely artificial neural networks (ANN) and support vector machine (SVM) are employed to model the permeate flux based on seven input variables including time, transmembrane pressure, rotating velocity, the pore diameter of the membrane, dynamic viscosity, concentration and density of the feed fluid. The best-fit model was selected through the trial-error method and the two statistical parameters including the coefficient of determination (R2) and the average absolute relative deviation (AARD) between the experimental and predicted data. The obtained results reveal that the optimized ANN model can predict the permeate flux with R2 = 0.999 and AARD% = 2.245 versus the SVM model with R2 = 0.996 and AARD% = 4.09. Thus, the ANN model is found to predict the permeate flux with high accuracy in comparison to the SVM approach.

Treatment of high hexavalent chromium plating wastewater (고농도 6가 크롬 도금 폐수 처리)

  • Kang, Chang Duk;Sim, Sang Jun;Hwang, Suk Hoon
    • Clean Technology
    • /
    • v.7 no.1
    • /
    • pp.75-80
    • /
    • 2001
  • In this study, hexavalent chromium (Cr(VI)) plating wastewater in strong acidic condition was treated by reduction and alkalization. Ferrous sulfate ($FeSO_4$), known to reduce Cr(VI) to Cr(III) rapidly at acidic pH, was used as a reductant of Cr(VI). The optimum reduction condition of Cr(VI) was observed at iron to chromium dose ratio of 3:1 by mole concentration. The precipitation of Cr(III) as $Cr(OH)_3$, was achieved by the pH adjustment in the limestone aeration bed. The precipitates were removed less than the upper limit of chromium for effluent at pH over 5.0. The continuous removal of Cr(VI) was performed using the process consisting of reduction vessel, limestone aeration bed, and sedimentation tank coupled with metal screen membrane. As pH was maintained around 5.0 in the limestone aeration bed, insoluble chromic hydroxide flocs was formed continuously. Most chromic hydroxide flocs were filtered by the metal screen membrane with 1450 mesh size, and the treated water to meet the upper limits of chromium for effluent (Cr Conc. 0.25~0.90 mg/l) was obtained in 30 minutes. Periodic backwashing decreased the fouling on the membrane rapidly.

  • PDF

Effect of $N_2$-back-flushing Time and TMP in Lake Water Treatment Using Multichannel Ceramic Microfiltration Membranes (다채널 세라믹 정밀여과막으로 호소수 처리시 질소 역세척 시간 및 막간 압력차의 영향)

  • Park, Jin-Yong;Park, Bo-Reum
    • Membrane Journal
    • /
    • v.17 no.2
    • /
    • pp.124-133
    • /
    • 2007
  • In this study, we treated lake water by 2 kinds of multichannel ceramic micro filtration membranes. We could investigate effects of $N_2-back-flushing$ time (BT) and transmembrane pressure (TMP), and find optimal operating conditions. The BT were changed in $10{\sim}60$ sec, TMP in $0.6{\sim}2.0$ bar at fixed filtration time (FT) 8 min, flow rate 2.0 L/min and back-flushing pressure 2.0 bar. Also, the optimal conditions were discussed in the viewpoints of resistance of membrane fouling $(R_f)$, dimensionless permeate flux $(J/J_o)$, permeate flux (J) and total permeate volume $(V_T)$. As result, optimal back-flushing conditions for HC04 ($0.4{\mu}m$ pore size) and HC10 membrane $(1.0{\mu}m)$ were BT=10 sec and BT=20 sec, respectively. Then, higher TMP should increase the driving force, and could produce more VT. Average rejection rates of pollutants were higher than 95.4% for turbidity, $12.7{\sim}20.1%\;for\;COD_{Mn},\;0.0{\sim}6.4%\;for\;NH_3-N,\;1.9{\sim}4.6%$ for T-N and $34.9{\sim}88.4%$ for T-P.

Development of Wastewater Treatment and Recycle Technology Using a Tubular Ceramic Ultrafiltration Membrane 1, Effect of Periodic Backflushing (관형 세라믹 한외여과막을 사용한 폐수처리 및 재활용기술개발 : 1, 주기적 역세척 효과)

  • 박진용
    • Membrane Journal
    • /
    • v.9 no.3
    • /
    • pp.178-184
    • /
    • 1999
  • A periodic backflushing was performed to reduce the membrane fouling of ultrafiltration for wastewater, and the effect and the optimum condition were investigated in this study. The alumina¬ceramic tubular membrane with pore size of 0.02${\mu}m$ was used for the wastewater treated by coagulation and sedimentation from two paper plants, of which A plant made toilet paper by recycling milk paper cartons and B plant recycled corrugated cardboards. And the effect of periodic backflushing to membrane fouling and quality of permeate were studied with a constant backflushing time of 3 sec. As results of measuring SS, TDS, and COD of source and permeate, the rejection rate of SS showed the highest value at the backflushing period of 15 see, which was the shortest time in these experiments, in case of waste¬water discharged from A plant. However, the rejection rate of COD had the highest value at the period of 30 sec for wastewater from both A and B plant. Then, the rejection rate of TDS was almost same at 30 and 60 sec for A plant wastewater, and the highest at 60 see for B plant. The effect of periodic back¬flushing to membrane fouling was investigated by change of permeate flux according to operating time. The permeate flux decreased slowly at the operation with backflushing, and was higher compared with that without backflushing in both case of A and B wastewater. But, the optimum period with the highest flux of A wastewater was different from that of B, because SS and COD of A was higher than those of Band TDS of B was higher than that of A.

  • PDF