• Title/Summary/Keyword: 에너지 정의

Search Result 2,864, Processing Time 0.033 seconds

Quasi-Static Tests for Seismic Performance of Circular RC Bridge Piers (단일주 원형 철근콘크리트 교각의 내진거동에 관한 준정적 실험)

  • 정영수;이강균;한기훈;박종협
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.3 no.2
    • /
    • pp.55-66
    • /
    • 1999
  • Eight RC bridge plers have been made on a 1/3.4 scale model and have been tested in a quasi-static cyclic load so as to investigate their seismic performance. The ultimate objective of this experimental study is to investigate the hysteretic behavior of reinforced concrete plers, which have been widely used for urban transportation facilities in Korea. Improtant test parameters are hoop ratio, axial load, load pattern, and etc. And noninear behaviors of test columns have been evaluated through their yield and ultimate strength, energy dissipation, ductility and load-deflection characteristics under quasi-static cyclic loads. From the quasi-static tests on 8 bridge piers, it is concluded that energy dissipation, ultimate strength and curvature for a given displacement factor ${\mu}={\Delta}/{\Delta}_y$ are higher for the seismically designed columns than for the nonseismically designed columns.

  • PDF

Kinetic Study on the Polycondensation Reaction of Bis-hydroxyethyl Naphthalate (Bis-hydroxyethyl Naphthalate의 축중합 반응에 관한 속도론적 연구)

  • 이성진;정성일
    • Polymer(Korea)
    • /
    • v.26 no.4
    • /
    • pp.422-430
    • /
    • 2002
  • The kinetics of polycondensation of bishydroxyethyl naphthalate has been studied in the range of 241 -$260^{\circ}C$ using antimony trioxide catalyst. The reaction was performed in a batch reactor and the concentration of reaction mixture was measured with HPLC. The activation energy values of forward and reverse reaction determined from molecular species model were found to be 19.7 and 31.4 kcal/mole, respectively, and the equilibrium constants were in the range of 1.4-2.0, which were larger than that of polycondensation of PET and varied to some degree with temperature. It was confirmed by applying the Flory's distribution function that the reaction rate of the hyroxyethyl group does not depend on the molecular size. By applying functional group model, we observed that there was few difference between the activation energy of the forward reaction and that of reverse reaction, therefore the equilibrium constant has almost constant value of 1.4. The rate constants obtained from functional group model was about 3-4 times larger than that from molecular species model, which showed that both model explains the reaction system well. Although the molecular species model should predict the concentration of as many as ten molecules, it fits for the experimental results well.

Effects of Biomass Additives on Yield of Coal Liquefaction (석탄액화시 바이오매스계 첨가제의 효과)

  • Kim, J.W.;Sim, K.S.;Lee, S.H.;Park, K.B.;Lalvani, S.B.
    • Solar Energy
    • /
    • v.18 no.3
    • /
    • pp.161-167
    • /
    • 1998
  • The effects of some additives(black liquor, wood and lignin) on the conversion of coal and product were investigated in the lab-scale, high pressure reacting system around $375^{\circ}C$. The addition of lignin to coal during liquefaction significantly increased the depolymerization of coal and enhanced the quality of the liquid products. Coprocessing of wood and coal at $400^{\circ}C$ increased yield of liquid product about 8%, but higher temperature above $400^{\circ}C$ reduced liquid product due to increase of gas products. The addition of black liquor resulted in an enhancement in coal conversion yields, however, the observed increase is lower than that obtained in the presence of NaOH because lignin present in black liquor is not very effective due to the $OH^-$ presence.

  • PDF

The Study on the Characteristic of Mono Crystalline Silicon Solar Cell with Change of $O_2$ Injection during Drive-in Process and PSG Removal (단결정 실리콘 태양전지 도핑 확산 공정에서 주입되는 $O_2$ 가스와 PSG 유무에 따른 특성 변화)

  • Choi, Sung-Jin;Song, Hee-Eun;Yu, Gwon-Jong;Lee, Hi-Deok
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.04a
    • /
    • pp.105-110
    • /
    • 2011
  • The doping procedure in crystalline silicon solar cell fabrication usually contains oxygen injection during drive-in process and removal of phosphorous silicate glass(PSG). In this paper, we studied the effect of oxygen injection and PSG on conversion efficiency of solar cell. The mono crystalline silicon wafers with $156{\times}156mm^2$, $200{\mu}m$, $0.5-3.0{\Omega}{\cdot}cm$ and p-type were used. After etching $7{\mu}m$ of the surface to form the pyramidal structure, the P(phosphorous) was injected into silicon wafer using diffusion furnace to make the emitter layer. After then, the silicon nitride was deposited by the PECVD with 80 nm thickness and 2.1 refractive index. The silver and aluminium electrodes for front and back sheet, respectively, were formed by screen-printing method, followed by firing in 400-425-450-550-$880^{\circ}C$ five-zone temperature conditions to make the ohmic contact. Solar cells with four different types were fabricated with/without oxygen injection and PSG removal. Solar cell that injected oxygen during the drive-in process and removed PSG after doping process showed the 17.9 % conversion efficiency which is best in this study. This solar cells showed $35.5mA/cm^2$ of the current density, 632 mV of the open circuit voltage and 79.5 % of the fill factor.

  • PDF

A Performance Measurement and Evaluation of a 400RT Vertical type Geothermal System installed in a Complex Building Before Occupancy (복합용도 건물에 적용된 400RT급 수직형 지열시스템의 입주전 성능평가)

  • Hwang, Kwang-Il;Shin, Dong-Keol;Kim, Joong-Hun;Shin, Seung-Ho;Jung, Myoung-Kwan
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.3
    • /
    • pp.7-14
    • /
    • 2008
  • 400RT geothermal system which is the biggest capacity among on-operations at present in Korea is measured and evaluated on 23rd${\sim}$26th Jan. 2008 during those days building is not allowed owners and/or tenants to move in. The geothermal system is consist with vertical-typed 112 geothermal heat exchangers which are installed circle-like 1 row with 4m interval, and has 16 units of 25USRT geothermal-source heat pump(GSHP)s. And each 5 units of circulation pump are running for geothermal heat exchangers and hot water supplies. The followings are the results. The temperatures at G.L. -70m of 2 boreholes are varied quite similarly. The average temperature difference between inlet and outlet of geothermal pipes is $4.1^{\circ}C$, and that of hot water supply is $3.2^{\circ}C$, of Zone 3's each 4 GSHPs when being operated. Despite temperature fluctuations by heating loads, the average temperature difference between main pipes of inlet and outlet of geothermal heat exchangers is measured as $4.1^{\circ}C$. This study propose "Geothermal System COP" which includes not only consumed electric power by compressor but also circulation pumps and auxiliary utilities. By comparing the geothermal system COP with GSHP's performance specification, it is clear that the performances of GHSPs of this site are satisfied with the specification.

An Experimental Study on Heat Transfer Augmentation by Square Rod in Impinging Air Jet System(Effect of Rod Width) (사각로드를 이용한 충돌분류계의 열전달증진에 관한 연구(로드폭의 영향))

  • Kum, Seong-Min;Lee, Yong-Hwa;Seo, Jeong-Yun
    • Solar Energy
    • /
    • v.15 no.3
    • /
    • pp.127-140
    • /
    • 1995
  • This experimental study was carried out to examine the heat transfer characteristics of a 2-dimensional impinging air jet on a flat plate with a set of square rods. The objectives of the study were to investigate the flow and heat transfer characteristics caused by the square rods. Experiment was carried out first without using the rods to establish the baseline heat transfer performance. Then, rods of different widths and clearances were installed to cause the turbulence on the fluid flow. When rods are installed in front of the plate, the acceleration of the flow and the turbulence generation due to the rods and reattachment of the flow seem to contribute to the observed heat transfer augmentation and the heat transfer augmentation increases as the clearance decreases. With wider individual rod the heat transfer coefficient is higher, which is due to the increased acceleration and development of the eddies just before the rods.

  • PDF

An Evaluation Study of Domestic Direct(Beam) Nomal Solar Radiation Data (국내 직달일사량 자원의 평가 연구)

  • Jo, Dok-Ki;Lee, Tae-Kyu;Kim, Eun-Ill;Chun, Il-Soo;Lee, Soon-Myoung;Cho, Suh-Hyun;Auh, Chung-Moo
    • Solar Energy
    • /
    • v.13 no.1
    • /
    • pp.59-66
    • /
    • 1993
  • Since the direct(beam) normal solar radiation is a main factor for designing any focusing solar system, it is necessary to evaluate its characteristics all over the country. We have begun collecting direct normal solar radiation data since December 1990 at 16 different locations and considerable effort has been made for constructing a standard value from measured data at each station. KIER's new data will be extensively used by concentrating system users or designers as well as by research institutes. From the results, we can conclude that 1) $4,400kcal/m^2$. day of the direct(beam) normal solar radiation was evaluated for clear day. 2) Direct normal solar radiation of spring and summer were 6% and 14%, higher than the yearly average value, respectively, and for fall and winter their values were 5% and 15% than the yearly average value, respectively.

  • PDF

Characteristics of Mono Crystalline Silicon Solar Cell for Rear Electrode with Aluminum and Aluminum-Boron (Aluminum 및 Aluminum-Boron후면 전극에 따른 단결정 실리콘 태양전지 특성)

  • Hong, Ji-Hwa;Baek, Tae-Hyeon;Kim, Jin-Kuk;Choi, Sung-Jin;Kim, Nam-Soo;Kang, Gi-Hwan;Yu, Gwon-Jong;Song, Hee-Eun
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.34-39
    • /
    • 2011
  • Screen printing method is a common way to fabricate the crystalline silicon solar cell with low-cost and high-efficiency. The screen printing metallization use silver paste and aluminum paste for front and rear contact, respectively. Especially the rear contact between aluminum and silicon is important to form the back surface filed (Al-BSF) after firing process. BSF plays an important role to reduces the surface recombination due to $p^+$ doping of back surface. However, Al electrode on back surface leads to bow occurring by differences in coefficient of thermal expansion of the aluminum and silicon. In this paper, we studied the properties of mono crystalline silicon solar cell for rear electrode with aluminum and aluminum-boron in order to characterize bow and BSF of each paste. The 156*156 $m^2$ p-type silicon wafers with $200{\mu}m$ thickness and 0.5-3 ${\Omega}\;cm$ resistivity were used after texturing, diffusion, and antireflection coating. The characteristics of solar cells was obtained by measuring vernier callipers, scanning electron microscope and light current-voltage. Solar cells with aluminum paste on the back surface were achieved with $V_{OC}$ = 0.618V, JSC = 35.49$mA/cm^2$, FF(Fill factor) = 78%, Efficiency = 17.13%.

  • PDF

Optimization of Drive-in Temperature at Doping Process for Mono Crystalline Silicon Solar Cell (단결정 실리콘 태양전지의 도핑 최적화를 위한 확산 온도에 대한 연구)

  • Cho, Sung-Jin;Song, Hee-Eun;Yoo, Kwon-Jong;Yoo, Jin-Soo;Han, Kyu-Min;Kwon, Jun-Young;Lee, Hi-Deok
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.1
    • /
    • pp.37-43
    • /
    • 2011
  • In this paper, the optimized doping condition of crystalline silicon solar cells with $156{\times}156\;mm^2$ area was studied. To optimize the drive-in temperature in the doping process, the other conditions except variable drive-in temperature were fixed. These conditions were obtained in previous studies. After etching$7\;{\mu}m$ of the surface to form the pyramidal structure, the silicon nitride deposited by the PECVD had 75~80nm thickness and 2 to 2.1 for a refractive index. The silver and aluminium electrodes for front and back sheet, respectively, were formed by screen-printing method, followed by firing in 400-425-450-550-$850^{\circ}C$ five-zone temperature conditions to make the ohmic contact. Drive-in temperature was changed in range of $830^{\circ}C$ to $890^{\circ}C$to obtain the sheet resistance $30{\sim}70\;{\Omega}/{\box}$ with $10\;\Omega}/{\box}$ intervals. Solar cell made in $890^{\circ}C$ as the drive-in temperature revealed 17.1% conversion efficiency which is best in this study. This solar cells showed $34.4\;mA/cm^2$ of the current density, 627 mV of the open circuit voltage and 79.3% of the fill factor.

Discussion on the Criterion for the Determination of On-Water Oil Removal Resource Requirement in Korea (우리나라 기름오염 방제능력 확보기준의 타당성)

  • Kang Seong-Gil;Sung Hong-Gun;Lee Moonjin;Choi Hyuek-Jin;Yu Jeong-Seok;Kang Chang-Gu
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.5 no.4
    • /
    • pp.3-18
    • /
    • 2002
  • The present study was carried out to discuss the suitability of the criterion for the determination of the on-water oil removal resource requirement in Korea by comparison with the US criterion. According to the present criterion in Korea, the on-water response operation against the worst case discharge assuming the oil spillage of 60,000 ton from the accident of DWT 300,000 tanker requires the oil recovery capacity of 19,425 kl/hr (on-water recovery volume 20,000 ton). Under the US criterion, the recovery capacity of 16,667 kl/hr is required to respond to oil spill accident of the worst case discharge from the DWT 300,000 tanker. The result shows that resource requirement from the Korean criterion is 16% higher than US criterion, indicating that thc Korean criterion is reasonable.

  • PDF