• Title/Summary/Keyword: 여과지

Search Result 427, Processing Time 0.026 seconds

Evaluation of Filter Media for Use in Alpha Measurement of Radon Progeny (라돈 자핵종의 알파 측정용 여과지 매질의 평가)

  • Seo, Kyung-Won;Knutson Earl O.
    • Journal of Radiation Protection and Research
    • /
    • v.17 no.1
    • /
    • pp.31-41
    • /
    • 1992
  • A study for the evaluation of selected filter media that need further characterization particularily in the context of alpha measurements of radon progeny has been carried out by investigating physical characteristics and using the alpha spectroscopy. Physical characteristics was investigated by electrostatic charging and mechanical strength of filters, and then pressure drop before and after sampling was tested. Alpha spectroscopy was used to analyze the energy spectra from the deposition of radon progeny into filters. The results of the assessment showed that the newer filter types do not have a great advantage over the 'old standard' Millipore type AA. But Metricel DM-800 is recommended for those situations where electrostatic charging is a problem. Also this method will be used more effective for the evaluation of new developing filters in future.

  • PDF

Influence of Filtrate Quality by Variation of Operating Filter Number Based on Inflow (유입유량과 연계한 여과지 가동지수 변동 운영이 여과수 수질에 미치는 영향)

  • Kim, Jin-Keun;Lee, Jung-Tack
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.9
    • /
    • pp.817-824
    • /
    • 2009
  • To prevent turbidity breakthrough in a depth filter caused by hydraulic shock loads, influence of turbidity and particle number in filtrate by variation of operating filter number depending on inflow change was investigated. Inflow quantity at the S water treatment plant (WTP) was varied and ratio of maximum/minimum inflow quantity was 2.2, therefore filtration velocity was also subsequently changed. The S WTP changed operating filter number depending on inflow variation to minimize change of filtration velocity. Particle breakthrough was not severe when operation system was changed, out-of-operation and re-start of filter was repeated depending on inflow quantity. Slight particle breakthrough was noticed when re-start of filter was implemented at the filter that had a cumulative filtration run time of less than 10 h or more than 50 h. This can be attributed to the inadequate ripening and over accumulation of particles on media. Therefore, it is more efficient to choose a re-starting filter basin which has cumulative filtration run time more than 10 h or less than 50 h to reduce particle breakthrough. Filter number variation depending on inflow change was proven to be a method for improvement of unit filter run volume (UFRV).

Evaluation of Grinding Effects on the Extraction of Photosynthetic Pigments for HPLC Analysis (광합성 색소의 HPLC 분석을 위한 여과지 분쇄 효과 평가)

  • Jang, Su Jin;Park, Mi Ok
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.20 no.2
    • /
    • pp.71-77
    • /
    • 2015
  • High-Performance Liquid Chromatography (HPLC) is a widely used method for measuring the concentration of chlorophyll a as an indicator for estimating phytoplankton biomass and primary production and also for identifying carotenoids to determine phytoplankton composition. However, tissue grinding procedure requires a lot of time and experience in the analysis of multiple sample. Accordingly, we measured the concentrations of photosynthetic pigments before and after the grinding, in order to understand the grinding effects on the quantitative analysis of chlorophylls and carotenoids using samples from southwestern East Sea. When tissue grinding procedure was omitted, we found that Chl a concentrations were underestimated up to 45% in average. Also, concentrations of Zeaxanthin, 19'-butanoyloxyfucoxanthin, 19'-hexanoyloxyfucoxanthin, biomarkers of pico and nano-size phytoplankton, were underestimated up to maximum 77~85% without grinding. We found that the smaller the phytoplankton, the bigger underestimation of their biomarker pigments concentration is likely to happen due to the incomplete extraction. Thus, tissue grinding procedure should be included for HPLC analysis in all cases, to prevent the underestimation of not only Chl a but also carotenoids pigments.

Study on Head Loss in Aerated Biofilm Filtration Reactor (폭기생물막(曝氣生物膜) 여과지(濾過池)의 여과저항(濾過抵抗)에 관한 연구(研究))

  • Kang, Yong Tae;Hyun, Kil Soo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.12 no.2
    • /
    • pp.285-291
    • /
    • 1992
  • The purpose of this research, through kinetic analyses and pilot plant experimentation of biofilm filtration reactor, is to study the theoretical equation of head loss in the Biofilm Reactor. The Head loss in the biofilm reactor has occurred due to the biofilm growth and the adhesion to the media surface and stagnation of upflow air bubble, which have caused the pore spaces to become smaller. On a basis of the head loss theory of sand filtration, therefore, the following equation of head loss for the biofilm reactor was proposed from this research results and proved to be possible to apply the equation for practical design of the biofilm filter. $h={\frac{h_o}{L}}{\int}^L_00.58\exp[-4.5){\sigma}_B)][{\frac{1-{\varepsilon}_o+({\sigma}_B)}{1-{\varepsilon}_o}}]^2{[\frac{{\varepsilon}_o}{{\varepsilon}_o-({{\varepsilon}_B)}}]^3dz$ here ${\sigma}_B=0.130+0.001{\theta}$.

  • PDF

Pilot-Scale Evaluation of Granular Filters Using Particle Distribution Analysis (여재구성에 따른 탁질입자 제거특성 및 효율 비교)

  • Ahn, Jong-Ho;Yoon, Jae-Heung
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.5
    • /
    • pp.919-926
    • /
    • 2000
  • The experiment in this study was conducted as a part of an effort to evaluate filter performance with pilot-filters consisting of one mono-media and two dual-media columns. Particle distribution analysis using a particle counter is more sensitive and better than turbidity analysis in observing particle detachments and a breakthrough. In sand media filters having 1.5 m of available head, caution is needed in the head loss of the late stages of filtration, and for dual-media filters, appropriate media configuration and effluent Quality monitoring should be used for preventing the final breakthrough. Also the time of particle breakthrough in the dual media filter can be deferred by increasing bed depth, and it is necessary to use a filtration aid prior to filtration to prevent breakthrough of these intermediate sized particles in high filtration rate.

  • PDF

The Dissolution Efficiency of Gold Concentrate with Microwave-nitric Acid Leaching and the Recovery of Invisible Gold Using the Filter Paper (마이크로웨이브-질산용출에 의한 금 정광의 용해효율과 여과지를 이용한 비-가시성 금 회수)

  • Lee, Jong-Ju;Park, Cheon-Young
    • Economic and Environmental Geology
    • /
    • v.52 no.6
    • /
    • pp.595-604
    • /
    • 2019
  • The purpose of this study was simply to obtain gold through a microwave-nitric acid experiment of invisible gold concentrate with the use of filter paper. For the purpose, this study conducted a microwave-nitric acid leaching experiment and examined nitric acid concentration. As a result of the experiment, this study discovered that Fe, Te and Ag were completely leached in the leaching solution whereas Au was not determined in all of the nitric acid conditions. The leaching solution was filtered with three filter papers and then these filter papers were analyzed with SEM/EDS. As a result of the EDS analysis, Au was detected in all of the surface and cross-section of the 1st, 2nd and 3rd filter papers. As the three filter papers containing solid-residue were analysed in the lead-fire assay, gold particles were found in all of the nitric acid conditions. In the lead-fire assay, maximum gold(452.50g/t) was recovered when nitric acid concentration was 6M and microwave leaching time was 12mins.

좁쌀약주의 여과공정 개선에 관한 연구

  • 강영주;고정삼
    • Proceedings of the Korean Society of Postharvest Science and Technology of Agricultural Products Conference
    • /
    • 2003.10a
    • /
    • pp.176.1-176
    • /
    • 2003
  • 제주지역 양조산업의 산업화 기술 개발의 일환으로 제주지역의 대표적인 전통 좁쌀 약주 제품에 대하여 유통 과정 중에 발생하는 침전 형성을 방지하는 기술을 개발하기 위하여 여과 공정 개선에 관한 연구를 실시하고 개선 방안을 제시하였다. 각종 공극 크기의 유리 막 여과지와 중공사막 카트리지 여과 연구 결과, 이 좁쌀 약주 제품에서 대부분이 침전 형성 가능한 입자들은 1.2$\mu\textrm{m}$여과 매질 공극 크기에 의한 여과에 의하여 제거 되여 보통의 소비에 문제가 되는 침전은 잘 않되는 것으로 조사되었다. 현재 제품 제조 현장에서 사용되고 있는 l$\mu\textrm{m}$ 공극 크기 원통형 정밀 여과기인 경우 이론적으로는 합당하나 여과 매질에 대한 산업 인 공극 크기에 대한 오차 한계인 $\pm$20-30% 때문에 일부제품에서 침전 발생하는 것으로 분석되었다. 또한 4$^{\circ}C$와 실온을 48시간씩 반복하면서 3개월간 저장 중 유리 막 여과지인 경우는 0.7$\mu\textrm{m}$ 공극크기의 여과에서도 세밀한 관찰에 의하여 침전형성이 관찰되었으나 중공사막인 경우에는 0.45$\mu\textrm{m}$에서도 전연 침전형성이 관찰되지 않았다. 따라서 완벽한 침전 형성 방지를 위해서는 최종 여과공정에 중공사막 여과 시스템 도입이 효과적이며, 설계 기준은 0.45$\mu\textrm{m}$ 공극과 내경 1mm정도의 중공사막을 유효 여과 면적 1$m^2$정도를 가지도록 하는 중공사막 여과 시스템인 경우 여과 능력은 약400ι/hr로 계산되었다.

  • PDF

Improvment on the filtration process of foxtail millet Yakju (좁쌀약주의 여과공정 개선에 관한 연구)

  • 강영주;고정삼
    • Food Science and Preservation
    • /
    • v.10 no.4
    • /
    • pp.482-487
    • /
    • 2003
  • The filtration effects of glass membrane filters and hollow fiber membranes with different pore size to prevent the haze of a commercial foxtail millet Yakju were investigated. The most particles(haze precusors) present in the Yakju were removed by using 1.2 $\mu\textrm{m}$ glass membrane filter. In case of using 0.45$\mu\textrm{m}$ hollow fiber membrane system, the permeate flux on the Yakju filtration was calculated to 342.8 lmh. During the 3 month storage at 4$^{\circ}C$ and room temperature for each 48 hrs in turn, alittle fine haze was observed from the Yakju even if it was filtered by using 0.7 $\mu\textrm{m}$ glass membrane filter. Anything of haze was, however, observed from the Yakju filtered by using all of hollow fiber membranes. Therefore, the 0.45$\mu\textrm{m}$ hollow fiber membrane system was effective as a final filtration process of the Yakju.

Development of the Biological Oxidation Filter System for Water Treatment (수처리용 생물산화 여과장치 개발)

  • 염병호;정충혁;문정석;최승일
    • Environmental engineer
    • /
    • s.181
    • /
    • pp.70-75
    • /
    • 2001
  • 본 연구는 '99년 7월에 벤처형 중소기업 기술개발 지원사업으로 신규 계약된 과제로서 상수원수의 전처리 및 하수 2차 침전수의 재처리 공정에 활용될 생물 산화 여과지를 개발하는 것이다. 생물 산화 여과 system은 상수 원수의 전처리, 상수도의 고도정수 처리, 하수 및 폐수처리에 이용될 수 있는 것으로, 특히 물리적 여과기능과 포기 과정을 통한 산화 기능을 포함하는 생물학적 분해 및 자연정화처리환경을 유지하여 수질이 악화된 상수도의 전·후처리나 하.폐수의 3차 처리에 적용하기 위한 것이다. 생물 산화 여과 시스템은 여과지의 하부 장치에 균등한 공기(산소)공급시설을 하여 여과층에 연속적으로 공기를 공급하면서 여과를 함으로서 생물막 여과 및 산화 기능으로 유기물질, 철, 망간 등을 제거하고 공기의 부상력에 의하여 조류, 부유물질, 냄새 등을 동시에 제거하는 System이다. 현재 상수처리 공정으로서의 생물 산화 여과지 개발을 위해 Bench-scale과 semi-pilot plant를 거쳐 Y시 M취수장애 pilot plant를 설치하여 연구를 진행중에 있으며, 또한, G시 G하수처리장에 하수처리 공정에 관한 연구를 위해 pilot plant를 설치하고 하수 3차 처리와 저농도 하·폐수 처리를 중심으로 연구중에 있다. 아래의 연구 결과는 정수처리 공정 연구를 위한 Bench-scale plant실험을 통해 얻은 결과치이며 현재까지 진행된 연구는 주로 정수처리 공정 중심으로 이루어 졌으나 pilot plant에서는 정수 및 하수처리에서의 생물산화여과공정의 연구가 진행중이다. 현재 연구가 진행중이므로 각 인자별 최적운전조건 등은 계속적인 실험과 연구를 통해 찾아지겠으나 현재까지 수행된 연구자료를 기반으로 볼 때 생물산화 여과장치는 탁도, SS, VSS 등의 제거에 탁월한 효능을 보이고 있다. 수처리용 장치로서의 이러한 기본적인 기능 이외에 NPOC, DOC 제거에도 뛰어난 효능을 보이고 있으며 특히 정수처리 공정에서 문제시 되고 있는 동절기 암모니아성 질소제거 또한 큰 가능성을 보여주고 있다. 그 동안 외국기술에 전면 의존해 오던 생물 산화 여과방식의 국내개발은 비용 절감뿐만 아니라 국내 실정에 맞는 기술개발이라는 점에서 향후 그 적용 범위를 넓혀 갈 수 있을 것이다.

  • PDF