• Title/Summary/Keyword: 에코

Search Result 1,085, Processing Time 0.022 seconds

A Survey of Floating Silt-Clay Thickness using Dual Frequency Echo Sounder (이중 주파수 에코사운더를 이용한 부니층 두께 조사)

  • Ha, Hee-Sang;Park, Hyeong-Keun;Kim, Yeon-Jun;Yang, In-Tae
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.10 no.4
    • /
    • pp.14-21
    • /
    • 2007
  • In general bathymetric surveying is the method which gets depth. The water depth on chart is generally measured by a 200Khz frequency echo-sounder. In this study the thickness of the floating silt-clay was measured by a duel frequency sounder using 33Khz and 200Khz. This study shows the method of measuring the volume of the floating silt-clay in dredged basins dredged basin. After this surveying RI test was performed for verifying the existence of the silt-clay.

  • PDF

Transrectal ultrasonographic findings of diffuse hypoechogenic parenchyma in canine prostate gland (개의 전립선에 있어서 경직장 초음파 검사법을 이용한 미만성 저에코영역의 성상)

  • Eom, Ki-dong;Sung, Jai-ki
    • Korean Journal of Veterinary Research
    • /
    • v.37 no.3
    • /
    • pp.687-692
    • /
    • 1997
  • 개의 전립선에서 경직장 초음파상에 나타나는 미만성 저에코영역의 성상과 경직장 초음파 검사법의 유용성을 알아보기 위해 히스토그람 분석방법과 color doppler 초음파를 이용하여 전립선 맛사지에 따른 전립선 실질의 에코변화를 비교하였다. 전립선 맛사지 후 히스토그람상의 휘도치는 전립선 요도부 기준 상부측 실질내에서 유의성(p<0.01) 있게 고에코로 변화되어 나타났으며, 전립선내에 분포하는 혈관은 저에코영역에서 보다 고에코영역에서 발견되었다. 이상의 결과로 보아 경직장 초음파 검사법은 전립선의 미세한 변화에 대해 보다 상세한 실질내의 정보를 제공할 수 있는 효과적인 검사 방법이며, 맛사지에 따른 휘도치의 변화는 전립선의 물리적 자극에 대한 전립선액의 분비에 따른 결과로 사료되고, 저에코영역은 혈관보다는 전립선액이 점유하고 있는 것으로 생각된다.

  • PDF

A Study on the ESS Construction and Proper Operation Considering the Load Characteristics of the Distribution Logistics Facilities (유통물류시설 부하특성을 고려한 ESS 구축 및 적정 운영 방안에 관한 연구)

  • Heo, Donghyeok;Choi, Okhwan;Kwon, Dongmyeong
    • Journal of Energy Engineering
    • /
    • v.28 no.2
    • /
    • pp.36-46
    • /
    • 2019
  • Through the application of ESS-based fusion products to the demonstration site of the urban distribution logistics facilities for designing the peak control and the substitution before the emergency generator operation by product application and the effective application method by the product application and the data analysis by overcoming the spatial limitation of ESS installation and distribution, And the expansion of distribution and logistics facilities.

Carbon measurement and 'Eco etiquette Carbon diary' application development for low-carbon living (저탄소 생활을 위한 탄소 발자국 측정 및 '에코에티켓 탄소일기장' 어플리케이션 개발)

  • Lee, ahyeon;Koo, seunghoe;Han, wonhee;Kim, minyoung
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2022.11a
    • /
    • pp.940-942
    • /
    • 2022
  • 2050탄소 중립 사회 전환을 위한 저탄소 발전전략으로 정부는 '2050 탄소중립'을 선언하고 '2050 탄소중립 시나리오' 수립을 추진하고 있다. 본 논문에서는 개인이 저(低) 탄소 생활을 위한 '에코라이프(녹색습관)' 탄소량 측정과 일상생활에서 자주 먹는 음식들의 탄소량을 측정함으로써 하루 얼마나 많은 양의 탄소 소비의 비교를 통해 경제와 지구를 살리는 '저(低) 탄소 에코라이프'를 제시하고자 한다.

The Effect of Number of Echoes and Random Noise on T2 Relaxography : Development of 8-Echo CPMG (에코의 개수와 임의 잡음이 T2 이완영상의 구성에 미치는 영향연구 : 8에코 CPMG영상화 펄스열의 개발)

  • 정은기
    • Investigative Magnetic Resonance Imaging
    • /
    • v.2 no.1
    • /
    • pp.67-72
    • /
    • 1998
  • The mapping of the spin-spin relaxation time T2 in pixel-by-pixel was suggested as a quantitative diagnostic tool in medicine. although the CPMG pulse sequence has been known to be the best pulse sequence for T2 measurement in physics NMR, the supplied pulse sequence by the manufacture of MRI system was able to obtain the maximum of 4 CPMG images. Eight or more images with different echo time TEs are required to construct a reliable T2 map, so that two or more acquisitions were required, which easily took more than 10 minutes. 4-echo CPMG imaging pulse sequence was modified to generate the maximum of 8 MR images with evenly spaced echo time TEs. In human MR imaging, since patients tend to move at least several pixels between the different acquisitions, 8-echo CPMG imaging sequence reduces the acquisition time and may remove any mis-regitration of each pixels signal for the fitting of T2. The resultant T2 maps using the theoretically simulated images and using the MR images of the human brain suggested that 8 echo CPMG sequence with short echo spacing such as 17-20 msec can give the reliable T2 map.

  • PDF

Effectiveness of a fast spin echo technique using the signal void in acquisition of black blood images (흑혈류영상 획득 시 신호소실을 활용한 고속스핀에코기법의 유용성)

  • Choi, Kwan-Woo;Kim, Yoon-Shin;Son, Soon-Yong;Lee, Hee-Ju;Min, Jung-Whan;Lee, Jong-Seok;Yoo, Beong-Gyu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.9
    • /
    • pp.4313-4319
    • /
    • 2013
  • The purpose of our study is to shorten the scanning time and minimize the inconveniences of the patients in acquisition of the black blood images using the signal void effect in the fast spin echo technique while keeping the diagnostic value of the test. Thirty-two consecutive patients who underwent black blood MR imaging were examed with additional double inversion recovery (DIR) sequence and the conventional fast spin echo (FSE) sequence. Signal to Noise Ratio (SNR) and Contrast to Noise Ratio (CNR) of the internal carotid arteries' lumen were compared in T1 and T2 weighted images to determine whether there are differences between the two techniques for depiction of the signal void effect inside the vessel wall. The FSE images showed lower SNR values than the DIR images in both of the T1 and T2 weighted images (11.49% and 13.66% respectively). While the CNR values were higher in the FSE images than in the DIR images in both of the T1 and T2 weighted images (8.69% and 7.55% respectively).There was no significant difference between the two techniques for either of the SNR or CNR (p>0.05, p>0.05 respectively). The DIR and the FSE images demonstrated almost identical imaging patterns. Therefore, it is anticipated that the use of FSE technique in acquisition of the black blood imaging could reduce the inconveniences of the patients during the scanning and minimize exam time while keeping the diagnostic value of the test.

Pulsatility Index of Blood Echogenicity of the Human Radial and Common Carotid Arteries: Relation with Age and Stroke (인체 요골동맥과 경동맥의 혈액에코박동지수: 나이 및 뇌졸중과의 관계)

  • Bok, Tae-Hoon;Kong, Qi;Nam, Kweon-Ho;Choi, Jay Chol;Paeng, Dong-Guk
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.5
    • /
    • pp.494-501
    • /
    • 2012
  • In the present paper, the ultrasound blood images were measured at both the human radial artery(RA) and common carotid artery(CCA), depending on the age, and the pulsatility index of blood echogenicity(PIBE) was analyzed. In addition, the ultrasound blood images were measured at both RA and CCA of both the stroke patients and the control group, and PIBE was compared. PIBE of RA for the young group was similar with that for the old group ($0.13{\pm}0.11$ and $0.16{\pm}0.03$). PIBE of CCA for the young group, however, was larger than that for the old group ($0.70{\pm}0.21$ and $0.32{\pm}0.01$), and was more variable depending on the subject. Similarly, the fibrinogen concentrations of the patients ($336{\pm}61$ and $340{\pm}126mg/dl$) were more than that of the control group ($264{\pm}38$ and $257{\pm}43mg/dl$), for both RA and CCA. The results indicate the possibility of the ultrasonic test on the correlation between erythrocyte aggregation and stroke, and it is expected that the in-vivo EA measurement would be clinically useful.