• Title/Summary/Keyword: 엘이디 방열

Search Result 7, Processing Time 0.021 seconds

Heat Radiation of Multichip 10W LED Light Using Thermoelectric Module(TEM) (열전소자를 이용한 10W급 멀티칩 LED조명의 방열)

  • Cho, Young-Tae
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.21 no.1
    • /
    • pp.46-50
    • /
    • 2012
  • This paper amis at improving the heat radiation performance of thermoelectric module (TEM) for a commercialization of high-powered LED light with using a multichip LED module. In addition, a 10W multichip LED light was prepared for the heat performance on radiating of which LED light was made for a use of testing by the driving of the thermoelectric module. So, it was found that about 30% in the effect of temperature reduction was confirmed if compared with the radiation heat by heat sink only.

고휘도 엘이디 섬광기를 적용한 해상용 등명기의 방열 특성에 관한 연구

  • Im, Min-Seok;Jeong, Tae-Gwon
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2013.06a
    • /
    • pp.31-33
    • /
    • 2013
  • 종래의 전구식 등명기의 경우 중량이 많이 나갈 뿐만 아니라 전구의 교체시기가 짧고 전력소모가 심하다는 문제가 있었다. 또한 5mm 포탄형 저휘도 LED램프의 경우에는 수명이 길고 저전력이라는 장점이 있으나, 근래에는 해상의 배후광이 높아져 개당 소비전력이 1W(와트) 이상인 고휘도 파워 LED를 광원으로서 채택하는 등명기가 등장하고 있는 실정이다. 그런데, 이러한 고휘도 파워 LED의 경우 종래의 포탄형 LED에 비하여 광도는 매우 높으나, 소비전력이 상대적으로 매우 높으며, 그에 따라 발열이 심하다는 문제가 있다. 따라서, 고휘도 파워 LED를 채용하여 등명기의 광도를 높이는 경우에는 반드시 방열 문제를 고려해야 한다. 그렇지 않으면, 고휘도 파워 LED의 발열로 인하여 제품이 안정적으로 구동할 수 없으며, 결국에는 관련 부품의 고장이나 파손으로 이어지기 때문이다. 본 연구는 종래의 전구식 램프나 저전력 포탄형 LED램프를 대체하여 고휘도 파워 LED램프를 광원으로 적용함에 있어, 등명기의 중량을 증가시키지 않는 구조로서 보다 효과가 우수한 방열기술을 개발하기 위한 것이다.

  • PDF

Heat Radiation of LED Light using eu Plating Engineering Plastic Heat Sink (동도금 EP방열판에 의한 소형LED조명등 방열)

  • Cho, Young-Tae
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.20 no.1
    • /
    • pp.81-85
    • /
    • 2011
  • Recently, the electronic parts are to be thinner plate, smaller size, light weight material and CPU, HDD and DRAM in all the parts have been produced on the basis of the high speed and greater capacity. Also, conventional goods have replaced a LED (Light-Emitting Diode) in lighting products so; such industry devices need to have cooling. To maximize all the performance on the heat-radiated products, the area of heat-radiated parts is required to be cooled for keeping the life time extension and performance of product up. Existing cooling systems are using radiant heat plate of aluminum, brass by extrusion molding, heat pipe or hydro-cooling system for cooling. There is a limitation for bringing the light weight of product, cost reduction, molding of the cooling system. So it is proposed that an alternative way was made for bringing to the cooling system. EP (Engineering Plastic) of low-cost ABS (Acrylonitrile butadiene styrene Resin) and PC (Polycarbonate) was coated with brass and the coating made the radiated heat go up. The performance of radiant heat plate is the similar to the existing part. We have studied experimentally on the radiated heat plate for the light-weight, molding improvement and low-cost. From now on, we are going to develop the way to replace the exiting plate with exterior surface of product as a cooling system.

Design Optimization of an Extruded-type Cooling Structure for Reducing the Weight of LED Streetlights (LED 가로등용 압출형 방열 구조물 경량화를 위한 최적 설계)

  • Park, Seung-Jae;Lee, Tae-Hee;Lee, Kwan-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.10
    • /
    • pp.394-401
    • /
    • 2016
  • The configuration of an extruded-type cooling structure was optimized for the light-emitting diode (LED) streetlights that have recently replaced convectional metal halide streetlights for energy saving. Natural convection and radiative heat transfer over the cooling structure were simulated using a numerical model with experimental verification. An improved cooling structure type was suggested to overcome the previous performance degeneration, as confirmed by analyzing the thermal flow around the existing cooling structure. A parameter study of the cooling structure geometries was also conducted and, based on the numerical results, the configuration was optimized to reduce the weight of the cooling structure. Consequently, the mass of the cooling structure was reduced by 60%, while the thermal performance was improved by 10%.

Optical Design of a Multilayer LED Array Light Source and Illumination Optics for a Large-Screen LC Projection Display System (대화면 액정 화상 투영기용 다층 배열 엘이디 광원 및 조명광학계 설계)

  • Kim, Hyun Hee;Han, Dong Jin;Kim, Jin Seung
    • Korean Journal of Optics and Photonics
    • /
    • v.26 no.4
    • /
    • pp.226-232
    • /
    • 2015
  • A double-layer LED array together with an illumination optical system is proposed as a possible light source for LC projection display systems for large screens, up to $8m{\times}6m$ (400 inches diagonal). The heat dissipation problem of the LED array is solved by arranging the LEDs in double layers, and thermal analysis shows its effectiveness. The light from the LEDs in the back layer can be transmitted through the front layer without significant loss by arranging the LEDs in non-overlapping positions in the two layers and inserting suitable microlenses between the two layers and holes in the first layer. Together with the double-layer LEDs, an illumination optical system is designed to illuminate liquid crystal panels with good uniformity and appropriate matching with the projection optics.

Performance Evaluation of Heat Radiant for 50W LED by the CNT Thermal Interface Material (CNT 열전달 물질에 의한 50W LED의 방열 성능평가)

  • Cho, Young-Tae;Lee, Choong-Ho
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.13 no.6
    • /
    • pp.23-29
    • /
    • 2014
  • In this study, cooling and heat-transfer tests are performed to compare and evaluate the thermal conductivity in a prepared CNT TIM (thermal interface material). A polymerized CNT heat-transfer resin and commercial thermal grease (Shinetsu G-747) were applied for a comparison test in both cases. Cooling experiments with an aluminum foil specimen were performed in order to measure the temperature distribution using an infrared camera, and in heat radiation experiments, performance testing of the thermal conductivity was conducted using high-power LEDs. Carbon resin with the polymerization of graphite and carbon black, and CNT-polymerized CNT resin with graphite and carbon black were tested and compared with using G-747. It was found that the cooling performance and the heat transfer ability in both the carbon resin and the CNT-polymerized CNT resin were greater than those of G-747 because the temperature by 5. $0^{\circ}C$ in both cases appeared lower than that of the G-747.

Heat Sink of LED Lights Using Engineering Plastics (엔지니어링 플라스틱의 LED조명 방열판 적용)

  • Cho, Young-Tae
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.12 no.4
    • /
    • pp.61-68
    • /
    • 2013
  • As an advance study for the development of a heat sink for special purpose high power illumination, an investigation was made to find feasibility for the application of copper plated EP to a heat sink of small LED light of less than 10W installed in commercial product. In this study, the plated heat sink with EP copper was fabricated for the conventional LED light. It was used actually for finding heat radiation property and effectiveness of the heat sink accompanied with measurement of luminous intensity. The heat is radiated by transfer and dissipation only through the copper plated surface due to extremely low heat conductivity of EP in case of EP heat sink; however the total area of the plate plays the function of heat transfer as well as heat radiation in case of the aluminum heat sink. It seems that the volume difference of heat radiating material is so big that the temperature $P_1$ is 9.0~12.3% higher in 3W and 42.7~54.0% higher in case of 6W volume difference of heat radiating material is so big that the temperature $P_1$ is 9.0~12.3% higher in 3W and 42.7~54.0% higher in case of 6W even though heat transfer rate of copper is approximately 1.9 times higher than that of aluminum. It was thought that this is useful to utilize for heat sink for low power LED light with the low heating rate. Also, the illumination could be greatly influenced by the surrounding temperature of the place where it is installed. Therefore, it seems that the illumination installation environment must be taken into consideration when selecting illumination. Further study was expected on order to aims at development of an exterior surface itself made into heat radiation plate by application of this technology in future.