• Title/Summary/Keyword: 에너지 소산효율

Search Result 47, Processing Time 0.032 seconds

Modeling and Theoretical Analysis of Thermodynamic Characteristic of Nano Vibration Absorber (나노 진동 흡수기의 모델링 및 열역학적 특성 해석에 대한 이론적 연구)

  • 문병영;정성원
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.7 no.6
    • /
    • pp.93-99
    • /
    • 2003
  • In this study, new shock absorbing system is proposed by using nano-technology based on the theoretical analysis. The new shock absorbing system is complementary to the hydraulic damper, having a cylinder-piston-orifice construction. Particularly for new shock absorbing system, the hydraulic oil is replaced by a colloidal suspension, which is composed of a porous matrix and a lyophobic fluid. The matrix of the suspension is consisted of porous micro-grains with a special architecture: they present nano-pores serially connected to micro-cavities. Until now, only experimentally qualitative studies of new shock absorbing system have been performed, but the mechanism of energy dissipation has not been clarified. This paper presents a modeling and theoretical analysis of the new shock absorbing system thermodynamics, nono-flows and energy dissipation. Compared with hydraulic system, the new shock absorbing system behaves more efficiently, which absorb a large amount of mechanical energy, without heating. The theoretical computations agree reasonably well with the experimental results. As a result. the proposed new shock absorbing system was proved to be an effective one, which can replace with the conventional one.

Design of Energy Dissipaters for Improving on Efficiency in Settling Basin (침사지 효율성 제고를 위한 에너지 소산 구조물의 설계)

  • Jung, Sang-Hwa;Kim, Chang-Wan;Lee, Min-Ho
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2006.05a
    • /
    • pp.1323-1327
    • /
    • 2006
  • 일반적으로 화력발전소는 원활한 원료 및 냉각수의 공급과 환경적인 요인으로 인해 내륙보다는 해안에 위치하고 있다. 발전소의 안정성을 확보하기 위해서는 고열의 발전기를 냉각하는 냉각설비들이 반드시 필요하며 이를 위해 취수로를 통한 냉각수의 원활한 공급이 이루어져야 한다. 이러한 냉각수 공급은 대용량 펌프에 의해 이루어지며, 취수로 구조물의 형상 및 냉각수의 흐름조건에 따라 성능과 수명이 좌우된다. 특히 해안에 위치하는 지리적 여건상 직접취수가 많으며 이러한 경우 유사가 취수로에 유입되어 펌프 흡입 시 균열과 임펠러 마모 등을 유발시켜 펌프의 안전에 악영향을 미치게 된다. 따라서 취수로에 유사의 퇴적을 유도하는 침사지를 설계하게 되며 Hydraulic Institute Standards(1998)에서는 허용설계유속을 0.2 m/s 이하로 정하고 있다. B 발전소는 직경 3 m의 대형 취수관로 3개를 통해 매우 빠른 유속으로 취수로에 유입되는 냉각수 계통 구조물을 가지고 있어 침사지 내 유속이 허용기준을 초과하였다. 본 연구에서는 침사지내 유속을 만족시키기 위해 다양한 에너지 소산 구조물 설계방안을 제시하였다. 각 설계방안에 따른 흐름 특성 및 유속 분포를 파악하고 common bay 내에서의 난류특성을 분석하여 비교.검토하였다. 수리모형실험 결과를 통해 각각의 설계방안에 따른 침사지의 효율을 평가하였으며 최적의 에너지 소산 구조물에 대한 설계방안을 제안하였다.

  • PDF

Equivalent Damping Ratio of a SDOF Structure Combined with Coulomb and Viscous Damping (점성 및 마찰감쇠가 있는 단자유도 구조물의 등가감쇠비)

  • Seong, Ji-Young-Suck;Min, Kyung-Won
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2010.04a
    • /
    • pp.449-453
    • /
    • 2010
  • 본 논문에서는 점성 및 감쇠가 있는 단자유도 구조물의 등가감쇠비를 효율적으로 구하는 방법을 제시하였다. 건물에 설치된 마찰감쇠기는 외력의 크기에 따라 정지와 운동의 상태를 반복하여 외부 입력에너지를 소산시키기 때문에 외력과 응답관계가 비선형이다. 마찰감쇠기가 설치된 단자유도 건물은 마찰감쇠기외에 점성감쇠가 동시에 존재하므로 해석적인 정해를 구하기가 어렵다. 등가감쇠비를 산정하기 위해서 첫째, 점성과 마찰감쇠가 있는 단자유도계 건물의 자유진동 정해를 통하여 변위응답과 가속도 응답특성을 분석하였다. 둘째, 자유진동의 경우 응답이 멈출 때까지 소산에너지식을 이용하여 등가점성감쇠비를 구하였다. 셋째, 조화가진 일 때는 수치해석을 통하여 마찰력비 $F_r$에 따른 응답 특성을 알아보았다. 넷째, 조화가진의 경우 에너지 균형식을 바탕으로 등가점성감쇠비를 유도하였다. 등가점성감쇠비는 변위응답비의 영향을 받으므로 응답을 알아야만 구할 수 있다. 건물 응답의 진동수 특성은 협소영역(narrow band)이므로 고유진동수에 의해 지배된다고 가정하여 등가점성감쇠비를 구하였다. 마지막으로, 유도한 자유진동과 조화가진의 등 가점성감쇠비를 이용한 등가선형운동방정식의 해를 비선형 수치해석 한 결과와 비교하여 검증하였다.

  • PDF

Nonlinear Analysis and Design of Rectangular Damper (직사각형 댐퍼의 비선형 해석 및 설계)

  • Eom, Seung Hyeon;Kim, Won Ki
    • Journal of Korean Society of Steel Construction
    • /
    • v.15 no.4 s.65
    • /
    • pp.447-456
    • /
    • 2003
  • In this study, the proper shape of dampers was determined when the outside frame formed a rectangle. The proper shape of dampers is rectangular, having the same ratio as the outside frame. The design was based on the impact energy dissipated by the seismic performance of the mainly rectangular dampers. This study sought to compare both strength and energy dissipation between nonlinear analysis data and experimental data through load-displacement curves. The use of the ANSYS FEM software was suggested to analyze the nonlinear behavior of rectangular dampers subjected to cyclic loading. The target of this study was to determine what shape was efficient for rectangular tensile brace dampers. The safety of the developed rectangular dampers was also checked for better fabrication.

Experimental Study on Functional Improvement of Porous Floating Breakwaters (유공부유식방파제의 방파성능에 관한 실험적 연구)

  • Yoon, Jae-Seon;Han, Sae-Jong;Cho, Yong-Sik
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2011.05a
    • /
    • pp.44-48
    • /
    • 2011
  • 본 연구에서는 구조물 상치에 에어챔버를 설치하여 챔버 내부의 공기주입량에 따라 흘수심을 조절 할 수 있는 유공 및 투수성부유식방파제를 사용하였으며, 부유식방파제의 흘수심구간에 유공을 두어 내부의 흐름에 따른 에너지소산 효과를 수리모형실험을 통하여 분석하였다. 기존 연구에 의하여 선행되어진 부유식방파제의 형상은 구조물 제체의 입사면과 투과면이 막힌 형태의 연구가 대다수였으나, 계류라인의 장력에 따른 부체의 안정성을 고려하여 본 수리모형실험에서는 입사면 흘수심구간과 투과면 흘수심구간에 유공 및 투수층을 두어 진행하는 입사파랑을 일부 흡수하도록 하였다. 또한, 부유식방파제 흘수심단면의 내부에서 흐름변화에 의한 에너지소산 효과와 입사면과 투과면의 유공률 변화에 따른 방파성능을 무공 부유식방파제와 비교하며 효율성을 분석하였다.

  • PDF

Characteristics of Energy Dissipation in Nano Shock Suspension System Using Silica Gel (세라믹 분말을 이용한 나노 충격 완화 장치의 에너지 소산 효율 특성에 대한 연구)

  • 문병영;정성원
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.7 no.3
    • /
    • pp.17-22
    • /
    • 2003
  • This paper presents an experimental investigation of a reversible colloidal seismic damper, which is statically loaded, The porous matrix is composed from silica gel (labyrinth or central-cavity architecture), coated by organo-silicones substances, in order to achieve a hydrophobic surface. Water is considered as associated lyophobic liquid. Reversible colloidal damper static test rig and the measuring technique of the static hysteresis are described. Influence of the pare and particle diameters, particle architecture and length of the grafted molecule upon the reversible colloidal damper hysteresis is investigated, for distinctive types and mixtures of porous matrices, Variation of the reversible colloidal damper dissipated energy and efficiency with temperature, pressure, is illustrated.

Optimal Analysis of Irreversible Carnot Cycle Based on Entransy Dissipation (엔트랜시 소산에 기반한 비가역 카르노 사이클의 최적 해석)

  • Kim, Kyoung Hoon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.41 no.2
    • /
    • pp.87-95
    • /
    • 2017
  • The concept of entransy has been proposed recently as a potential heat transfer mechanism and could be useful in analyzing and optimizing the heat-work conversion systems. This work presents an entransy analysis for the irreversible Carnot cycle by systematic balance formulations of the entransy loss, work entransy, and entransy dissipations, which are consistent with exergy balances. Additionally, several forms of system efficiency are introduced based on entransy for the appreciation of the optimal system performance. The effects of the source temperature and irreversible efficiencies on the optimal conditions for system efficiencies are systematically investigated for both dumping and non-dumping cases of used source fluid. The results show different trends in entransy efficiencies when compared to the conventional efficiencies of energy and exergy, and represent another method to assess the effective use of heat source in power generation systems.

Experimental Test for Seismic Performance of PCS Structural System (PCS 구조 시스템의 내진 성능 분석)

  • Park, Soon-Kyu;Yeo, In-Seok
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.3
    • /
    • pp.313-322
    • /
    • 2007
  • The PCS system, which consists of precast concrete column and steel beam, is a kind of composite structural systems. In this paper, experimental study has been conducted to analyze seismic performance of bolted beam-to-column connections for the PCS system. Based on experimental results from the seismic testing of eight interior PCS specimens, it shows that behavior of PCS system is satisfactory to seismic performance criteria of ACI such as strength deterioration, stiffness degradation and energy dissipation capacity except initial stiffness. All of the specimens maintain their strength at large levels of story drift without significant loss of stiffness and show high ductility level for inelastic behavior. The energy dissipation capacity is two times greater than requirement of ACI criterion. But the initial stiffness of all specimens does not satisfy ACI criterion, and this phenomenon is similar to the other composite structural systems such as RCS, CFT system.

Basic Study of the Hysteresis of a Nano Shock Absorbing Damper by Employing Mixed Lyophobic Coating Silica Gel (실리카 겔의 소수화 코팅 혼합 정도에 따른 나노 충격 흡수 장치의 이력 현상에 대한 기초적 연구)

  • 문병영;김흥섭
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.7 no.2
    • /
    • pp.59-66
    • /
    • 2003
  • A novel application of nano-technology in the field of engineering, called colloidal damper, is investigated. This device is complementary to the hydraulic damper, having a cylinder-piston construction. Particularly for colloidal damper, the hydraulic oil is replacedby a colloidal suspension, which is consisted from a nano-porous matrix with controlled architecture and a lyophobic fluid. In this experimental work, the porous matrix is composed from silica gel, with labyrinth architecture, coated by organo-silicones substances in order to achieve a hydrophobic surface. Water is considered as associated lyophobic fluid. The colloidal damper test rig and the measuring technique of the hysteresis are described. the influence of the hydrophobicity level upon the colloidal damper hysteresis is investigated, for silica gels with similar pores distribution. A certain desired shape of the hysteresis can be achieved by employing mixture of silica gels with different level of hydrophobicity and/or architecture. With these results, it is believed that the proposed damper can be designed and be applied to the desired structure.

Optimal Design of Linear Viscous Damping System for Vibration Control of Adjacent Building Structures (인접구조물의 진동제어를 위한 선형감쇠시스템의 최적설계)

  • Park, Kwan-Soon;Ok, Seung-Yong;Koh, Hyun-Moo
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.10 no.3 s.49
    • /
    • pp.85-100
    • /
    • 2006
  • This paper proposes an optimal design method of linear viscous dampers for the seismic performance of two adjacent structures with different heights. Accordingly, connection method using diagonal bracing between two floors and connection method between two structures are considered, and the effectiveness of the latter method is confirmed through the comparison of the frequency response functions with respect to damping capacity. Moreover, optimal damping to minimize the response of the adjacent structures in the frequency domain is found. The sensitivity of natural frequency and modal damping according to the damper capacity at each floor is obtained for the optimally designed system. From the sensitivity analysis, the modal damping is evaluated to be very sensitive to the damper installed at higher floor. Therefore, sensitivity-based damping distribution method is proposed. Diagonal bracing connection method, uniform distribution method and sensitivity-based distribution method are compared to each other in terms of seismic performance. The comparative results demonstrate that the proposed method is an effective seismic design method for the adjacent structures.